Int J Radiat Biol ; 100(7): 1019-1028, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38810111

RESUMEN

PURPOSE: This interlaboratory comparison was conducted to evaluate the performance of the Latin-American Biodosimetry Network (LBDNet) in analyzing digitized images for scoring dicentric chromosomes from in vitro irradiated blood samples. The exercise also assessed the use of weighted robust algorithms to compensate the uneven expertise among the participating laboratories. METHODS: Three sets of coded images obtained through the dicentric chromosome assay from blood samples irradiated at 1.5 Gy (sample A) and 4 Gy (sample B), as well as a non-irradiated whole blood sample (sample C), were shared among LBDNet laboratories. The images were captured using the Metafer4 platform coupled with the AutoCapt module. The laboratories were requested to perform triage scoring, conventional scoring, and dose estimation. The dose estimation was carried out using either their laboratory calibration curve or a common calibration curve. A comparative statistical analysis was conducted using a weighted robust Hampel algorithm and z score to compensate for uneven expertise in dicentric analysis and dose assessment among all laboratories. RESULTS: Out of twelve laboratories, one had unsatisfactory estimated doses at 0 Gy, and two had unsatisfactory estimated doses at 1.5 Gy when using their own calibration curve and triage scoring mode. However, all doses were satisfactory at 4 Gy. Six laboratories had estimated doses within 95% uncertainty limits at 0 Gy, seven at 1.5 Gy, and four at 4 Gy. While the mean dose for sample C was significantly biased using robust algorithms, applying weights to compensate for the laboratory's analysis expertise reduced the bias by half. The bias from delivered doses was only notable for sample C. Using the common calibration curve for dose estimation reduced the standard deviation (s*) estimated by robust methods for all three samples. CONCLUSIONS: The results underscore the significance of performing interlaboratory comparison exercises that involve digitized and electronically transmitted images, even when analyzing non-irradiated samples. In situations where the participating laboratories possess different levels of proficiency, it may prove essential to employ weighted robust algorithms to achieve precise outcomes.


Asunto(s)
Aberraciones Cromosómicas , Humanos , Aberraciones Cromosómicas/efectos de la radiación , Algoritmos , Laboratorios/normas , Radiometría/métodos , Procesamiento de Imagen Asistido por Computador/métodos
2.
Int J Radiat Biol ; 99(3): 431-438, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35759221

RESUMEN

PURPOSE: To test the performance of different algorithms that can be used in inter-laboratory comparisons based on dicentric chromosome analysis, and to evaluate the impact of considering a priori values different to calculate individual laboratory performance based on the ionizing radiation dose estimation. METHODS: Mean and standard deviation estimations in inter-laboratory comparisons are tested on simulated data and data from previously published inter-laboratory comparisons using three robust algorithms, Algorithm A, Algorithm B and Q/Hampel, all programmed in R-project language and implemented in a Shiny application. The simulated data were generated assuming three different probabilities to contaminate inter-laboratory comparisons samples with atypical dose values. Comparison between different algorithms was also done using published exercises where blood samples were irradiated at 0 and 0.7 Gy that represent a challenge for the assessment of an inter-laboratory comparison. RESULTS: The best performance was obtained with the Q/Hampel algorithm for the estimation of the dose mean and with the Algorithm B for the estimation of the dose standard deviation under the conditions tested in the simulations. The Q/Hampel algorithm showed the best performance when non-irradiated samples were evaluated and there was a high proportion of identical values. The presence identical values cause the Algorithm B to fail. Real examples illustrating the need to consider standard deviation priors, and the need to use algorithms resistant to a high proportion of identical values are presented. CONCLUSIONS: Q/Hampel algorithm is a serious candidate to estimate the dose mean in the inter-laboratory comparisons, and to estimate both parameters when the proportion of identical values equals or higher than the half of the results. When the proportion of identical values is less than the half of the results, the Algorithm B should be considered as a candidate to estimate the standard deviation in the inter-laboratory comparisons with small number of laboratories. We remark that special attention is needed to establish prior definitions of standard deviation in the assessment of inter-laboratory dicentric assay comparisons.


Asunto(s)
Bioensayo , Aberraciones Cromosómicas , Humanos , Bioensayo/métodos , Radiación Ionizante
3.
Radiat Prot Dosimetry ; 172(1-3): 218-222, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27473695

RESUMEN

Mitotic Index (MI) estimation expressed as percentage of mitosis plays an important role as quality control endpoint. To this end, MI is applied to check the lot of media and reagents to be used throughout the assay and also to check cellular viability after blood sample shipping, indicating satisfactory/unsatisfactory conditions for the progression of cell culture. The objective of this paper was to apply the CellProfiler open-source software for automatic detection of mitotic and nuclei figures from digitized images of cultured human lymphocytes for MI assessment, and to compare its performance to that performed through semi-automatic and visual detection. Lymphocytes were irradiated and cultured for mitosis detection. Sets of images from cultures were analyzed visually and findings were compared with those using CellProfiler software. The CellProfiler pipeline includes the detection of nuclei and mitosis with 80% sensitivity and more than 99% specificity. We conclude that CellProfiler is a reliable tool for counting mitosis and nuclei from cytogenetic images, saves considerable time compared to manual operation and reduces the variability derived from the scoring criteria of different scorers. The CellProfiler automated pipeline achieves good agreement with visual counting workflow, i.e. it allows fully automated mitotic and nuclei scoring in cytogenetic images yielding reliable information with minimal user intervention.


Asunto(s)
Bioensayo/métodos , Núcleo Celular/ultraestructura , Interpretación de Imagen Asistida por Computador/métodos , Microscopía/métodos , Mitosis/genética , Índice Mitótico/métodos , Radiometría/métodos , Núcleo Celular/efectos de la radiación , Mitosis/efectos de la radiación , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos
4.
PLoS Genet ; 12(1): e1005792, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26765540

RESUMEN

Fanconi Anemia (FA) is a rare autosomal recessive disorder characterized by hypersensitivity to inter-strand crosslinks (ICLs). FANCD2, a central factor of the FA pathway, is essential for the repair of double strand breaks (DSBs) generated during fork collapse at ICLs. While lesions different from ICLs can also trigger fork collapse, the contribution of FANCD2 to the resolution of replication-coupled DSBs generated independently from ICLs is unknown. Intriguingly, FANCD2 is readily activated after UV irradiation, a DNA-damaging agent that generates predominantly intra-strand crosslinks but not ICLs. Hence, UV irradiation is an ideal tool to explore the contribution of FANCD2 to the DNA damage response triggered by DNA lesions other than ICL repair. Here we show that, in contrast to ICL-causing agents, UV radiation compromises cell survival independently from FANCD2. In agreement, FANCD2 depletion does not increase the amount of DSBs generated during the replication of UV-damaged DNA and is dispensable for UV-induced checkpoint activation. Remarkably however, FANCD2 protects UV-dependent, replication-coupled DSBs from aberrant processing by non-homologous end joining, preventing the accumulation of micronuclei and chromatid aberrations including non-homologous chromatid exchanges. Hence, while dispensable for cell survival, FANCD2 selectively safeguards chromosomal stability after UV-triggered replication stress.


Asunto(s)
Reparación del ADN/genética , Replicación del ADN/genética , Proteína del Grupo de Complementación D2 de la Anemia de Fanconi/genética , Anemia de Fanconi/genética , Cromátides/genética , Cromátides/efectos de la radiación , Inestabilidad Cromosómica/efectos de la radiación , Cromosomas/genética , Cromosomas/efectos de la radiación , Roturas del ADN de Doble Cadena/efectos de los fármacos , Daño del ADN/efectos de la radiación , Reparación del ADN por Unión de Extremidades/genética , Reparación del ADN por Unión de Extremidades/efectos de la radiación , Reparación del ADN/efectos de la radiación , Replicación del ADN/efectos de la radiación , Anemia de Fanconi/patología , Inestabilidad Genómica/genética , Inestabilidad Genómica/efectos de la radiación , Humanos , ARN Interferente Pequeño , Rayos Ultravioleta
5.
Radiat Prot Dosimetry ; 159(1-4): 3-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24743754

RESUMEN

It has been observed that victims of accidental overexposures show better chance of survival if they receive medical treatment early. The increased risk of scenarios involving mass casualties has stimulated the scientific community to develop tools that would help the medical doctors to treat victims. The biological dosimetry has become a routine test to estimate the dose, supplementing physical and clinical dosimetry. In case of radiation emergencies, in order to provide timely and effectively biological dosimetry assistance it is essential to guarantee an adequate transport of blood samples in principal, for providing support to countries that do not have biodosimetry laboratories. The objective of the present paper is to provide general guidelines, summarised in 10 points, for timely and proper receiving and sending of blood samples under National and International regulations, for safe and expeditious international transport. These guidelines cover the classification, packaging, marking, labelling, refrigeration and documentation requirements for the international shipping of blood samples and pellets, to provide assistance missions with a tool that would contribute with the preparedness for an effective biodosimetric response in cases of radiological or nuclear emergencies.


Asunto(s)
Carga Corporal (Radioterapia) , Guías como Asunto , Traumatismos por Radiación/diagnóstico , Radiometría/métodos , Medición de Riesgo , Administración de la Seguridad/métodos , Transportes , Humanos , Agencias Internacionales , Factores de Tiempo