J Appl Clin Med Phys ; 23(5): e13619, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35481961

RESUMEN

Data driven respiratory gating (DDG) in positron emission tomography (PET) imaging extracts respiratory waveforms from the acquired PET data obviating the need for dedicated external devices. DDG performance, however, degrades with decreasing detected number of coincidence counts. In this paper, we assess the clinical impact of reducing injected activity on a new DDG algorithm designed for PET data acquired with continuous bed motion (CBM_DDG) by evaluating CBM_DDG waveforms, tumor quantification, and physician's perception of motion blur in resultant images. Forty patients were imaged on a Siemens mCT scanner in CBM mode. Reduced injected activity was simulated by generating list mode datasets with 50% and 25% of the original data (100%). CBM_DDG waveforms were compared to that of the original data over the range between the aortic arch and the center of the right kidney using the Pearson correlation coefficient (PCC). Tumor quantification was assessed by comparing the maximum standardized uptake value (SUVmax) and peak SUV (SUVpeak) of reconstructed images from the various list mode datasets using elastic motion deblurring (EMDB) reconstruction. Perceived motion blur was assessed by three radiologists of one lesion per patient on a continuous scale from no motion blur (0) to significant motion blur (3). The mean PCC of the 50% and 25% dataset waveforms was 0.74 ± 0.18 and 0.59 ± 0.25, respectively. In comparison to the 100% datasets, the mean SUVmax increased by 2.25% (p = 0.11) for the 50% datasets and by 3.91% (p = 0.16) for the 25% datasets, while SUVpeak changes were within ±0.25%. Radiologist evaluations of motion blur showed negligible changes with average values of 0.21, 0.3, and 0.28 for the 100%, 50%, and 25% datasets. Decreased injected activities degrades the resultant CBM_DDG respiratory waveforms; however this decrease has minimal impact on quantification and perceived image motion blur.


Asunto(s)
Neoplasias , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física) , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos
2.
J Appl Clin Med Phys ; 21(1): 158-165, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31816183

RESUMEN

Continuous bed motion (CBM) was recently introduced as an alternative to step-and-shoot (SS) mode for PET/CT data acquisition. In CBM, the patient is continuously advanced into the scanner at a preset speed, whereas in SS, the patient is imaged in overlapping bed positions. Previous investigations have shown that patients preferred CBM over SS for PET data acquisition. In this study, we investigated the effect of CBM versus SS on patient breathing and respiratory motion correction. One hundred patients referred for PET/CT were scanned using a Siemens mCT scanner. Patient respiratory waveforms were recorded using an Anzai system and analyzed using four methods: Methods 1 and 2 measured the coefficient of variation (COV) of the respiratory cycle duration (RCD) and amplitude (RCA). Method 3 measured the respiratory frequency signal prominence (RSP) and method 4 measured the width of the HDChest optimal gate (OG) window when using a 35% duty cycle. Waveform analysis was performed over the abdominothoracic region which exhibited the greatest respiratory motion and the results were compared between CBM and SS. Respiratory motion correction was assessed by comparing the ratios of SUVmax, SUVpeak, and CNR of focal FDG uptake, as well as Radiologists' visual assessment of corresponding image quality of motion corrected and uncorrected images for both acquisition modes. The respiratory waveforms analysis showed that the RCD and RCA COV were 3.7% and 33.3% lower for CBM compared to SS, respectively, while the RSP and OG were 30.5% and 2.0% higher, respectively. Image analysis on the other hand showed that SUVmax, SUVpeak, and CNR were 8.5%, 4.5%, and 3.4% higher for SS compared to CBM, respectively, while the Radiologists' visual comparison showed similar image quality between acquisition modes. However, none of the results showed statistically significant differences between SS and CBM, suggesting that motion correction is not impacted by acquisition mode.


Asunto(s)
Movimiento , Neoplasias/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/instrumentación , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Respiración , Técnicas de Imagen Sincronizada Respiratorias/normas , Femenino , Fluorodesoxiglucosa F18/metabolismo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico por imagen , Neoplasias/metabolismo , Pronóstico , Estudios Prospectivos , Radiofármacos/metabolismo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos
3.
Phys Med Biol ; 64(10): 105013, 2019 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-31026840

RESUMEN

Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to static-whole-body (SWB) PET. However, to achieve this improvement, QPG PET requires CT attenuation correction data that matches the QPG PET data. In this paper we investigated the effect of using free-breathing CT for attenuation correction of QPG PET on SUVmax and SUVpeak and compared the results to those of SWB PET. 34 lesions in 27 patients were included. All patients were injected with F-18 FDG. 4D-CT datasets representing all possible phases of respiration that could result from a free-breathing CT were acquired. The 4D-CT datasets were used for attenuation correction of the QPG and SWB PET data. Percentage change in the SUVmax and SUVpeak range was calculated for the reconstructions and compared between QPG and SWB PET. The mean percentage change in the lesion SUVmax and SUVpeak ranges were 19.1% (p  = 0.0178) and 25.2% (p  = 0.0002) higher for QPG compared to SWB, respectively. The maximum percent change in SUVmax and SUVpeak ranges were 58.5% and 59.0% for QPG, respectively compared to 46.1% and 45.3% for SWB, respectively. The highest SUVmax and SUVpeak measurements corresponded to the CT phase that matched the QPG phase. Utilizing free-breathing CT for attenuation correction can lead to large changes in quantification due to misalignment with PET data. This misalignment has a large quantitative impact on QPG PET as compared to SWB PET. When interpreting quantitative changes in lesions, it is critical to consider the influences of free-breathing CT-based attenuation correction.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Neoplasias Colorrectales/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Anciano , Algoritmos , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Movimiento , Estudios Prospectivos , Respiración