Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nuklearmedizin ; 51(3): 101-10, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22446512

RESUMEN

PURPOSE: To evaluate the calibration of an adaptive thresholding algorithm (contrast-oriented algorithm) for FDG PET-based delineation of tumour volumes in eleven centres with respect to scanner types and image data processing by phantom measurements. METHODS: A cylindrical phantom with spheres of different diameters was filled with FDG realizing different signal-to-background ratios and scanned using 5 Siemens Biograph PET/CT scanners, 5 Philips Gemini PET/CT scanners, and one Siemens ECAT-ART PET scanner. All scans were analysed by the contrast-oriented algorithm implemented in two different software packages. For each site, the threshold SUVs of all spheres best matching the known sphere volumes were determined. Calibration parameters a and b were calculated for each combination of scanner and image-analysis software package. In addition, "scanner-type-specific" calibration curves were determined from all values obtained for each combination of scanner type and software package. Both kinds of calibration curves were used for volume delineation of the spheres. RESULTS: Only minor differences in calibration parameters were observed for scanners of the same type (Δa ≤4%, Δb ≤14%) provided that identical imaging protocols were used whereas significant differences were found comparing calibration parameters of the ART scanner with those of scanners of different type (Δa ≤60%, Δb ≤54%). After calibration, for all scanners investigated the calculated SUV thresholds for auto-contouring did not differ significantly (all p>0.58). The resulting sphere volumes deviated by less than -7% to +8% from the true values. CONCLUSION: After multi-centre calibration the use of the contrast-oriented algorithm for FDG PET-based delineation of tumour volumes in the different centres using different scanner types and specific imaging protocols is feasible.


Asunto(s)
Algoritmos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/normas , Planificación de la Radioterapia Asistida por Computador/normas , Calibración , Análisis de Falla de Equipo/normas , Alemania , Humanos , Dosificación Radioterapéutica , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Strahlenther Onkol ; 172(9): 469-74, 1996 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8830809

RESUMEN

PURPOSE: Quality of a brachytherapy application depends on the choice of the target volume, on the dose distribution homogeneity and radiation injury on critical tissue, which should be postulated by advanced brachytherapy treatment planning systems. MATERIAL AND METHODS: Basic imaging method for conformal treatment planning is the cross-sectional imaging. The clinical applicability of a new type 3D planning system using CT and/or MRT-simulation or US-simulation for planning purposes was studied. The planning system developed at Kiel University differs from usual brachytherapy planning systems because of the obligatory use of cross-sectional imaging as basic imaging method for reconstruction of structures of interest. Dose distribution and normal anatomy can be visualized on each CT/MRT/US slice as well as coronal, sagittal, axial and free chosen reconstruction (3D), as well as dose-volume histogram curves and special colour-coded visualization of dose homogeneity in the target can be analyzed. RESULTS: Because of the experience in the clinical routine, as well as on the base of 30 simultaneous planning procedures on both 2D (semi-3D) and 3D planning systems we observed similar time consumption. Advantages of 3D planning were the better interpretation of target delineation, delineation of critical structures as well as dose distribution, causing more accurate volume optimisation of dose distribution. CONCLUSION: Conformal brachytherapy treatment planning for interstitial brachytherapy means significant advantages for the clinical routine compared to 2D or semi-3D methods.


Asunto(s)
Braquiterapia/métodos , Planificación de la Radioterapia Asistida por Computador , Algoritmos , Neoplasias de los Conductos Biliares/radioterapia , Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Neoplasias Encefálicas/radioterapia , Estudios de Evaluación como Asunto , Femenino , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias Orbitales/radioterapia , Neoplasias de la Próstata/radioterapia , Dosis de Radiación , Sarcoma/radioterapia , Neoplasias de los Tejidos Blandos/radioterapia , Tomografía Computarizada por Rayos X , Ultrasonografía , Neoplasias de la Vejiga Urinaria/radioterapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...