1.
Neuroimage ; 286: 120506, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38185186

RESUMEN

Arterial spin labeling (ASL) is a promising, non-invasive perfusion magnetic resonance imaging technique for quantifying cerebral blood flow (CBF). Unfortunately, ASL suffers from an inherently low signal-to-noise ratio (SNR) and spatial resolution, undermining its potential. Increasing spatial resolution without significantly sacrificing SNR or scan time represents a critical challenge towards routine clinical use. In this work, we propose a model-based super-resolution reconstruction (SRR) method with joint motion estimation that breaks the traditional SNR/resolution/scan-time trade-off. From a set of differently oriented 2D multi-slice pseudo-continuous ASL images with a low through-plane resolution, 3D-isotropic, high resolution, quantitative CBF maps are estimated using a Bayesian approach. Experiments on both synthetic whole brain phantom data, and on in vivo brain data, show that the proposed SRR Bayesian estimation framework outperforms state-of-the-art ASL quantification.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Angiografía por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Marcadores de Spin , Teorema de Bayes , Angiografía por Resonancia Magnética/métodos , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Relación Señal-Ruido , Imagen por Resonancia Magnética/métodos
2.
Artículo en Inglés | MEDLINE | ID: mdl-38082625

RESUMEN

Due to acquisition time constraints, T2-w FLAIR MRI of Multiple Sclerosis (MS) patients is often acquired with multi-slice 2D protocols with a low through-plane resolution rather than with high-resolution 3D protocols. Automated lesion segmentation on such low-resolution (LR) images, however, performs poorly and leads to inaccurate lesion volume estimates. Super-resolution reconstruction (SRR) methods can then be used to obtain a high-resolution (HR) image from multiple LR images to serve as input for lesion segmentation. In this work, we evaluate the effect on MS lesion segmentation of three SRR approaches: one based on interpolation, a state-of-the-art self-supervised CNN-based strategy, and a recently proposed model-based SRR method. These SRR strategies were applied to LR acquisitions simulated from 3D T2-w FLAIR MRI of MS patients. Each SRR method was evaluated in terms of image reconstruction quality and subsequent lesion segmentation performance. When compared to segmentation on LR images, the three considered SRR strategies demonstrate improved lesion segmentation. Furthermore, in some scenarios, SRR achieves a similar segmentation performance compared to segmentation of HR images.Clinical relevance- This study demonstrates the positive impact of super-resolution reconstruction from T2-w FLAIR multi-slice MRI acquisitions on segmentation performance of MS lesions.


Asunto(s)
Fenómenos Biológicos , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos
3.
Magn Reson Med ; 90(3): 1172-1208, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37279038

RESUMEN

PURPOSE: To systematically review the techniques that address undersampling artifacts in accelerated quantitative magnetic resonance imaging (qMRI). METHODS: A literature search was conducted using the Embase, Medline, Web of Science Core Collection, Coherence Central Register of Controlled Trials, and Google Scholar databases for studies, published before July 2022 proposing reconstruction techniques for accelerated qMRI. Studies are reviewed according to inclusion criteria, and included studies are categorized based on the methodology used. RESULTS: A total of 292 studies included in the review are categorized. A technical overview of each category is provided, and the categories are described in a unified mathematical framework. The distribution of the reviewed studies over time, application domain, and parameters of interest is illustrated. CONCLUSION: An increasing trend in the number of articles that propose new techniques for accelerated qMRI reconstruction indicates the importance of acceleration in qMRI. The techniques are mostly validated for relaxometry parameters and brain scans. The categories of techniques are compared based on theoretical grounds, highlighting existing trends and potential gaps in the field.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Artefactos , Imagen por Resonancia Magnética/métodos
4.
J Neurotrauma ; 40(13-14): 1317-1338, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36974359

RESUMEN

The prediction of functional outcome after mild traumatic brain injury (mTBI) is challenging. Conventional magnetic resonance imaging (MRI) does not do a good job of explaining the variance in outcome, as many patients with incomplete recovery will have normal-appearing clinical neuroimaging. More advanced quantitative techniques such as diffusion MRI (dMRI), can detect microstructural changes not otherwise visible, and so may offer a way to improve outcome prediction. In this study, we explore the potential of linear support vector classifiers (linearSVCs) to identify dMRI biomarkers that can predict recovery after mTBI. Simultaneously, the harmonization of fractional anisotropy (FA) and mean diffusivity (MD) via ComBat was evaluated and compared for the classification performances of the linearSVCs. We included dMRI scans of 179 mTBI patients and 85 controls from the Collaborative European NeuroTrauma Effectiveness Research in Traumatic Brain Injury (CENTER-TBI), a multi-center prospective cohort study, up to 21 days post-injury. Patients were dichotomized according to their Extended Glasgow Outcome Scale (GOSE) scores at 6 months into complete (n = 92; GOSE = 8) and incomplete (n = 87; GOSE <8) recovery. FA and MD maps were registered to a common space and harmonized via the ComBat algorithm. LinearSVCs were applied to distinguish: (1) mTBI patients from controls and (2) mTBI patients with complete from those with incomplete recovery. The linearSVCs were trained on (1) age and sex only, (2) non-harmonized, (3) two-category-harmonized ComBat, and (4) three-category-harmonized ComBat FA and MD images combined with age and sex. White matter FA and MD voxels and regions of interest (ROIs) within the John Hopkins University (JHU) atlas were examined. Recursive feature elimination was used to identify the 10% most discriminative voxels or the 10 most discriminative ROIs for each implementation. mTBI patients displayed significantly higher MD and lower FA values than controls for the discriminative voxels and ROIs. For the analysis between mTBI patients and controls, the three-category-harmonized ComBat FA and MD voxel-wise linearSVC provided significantly higher classification scores (81.4% accuracy, 93.3% sensitivity, 80.3% F1-score, and 0.88 area under the curve [AUC], p < 0.05) compared with the classification based on age and sex only and the ROI approaches (accuracies: 59.8% and 64.8%, respectively). Similar to the analysis between mTBI patients and controls, the three-category-harmonized ComBat FA and MD maps voxelwise approach yields statistically significant prediction scores between mTBI patients with complete and those with incomplete recovery (71.8% specificity, 66.2% F1-score and 0.71 AUC, p < 0.05), which provided a modest increase in the classification score (accuracy: 66.4%) compared with the classification based on age and sex only and ROI-wise approaches (accuracy: 61.4% and 64.7%, respectively). This study showed that ComBat harmonized FA and MD may provide additional information for diagnosis and prognosis of mTBI in a multi-modal machine learning approach. These findings demonstrate that dMRI may assist in the early detection of patients at risk of incomplete recovery from mTBI.


Asunto(s)
Conmoción Encefálica , Lesiones Traumáticas del Encéfalo , Humanos , Conmoción Encefálica/diagnóstico , Imagen de Difusión Tensora/métodos , Máquina de Vectores de Soporte , Estudios Prospectivos , Pronóstico , Anisotropía , Encéfalo/patología
5.
Hum Brain Mapp ; 44(4): 1793-1809, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36564927

RESUMEN

Tensor-valued diffusion encoding facilitates data analysis by q-space trajectory imaging. By modeling the diffusion signal of heterogeneous tissues with a diffusion tensor distribution (DTD) and modulating the encoding tensor shape, this novel approach allows disentangling variations in diffusivity from microscopic anisotropy, orientation dispersion, and mixtures of multiple isotropic diffusivities. To facilitate the estimation of the DTD parameters, a parsimonious acquisition scheme coupled with an accurate and precise estimation of the DTD is needed. In this work, we create two precision-optimized acquisition schemes: one that maximizes the precision of the raw DTD parameters, and another that maximizes the precision of the scalar measures derived from the DTD. The improved precision of these schemes compared to a naïve sampling scheme is demonstrated in both simulations and real data. Furthermore, we show that the weighted linear least squares (WLLS) estimator that uses the squared reciprocal of the noisy signal as weights can be biased, whereas the iteratively WLLS estimator with the squared reciprocal of the predicted signal as weights outperforms the conventional unweighted linear LS and nonlinear LS estimators in terms of accuracy and precision. Finally, we show that the use of appropriate constraints can considerably increase the precision of the estimator with only a limited decrease in accuracy.


Asunto(s)
Encéfalo , Proyectos de Investigación , Humanos , Encéfalo/diagnóstico por imagen , Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Análisis de los Mínimos Cuadrados
6.
Magn Reson Med ; 89(1): 396-410, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36110059

RESUMEN

PURPOSE: To introduce a novel imaging and parameter estimation framework for accurate multi-shot diffusion MRI. THEORY AND METHODS: We propose a new framework called ADEPT (Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs) that enables fast diffusion MRI by allowing diffusion contrast settings to change between shots in a multi-shot EPI acquisition (i.e., intra-scan modulation). The framework estimates diffusion parameter maps directly from the acquired intra-scan modulated k-space data, while simultaneously accounting for shot-to-shot phase inconsistencies. The performance of the estimation framework is evaluated using Monte Carlo simulation studies and in-vivo experiments and compared to that of reference methods that rely on parallel imaging for shot-to-shot phase correction. RESULTS: Simulation and real-data experiments show that ADEPT yields more accurate and more precise estimates of the diffusion metrics in multi-shot EPI data in comparison with the reference methods. CONCLUSION: ADEPT allows fast multi-shot EPI diffusion MRI without significantly degrading the accuracy and precision of the estimated diffusion maps.


Asunto(s)
Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Simulación por Computador , Método de Montecarlo , Encéfalo/diagnóstico por imagen
7.
Front Neurosci ; 16: 1044510, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36440272

RESUMEN

Multi-slice (MS) super-resolution reconstruction (SRR) methods have been proposed to improve the trade-off between resolution, signal-to-noise ratio and scan time in magnetic resonance imaging. MS-SRR consists in the estimation of an isotropic high-resolution image from a series of anisotropic MS images with a low through-plane resolution, where the anisotropic low-resolution images can be acquired according to different acquisition schemes. However, it is yet unclear how these schemes compare in terms of statistical performance criteria, especially for regularized MS-SRR. In this work, the estimation performance of two commonly adopted MS-SRR acquisition schemes based on shifted and rotated MS images respectively are evaluated in a Bayesian framework. The maximum a posteriori estimator, which introduces regularization by incorporating prior knowledge in a statistically well-defined way, is put forward as the estimator of choice and its accuracy, precision, and Bayesian mean squared error (BMSE) are used as performance criteria. Analytic calculations as well as Monte Carlo simulation experiments show that the rotated scheme outperforms the shifted scheme in terms of precision, accuracy, and BMSE. Furthermore, the superior performance of the rotated scheme is confirmed in real data experiments and in retrospective simulation experiments with and without inter-image motion. Results show that the rotated scheme allows regularized MS-SRR with a higher accuracy and precision than the shifted scheme, besides being more resilient to motion.

8.
Neuroimage ; 256: 119219, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35447354

RESUMEN

The free water elimination (FWE) model and its kurtosis variant (DKI-FWE) can separate tissue and free water signal contributions, thus providing tissue-specific diffusional information. However, a downside of these models is that the associated parameter estimation problem is ill-conditioned, necessitating the use of advanced estimation techniques that can potentially bias the parameter estimates. In this work, we propose the T2-DKI-FWE model that exploits the T2 relaxation properties of both compartments, thereby better conditioning the parameter estimation problem and providing, at the same time, an additional potential biomarker (the T2 of tissue). In our approach, the T2 of tissue is estimated as an unknown parameter, whereas the T2 of free water is assumed known a priori and fixed to a literature value (1573 ms). First, the error propagation of an erroneous assumption on the T2 of free water is studied. Next, the improved conditioning of T2-DKI-FWE compared to DKI-FWE is illustrated using the Cramér-Rao lower bound matrix. Finally, the performance of the T2-DKI-FWE model is compared to that of the DKI-FWE and T2-DKI models on both simulated and real datasets. The error due to a biased approximation of the T2 of free water was found to be relatively small in various diffusion metrics and for a broad range of erroneous assumptions on its underlying ground truth value. Compared to DKI-FWE, using the T2-DKI-FWE model is beneficial for the identifiability of the model parameters. Our results suggest that the T2-DKI-FWE model can achieve precise and accurate diffusion parameter estimates, through effective reduction of free water partial volume effects and by using a standard nonlinear least squares approach. In conclusion, incorporating T2 relaxation properties into the DKI-FWE model improves the conditioning of the model fitting, while only requiring an acquisition scheme with at least two different echo times.


