Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Pediatr ; 10: 772142, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35601426

RESUMEN

Prior computational and imaging studies described changes in flow patterns for patients with Marfan syndrome, but studies are lacking for related populations. This pilot study addresses this void by characterizing wall shear stress (WSS) indices for patients with Loeys-Dietz and undifferentiated connective tissue diseases. Using aortic valve-based velocity profiles from magnetic resonance imaging as input to patient-specific fluid structure interaction (FSI) models, we determined local flow patterns throughout the aorta for four patients with various connective tissue diseases (Loeys-Dietz with the native aorta, connective tissue disease of unclear etiology with native aorta in female and male patients, and an untreated patient with Marfan syndrome, as well as twin patients with Marfan syndrome who underwent valve-sparing root replacement). FSI simulations used physiological boundary conditions and material properties to replicate available measurements. Time-averaged WSS (TAWSS) and oscillatory shear index (OSI) results are presented with localized comparison to age- and gender-matched control participants. Ascending aortic dimensions were greater in almost all patients with connective tissue diseases relative to their respective control. Differences in TAWSS and OSI were driven by local morphological differences and cardiac output. For example, the model for one twin had a more pronounced proximal descending aorta in the vicinity of the ductus ligamentum that impacted WSS indices relative to the other. We are optimistic that the results of this study can serve as a foundation for larger future studies on the connective tissue disorders presented in this article.

2.
Interv Neuroradiol ; 24(2): 150-161, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29239685

RESUMEN

Background and purpose Data differentiating flow diversion properties of commercially available low- and high-porosity stents are limited. This in vitro study applies angiographic analysis of intra-aneurysmal flow to compare the flow-diversion performance of five neurovascular devices in idealized sidewall and bifurcation aneurysm models. Methods Five commercial devices (Enterprise, Neuroform, LVIS, FRED, and Pipeline) were implanted in silicone sidewall and bifurcation aneurysm models under physiological average flow of blood analog fluid. High-speed angiographic images were acquired pre- and post-device implantation and contrast concentration-time curves within the aneurysm were recorded. The curves were quantified with five parameters to assess changes in contrast transport, and thus aneurysm hemodynamics, due to each device. Results Inter-device flow-diversion performance was more easily distinguished in the sidewall model than the bifurcation model. There were no obvious overall statistical trends in the bifurcation parameters but the Pipeline performed marginally better than the other devices. In the sidewall geometry, overall evidence suggests that the LVIS performed better than the Neuroform and Enterprise. The Pipeline and FRED devices were statistically superior to the three stents and Pipeline was superior to FRED in all sidewall parameters evaluated. Conclusions Based on this specific set of experiments, lower-porosity flow diverters perform significantly better in reducing intra-aneurysmal flow activity than higher-porosity stents in sidewall-type geometries. The LVIS device is potentially a better flow diverter than the Neuroform and Enterprise devices, while the Pipeline is potentially better than the FRED.


Asunto(s)
Prótesis Vascular , Angiografía Cerebral , Medios de Contraste/farmacocinética , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Yohexol/análogos & derivados , Diseño de Prótesis , Stents , Velocidad del Flujo Sanguíneo , Fluoroscopía , Técnicas In Vitro , Yohexol/farmacocinética , Modelos Anatómicos , Porosidad , Impresión Tridimensional
3.
Pediatr Cardiol ; 35(4): 732-40, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24259013

RESUMEN

Patients with coarctation of the aorta (CoA) are prone to morbidity including atherosclerotic plaque that has been shown to correlate with altered wall shear stress (WSS) in the descending thoracic aorta (dAo). We created the first patient-specific computational fluid dynamics (CFD) model of a CoA patient treated by Palmaz stenting to date, and compared resulting WSS distributions to those from virtual implantation of Genesis XD and modified NuMED CP stents, also commonly used for CoA. CFD models were created from magnetic resonance imaging, fluoroscopy and blood pressure data. Simulations incorporated vessel deformation, downstream vascular resistance and compliance to match measured data and generate blood flow velocity and time-averaged WSS (TAWSS) results. TAWSS was quantified longitudinally and circumferentially in the stented region and dAo. While modest differences were seen in the distal portion of the stented region, marked differences were observed downstream along the posterior dAo and depended on stent type. The Genesis XD model had the least area of TAWSS values exceeding the threshold for platelet aggregation in vitro, followed by the Palmaz and NuMED CP stents. Alterations in local blood flow patterns and WSS imparted on the dAo appear to depend on the type of stent implanted for CoA. Following confirmation in larger studies, these findings may aid pediatric interventional cardiologists in selecting the most appropriate stent for each patient, and ultimately reduce long-term morbidity following treatment for CoA by stenting.


Asunto(s)
Aorta Torácica/fisiopatología , Coartación Aórtica/fisiopatología , Prótesis Vascular , Simulación por Computador , Hemodinámica/fisiología , Modelos Cardiovasculares , Stents , Adolescente , Angiografía , Coartación Aórtica/diagnóstico , Coartación Aórtica/cirugía , Elasticidad , Humanos , Imagen por Resonancia Cinemagnética , Diseño de Prótesis , Resistencia Vascular
4.
J Pharmacol Toxicol Methods ; 65(1): 18-28, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22079597

RESUMEN

INTRODUCTION: Coarctation of the aorta (CoA) is associated with morbidity despite treatment. Although mechanisms remain elusive, abnormal hemodynamics and vascular biomechanics are implicated. We present a novel approach that facilitates quantification of coarctation-induced mechanical alterations and their impact on vascular structure and function, without genetic or confounding factors. METHODS: Rabbits underwent thoracic CoA at 10weeks of age (~9 human years) to induce a 20mmHg blood pressure (BP) gradient using permanent or dissolvable suture thereby replicating untreated and corrected CoA. Computational fluid dynamics (CFD) was performed using imaging and BP data at 32weeks to quantify velocity, strain and wall shear stress (WSS) for comparison to vascular structure and function as revealed by histology and myograph results. RESULTS: Systolic and mean BP was elevated in CoA compared to corrected and control rabbits leading to vascular thickening, disorganization and endothelial dysfunction proximally and distally. Corrected rabbits had less severe medial thickening, endothelial dysfunction, and stiffening limited to the proximal region despite 12weeks of normal BP (~4 human years) after the suture dissolved. WSS was elevated distally for CoA rabbits, but reduced for corrected rabbits. DISCUSSION: These findings are consistent with alterations in humans. We are now poised to investigate mechanical contributions to mechanisms of morbidity in CoA using these methods.


Asunto(s)
Aorta Torácica/fisiopatología , Coartación Aórtica/fisiopatología , Presión Sanguínea , Animales , Simulación por Computador , Modelos Animales de Enfermedad , Endotelio Vascular/patología , Hemodinámica , Hidrodinámica , Masculino , Miografía , Conejos , Factores de Tiempo
5.
Congenit Heart Dis ; 6(5): 432-43, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21801315

RESUMEN

BACKGROUND: Atherosclerotic plaque in the descending thoracic aorta (dAo) is related to altered wall shear stress (WSS) for normal patients. Resection with end-to-end anastomosis (RWEA) is the gold standard for coarctation of the aorta (CoA) repair, but may lead to altered WSS indices that contribute to morbidity. METHODS: Computational fluid dynamics (CFD) models were created from imaging and blood pressure data for control subjects and age- and gender-matched CoA patients treated by RWEA (four males, two females, 15 ± 8 years). CFD analysis incorporated downstream vascular resistance and compliance to generate blood flow velocity, time-averaged WSS (TAWSS), and oscillatory shear index (OSI) results. These indices were quantified longitudinally and circumferentially in the dAo, and several visualization methods were used to highlight regions of potential hemodynamic susceptibility. RESULTS: The total dAo area exposed to subnormal TAWSS and OSI was similar between groups, but several statistically significant local differences were revealed. Control subjects experienced left-handed rotating patterns of TAWSS and OSI down the dAo. TAWSS was elevated in CoA patients near the site of residual narrowings and OSI was elevated distally, particularly along the left dAo wall. Differences in WSS indices between groups were negligible more than 5 dAo diameters distal to the aortic arch. CONCLUSIONS: Localized differences in WSS indices within the dAo of CoA patients treated by RWEA suggest that plaque may form in unique locations influenced by the surgical repair. These regions can be visualized in familiar and intuitive ways allowing clinicians to track their contribution to morbidity in longitudinal studies.


Asunto(s)
Aorta Torácica/cirugía , Coartación Aórtica/cirugía , Simulación por Computador , Hemodinámica , Modelos Cardiovasculares , Procedimientos Quirúrgicos Vasculares , Adolescente , Anastomosis Quirúrgica , Aorta Torácica/fisiopatología , Coartación Aórtica/diagnóstico , Coartación Aórtica/fisiopatología , Aterosclerosis/etiología , Aterosclerosis/fisiopatología , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Estudios de Casos y Controles , Niño , Preescolar , Adaptabilidad , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Flujo Sanguíneo Regional , Estrés Mecánico , Resultado del Tratamiento , Resistencia Vascular , Procedimientos Quirúrgicos Vasculares/efectos adversos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA