Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 10(5)2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37237694

RESUMEN

This work presents the development of an automatic and customized measuring system employing sigma-delta analog-to-digital converters and transimpedance amplifiers for precise measurements of voltage and current signals generated by microbial fuel cells (MFCs). The system can perform multi-step discharge protocols to accurately measure the power output of MFCs, and has been calibrated to ensure high precision and low noise measurements. One of the key features of the proposed measuring system is its ability to conduct long-term measurements with variable time steps. Moreover, it is portable and cost-effective, making it ideal for use in laboratories without sophisticated bench instrumentation. The system is expandable, ranging from 2 to 12 channels by adding dual-channel boards, which allows for testing of multiple MFCs simultaneously. The functionality of the system was tested using a six-channel setup, and the results demonstrated its ability to detect and distinguish current signals from different MFCs with varying output characteristics. The power measurements obtained using the system also allow for the determination of the output resistance of the MFCs being tested. Overall, the developed measuring system is a useful tool for characterizing the performance of MFCs, and can be helpful in the optimization and development of sustainable energy production technologies.

2.
Biosensors (Basel) ; 12(7)2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35884333

RESUMEN

We apply surface-enhanced infrared absorption (SEIRA) spectroscopy to monitor the denaturation process of a surface-bound protein A monolayer. Our proposed platform relies on a plasmonic metasurface comprising different spatial subregions ("pixels") that are engineered to exhibit different resonances covering the infrared region of the electromagnetic spectrum that is matched to the vibrational modes of the Amide groups. Specifically, we are able to determine changes in the Amide I and Amide II vibration coupled modes, by comparing the SEIRA reflectance spectra pertaining to the native state and a denatured state induced by a pH variation. In particular, we observe some evident red-shifts in the principal Amide I mode and the Amide II vibration coupled modes (attributable to the breaking of hydrogen bonds), which result in insurmountable barriers for refolding. Thanks to the strong field localization, and consequent enhancement of the light-matter interactions, our proposed sensing platform can operate with extremely small amounts of an analyte, with an estimated detection limit of about 3 femtomoles of molecules.


Asunto(s)
Amidas , Proteína Estafilocócica A , Espectrofotometría Infrarroja/métodos
3.
Biosensors (Basel) ; 12(5)2022 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-35624565

RESUMEN

The need for miniaturized biological sensors which can be easily integrated into medical needles and catheters for in vivo liquid biopsies with ever-increasing performances has stimulated the interest of researchers in lab-on-fiber (LOF) technology. LOF devices arise from the integration of functional materials at the nanoscale on the tip of optical fibers, thus endowing a simple optical fiber with advanced functionalities and enabling the realization of high-performance LOF biological sensors. Consequently, in 2017, we demonstrated the first optical fiber meta-tip (OFMT), consisting of the integration of plasmonic metasurfaces (MSs) on the optical fiber end-face which represented a major breakthrough along the LOF technology roadmap. Successively, we demonstrated that label-free biological sensors based on the plasmonic OFMT are able to largely overwhelm the performance of a standard plasmonic LOF sensor, in view of the extraordinary light manipulation capabilities of plasmonic array exploiting phase gradients. To further improve the overall sensitivity, a labelled sensing strategy is here suggested. To this end, we envision the possibility to realize a novel class of labelled LOF optrodes based on OFMT, where an all-dielectric MS, designed to enhance the fluorescence emission by a labelled target molecule, is integrated on the end-face of a multimode fiber (MMF). We present a numerical environment to compute the fluorescence enhancement factor collected by the MMF, when on its tip a Silicon MS is laid, consisting of an array of cylindrical nanoantennas, or of dimers or trimers of cylindrical nanoantennas. According to the numerical results, a suitable design of the dielectric MS allows for a fluorescence enhancement up to three orders of magnitudes. Moreover, a feasibility study is carried out to verify the possibility to fabricate the designed MSs on the termination of multimode optical fibers using electron beam lithography followed by reactive ion etching. Finally, we analyze a real application scenario in the field of biosensing and evaluate the degradation in the fluorescence enhancement performances, taking into account the experimental conditions. The present work, thus, provides the main guidelines for the design and development of advanced LOF devices based on the fluorescence enhancement for labelled biosensing applications.


Asunto(s)
Fibras Ópticas , Polímeros , Fluorescencia
4.
Front Bioeng Biotechnol ; 9: 666121, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34055762

RESUMEN

We propose and demonstrate a sensing platform based on plasmonic metasurfaces for the detection of very low concentrations of deoxyribo-nucleic acid (DNA) fragments. The platform relies on surface-enhanced infrared absorption spectroscopy, implemented via a multispectral metasurface. Specifically, different regions ("pixels") are engineered so as to separately cover the medium-infrared range of the electromagnetic spectrum extending from the functional-groups to the fingerprint region of a single analyte. In conjunction with a suitable bio-functionalization, this enables univocal and label-free recognition of specific molecules. For experimental validation, we fabricate a large-area gold metasurface on a silicon chip, and functionalize it with a recognition layer of peptide nucleic acid (PNA). Our experimental results indicate the possibility to detect complementary DNA fragments in concentrations as low as 50 fM, i.e., well below the value attained by standard methods, with additional advantages in terms of processing time, versatility and ease of implementation/operation.

5.
Sci Rep ; 8(1): 17841, 2018 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-30552352

RESUMEN

In this work, we report on the first demonstration of Lab on Fiber (LOF) dosimeter for ionizing radiation monitoring at ultra-high doses. The new dosimeter consists in a metallo-dielectric resonator at sub-wavelength scale supporting localized surface plasmon resonances realized on the optical fiber (OF) tip. The resonating structure involves two gold gratings separated by a templated dielectric layer of poly(methyl methacrylate) (PMMA). Two LOF prototypes have been manufactured and exposed at the IRRAD Proton Facility at CERN in Geneva to 23 GeV protons for a total fluence of 0.67 × 1016 protons/cm2, corresponding to an absorbed dose of 1.8 MGy. Experimental data demonstrated the "radiation resistance" feature of the LOF devices and a clear dependence of the reflected spectrum versus the total dose, expressed by a cumulative blue-shift of ~1.4 nm of the resonance combined with a slight increase of 0.16 dBm in the reflected spectrum. The numerical analysis carried out to correlate the experimental results with the dimensional and physical properties of the resonator, expected to be tightly connected to the absorbed dose, suggests that the main phenomenon induced by exposure to proton beam and able to explain the measured spectral behavior is the reduction of the PMMA thickness, which is also consistent with past literature in the field. Preliminary results demonstrated the potentiality of the proposed platform as dosimeter at MGy dose levels for high energy physics experiments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA