Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Chem ; 18(1): 137, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39061082

RESUMEN

A novel antipsychotic medication named brexpiprazole (BRX) is currently employed for the treatment of schizophrenia and other psychotic disorders. Because BRX's molecular structure includes a benzothiophene ring, it natively fluoresces. To detect BRX with precision and speed, a flow injection-fluorometric method, which is both sensitive and selective, is recommended. The fluorescence detection was conducted at 364 nm following excitation at 326 nm to capture the strong intrinsic fluorescence of BRX. The carrier solution employed was a mixture of phosphate buffer (pH 4, 10 mM) and acetonitrile (50: 50, v/v), with a flow rate of 0.5 mL min- 1. The calibration curve, based on peak areas, exhibited linearity within the concentration range of 20-350 ng mL- 1, with a remarkable correlation coefficient (r2) of 0.9999. The limit of quantitation was 9.7 ng mL- 1, and the limit of detection was found to be 3.2 ng mL- 1. This method was applied to quantify BRX in Neopression® tablets, achieving recovery within an acceptable range without interference from the tablet's additives. Additionally, the proposed approach was successfully utilised to quantify the drug in spiked human plasma. The approach underwent validation following ICH requirements.

2.
Luminescence ; 39(7): e4845, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39054772

RESUMEN

A recently developed antipsychotic drug, lurasidone, was determined using a simple, sensitive, and eco-friendly spectrofluorimetric approach. The suggested approach was based on the quantifiable quenching impact of lurasidone on the inherent fluorescence of erythrosine B in an acidic environment employing a Teorell-Stenhagen buffer (pH 4). Following excitation at 530 nm, the quenching of erythrosine B fluorescence was monitored at 552 nm. The system variables were systematically optimized to enhance the formation of the lurasidone-erythrosine B ion pair for analytical purposes. A linear calibration graph was built in the range of 20-600 ng mL-1 with 0.9998 as a coefficient of correlation. The quantitation and detection limits were 13.5 and 4.5 ng/mL, respectively. The analytical validity of the designed approach was assessed with respect to International Council on Harmonization (ICH) guiding principles. The proposed methodology was employed with high recoveries for assessing lurasidone in bulk powder and its therapeutic tablet dosage form. Additionally, the uniformity of tablet formulations was tested using the developed approach. Finally, the established approach was assessed for its greenness using various tools.


Asunto(s)
Eritrosina , Clorhidrato de Lurasidona , Espectrometría de Fluorescencia , Clorhidrato de Lurasidona/química , Clorhidrato de Lurasidona/análisis , Eritrosina/química , Electricidad Estática , Concentración de Iones de Hidrógeno , Comprimidos/análisis , Antipsicóticos/química , Colorantes Fluorescentes/química , Límite de Detección
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 322: 124838, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39032233

RESUMEN

In this work, the xanthene dye, erythrosine B, was employed as a probe for the determination of olanzapine using two fast and highly simple analytical approaches. The assay was based on the formation of a binary complex between the drug and erythrosine B in a slightly acidic aqueous buffered solution. In the first method, the absorbance of the formed product was monitored at 558 nm. The reaction stoichiometry was investigated, and the stability constant of the formed complex was estimated. The linear range of the method that obeyed Beer's law was in the concentration range of 0.6-8.0 µg/ml. The calculated detection and quantitation limits were 0.2 and 0.6 µg/mL. Upon adding the drug solution to erythrosine B, the native fluorescence of the dye was quenched and monitored at 550 nm after excitation at 528 nm. Thus, the fluorescence quenching was utilized as the quantitative signal in the spectrofluorimetric approach. The extent of quenching in the fluorescence intensity was rectilinear with the drug concentration in a range of 0.1-2.5 µg/ml with a detection limit of 0.032 µg/ml. Both approaches were analytically validated based on the guiding rules of the ICH with acceptable results, and were utilized efficiently in the analysis of olanzapine in commercial tablets containing the cited drug. In addition, owing to its high sensitivity and selectivity, the spectrofluorimetric method was applied for drug analysis in spiked human plasma with satisfactory % recoveries. Finally, the greenness of the methods was confirmed using eco-score scale and Analytical Green Evaluation metrics.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38824745

RESUMEN

A novel and highly sensitive high-performance thin-layer chromatographic (HPTLC) method was developed and validated to quantify a combination of five pharmaceutical mixtures spiked to human plasma. The compounds comprised Amlodipine (AML) along with five angiotensin II receptor antagonist drugs (AIIRAs), namely Olmesartan (OLM), Telmisartan (TLM), Candesartan (CAN), Losartan (LOS), and Irbesartan (IRB). HPTLC was performed on silica gel 60 F254 plates using a mobile phase of Toluene: ethyl acetate: methanol: acetone: acetic acid (6:1.5:1:0.5:1, v/v/v/v/v). In a pioneering move, a reflectance/fluorescence detection mode was employed to identify two concurrently administered drugs at different pH levels for the first time. This method utilized the same chromatographic system, incorporating a specific measurement for AML at a neutral medium to achieve its maximum fluorescence at a 360 nm excitation wavelength, and measuring emission using a 540 nm optical filter. The process involved obtaining a very low fluorescence response from AIIRA. Subsequently, to enhance AIIRA's fluorescence, the plate was sprayed with perchloric acid to transition to a strong acidic medium, ultimately attaining the maximum fluorescence of AIIRA using various excitation wavelengths and a 400 nm emission filter. Through this strategic process, we could optimize the fluorescence signals of both drugs, thereby elevating the sensitivity of detection for this drug combination. AML demonstrated a linear range of 18-300 ng/band, while AIIRAs drugs exhibited a linear range of 6-150 ng/band. The method satisfied the International Conference on Harmonization (ICH) criteria for recovery, precision, repeatability, and robustness, showcasing exceptional sensitivity. The approach was successfully applied to quantify AML and AIIRAs drugs in both bulk drug and plasma samples, achieving high recovery percentages and minimal standard deviations.


Asunto(s)
Amlodipino , Densitometría , Límite de Detección , Amlodipino/sangre , Humanos , Cromatografía en Capa Delgada/métodos , Concentración de Iones de Hidrógeno , Reproducibilidad de los Resultados , Densitometría/métodos , Modelos Lineales , Antagonistas de Receptores de Angiotensina/sangre , Espectrometría de Fluorescencia/métodos
5.
BMC Chem ; 18(1): 92, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702832

RESUMEN

The simultaneous assay of duloxetine hydrochloride (DLX) and avanafil (AVN) in their pure forms, synthetic mixtures, and spiked human plasma was achieved using a novel, eco-friendly, sensitive, and specific HPTLC methodology that have been established and validated. Measuring the levels of co-administered antidepressants and sexual stimulants in biological fluids is an important step for individuals with depression and sexual problems. Separation was performed successfully using pre-coated silica gel 60-F254 as a stationary phase and a mobile phase composed of methanol, acetone, and 33% ammonia (8:2:0.05, v/v/v). Compact bands were produced by the optimized mobile phase that was chosen for development (Rf values were 0.23 and 0.75 for DLX and AVN, individually) after dual-wavelength detection for DLX and AVN at 232 and 253 nm, respectively. The results of polynomial regression analysis were exceptional (r = 0.9999 for both medicines) over concentration ranges of 5-800 and 10-800ng/spot for DLX and AVN, respectively. The quantitation limits were 4.69 and 9.53 ng/spot (0.31 and 0.94 µg/mL), whereas the detection limits were 1.55 and 3.15 ng/spot (0.63 and 1.91 µg/mL), for DLX and AVN, respectively. The International Council for Harmonization (ICH) criteria served as the basis for validating the established approach. Moreover, the proposed technique was evaluated in terms of greenness using four contemporary ecological metrics: The Analytical Greenness software (AGREE), the Green Analytical Procedure Index (GAPI), Eco-Scale, and the National Environmental Method Index (NEMI). Additionally, the Blue Applicability Grade Index (BAGI), a newly developed tool for evaluating the practicality (blueness) of procedures, was taken into consideration when evaluating the sustainability levels of the established approach.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 318: 124515, 2024 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-38810435

RESUMEN

Mirabegron (MRB) is a ß3-adrenoceptor agonist used for managing overactive bladder syndrome. A cost-effective, environmentally friendly, and highly sensitive spectrofluorimetric method was suggested to serve the purpose of quantifying MRB in its pure state, pharmaceutical tablets, spiked human plasma and urine, and testing content uniformity. In the present study, ninhydrin and phenylacetaldehyde react with the amino group moiety of MRB in Teorell-Stenhagen buffer (pH 7.5) to generate a strongly fluorescent diaryl pyrrolone compound that emits fluorescence at a wavelength of 477 nm upon excitation at 385 nm. The obtained calibration curve showed a linear relationship with a high correlation coefficient (r = 0.9997) in the concentration range of 0.25 to 5.0 µg mL-1. Limits of detection (LOD) and quantitation (LOQ) were 0.082 and 0.248 µg mL-1 respectively. The procedure was verified in accordance with the ICH guidelines. The suggested approach could be utilized for the selective analysis of MRB in its pharmaceuticals, either containing a single drug or co-formulated with solifenacin succinate. The greenness of the suggested method was confirmed using different green analytical metrics.


Asunto(s)
Acetanilidas , Límite de Detección , Ninhidrina , Espectrometría de Fluorescencia , Tiazoles , Humanos , Ninhidrina/química , Espectrometría de Fluorescencia/métodos , Acetanilidas/orina , Acetanilidas/sangre , Acetanilidas/química , Tiazoles/química , Tiazoles/orina , Tiazoles/sangre , Pirroles/química , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Comprimidos , Acetaldehído/análogos & derivados
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124519, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38815314

RESUMEN

Vilazodone is a recently approved antidepressant medicine used for treating major depressive disorder. A simple, extremely sensitive, accurate and green spectrofluorimetric method was constructed for its determination through formation of ion-pair complex with erythrosine B. The formation of ion-pair complex lowers the dye's native fluorescence emission measured at 552 nm (λ ex = 530 nm). In terms of analysis, the system's parameters for producing the vilazodone-erythrosine B complex have been optimized. The reaction was carried out in Teorell-Stenhagen buffering solution (pH 4.6). The fluorescence emission intensity of the dye decreased linearly in the range of 20 - 600 ng mL-1 and the correlation coefficient was 0.9999. The quantitation and detection limit values were 18.5 and 6.1 ng mL-1, respectively. The proposed strategy has been validated according to the ICH criteria. The proposed technique was thoroughly employed for evaluating vilazodone in raw material and pharmaceutical tablet dosage form. Furthermore, it was also successfully used for content uniformity testing. Lastly, using four advanced tools namely the Eco-Scale, the National Environmental Method Index (NEMI), the Green Analytical Procedure Index (GAPI), and the Analytical Greenness metric approach (AGREE), the greenness of the established technique was evaluated.


Asunto(s)
Límite de Detección , Espectrometría de Fluorescencia , Clorhidrato de Vilazodona , Clorhidrato de Vilazodona/análisis , Espectrometría de Fluorescencia/métodos , Reproducibilidad de los Resultados , Comprimidos , Tecnología Química Verde/métodos , Concentración de Iones de Hidrógeno , Formas de Dosificación
8.
RSC Adv ; 14(11): 7797-7805, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38444975

RESUMEN

Prucalopride (PCP) is one of the recent drugs used for the regulation of gastrointestinal tract motility and the treatment of constipation. A new, highly sensitive and fast resonance Rayleigh scattering (RRS) approach was suggested for PCP determination. The approach was based on its reaction of PCP with eosin Y in buffered medium (pH 3.5) to form an ion pair association complex which had a significant enhancement in RRS compared to that of eosin Y or PCP alone. The enhancement of RRS intensity had straight correlation to PCP concentration ranging from 150 to 2000 ng mL-1 with 38 ng mL-1 as LOD and 125 ng mL-1 as LOQ. The measurements were done at a wavelength of 365 nm that provided the maximum sensitivity. All the experimental parameters were studied carefully and optimized via Box-Behnken experimental design. The International Council for Harmonization (ICH) guidelines were employed to validate the suggested method and the obtained results proved the appropriate method performance. The method was efficiently utilized to determine PCP in pure form, pharmaceutical tablets and spiked urine samples with no interferences from the surrounding matrices. Furthermore, the greenness of the suggested procedure was confirmed using different green metric approaches.

9.
RSC Adv ; 14(12): 8283-8292, 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38469194

RESUMEN

A green-complied spectrofluorimetric approach for quantification of the antidepressant, fluvoxamine, has been established. The method that has been suggested relies on the development of an association complex between fluvoxamine and erythrosine B in an acetate buffer solution. After being excited at 530 nm, the quenching in erythrosine B's native fluorescence caused by complex formation with fluvoxamine was detected at a wavelength of 552 nm. The values of fluorescence quenching at the most optimal reaction conditions were rectilinear at the concentration range of 0.2-2.0 µg mL-1, with a good correlation coefficient (r = 0.9998). The detection limit for the method was 0.03 µg mL-1 while the quantitation limit was 0.09 µg mL-1. The suggested approach has been validated according to the ICH. The established approach was effectively used to determine the drug under study in its dosage form with an average percent recovery of 98.92 ± 0.87 (n = 5), with no effect caused by the existing excipients. The proposed approach was also successfully used for the content uniformity test.

10.
Spectrochim Acta A Mol Biomol Spectrosc ; 311: 123986, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38335587

RESUMEN

Tolterodine tartrate (TTD) was the first antimuscarinic medication developed exclusively for the treatment of overactive bladder syndrome and was approved by the FDA in 1998. As a result of the drug's extensive utilization within the local community following its authorization, there is a pressing need to develop and validate a spectrofluorometric method that is economically efficient, easily reproducible, environmentally sustainable, and possesses high sensitivity. The developed approach relies on enhancing the fluorescence intensity of TTD to reach a level 720 % higher than its initial value, achieved through the application of an aqueous sodium dodecyl sulfate (SDS) solution. A strong correlation was observed with a correlation coefficient of 0.9998 between the concentration of TTD and the fluorescence intensity within the range of 25.0-500.0 ng mL-1. This approach could be employed to quantify TTD in its pure form and to examine pharmaceutical tablets for the purposes of verifying uniform content. Additionally, it was utilized for the evaluation of TTD concentrations in spiked human plasma.


Asunto(s)
Vejiga Urinaria Hiperactiva , Humanos , Tartrato de Tolterodina , Vejiga Urinaria Hiperactiva/tratamiento farmacológico , Espectrometría de Fluorescencia/métodos , Antagonistas Muscarínicos/uso terapéutico , Dodecil Sulfato de Sodio
11.
BMC Chem ; 18(1): 40, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38388420

RESUMEN

Four sensitive and fast analytical approaches relied on ion pairing with eosin Y were built up and evaluated using spectroscopy for determination of Alcaftadine and Olopatadine hydrochloride with high sensitivity and selectivity. Two spectrofluorimetric techniques were employed to observe the quenching effect of Alcaftadine or Olopatadine hydrochloride on the intrinsic fluorescence of eosin Y in a 0.1 M acetate buffer solution at pH 3.8 and 3.3 for Alcaftadine and Olopatadine hydrochloride, respectively. Those methods are considered the first spectrofluorimetric methods for Alcaftadine and Olopatadine hydrochloride assay. The fluorescence quenching effect was linear with concentration ranging from 150 to 2000 and 200 to 2000 ng mL-1 for Alcaftadine and Olopatadine hydrochloride, respectively. In the two spectrophotometric techniques, the absorbance of the produced ion-pair was monitored at 548 and 547 nm in aqueous buffered solution at pH 3.8 and 3.3 for Alcaftadine and Olopatadine hydrochloride, respectively. Beer's law was obeyed in the concentrations range of 0.8-8.0 and 1.0-10.0 µg mL-1. The four techniques were evaluated in accordance with ICH requirements and were effectively used to analyze dosage forms with a high percent recovery.

12.
BMC Chem ; 18(1): 18, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38268023

RESUMEN

For the treatment of rhinitis and asthma, a combination of Montelukast sodium and Bilastine has just been approved. Based on the first derivative of synchronous fluorescence, the current work developed a green, highly accurate, sensitive, and selective spectroscopic approach for estimating Montelukast sodium and Bilastine in pharmaceutical dosage form without previous separation. The selected technique focuses on measuring the synchronized fluorescence of the studied medications at a fixed wavelength range (Δλ) = 110 nm, and using the amplitude of the first derivative's peak at 381 and 324 nm, for quantitative estimation of Montelukast sodium and Bilastine, respectively. The impacts of different factors on the referred drugs' synchronized fluorescence intensity were investigated and adjusted. The calibration plots for were found to be linear over concentration ranges of 50-2000 ng mL-1 for Montelukast sodium and 50-1000 ng mL-1 for Bilastine. Montelukast sodium and Bilastine have LODs of 16.5 and 10.9 ng mL-1, respectively. In addition, LOQs were: 49.9 and 33.0 ng mL-1, for both drugs, respectively. The developed method was successfully employed to quantify the two drugs in synthetic tablets mixture and in laboratory prepared mixtures containing varied Montelukast and Bilastine ratios. To compare the results with the published analytical approach, a variance ratio F-test and a student t-test were used, which revealed no significant differences.

13.
RSC Adv ; 14(6): 4065-4073, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38288155

RESUMEN

In this paper, vilazodone (VLD), a serotonin modulator prescribed for major depressive disorder, was investigated using a rapid, highly sensitive, and eco-friendly spectrofluorometric approach. The native fluorescence of VLD, originating from its indole moiety, exhibited an emission peak at 486 nm upon excitation at 241 nm. However, the presence of a piperazinyl nitrogen atom in the VLD structure, acting as an electron donor, significantly diminished the fluorescence intensity through photoinduced electron transfer (PET) to the indole ring. However, by protonating this nitrogen atom using 0.02 M Teorell-Stenhagen buffer (pH 3.5), inhibition of the PET process effectively blocked electron transfer, restoring the fluorescent properties of the drug. Further, an enhancement in the fluorescence was achieved by employing methanol as the solvent, resulting in a 1.5-fold increase. The combined use of PET blockage and methanol enabled the detection of VLD at levels as low as 0.78 ng mL-1. Calibration analysis demonstrated linearity within the range 5-400 ng mL-1, exhibiting a correlation coefficient of 0.9998 and a limit of quantification of 2.37 ng mL-1. The method obeyed the requirements of International Council on Harmonization (ICH). The proposed approach was applied for the accurate measurement of VLD in pharmaceutical tablets, content uniformity testing based on USP requirements, and determining VLD concentration in spiked human plasma. Moreover, the environmental impact, in addition to practical effectiveness, of the proposed approach was evaluated using different metrics.

14.
RSC Adv ; 13(50): 35733-35740, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38077977

RESUMEN

Bromocriptine mesylate, a dopamine D2 receptor agonist, has been quantitatively determined using a sensitive, precise, quick, and affordable spectrofluorimetric method. The proposed method relies on the estimation of bromocriptine native fluorescence after the optimization of different factors to improve its inherently weak fluorescence through the use of a sodium dodecyl sulphate micellar system (2% w/v). Following excitation at 238 nm, the enhanced fluorescence intensity of bromocriptine was determined at 418 nm. As compared to its native fluorescence, the bromocriptine fluorescence intensity has been greatly enhanced by about 15 fold by employing the micellar system. The plot of intensity of fluorescence versus bromocriptine concentration was linear in the range of 50-600 ng mL-1. The method was found to have a high sensitivity, as indicated by the low limit of detection and limit of quantitation values (14.57 and 44.16 ng mL-1 respectively). Without the interference of any excipient, this method was effectively employed to quantify bromocriptine in its pharmaceutical dosage form.

15.
J Fluoresc ; 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37930598

RESUMEN

A fast, simple, accurate, precise, and cheap fluorimetric protocol has been proposed for analysis of a phosphodiesterase-IV inhibitor, namely drotaverine hydrochloride. Fluorimetric protocol is based on estimating the decrease in the eosin Y fluorescence intensity by quantitative addition of drotaverine at pH 3.1 (acetate buffer). An ion pair complex is formed, which leads to quenching in the fluorescence intensity of the dye without need of prior extraction at 534 nm (λex. 339 nm). Different reaction perimeters which influence the production of complex (ion pair between drotaverine and eosin) were deeply investigated and optimized. The developed fluorimetric protocol is capable for quantitative estimation of drotaverine in linear range of 0.4 to 2.5 µg mL-1. After method validation in respect to ICH guidelines, it was applied to determine drotaverine in its commercial preparation. By comparing with other reported method, the developed and validated fluorimetric protocol is capable for estimation of drotaverine in commercial preparation with good accuracy and excellent precision.

16.
RSC Adv ; 13(47): 33453-33458, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-38025857

RESUMEN

A new, straightforward spectrofluorimetric approach with high sensitivity was established for determining midodrine hydrochloride based on derivatizing this drug through its reaction with 5-(dimethylamino)naphthalene-1-sulfonyl chloride (dansyl chloride). The highly fluorescent product was extracted with methylene chloride, and then its emission was measured at 532 nm after excitation at 339 nm. The reaction was conducted in aqueous medium containing 0.1 M borate buffer (pH 8.2). The results showed that the proposed method is sensitive with high linearity in the range from 0.1 to 3 µg mL-1. The lower limits of detection and quantitation were 29 and 88 ng mL-1, respectively. Furthermore, the proposed approach was analytically assessed by applying the ICH guidelines. The suggested approach was effectively utilized for the estimation of the medicine in its marketable tablet formulations with excellent recovery and without any interfering effect from excipients. Moreover, the presented approach was utilized to test the content uniformity of commercial tablets following the USP guidelines.

17.
Luminescence ; 38(12): 2065-2072, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37740522

RESUMEN

The prokinetic drug, prucalopride (PCP) succinate, was determined using a new spectrofluorimetric approach with a highly sensitive, rapid, and simple procedure. The method exploited the enhancement of the inherent native fluorescence of PCP by micellar aggregation with sodium lauryl sulfate (SLS) as an anionic surfactant. Different factors that could affect the fluorescence intensity were carefully studied in order to achieve the maximal fluorescence signal. Measurement of the enhanced fluorescence was done at 354 nm after the excitation at 276 nm. The fluorescence intensity-concentration plot was rectilinear in the concentration range of 50-600 ng/ml with detection and quantitation limits of 13.9 and 42.1 ng/ml, respectively. The method underwent validation according to the International Council for Harmonisation criteria in order to assess its analytical performance, and promising results were achieved that proved the validity and reliability of the method. Furthermore, the method was employed effectively for the analysis of the cited drug in commercial pharmaceutical tablets.


Asunto(s)
Succinatos , Límite de Detección , Espectrometría de Fluorescencia/métodos , Reproducibilidad de los Resultados , Comprimidos/análisis
18.
BMC Chem ; 17(1): 75, 2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37452429

RESUMEN

The present work was developed to create three rapid, simple, eco-friendly, cheap spectrophotometric methods for concurrent assay of Sofosbuvir (SOF) and Simeprevir (SMV) in their pure, laboratory prepared mixture and pharmaceutical dosage form with high degree of accuracy and precision. Three methods were developed including iso-absorptive point, ratio subtraction and dual wavelength. The linear range of the proposed methods was 3.0-50.0 and 2.0-50.0 µg mL-1 for SMV and SOF, respectively. The proposed methods were validated according to ICH guidelines in terms of linearity, accuracy, precision, limit of detection and limit of quantitation. The proposed approach is highly simple and the procedure is environmentally green making it suitable for the drug analysis in routine works.

19.
Spectrochim Acta A Mol Biomol Spectrosc ; 301: 122948, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37285746

RESUMEN

Brexpiprazole (BRX) is a new antipsychotic drug that recently was used in the treatment of schizophrenia and other psychosis. The presence of benzothiophene ring in its chemical structure makes BRX naturally fluoresces. However, the native fluorescence of the drug was low in neutral or alkaline medium owing to the occurrence of photoinduced electron transfer (PET) from the nitrogen of the piperazine ring to the benzothiophene ring. Protonation of this nitrogen atom using sulfuric acid could efficiently block PET process and thus retaining the strong fluorescence of the compound. Accordingly, a straightforward, highly sensitive, fast and green spectrofluorimetric approach was established for BRX determination. In 1.0 M sulfuric acid solution, BRX exhibited significant native fluorescence measured at emission wavelength of 390 nm after excitation at 333 nm. ICH requirements were used to evaluate the method. The fluorescence intensity and BRX concentration were found to be correlated linearly within the range of 5-220 ng mL-1 with a coefficient of correlation 0.9999. The limit of quantitation was 2.38 ng mL-1 while limit of detection was 0.78 ng mL-1. The developed approach was successfully used to analyze BRX in biological fluids and pharmaceutical dosage form. The suggested approach worked well when applied for testing the uniformity of content.


Asunto(s)
Electrones , Humanos , Espectrometría de Fluorescencia/métodos , Preparaciones Farmacéuticas
20.
J Pharm Biomed Anal ; 229: 115322, 2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37001276

RESUMEN

A simple, rapid and selective thin layer chromatographic method has been developed for estimation of the antihypotension drug, midodrine hydrochloride, in pure form, tablet, spiked plasma and artificially degraded samples. Separation was carried out using silica gel 60-F254 as a stationary and mobile phase consisting of methanol: methylene chloride: ammonia in ratio of 8:2:0.2. The detection was carried out at wavelength of 290 nm. The retardation factor was found to be 0.7 and 0.49 for midodrine and its main degradation product desglymidodrine. The method showed linearity for midodrine over a concentration range of 50-1500 ng/spot with good correlation and determination coefficient. The method was applied successfully for analysis of commercial tablets and oral drops with good recovery and without interference of excipients. The method also was applied for studying the stability of the cited drug under different stress conditions including acidic, alkaline, hydrolytic, oxidative and photo- degradations. Furthermore, the kinetic of acidic and alkaline degradations was investigated and the rate constants were found to be 0.620 and 0.074 K h-1 while half life time (t1/2) values were 1.12 and 9.32 h, respectively.


Asunto(s)
Midodrina , Humanos , Comprimidos/química , Metanol , Cinética , Estabilidad de Medicamentos , Cromatografía en Capa Delgada/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA