Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 239
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38705454

RESUMEN

OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.

2.
Ann Surg ; 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38647145

RESUMEN

OBJECTIVE: With an increasing life expectancy, more octogenarian patients are referred with complex aortic aneurysms (cAAA). The aim of this study was to evaluate short and mid-term outcomes following fenestrated aortic repair (FEVAR) in octogenarians. SUMMARY BACKGROUND DATA: Few studies looking at octogenarian-specific outcomes with diverging results. METHODS: Retrospective, multicentre cohort study including consecutive patients undergoing elective FEVAR for cAAAs or type IV thoracoabdominal aortic aneurysms between 2007-2022 in eight high-volume centres. Octogenarians vs. non-octogenarians were compared. The primary outcome was 30-day mortality. Secondary outcomes included 1, 2 and 5-year survival and reintervention rates. RESULTS: A total of 729 patients (median age of 74.8 years [IQR 69.2 - 79.14]) were included, 169 (23%) of which were octogenarians, with 316 (43.3%) patients undergoing juxta/pararenal aneurysm repair. Although octogenarians presented less complex but larger (61 mm vs. 58 mm) aneurysms, the number of fenestrations was similar across groups. No differences in in-hospital mortality (4.1 vs. 3.0%), MAE (16.6% vs 12.2%) or reintervention rates (11.2 vs. 10%) were found. Multivariable logistic regression of in-hospital mortality identified BMI (OR 0.66, 95% CI 0.51-0.95, P=0.003), chronic heart failure (OR 7.70, 95% CI 1.36-36.15, P=0.003) and GFR<45 ml/min/1.73 m2 (OR 5.25, 95% CI 1.20-22.86, P=0.027) as independent predictors. Median follow-up was 41 months. The 1, 2 and 5-year survival rates were 91.3%, 81.8% and 49.5% in octogenarians vs 90.6%, 86.5% and 68.8% in non-octogenarian patients (Log-rank: =0.001). Freedom from aortic-related death and freedom from reintervention at five-years were similar across groups (log-rank=0.94 and .76, respectively). Age>80 was not an independent predictor of 30-day or long-term mortality on multivariable and Cox regression analysis. CONCLUSIONS: Elective FEVAR in octogenarians appears to be safe, with similar outcomes as in younger patients. Future studies looking at improved patient selection methods to ensure long-term survival benefits in both octogenarians and younger patients are warranted.

3.
Am J Case Rep ; 25: e942746, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38566390

RESUMEN

BACKGROUND RARP is an established procedure in treatment of localized prostate cancer. Hemorrhagic complications in the postoperative period are rare, but sometimes life-threatening. Adequate monitoring and prompt intervention in these unusual scenarios rely on clinical judgement and blood and imaging studies. Prostatic fossa pseudoaneurysm formation after RARP is very rare and its etiology is not well known; it may be related to small vessel trauma. It becomes apparent with the development of hematuria 1-6 weeks after surgery. CASE REPORT A 58-year-old man underwent RARP with extended lymph node dissection for intermediate-risk prostate cancer, with bilateral preservation of neurovascular bundles and puboprostatic ligaments. He was discharged on day 2 without complications. In the following 4 weeks he came to the Emergency Department 3 times with hematuria and acute urinary retention. Four weeks after surgery, a pelvic CT angiogram showed a 20-mm pseudoaneurysm in the prostatic fossa, which was embolized by percutaneous angiography, with resolution of symptoms. He was discharged soon thereafter. CONCLUSIONS This case study describes a patient with prostatic fossa pseudoaneurysm after RARP. It was diagnosed 1 month after surgery and effectively managed by percutaneous embolization. Despite being a very rare condition, it must be kept in mind, especially when postoperative hematuria develops 1-6 weeks after surgery. Use of a management algorithm including serial blood tests, CT angiogram, and percutaneous angiography can lead to early detection and avoid life-threatening hemorrhage and overall postoperative morbidity.


Asunto(s)
Aneurisma Falso , Neoplasias de la Próstata , Robótica , Masculino , Humanos , Persona de Mediana Edad , Hematuria/etiología , Hematuria/cirugía , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Prostatectomía/efectos adversos , Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Resultado del Tratamiento
4.
Ann Surg ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38323417

RESUMEN

OBJECTIVE: To analyze the outcomes of urgent/emergent endovascular aortic repair of patients with free/contained ruptured thoracoabdominal aortic aneurysms (rTAAA). BACKGROUND: Endovascular repair of rTAAA has been scarcely described in emergent setting. METHODS: An international multicenter retrospective observational study (ClinicalTrials.govID:NCT05956873) from January-2015 to January-2023 in 6 European and 1 United States Vascular Surgery Centers. Primary end-points were technical success, 30-day and/or in-hospital mortality and follow-up survival. RESULTS: A total of 100 rTAAA patients were included (75 male; mean age 73 y). All patients (86 contained and 14 free ruptures) were symptomatic and treated within 24-hours from diagnosis: multi-branched off-the-shelf devices (Zenith t-branch,Cook Medical Inc.Bjaeverskov,Denmark) in 88 patients, physician-modified endografts in 8, patient-specific device or parallel grafts in two patients each. Primary technical success was achieved in 89 patients and 30-day and/or in-hospital mortality was 24%. Major adverse events (MAEs) occurred in 34% of patients (permanent dialysis and paraplegia in 4 and 8 patients, respectively). No statistical differences were detected in mortality rates between free and contained ruptured patients (43%vs.21%; P =0.075). Multivariate analysis revealed contained rupture favoring technical success (Odd-Ratio10.1;95%Confidence-Interval:3.0-33.6; P =<0.001). MAEs (OR9.4;95%C-I:2.8-30.5; P =<0.001) and pulmonary complications (OR11.3;95%CI:3.0-41.5; P =<0.001) were independent risk factors for 30-day and/or in-hospital mortality. Median follow-up time was 13 months (interquartile range 5-24); 1-year survival rate was 65%. Aneurysm diameter>80 mm (Hazard-Ratio:2.0;95%CI:1.0-30.5; P =0.037), technical failure (HR:2.6;95%CI:1.1-6.5; P =0.045) and pulmonary complications (HR:3.0;95%CI:1.2-7.9; P =0.021) were independent risk factors for follow-up mortality. CONCLUSION: Endovascular repair of rTAAA shows high technical success; the presence of free rupture alone appear not to correlate with early mortality. Effective prevention/management of post-operative complications is crucial for survival.

5.
Eur J Vasc Endovasc Surg ; 67(2): 192-331, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38307694

RESUMEN

OBJECTIVE: The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS: The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS: A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION: The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.

6.
Bioinformatics ; 40(2)2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38265243

RESUMEN

MOTIVATION: BISCAP is a state-of-the-art tool for automatically characterizing biofilm images obtained from Optical Coherence Tomography. Limited availability of other software tools is reported in the field. BISCAP's first version processes 2D images only. Processing 3D images is a problem of greater scientific relevance since it deals with the entire structure of biofilms instead of their 2D slices. RESULTS: Building on the image-processing principles and algorithms proposed earlier for 2D images, these were adapted to the 3D case, and a more general implementation of BISCAP was developed. The primary goal concerns the extension of the initial methodology to incorporate the depth axis in 3D images; multiple improvements were also made to boost computational performance. The calculation of structural properties and visual outputs was extended to offer new insights into the 3D structure of biofilms. BISCAP was tested using 3D images of biofilms with different morphologies, consistently delivering accurate characterizations of 3D structures in a few minutes using standard laptop machines. Low user dependency is required for image analysis. AVAILABILITY AND IMPLEMENTATION: BISCAP is available from https://github.com/diogonarciso/BISCAP. All images used in the tutorials and the validation examples are available from https://web.fe.up.pt/∼fgm/biscap3d.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Programas Informáticos , Algoritmos , Biopelículas
7.
Int J Esthet Dent ; 19(1): 14-33, 2024 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-38284941

RESUMEN

Despite the clear advances regarding the restoration of posterior teeth, especially with the minimally invasive approach, there are still several topics where the available scientific evidence does not provide clear answers in terms of clinical decisions. The indications, differences, and clinical protocols for partial adhesive restorations (onlays, overlays, and endocrowns) and resistance form restorations (full-contour resistive crowns) were presented in Parts I and II of the present article series based on Coverage of susceptible cusps, Adhesion advantages and limitations, Resistance forms to be implemented, Esthetic concerns, and Subgingival management - the CARES concept. Now, in Part III, the focus is on different approaches of managing subgingival areas, gaining "ferrule" design, and the role of posts on the restorability strategies of severely compromised teeth.


Asunto(s)
Atención Odontológica , Estética Dental , Humanos , Fenómenos Físicos , Adherencias Tisulares
9.
Amyloid ; 31(1): 32-41, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37493395

RESUMEN

BACKGROUND: Early diagnosis and prognostic stratification of cardiac transthyretin amyloidosis are crucial. Although 99mTc 3,3-diphosphono-1,2-propanedicarboxylic acid (DPD) scintigraphy is the preferred method for the non-invasive diagnosis, its accuracy appears to be limited in transthyretin amyloidosis protein (ATTR) V30M mutation. Furthermore, its prognostic value in this mutation is unknown. This study investigated the diagnostic value of DPD scintigraphy to detect ATTR cardiomyopathy in V30M mutation and explored its prognostic value regarding mortality. METHODS: A total of 288 ATTR V30M mutation carriers (median age: 46 years; 49% males) without myocardial thickening (defined as septal thickness ≥13mm) attributable to other causes and who underwent DPD scintigraphy were enrolled. ATTR cardiomyopathy was defined by septal thickness ≥13mm and at least one of the criteria: late heart-to-mediastinum (H/M) 123I-metaiodobenzylguanidine (MIBG) uptake ratio <1.60; electrical heart disease or biopsy-documented amyloidosis. RESULTS: ATTR cardiomyopathy was identified in 41 (14.2%) patients and cardiac DPD uptake in 34 (11.8%). During a mean follow-up of 33.6 ± 1.2 months, 16 patients died (5.6%). Mortality was 14 times higher in patients with ATTR cardiomyopathy, 13 times higher in those with DPD uptake and 10 times higher in those with late H/M MIBG <1.60. The combined assessment of septal thickness and cardiac DPD uptake improved risk stratification: patients without septal thickening and without DPD retention had an excellent prognosis while those who presented either or both of them had a significantly worse prognosis, with 5-year mortality rates ranging from 39.9 to 53.3%. CONCLUSIONS: DPD scintigraphy is useful for prognostic stratification of ATTR V30M mutation carriers. Patients without septal thickening and no DPD uptake present the best prognosis compared to those with any signs of cardiac involvement.


Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Masculino , Humanos , Persona de Mediana Edad , Femenino , Pronóstico , 3-Yodobencilguanidina , Prealbúmina/genética , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/genética , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/genética , Cintigrafía
10.
Rev. esp. enferm. dig ; 115(12): 737-738, Dic. 2023. ilus
Artículo en Inglés | IBECS | ID: ibc-228727

RESUMEN

A 63-year-old woman presented with dyspepsia de novo. An esophagogastroduodenoscopy revealed a 30 mm flat yellowish esophageal lesion, 28 cm from the incisors (Fig. 1a), with the stomach and duodenum without any lesion. Helicobacter pylori infection was excluded. Histological examination was suggestive of a lymphoproliferative process (Fig. 1b). Immunohistochemistry showed diffuse positivity for CD20 (Fig. 1c) and BCL-2 (Fig. 1d), dim CD10 and BCL-6 staining, a Ki-67 of 20-25%, no CD21 or cyclin D1 expression, all these features compatible with low-grade follicular lymphoma. Physical examination was unremarkable. Computed tomography of the neck, chest, and abdomen revealed no lymph node enlargement, hepatosplenomegaly or metastasis. Blood routine tests and tumor markers were at normal levels. Bone marrow biopsy showed no involvement by lymphoma. Therefore, a diagnosis of primary follicular lymphoma of the esophagus was made. The patient opted for a watch-and-wait strategy and there is no evidence of disease progression after four years of follow-up.(AU)


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Esófago/lesiones , Dispepsia/diagnóstico por imagen , Linfoma Folicular/diagnóstico por imagen , Linfoma no Hodgkin , Infecciones por Helicobacter , Pacientes Internos , Examen Físico , Dispepsia/tratamiento farmacológico , Endoscopía del Sistema Digestivo , Enfermedades Gastrointestinales
11.
J Endovasc Ther ; : 15266028231219435, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38140719

RESUMEN

OBJECTIVE: The aim of this study was to assess the risk of radiation-induced cancer development in patients that have undergone an infrarenal EVAR, stratifying the relative contributions of the procedure and the preoperative and postoperative CTAs. METHODS AND MATERIALS: The organ-specific absorbed radiation doses from CTA and the EVAR procedure were estimated from the radiation exposures of 95 and 45 male patients, respectively. Lifetime attributable risk (LAR) cancer predictions were calculated for 14 different organs. Life expectancy was assumed from a previous cohort of patients undergoing infra-renal EVAR. RESULTS: The calculated total excess cancer risk was 0.0046, ie, 1 out of 220 patients will develop a neoplasm after being exposed to the ionizing radiation from the preoperative CTA, the EVAR and annual CTA examinations for 15 years. The procedure and the preoperative CTA contributed with 38% of the total excess risk, while the rest was derived from the follow-up. If the entire CTA based follow-up would have been eliminated, an excess risk of 0.0018 (1/560) would remain. CONCLUSIONS: 1 out of 219 patients who have undergone EVAR of an infra-renal AAA have a lifetime risk of developing cancer secondary to the radiation exposures related to the procedure and the CTAs used preoperatively and during follow-up. This risk derives mostly from the yearly postoperative CTAs, underlining the potential benefits of reducing or replacing their use. CLINICAL IMPACT: A simulation-based estimation reinforced the potential deleterious effects of the radiation exposure for patients undergoing Endovascular Aneurysm Repair (EVAR) of Abdominal Aortic Aneurysms (AAA) and subsequently followed by yearly Computer Tomography Angiographies (CTAs). The risk could be as high as 1 out 219 patients developing a neoplasm after 15 years. The largest exposure derives from the follow-up CTAs and efforts to minimize their use as well as the intraoperative radiation are greatly needed. The simulation-based estimations done in this study reinforce potential deleterious effects of the radiation exposure for patients undergoing EVAR of AAA. Efforts should be done to minimize the intraoperative radiation and the number of CTAs used during follow-up.

12.
Artículo en Inglés | MEDLINE | ID: mdl-37966657

RESUMEN

BACKGROUND: Brugada syndrome (BrS) is associated with abnormal electrophysiological properties at right ventricular epicardium, consisting of fragmented electrograms extending well beyond QRS termination. We aimed to evaluate the utility of signal-averaged electrocardiogram (SA-ECG) for the noninvasive assessment of late potentials (LP) and risk stratification of BrS patients. METHODS: A prospective, observational, single-center study of BrS patients is submitted to SA-ECG with the determination of the total filtered QRS duration (fQRS), root mean square voltage of the 40 ms terminal portion of the QRS (RMS40), and duration of the low-amplitude electric potential component of the terminal portion of the QRS (LAS40). LP were considered positive when above standard cut-offs: fQRS > 114 ms, RMS40 < 20 µV, and LAS40 > 38 ms. The rates of malignant arrhythmic events (MAEs), defined as sudden death or appropriate shocks, were compared in relation to clinical characteristics and SA-ECG findings. RESULTS: A total of 106 BrS patients (mean age, 48 ± 12 years, 67.9% male) were studied, 49% with type-1 spontaneous pattern and 81% asymptomatic. During a median follow up of 4.7 years, 10 patients (7.1%) suffered MAEs, including 4 sudden deaths. The presence of LP was significantly associated with the arrhythmic risk, which increased with the number of altered LP criteria. In comparison to the patients who had none or 1 altered LP criterium, MAE risk was 4.7 times higher in those with 2 altered criteria and 9.4 times higher in those with 3 altered LP criteria. CONCLUSIONS: SA-ECG may be a useful tool for risk stratification in BrS. The presence of 2 or 3 abnormal LP criteria could identify a subset of asymptomatic patients at high risk of arrhythmic events.

14.
J Endovasc Ther ; : 15266028231208656, 2023 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-37902446

RESUMEN

PURPOSE: To illustrate the technique of antegrade in situ laser fenestration (ISLF) on a predesign custom-manufactured stent-graft with single reinforced fenestration for use in emergency endovascular repair of complex abdominal aortic aneurysms (AAAs). TECHNIQUE: A short custom-made device (CMD) fenestrated graft was predesigned with a single preloaded 8 mm strut-free fenestration at 12 o'clock position. A modified preloaded system was used to allow unilateral access from the distal port if necessary. After bilateral percutaneous femoral access, the graft was deployed under fusion guidance with the CMD fenestration matching the superior mesenteric artery (SMA) origin and immediately bridged as per standard technique. The aneurysm was then excluded with a bifurcated device. A large steerable sheath was used to allow for sequential antegrade laser in situ fenestration and stenting of the renal arteries. CONCLUSIONS: Single-vessel customized short fenestrated grafts for the SMA and antegrade in situ laser renal fenestrations are technically feasible for repair of acute complex AAAs even after previous infrarenal reconstruction. It could become an off-the-shelf solution to limit aortic coverage and reno-visceral ischemia, even in patients with a narrow aortic diameter at the renal level. CLINICAL IMPACT: Single-vessel precustomized short fenestrated grafts for the SMA combined with renal artery antegrade ISLF can be a feasible option for the acute repair of patients with complex aneurysms and a narrow aortic diameter at the reno-visceral segment. It may limit aortic coverage and reno-visceral ischemic time and also be applicable after previous infrarenal endovascular aneurysm repair (EVAR).

15.
J Endovasc Ther ; : 15266028231202456, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37750487

RESUMEN

PURPOSE: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. MATERIALS AND METHODS: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. RESULTS: A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011-1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176-0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). CONCLUSION: Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. CLINICAL IMPACT: Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.

16.
Ann Surg ; 278(4): 568-577, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37395613

RESUMEN

OBJECTIVE: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS: A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Estudios Retrospectivos , Prótesis Vascular
17.
PLoS One ; 18(7): e0288541, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37450424

RESUMEN

Physical literacy is a multidimensional construct that has been defined and interpreted in various ways, one of the most common being "the motivation, confidence, physical competence, knowledge and understanding to maintain physical activity throughout the life course". Although its improvement can positively affect many behavioral, psychological, social, and physical variables, debate remains over an appropriate method of collecting empirical physical literacy data. This systematic review sought to identify and critically evaluate all primary studies (published and unpublished, regardless of design or language) that assessed physical literacy in adults or have proposed measurement criteria. Relevant studies were identified by searching four databases (Pubmed, SportDiscus, APA PsycINFO, Web of Science), scanning reference lists of included articles, and manual cross-referencing of bibliographies cited in prior reviews. The final search was concluded on July 15, 2022. Thirty-one studies, published from 2016 to 2022, were analyzed. We found seven instruments measuring physical literacy in adults, of which six were questionnaires. The Perceived Physical Literacy Instrument was the first developed for adults and the most adopted. The included studies approached physical literacy definition in two ways: by pre-defining domains and assessing them discretely (through pre-validated or self-constructed instruments) and by defining domains as sub-scales after factorial analyses. We found a fair use of objective and subjective measures to assess different domains. The wide use of instruments developed for other purposes in combined assessments suggests the need for further instrument development and the potential oversimplification of the holistic concept, which may not result in a better understanding of physical literacy. Quality and usability characteristics of measurements were generally insufficiently reported. This lack of data makes it impossible to compare and make robust conclusions. We could not identify if any of the existing physical literacy assessments for adults is appropriate for large-scale/epidemiological studies.


Asunto(s)
Ejercicio Físico , Alfabetización en Salud , Alfabetización en Salud/métodos , Encuestas y Cuestionarios , Procesos Mentales
18.
J Endovasc Ther ; : 15266028231179593, 2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37300282

RESUMEN

OBJECTIVES: To analyze device designs, similarities and overlaps of custom-made fenestrated arch endografts intended for mid/distal arch thoracic endovascular aortic repair. MATERIALS AND METHODS: A multicenter cross-sectional study analyzing custom-made anonymized graft plans was performed. Graft plans were included from a cohort of mid/distal aortic arch repairs using custom-made fenestrated aortic endografts treated at 8 centers. Grafts targeting >2 arteries were excluded. No patient/clinical data were analyzed. A descriptive analysis was performed followed by an analysis of overlap of the designs to reach a common design in which the greatest number of grafts would overlap. RESULTS: One hundred thirty-one graft plans were included. All grafts were custom-made grafts from the COOK Medical Fenestrated arch platform. Ninety-four (71.8%) had a scallop-and-single-fenestration design, 33 (25.2%) had a single fenestration and 4 (4.3%) a single scallop. For analysis purposes, these latter 4 grafts were excluded. Two main graft plans (Plans 1 and 2) were proposed after analysis with similar configuration (1 scallop with 30 mm width, 20 mm height, 12:00 position; 1 preloaded fenestration with 8 mm diameter, 26 mm from the top of the graft and 12:00 position; tapered, with a 193 mm length and 32 mm distal diameter) but with 2 different proximal diameters of 38 mm (Plan 1) and 44 mm (Plan 2), reaching an overall feasibility of 85.8% (n=109), being 47.2% (n=60) and 38.6% (n=49) for each design, respectively. CONCLUSION: The degree of overlap between the studied fenestrated and/or scalloped thoracic endovascular aneurysm repair (TEVAR) graft designs was high. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility. CLINICAL IMPACT: In a multicenter study analyzing 127 fenestrated aortic arch endograft plans from 9 aortic centers, we found that the degree of overlap between the studied fenestrated and/or scalloped arch graft designs was high and that 2 proposed graft designs would be theoretically applicable in 85.8% of cases. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility.

19.
J Vasc Surg ; 78(4): 863-873.e3, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37330705

RESUMEN

OBJECTIVE: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. METHODS: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. RESULTS: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. CONCLUSIONS: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Femenino , Prótesis Vascular , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Estudios de Cohortes , Resultado del Tratamiento , Factores de Tiempo , Diseño de Prótesis
20.
J Vasc Surg ; 78(4): 854-862.e1, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37321524

RESUMEN

OBJECTIVE: This multicenter international study aimed to describe outcomes of fenestrated-branched endovascular aortic repairs (FB-EVAR) in a cohort of patients treated for chronic post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs). METHODS: We reviewed the clinical data of all consecutive patients treated by FB-EVAR for repair of extent I to III PD-TAAAs in 16 centers from the United States and Europe (2008-2021). Data were extracted from institutional prospectively maintained databases and electronic patient records. All patients received off-the-shelf or patient-specific manufactured fenestrated-branched stent grafts. Endpoints were any cause mortality and major adverse events at 30 days, technical success, target artery (TA) patency, freedom from TA instability, minor (endovascular with <12 Fr sheath) and major (open or ≥12 Fr sheath) secondary interventions, patient survival, and freedom from aortic-related mortality (ARM). RESULTS: A total of 246 patients (76% male; median age, 67 years [interquartile range, 61-73 years]) were treated for extent I (7%), extent II (55%), and extent III (35%) PD-TAAAs by FB-EVAR. The median aneurysm diameter was 65 mm (interquartile range, 59-73 mm). Eighteen patients (7%) were octogenarians, 212 (86%) were American Society of Anesthesiologists class ≥3, and 21 (9%) presented with contained ruptured or symptomatic aneurysms. There were 917 renal-mesenteric vessels targeted by 581 fenestrations (63%) and 336 directional branches (37%), with a mean of 3.7 vessels per patient. Technical success was 96%. Mortality and rate of major adverse events at 30 days was 3% and 28%, including disabling complications such as new onset dialysis in 1%, major stroke in 1%, and permanent paraplegia in 2%. Mean follow-up was 24 months. Kaplan-Meier (KM) estimated patient survival at 3 and 5 years was 79% ± 6% and 65% ± 10%. KM estimated freedom from ARM was 95% ± 3% and 93% ± 5% at the same intervals. Unplanned secondary interventions were needed in 94 patients (38%), including minor procedures in 64 (25%) and major procedures in 30 (12%). There was one conversion to open surgical repair (<1%). KM estimated freedom from any secondary intervention was 44% ± 9% at 5 years. KM estimated primary and secondary TA patency were 93% ± 2% and 96% ± 1% at 5 years, respectively. CONCLUSIONS: FB-EVAR for chronic PD-TAAAs was associated with high technical success and a low rate of mortality (3%) and disabling complications at 30 days. Although the procedure is effective in the prevention of ARM, patient survival was low at 5 years (65%), likely due to the significant comorbidities in this cohort of patients. Freedom from secondary interventions at 5 years was 44%, although most procedures were minor. The significant rate of reinterventions highlights the need for continued patient surveillance.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Procedimientos Endovasculares/efectos adversos , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Riesgo , Stents/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...