Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Nutr Metab Cardiovasc Dis ; 28(4): 335-342, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29428572

RESUMEN

BACKGROUND AND AIM: The objective of this cross-sectional study was to evaluate the degree of glycaemic control and the frequency of diabetic complications in Italian people with diabetes who were treated with continuous subcutaneous insulin infusion (CSII). METHODS AND RESULTS: Questionnaires investigating the organisation of diabetes care centres, individuals' clinical and metabolic features and pump technology and its management were sent to adult and paediatric diabetes centres that use CSII for treatment in Italy. Information on standard clinical variables, demographic data and acute and chronic diabetic complications was derived from local clinical management systems. The sample consisted of 6623 people with diabetes, which was obtained from 93 centres. Of them, 98.8% had type 1 diabetes mellitus, 57.2% were female, 64% used a conventional insulin pump and 36% used a sensor-augmented insulin pump. The median glycated haemoglobin (HbA1c) level was 60 mmol/mol (7.6%). The HbA1c target (i.e. <58 mmol/mol for age <18 years and <53 mmol/mol for age >18 years) was achieved in 43.4% of paediatric and 23% of adult participants. Factors such as advanced pump functions, higher rate of sensor use, pregnancy in the year before the study and longer duration of diabetes were associated with lower HbA1c levels. The most common chronic complications occurring in diabetes were retinopathy, microalbuminuria and hypertension. In the year before the study, 5% of participants reported ≥1 episode of severe hypoglycaemic (SH) episodes (SH) and 2.6% reported ≥1 episode of ketoacidosis. CONCLUSIONS: Advanced personal skills and use of sensor-based pump are associated with better metabolic control outcomes in Italian people with diabetes who were treated with CSII. The reduction in SH episodes confirms the positive effect of CSII on hypoglycaemia. CLINICAL TRIAL REGISTRATION NUMBER: NCT 02620917 (ClinicalTrials.gov).


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adolescente , Adulto , Albuminuria/epidemiología , Biomarcadores/sangre , Glucemia/metabolismo , Niño , Estudios Transversales , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiología , Nefropatías Diabéticas/epidemiología , Retinopatía Diabética/epidemiología , Femenino , Hemoglobina Glucada/metabolismo , Encuestas de Atención de la Salud , Humanos , Hipertensión/epidemiología , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemiantes/efectos adversos , Infusiones Subcutáneas , Insulina/efectos adversos , Sistemas de Infusión de Insulina/efectos adversos , Italia/epidemiología , Cetosis/epidemiología , Masculino , Persona de Mediana Edad , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
Diabetes Technol Ther ; 17(2): 96-104, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25479035

RESUMEN

BACKGROUND: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. MATERIALS AND METHODS: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. RESULTS: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+nurse+dietician+psychologist) was available in 23% of adult-care diabetes centers and in 53% of pediatric diabetes units. CONCLUSIONS: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Adhesión a Directriz/estadística & datos numéricos , Hipoglucemiantes/administración & dosificación , Infusiones Subcutáneas/estadística & datos numéricos , Insulina/administración & dosificación , Pautas de la Práctica en Medicina/estadística & datos numéricos , Adulto , Glucemia , Niño , Análisis Costo-Beneficio , Diabetes Mellitus Tipo 1/epidemiología , Femenino , Encuestas de Atención de la Salud , Humanos , Italia/epidemiología , Masculino , Encuestas y Cuestionarios
3.
Diabetes Technol Ther ; 15(4): 328-34, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23537417

RESUMEN

OBJECTIVES: An optimized metabolic control during delivery is mandatory to prevent maternal-neonatal complications. The primary aim of this study was to evaluate the efficacy and safety of continuous subcutaneous insulin infusion (CSII) during delivery in pregnant women with type 1 diabetes. The secondary aim was to assess the impact of real-time continuous glucose monitoring (RT-CGM) added to CSII versus CSII alone. RESEARCH DESIGN AND METHODS: This was a multicenter observational retrospective study. A standardized protocol, to use CSII throughout pregnancy and delivery, foresaw three different insulin basal rates according to blood glucose level: profile A, the last basal rate in use; profile B, preventive 50% reduction of the last basal rate in use; and profile C, 0.1-0.2 U/h for blood glucose level <70 mg/dL, activated just before anesthesia or at the beginning of active labor. An alternative intravenous protocol (IVP) was given in case of complications and relevant metabolic deterioration. Blood glucose in the target range (70-140 mg/dL) throughout delivery and percentage of activation of the IVP were primary outcomes. RESULTS: Sixty-five pregnant women with diabetes included in the study (56-86% cesarean section; 9-14% spontaneous/stimulated vaginal delivery). Mean blood glucose level was 102 ± 31 mg/dL at 0 min, 109 ± 42 mg/dL at 30 min, 120 ± 48 mg/dL at 60 min, and 99 ± 34 mg/dL at 24 h. Mean basal rate during delivery was 0.6 ± 0.4 U/h (profile B). Mean capillary blood glucose (CBG) level was lower in the RT-CGM group relative to the CSII-alone group: 80 ± 14 mg/dL versus 111 ± 32 mg/dL at 0 min (P<0.01), 79 ± 11 mg/dL versus 109 ± 42 mg/dL at 30 min (P<0.02), and 98 ± 20 mg/dL versus 125 ± 51 mg/dL at 60 min (difference not significant). Eleven newborns experienced transient neonatal hypoglycemia. None of the women switched to IVP. No major differences were observed according to delivery procedure. CONCLUSIONS: CSII is possible and safe in different types of delivery in selected and educated women. RT-CGM helps to obtain better outcomes in terms of maternal peripartum CBG level.


Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Hipoglucemia/sangre , Hipoglucemiantes/administración & dosificación , Infusiones Subcutáneas/métodos , Insulina/administración & dosificación , Embarazo en Diabéticas/sangre , Adulto , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Cesárea/estadística & datos numéricos , Parto Obstétrico/estadística & datos numéricos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Femenino , Humanos , Hipoglucemia/tratamiento farmacológico , Hipoglucemia/epidemiología , Recién Nacido , Insulina/sangre , Sistemas de Infusión de Insulina , Italia/epidemiología , Embarazo , Resultado del Embarazo , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/epidemiología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...