2.
Heart Rhythm ; 19(3): 443-447, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34767989

RESUMEN

BACKGROUND: Implantable loop recorders (ILRs) are effective in achieving symptom-rhythm correlation. Data on the diagnostic yield of ILRs, on nurse-led syncope clinics, and on nurse-led ILR implants are limited. OBJECTIVE: We evaluated the safety and efficacy of our nurse-led syncope clinic and nurse-led ILR implants. METHODS: A retrospective study of all consecutive patients undergoing nurse-led ILR implantations was performed between April 2016 and April 2018. Patients were referred from both nurse-led and physician-led clinics. Data were collected on baseline demographic characteristics, referral source, symptom-rhythm correlation, ILR findings, and subsequent changes to management. All ILRs were enrolled into remote monitoring with automatic arrhythmia detection, and all immediate (≤24 hours) ILR implant complications were recorded. Comparisons were made between nurse-led and physician-led clinics and subsequent outcomes. RESULTS: A total of 432 patients with an ILR were identified: 164 (38%) from nurse-led and 268 (62%) from physician-led clinics; 200 (46%) were women (mean age 66.5 ± 18.2 years; mean follow-up duration 28.9 ± 9.5 months). Primary ILR indications were syncope (n = 251 [58%]), presyncope (n = 33 [7%]), palpitation (n = 39 [9%]), cryptogenic stroke (n = 78 [18%]), and other reasons (n = 31 [7%]). No immediate ILR implant complications occurred. Overall, 156 patients (36%) had a change in management as a direct result of ILR findings, with no overall differences between nurse-led and physician-led clinics (35% vs 36%; P = .7). More patients had newly diagnosed atrial fibrillation in physician-led clinics (15% vs 7%; P = .01), and more patients had pacemaker implants for bradycardia in nurse-led clinics (23% vs 13%; P < .01). CONCLUSION: Nurse-led ILR implantation was safe and effective. Nurse-led syncope clinics achieved good symptom-rhythm correlation with resultant significant changes to management in comparison to physician-led clinics. Larger prospective studies are needed to evaluate their longer-term impact.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Electrocardiografía Ambulatoria/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rol de la Enfermera , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Síncope/diagnóstico , Síncope/etiología , Síncope/terapia
3.
J Arrhythm ; 37(6): 1522-1531, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34887957

RESUMEN

BACKGROUND: Transvenous lead extraction (TLE) for implantable cardiac-devices is traditionally performed under general anesthesia (GA). This can lead to greater risk of exposure to COVID-19, longer recovery-times and increased procedural-costs. We report the feasibility/safety of TLE using conscious-sedation alone with immediate GA/cardiac-surgery back-up if needed. METHODS: Retrospective case-series of consecutive TLEs performed using conscious-sedation alone between March 2016 and December 2019. All were performed in the electrophysiology-laboratory using intravenous Fentanyl, Midazolam/Diazepam with a stepwise approach using locking-stylets/cutting-sheaths, including mechanical-sheaths. Baseline patient-characteristics, procedural-details and TLE outcomes (including procedure-related complications/death) were recorded. RESULTS: A total of 130 leads were targeted in 54 patients, mean age ± SD 74.6 ± 11.8years, 47(87%) males; dual-chamber pacemakers (n = 26; 48%), cardiac resynchronization therapy-defibrillators (n = 17; 31%) and defibrillators (n = 8; 15%) were commonest extracted devices. Mean ± SD/median (range) lead-dwell times were 11.0 ± 8.8/8.3 (0.3-37) years, respectively. Extraction indications included systemic infection (n = 23; 43%) and lead/pulse-generator erosion (n = 27; 50%); mean 2.1 ± 2.0 leads were removed per procedure/mean procedure-time was 100 ± 54 min. Local anesthetic (LA) was used for all (mean-dose: 33 ± 8 ml 1% lidocaine), IV drug-doses used (mean ± SD) were: midazolam: 3.95 ± 2.44 mg, diazepam: 4.69 ± 0.89 mg and fentanyl: 57 ± 40 µg. Complete lead-extraction was achieved in 110 (85%) leads, partial lead-extraction (<4 cm-fragment remaining) in 5 (4%) leads. Sedation-related hypotension requiring IV fluids occurred in 2 (managed without adverse-consequences) and hypoxia requiring additional airway-management in none. No procedural deaths occurred, one patient required emergency cardiac surgery for localized ventricular perforation, nine had minor complications (transient hypotension/bradycardia/pericardial effusion not requiring intervention). CONCLUSION: TLE undertaken using LA/conscious-sedation was safe/feasible in our series and associated with good clinical outcome/low procedural complications. Reduced risk of aerosolization of COVID-19 and quicker patient recovery/reduced anesthetic risk are potential benefits that warrant further study.

4.
Int J Cardiol ; 322: 170-174, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33002522

RESUMEN

BACKGROUND: Catheter ablation for complex left-atrial arrhythmia is increasing worldwide with many centres admitting patients overnight. Same-day procedures using conscious sedation carry significant benefits to patients/healthcare providers but data are limited. We evaluated the safety and cost-effectiveness of same-day complex left-atrial arrhythmia ablation. METHOD: Multi-centre retrospective cohort study of all consecutive complex elective left-atrial ablation procedures performed between January 2011 and December 2019. Data were collected on planned same-day discharge versus overnight stay, baseline parameters, procedure details/success, ablation technology, post-operative complications, unplanned overnight admissions/outcomes at 4-months and mortality up to April 2020. A cost analysis of potential savings was also performed. RESULTS: A total of 967 consecutive patients underwent complex left-ablation using radiofrequency (point-by-point ablation aided by 3D-mapping or PVAC catheter ablation with fluoroscopic screening) or cryoballoon-ablation (mean age: 60.9 ± 11.6 years, range 23-83 yrs., 572 [59%] females). The majority of patients had isolation of pulmonary veins alone (n = 846, 87%) and most using conscious-sedation alone (n = 921, 95%). Of the total cohort, 414 (43%) had planned same-day procedure with 35 (8%) admitted overnight due to major (n = 5) or minor (n = 30) complications. Overall acute procedural success-rate was 96% (n = 932). Complications in planned overnight-stay/same-day cohorts were low. At 4-month follow-up there were 62 (6.4%) readmissions (femoral haematomas, palpitation, other reasons); there were 3 deaths at mean follow-up of 42.0 ± 27.6 months, none related to the procedure. Overnight stay costs £350; the same-day ablation policy over this period would have saved £310,450. CONCLUSIONS: Same-day complex left-atrial catheter ablation using conscious sedation is safe and cost-effective with significant benefits for patients and healthcare providers. This is especially important in the current financial climate and Covid-19 pandemic.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios/economía , Arritmias Cardíacas/cirugía , Ablación por Catéter/economía , Análisis Costo-Beneficio , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Ambulatorios/efectos adversos , Ablación por Catéter/efectos adversos , Estudios de Cohortes , Femenino , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
5.
Eur Heart J Case Rep ; 4(6): 1-5, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33442609

RESUMEN

BACKGROUND: Circulatory collapse during/post-pulmonary vein (PV) isolation by cryo-balloon ablation is a Cardiology emergency that has multiple potential causes and requires a methodical investigative approach. Some of the complications that can arise include cardiac tamponade, bleeding/vascular injury, anaphylaxis, Addisonian crisis, acute pulmonary embolism, acute PV stenosis, oesophageal injury, and vagal reaction. CASE SUMMARY: Here, we present a case of a 76-year-old lady who developed profound circulatory collapse during an elective pulmonary vein isolation by cryo-balloon ablation for symptomatic paroxysmal atrial fibrillation (AF). Cardiac tamponade, bleeding/vascular injury, and other less common causes were excluded. She only responded transiently to fluid resuscitation and developed intermittent bradyarrhythmias and hypotension which responded to isoprenaline. She was discharged home at Day 3 post-AF ablation after remaining well and continued to do so at follow-up. DISCUSSION: Circulatory collapse during/post-PV cryo-balloon ablation is a Cardiology emergency that has multiple potential causes. The ganglionate plexi form part of the cardiac intrinsic autonomic nervous system (ANS) and are located close to the left atrial-PV junctions. The presence of vagal response has been observed to be a marker of ANS modulation although its significance on the long-term outcome post-ablation has yet to be elucidated. The true cause of our patient's profound circulatory collapse is uncertain but a vital learning point in this case is the systematic exclusion of common and potentially life-threatening complications following AF ablation. A persistent vagal reaction secondary to PV cryo-balloon ablation can usually be managed with supportive medical therapy as demonstrated in our case.