Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Medicine (Baltimore) ; 94(46): e2011, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26579807

RESUMEN

Cardiovascular impairments are frequent in Cushing's syndrome and the hypercortisolism can result in cardiac structural and functional changes that lead in rare cases to dilated cardiomyopathy (DCM). Such cardiac impairment may be reversible in response to a eucortisolaemic state.A 43-year-old man with a medical past of hypertension and history of smoking presented to the emergency department with global heart failure. Coronary angiography showed a significant stenosis of a marginal branch and cardiac MRI revealed a nonischemic DCM. The left ventricular ejection fraction (LVEF) was estimated as 28% to 30%. Clinicobiological features and pituitary imaging pointed toward Cushing's disease and administration of adrenolytic drugs (metyrapone and ketoconazole) was initiated. Despite the normalization of cortisol which had been achieved 2 months later, the patient presented an acute heart failure. A massive mitral regurgitation secondary to posterior papillary muscle rupture was diagnosed as a complication of the occlusion of the marginal branch. After 6 months of optimal pharmacological treatment for systolic heart failure, as well as treatment with inhibitors of steroidogenesis, there was no improvement of LVEF. The percutaneous mitral valve was therefore repaired and a defibrillator implanted. The severity of heart failure contraindicated pituitary surgery and the patient was instead treated by stereotaxic radiotherapy.This is the first case reporting a Cushing's syndrome DCM without improvement of LVEF despite normalization of serum cortisol levels.


Asunto(s)
Cardiomiopatía Dilatada/etiología , Síndrome de Cushing/diagnóstico , Adulto , Síndrome de Cushing/complicaciones , Humanos , Masculino
2.
Arch Cardiovasc Dis ; 108(5): 281-92, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25863427

RESUMEN

BACKGROUND: As current multidetector computed tomography (MDCT) measurements underestimate the size of the aortic annulus ahead of transcatheter aortic valve implantation (TAVI), a strategy of approximate annulus area oversizing has been adopted recently. AIMS: To measure the aortic annulus using a novel complementary intravalvular MDCT slice. METHODS: Fifty-five patients with severe aortic stenosis were selected for MDCT ahead of and 1 month after CoreValve(®) TAVI. Two MDCT slices were analysed and compared: the current standard virtual basal ring (VBR) at the nadir of the aortic cusps; and a novel slice, defined as the basal (lowest) complete commissural coaptation (BCCC) plane. RESULTS: BCCC is an intravalvular plane lying 5.2±0.8 mm above the VBR. The BCCC annulus is almost circular, unlike the VBR (mean eccentricity index 0.09±0.04 vs 0.3±0.1, respectively). The mean BCCC annulus diameter was 26.6±2.3 mm, 16% larger than that of the VBR (23.9±2.2 mm; P<0.001). The BCCC annulus area proved coherent with the orifice area measured after TAVI on the projection of the same slice (i.e. systematically equal to or greater than the latter [mean difference, +2.3±1.4 mm]), in contrast to the wider scatter found for the VBR (-1.3±2.0 mm). Once the sclerotic calcified valves have been pushed back by the implant, the aortic orifice after TAVI will inevitably be equal to or less than the diameter of the virtually unvalved annulus before TAVI. CONCLUSION: Based on the present results, we recommend including a BCCC slice to complete aortic annulus sizing, in order to optimize implant calibration.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Adulto Joven
3.
J Cardiovasc Med (Hagerstown) ; 16 Suppl 1: S27-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25333374

RESUMEN

A 71-year-old man presented in emergency department for non-ST-elevation myocardial infarction. At admission, 12-lead ECG was in sinus rhythm without sign of myocardial ischemia, and troponin slightly increased. The only notable feature of the patient's medical history was single-vessel coronary artery disease revealed 10 years previously, treated by stenting of the second segment of the right coronary artery with a 3.0 x 25 mm bare metal stent. Three months later, intrastent restenosis was managed by implantation of a 3.0 × 28 mm paclitaxel-eluting stent. Two years before the present admission, following a non contributive stress test for atypical chest pain, coronary angiogram had found a 60% diffuse intrastent restenosis. The present coronary angiogram performed via a right transradial approach demonstrated a focal intrastent restenosis (85%) with irregular contours. Optical coherence tomography (OCT) showed an atherosclerotic intrastent neolesion with intimal tear. OCT demonstrated more precisely a minimal luminal area of 1.02 mm (77.9% area stenosis), two wide cavities (length 1.1 and 1.4 mm) separated by a plaque rupture of 6.8 mm. Myocardial ischemia was evenly demonstrated on this artery with a fractional flow reserve under 0.50 after 150 mg intracoronary adenosine bolus. The culprit lesion was treated by a 3.0 × 38 mm everolimus-eluting stent, with good angiographic results, confirmed on OCT.


Asunto(s)
Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Isquemia Miocárdica/etiología , Revascularización Miocárdica/métodos , Intervención Coronaria Percutánea/métodos , Placa Aterosclerótica/complicaciones , Anciano , Angiografía Coronaria , Reestenosis Coronaria/complicaciones , Reestenosis Coronaria/diagnóstico por imagen , Everolimus , Humanos , Inmunosupresores/administración & dosificación , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica
4.
Catheter Cardiovasc Interv ; 85(7): E203-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25510638

RESUMEN

OBJECTIVES: To assess the feasibility and safety of transcatheter aortic valve implantation (TAVI) through a left transcarotid approach in patients previously operated on for ipsilateral carotid endarterectomy (CEA). BACKGROUND: The healthcare impact of extracranial carotid artery disease is essential as stroke is the third-leading cause of death in industrialized nations and CEA is often present in the history of patients awaiting TAVI. METHODS: The primary endpoint was to evaluate 30-day mortality and freedom from major TAVI-related complications in an observational analysis. RESULTS: From December 2011 to February 2014, we performed 9 TAVI. The mean age was 84.6 years. The procedure was performed without any technical complication or vascular injury in every patient. There was neither intraoperative mortality nor intraoperative major complications. One (11.1%) patient experienced spatial-temporal disorientation but cerebral computed tomography did not show any sign of stroke. Two (22.2%) patients needed the implantation of a pacemaker due to third-degree atrioventricular block appearance. Three (33.3%) patients were transfused with packed red blood cells and 1 (11.1%) patient developed a groin hematoma. Only 1 (11.1%) patient showed a residual paravalvular regurgitation ≥ 2. At 30-day follow-up there was neither mortality nor other TAVI-related complications and echocardiography parameters remained stable. CONCLUSIONS: TAVI through a left transcarotid approach in patients previously operated on for ipsilateral CEA is feasible and safe. The presence of a previous ipsilateral CEA represents no more a limitation to the utilization of this promising access route. At short-term follow-up, mortality and major complications rates are low.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Enfermedades de las Arterias Carótidas/cirugía , Endarterectomía Carotidea , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Endarterectomía Carotidea/efectos adversos , Estudios de Factibilidad , Femenino , Francia , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Complicaciones Posoperatorias/terapia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA