Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Bone Marrow Transplant ; 55(5): 992, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31953531

RESUMEN

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

3.
Infect Dis Clin Pract (Baltim Md) ; 27(3): 123-125, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31467470

RESUMEN

Burkholderia cepacia prosthetic valve endocarditis (PVE) is extremely rare, with few cases in the literature. A report of a patient with PVE is described, followed by a literature review on B. cepacia PVE. A 38 year old man with poor dentition and a history of intravenous drug use (IVDU) and mitral valve replacement was found to have a mitral valve vegetation. Five sets of blood cultures on different days grew B. cepacia. Individual sets of blood cultures on different dates also isolated S. viridans (outside hospital culture), methicillin-resistant S. epidermidis (hospital day 1), and Bacillus spp. (hospital day 6). He was successfully treated with ceftazidime and levofloxacin as dual therapy for B. cepacia PVE, in addition to vancomycin for gram positive coverage. This case report and review highlights the possibility of B. cepacia PVE in immunocompetent patients with poor dentition, with the potential for a successful outcome following combination antimicrobial therapy.

5.
Skin Res Technol ; 25(3): 289-293, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30414198

RESUMEN

BACKGROUND: Clinical assessment of skin stiffness is unreliable in many applications. The durometer, an industrial device to measure hardness, has previously been applied in scleroderma. The Myoton is a noninvasive handheld device for assessing soft tissue biomechanical parameters. MATERIALS AND METHODS: We evaluated the reproducibility of both devices in six healthy subjects in the volar forearm, dorsal forearm, upper arm, shin, and calf bilaterally. The intraclass correlation coefficient (ICC) was used as a measure of reproducibility among three observers. RESULTS: The interobserver intraclass correlation coefficient (ICC) of overall stiffness for the Myoton was 0.74 [95% confidence interval (CI) 0.45-1.00] and 0.71 [0.39-1.00] for the durometer. Coefficient of variation (CV) for the Myoton was 6.4% [range 1.3-12.1] and 7.6% [range 4.4-13.8] for the durometer. Myoton and durometer values had a Pearson correlation of 0.69. The intraobserver Myoton ICC was 0.89 [0.74-1.00] and CV 3.1% [range 1.6-5.0]. The 95% confidence minimal detectable change by the Myoton for a single observer is 32.4 N/m, which is 7.6% of the average subject's overall stiffness. CONCLUSION: The Myoton demonstrated high reproducibility, particularly in the overall stiffness parameter, and merits further investigation to assess disease progression and treatment efficacy.


Asunto(s)
Brazo/fisiología , Dermatología/instrumentación , Dureza , Fisiología/instrumentación , Fenómenos Fisiológicos de la Piel , Voluntarios Sanos , Humanos , Ensayo de Materiales , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...