Asunto(s)
Imagen de Difusión Tensora , Agua , Benchmarking , Encéfalo/metabolismo , Difusión , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora/métodos , Humanos , Agua/metabolismo
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3869-3872, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34890324

RESUMEN

The clinical application of diffusion MRI is practically hindered by its long scan time. In this work, we introduce a novel imaging and parameter estimation framework for time-efficient diffusion MRI. To improve the scan efficiency, we propose ADEPT (Accelerated Diffusion EPI with multi-contrast shoTs), in which diffusion contrast settings are allowed to change between shots in a multi-shot EPI acquisition (i.e. intra-scan modulation). The framework simultaneously corrects for artifacts related to shot-to-shot phase inconsistencies in multi-shot imaging by iteratively estimating the phase map parameters along with the diffusion model parameters directly from the acquired intra-scan modulated k-space data. Monte Carlo simulation experiments show the effective estimation of diffusion tensor parameters in multi-shot EPI diffusion imaging.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Artefactos , Simulación por Computador , Imagen de Difusión por Resonancia Magnética
10.
Magn Reson Med ; 84(5): 2523-2536, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32424947

RESUMEN

PURPOSE: To determine whether sacrificing part of the scan time of pseudo-continuous arterial spin labeling (PCASL) for measurement of the labeling efficiency and blood T1 is beneficial in terms of CBF quantification reliability. METHODS: In a simulation framework, 5-minute scan protocols with different scan time divisions between PCASL data acquisition and supporting measurements were evaluated in terms of CBF estimation variability across both noise and ground truth parameter realizations taken from the general population distribution. The entire simulation experiment was repeated for a single-post-labeling delay (PLD), multi-PLD, and free-lunch time-encoded (te-FL) PCASL acquisition strategy. Furthermore, a real data study was designed for preliminary validation. RESULTS: For the considered population statistics, measuring the labeling efficiency and the blood T1 proved beneficial in terms of CBF estimation variability for any distribution of the 5-minute scan time compared to only acquiring ASL data. Compared to single-PLD PCASL without support measurements as recommended in the consensus statement, a 26%, 33%, and 42% reduction in relative CBF estimation variability was found for optimal combinations of supporting measurements with single-PLD, free-lunch, and multi-PLD PCASL data acquisition, respectively. The benefit of taking the individual variation of blood T1 into account was also demonstrated in the real data experiment. CONCLUSIONS: Spending time to measure the labeling efficiency and the blood T1 instead of acquiring more averages of the PCASL data proves to be advisable for robust CBF quantification in the general population.


Asunto(s)
Encéfalo , Circulación Cerebrovascular , Arterias , Encéfalo/diagnóstico por imagen , Humanos , Angiografía por Resonancia Magnética , Reproducibilidad de los Resultados , Marcadores de Spin
11.
Front Neurosci ; 14: 396, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32435181

RESUMEN

MRI diffusion data suffers from significant inter- and intra-site variability, which hinders multi-site and/or longitudinal diffusion studies. This variability may arise from a range of factors, such as hardware, reconstruction algorithms and acquisition settings. To allow a reliable comparison and joint analysis of diffusion data across sites and over time, there is a clear need for robust data harmonization methods. This review article provides a comprehensive overview of diffusion data harmonization concepts and methods, and their limitations. Overall, the methods for the harmonization of multi-site diffusion images can be categorized in two main groups: diffusion parametric map harmonization (DPMH) and diffusion weighted image harmonization (DWIH). Whereas DPMH harmonizes the diffusion parametric maps (e.g., FA, MD, and MK), DWIH harmonizes the diffusion-weighted images. Defining a gold standard harmonization technique for dMRI data is still an ongoing challenge. Nevertheless, in this paper we provide two classification tools, namely a feature table and a flowchart, which aim to guide the readers in selecting an appropriate harmonization method for their study.

12.
NMR Biomed ; 33(12): e4182, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-31736223

RESUMEN

Multi-post-labeling-delay pseudo-continuous arterial spin labeling (multi-PLD PCASL) allows for absolute quantification of the cerebral blood flow (CBF) as well as the arterial transit time (ATT). Estimating these perfusion parameters from multi-PLD PCASL data is a non-linear inverse problem, which is commonly tackled by fitting the single-compartment model (SCM) for PCASL, with CBF and ATT as free parameters. The longitudinal relaxation time of tissue T1t is an important parameter in this model, as it governs the decay of the perfusion signal entirely upon entry in the imaging voxel. Conventionally, T1t is fixed to a population average. This approach can cause CBF quantification errors, as T1t can vary significantly inter- and intra-subject. This study compares the impact on CBF quantification, in terms of accuracy and precision, of either fixing T1t , the conventional approach, or estimating it alongside CBF and ATT. It is shown that the conventional approach can cause a significant bias in CBF. Indeed, simulation experiments reveal that if T1t is fixed to a value that is 10% off its true value, this may already result in a bias of 15% in CBF. On the other hand, as is shown by both simulation and real data experiments, estimating T1t along with CBF and ATT results in a loss of CBF precision of the same order, even if the experiment design is optimized for the latter estimation problem. Simulation experiments suggest that an optimal balance between accuracy and precision of CBF estimation from multi-PLD PCASL data can be expected when using the two-parameter estimator with a fixed T1t value between population averages of T1t and the longitudinal relaxation time of blood T1b .


Asunto(s)
Arterias/fisiología , Circulación Cerebrovascular/fisiología , Marcadores de Spin , Adulto , Simulación por Computador , Femenino , Sustancia Gris/irrigación sanguínea , Sustancia Gris/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Proyectos de Investigación , Relación Señal-Ruido , Adulto Joven
13.
IEEE Trans Med Imaging ; 37(11): 2414-2427, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29993537

RESUMEN

In quantitative magnetic resonance mapping, the variable flip angle (VFA) steady state spoiled gradient recalled echo (SPGR) imaging technique is popular as it provides a series of high resolution weighted images in a clinically feasible time. Fast, linear methods that estimate maps from these weighted images have been proposed, such as DESPOT1 and iterative re-weighted linear least squares. More accurate, non-linear least squares (NLLS) estimators are in play, but these are generally much slower and require careful initialization. In this paper, we present NOVIFAST, a novel NLLS-based algorithm specifically tailored to VFA SPGR mapping. By exploiting the particular structure of the SPGR model, a computationally efficient, yet accurate and precise map estimator is derived. Simulation and in vivo human brain experiments demonstrate a twenty-fold speed gain of NOVIFAST compared with conventional gradient-based NLLS estimators while maintaining a high precision and accuracy. Moreover, NOVIFAST is eight times faster than the efficient implementations of the variable projection (VARPRO) method. Furthermore, NOVIFAST is shown to be robust against initialization.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Encéfalo/diagnóstico por imagen , Humanos , Masculino , Fantasmas de Imagen
14.
Magn Reson Med ; 80(2): 802-813, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29393531

RESUMEN

PURPOSE: Diffusion kurtosis imaging (DKI) is an advanced magnetic resonance imaging modality that is known to be sensitive to changes in the underlying microstructure of the brain. Image voxels in diffusion weighted images, however, are typically relatively large making them susceptible to partial volume effects, especially when part of the voxel contains cerebrospinal fluid. In this work, we introduce the "Diffusion Kurtosis Imaging with Free Water Elimination" (DKI-FWE) model that separates the signal contributions of free water and tissue, where the latter is modeled using DKI. THEORY AND METHODS: A theoretical study of the DKI-FWE model, including an optimal experiment design and an evaluation of the relative goodness of fit, is carried out. To stabilize the ill-conditioned estimation process, a Bayesian approach with a shrinkage prior (BSP) is proposed. In subsequent steps, the DKI-FWE model and the BSP estimation approach are evaluated in terms of estimation error, both in simulation and real data experiments. RESULTS: Although it is shown that the DKI-FWE model parameter estimation problem is ill-conditioned, DKI-FWE was found to describe the data significantly better compared to the standard DKI model for a large range of free water fractions. The acquisition protocol was optimized in terms of the maximally attainable precision of the DKI-FWE model parameters. The BSP estimator is shown to provide reliable DKI-FWE model parameter estimates. CONCLUSION: The combination of the DKI-FWE model with BSP is shown to be a feasible approach to estimate DKI parameters, while simultaneously eliminating free water partial volume effects. Magn Reson Med 80:802-813, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.


Asunto(s)
Imagen de Difusión Tensora/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Adulto , Algoritmos , Teorema de Bayes , Encéfalo/diagnóstico por imagen , Humanos , Masculino , Modelos Estadísticos , Agua/química
15.
J Nondestr Eval ; 37(3): 62, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30636823

RESUMEN

We present a new approach to estimate geometry parameters of glass fibers in glass fiber-reinforced polymers from simulated X-ray micro-computed tomography scans. Traditionally, these parameters are estimated using a multi-step procedure including image reconstruction, pre-processing, segmentation and analysis of features of interest. Each step in this chain introduces errors that propagate through the pipeline and impair the accuracy of the estimated parameters. In the approach presented in this paper, we reconstruct volumes from a low number of projection angles using an iterative reconstruction technique and then estimate position, direction and length of the contained fibers incorporating a priori knowledge about their shape, modeled as a geometric representation, which is then optimized. Using simulation experiments, we show that our method can estimate those representations even in presence of noisy data and only very few projection angles available.

16.
Magn Reson Med ; 77(5): 1818-1830, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27367848

RESUMEN

PURPOSE: Quantitative T1 mapping is a magnetic resonance imaging technique that estimates the spin-lattice relaxation time of tissues. Even though T1 mapping has a broad range of potential applications, it is not routinely used in clinical practice as accurate and precise high resolution T1 mapping requires infeasibly long acquisition times. METHOD: To improve the trade-off between the acquisition time, signal-to-noise ratio and spatial resolution, we acquire a set of low resolution T1 -weighted images and directly estimate a high resolution T1 map by means of super-resolution reconstruction. RESULTS: Simulation and in vivo experiments show an increased spatial resolution of the T1 map, while preserving a high signal-to-noise ratio and short scan time. Moreover, the proposed method outperforms conventional estimation in terms of root-mean-square error. CONCLUSION: Super resolution T1 estimation enables resolution enhancement in T1 mapping with the use of standard (inversion recovery) T1 acquisition sequences. Magn Reson Med 77:1818-1830, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Algoritmos , Anisotropía , Simulación por Computador , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Modelos Estadísticos , Movimiento (Física) , Fantasmas de Imagen , Reproducibilidad de los Resultados , Relación Señal-Ruido
17.
IEEE Trans Med Imaging ; 36(2): 433-446, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27662674

RESUMEN

In quantitative MR T1 mapping, the spin-lattice relaxation time T1 of tissues is estimated from a series of T1 -weighted images. As the T1 estimation is a voxel-wise estimation procedure, correct spatial alignment of the T1 -weighted images is crucial. Conventionally, the T1 -weighted images are first registered based on a general-purpose registration metric, after which the T1 map is estimated. However, as demonstrated in this paper, such a two-step approach leads to a bias in the final T1 map. In our work, instead of considering motion correction as a preprocessing step, we recover the motion-free T1 map using a unified estimation approach. In particular, we propose a unified framework where the motion parameters and the T1 map are simultaneously estimated with a Maximum Likelihood (ML) estimator. With our framework, the relaxation model, the motion model as well as the data statistics are jointly incorporated to provide substantially more accurate motion and T1 parameter estimates. Experiments with realistic Monte Carlo simulations show that the proposed unified ML framework outperforms the conventional two-step approach as well as state-of-the-art model-based approaches, in terms of both motion and T1 map accuracy and mean-square error. Furthermore, the proposed method was additionally validated in a controlled experiment with real T1 -weighted data and with two in vivo human brain T1 -weighted data sets, showing its applicability in real-life scenarios.


Asunto(s)
Imagen por Resonancia Magnética , Algoritmos , Humanos , Funciones de Verosimilitud , Método de Montecarlo , Movimiento (Física) , Reproducibilidad de los Resultados
18.
IEEE Trans Med Imaging ; 36(5): 1041-1053, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28026759

RESUMEN

An important factor influencing the quality of magnetic resonance (MR) images is the reconstruction method that is employed, and specifically, the type of prior knowledge that is exploited during reconstruction. In this work, we introduce a new type of prior knowledge, partial discreteness (PD), where a small number of regions in the image are assumed to be homogeneous and can be well represented by a constant magnitude. In particular, we mathematically formalize the partial discreteness property based on a Gaussian Mixture Model (GMM) and derive a partial discreteness image representation that characterizes the salient features of partially discrete images: a constant intensity in homogeneous areas and texture in heterogeneous areas. The partial discreteness representation is then used to construct a novel prior dedicated to the reconstruction of partially discrete MR images. The strength of the proposed prior is demonstrated on various simulated and real k-space data-based experiments with partially discrete images. Results demonstrate that the PD algorithm performs competitively with state-of-the-art reconstruction methods, being flexible and easy to implement.


Asunto(s)
Imagen por Resonancia Magnética , Algoritmos , Bases de Datos Factuales , Procesamiento de Imagen Asistido por Computador
19.
IUCrJ ; 3(Pt 1): 71-83, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26870383

RESUMEN

The increasing need for precise determination of the atomic arrangement of non-periodic structures in materials design and the control of nanostructures explains the growing interest in quantitative transmission electron microscopy. The aim is to extract precise and accurate numbers for unknown structure parameters including atomic positions, chemical concentrations and atomic numbers. For this purpose, statistical parameter estimation theory has been shown to provide reliable results. In this theory, observations are considered purely as data planes, from which structure parameters have to be determined using a parametric model describing the images. As such, the positions of atom columns can be measured with a precision of the order of a few picometres, even though the resolution of the electron microscope is still one or two orders of magnitude larger. Moreover, small differences in average atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark-field scanning transmission electron microscopy images. In addition, this theory allows one to measure compositional changes at interfaces, to count atoms with single-atom sensitivity, and to reconstruct atomic structures in three dimensions. This feature article brings the reader up to date, summarizing the underlying theory and highlighting some of the recent applications of quantitative model-based transmisson electron microscopy.

20.
Magn Reson Med ; 75(1): 181-95, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25613283

RESUMEN

PURPOSE: Diffusion MRI is hampered by long acquisition times, low spatial resolution, and a low signal-to-noise ratio. Recently, methods have been proposed to improve the trade-off between spatial resolution, signal-to-noise ratio, and acquisition time of diffusion-weighted images via super-resolution reconstruction (SRR) techniques. However, during the reconstruction, these SRR methods neglect the q-space relation between the different diffusion-weighted images. METHOD: An SRR method that includes a diffusion model and directly reconstructs high resolution diffusion parameters from a set of low resolution diffusion-weighted images was proposed. Our method allows an arbitrary combination of diffusion gradient directions and slice orientations for the low resolution diffusion-weighted images, optimally samples the q- and k-space, and performs motion correction with b-matrix rotation. RESULTS: Experiments with synthetic data and in vivo human brain data show an increase of spatial resolution of the diffusion parameters, while preserving a high signal-to-noise ratio and low scan time. Moreover, the proposed SRR method outperforms the previous methods in terms of the root-mean-square error. CONCLUSION: The proposed SRR method substantially increases the spatial resolution of MRI that can be obtained in a clinically feasible scan time.


Asunto(s)
Algoritmos , Encéfalo/anatomía & histología , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Adulto , Difusión , Humanos , Modelos Biológicos , Modelos Estadísticos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad