Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Can J Urol ; 31(2): 11861-11863, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38642466

RESUMEN

Standard treatment approaches for localized prostate cancer remain limited to active surveillance, radiotherapy, and radical prostatectomy. We present a case of transition zone prostate cancer that was treated with holmium laser enucleation of the prostate, a procedure that is normally reserved for the management of benign prostatic hyperplasia.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Hiperplasia Prostática , Neoplasias de la Próstata , Masculino , Humanos , Próstata , Láseres de Estado Sólido/uso terapéutico , Neoplasias de la Próstata/cirugía , Prostatectomía/métodos , Hiperplasia Prostática/cirugía , Resultado del Tratamiento
4.
Cureus ; 15(4): e38284, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37255885

RESUMEN

Traumatic cervical arteriovenous fistulas are rare, accounting for only 4% of all arteriovenous fistulas. They can be caused by penetrating, or rarely, blunt trauma, resulting in high-pressure arterial blood draining directly into a vein, decreasing distal perfusion. They are seldom reported as a complication of a carotid paraganglioma surgical resection. Historically, arteriovenous fistulas were treated initially conservatively, after that, surgically; nowadays, endovascular treatment, when feasible, is the preferred method as it offers advantages over surgery. This case report describes a rare traumatic cervical arteriovenous fistula that developed after a carotid paraganglioma resection and was successfully treated using coils and Onyx embolic agent via endovascular embolization. After successful embolization, the patient had a smooth recovery and remained stable. In conclusion, vascular injury seems to be the only constant in all acquired cervical arteriovenous fistulas independent of the trauma mechanism; and endovascular treatment, when feasible, is preferred over surgery as it offers superior advantages.

5.
J Neurointerv Surg ; 15(3): 248-254, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35292570

RESUMEN

BACKGROUND: The pipeline embolization device (PED; Medtronic) has presented as a safe and efficacious treatment for small- and medium-sized intracranial aneurysms. Independently adjudicated long-term results of the device in treating these lesions are still indeterminate. We present 3-year results, with additional application of a flow diverter specific occlusion scale. METHODS: PREMIER (prospective study on embolization of intracranial aneurysms with pipeline embolization device) is a prospective, single-arm trial. Inclusion criteria were patients with unruptured wide-necked intracranial aneurysms ≤12 mm. Primary effectiveness (complete aneurysm occlusion) and safety (major neurologic event) endpoints were independently monitored and adjudicated. RESULTS: As per the protocol, of 141 patients treated with a PED, 25 (17.7%) required angiographic follow-up after the first year due to incomplete aneurysm occlusion. According to the Core Radiology Laboratory review, three (12%) of these patients progressed to complete occlusion, with an overall rate of complete aneurysm occlusion at 3 years of 83.3% (115/138). Further angiographic evaluation using the modified Cekirge-Saatci classification demonstrated that complete occlusion, neck residual, or aneurysm size reduction occurred in 97.1%. The overall combined safety endpoint at 3 years was 2.8% (4/141), with only one non-debilitating major event occurring after the first year. There was one case of aneurysm recurrence but no cases of delayed rupture in this series. CONCLUSIONS: The PED device presents as a safe and effective modality in treating small- and medium-sized intracranial aneurysms. The application of a flow diverter specific occlusion classification attested the long-term durability with higher rate of successful aneurysm occlusion and no documented aneurysm rupture. TRIAL REGISTRATION: NCT02186561.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Angiografía Cerebral/métodos , Embolización Terapéutica/métodos , Estudios de Seguimiento , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/etiología , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
6.
J Neurosurg Spine ; 38(2): 233-241, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36152330

RESUMEN

OBJECTIVE: The aim of this paper was to identify and characterize all the segmental radiculomedullary arteries (RMAs) that supply the thoracic and lumbar spinal cord. METHODS: All RMAs from T4 to L5 were studied systematically in 25 cadaveric specimens. The RMA with the greatest diameter in each specimen was termed the artery of Adamkiewicz (AKA). Other supporting RMAs were also identified and characterized. RESULTS: A total of 27 AKAs were found in 25 specimens. Twenty-two AKAs (81%) originated from a left thoracic or a left lumbar radicular branch, and 5 (19%) arose from the right. Two specimens (8%) had two AKAs each: one specimen with two AKAs on the left side and the other specimen with one AKA on each side. Eight cadaveric specimens (32%) had 10 additional RMAs; among those, a single additional RMA was found in 6 specimens (75%), and 2 additional RMAs were found in each of the remaining 2 specimens (25%). Of those specimens with a single additional RMA, the supporting RMA was ipsilateral to the AKA in 5 specimens (83%) and contralateral in only 1 specimen (17%). The specimens containing 2 additional RMAs were all (100%) ipsilateral to their respective AKAs. CONCLUSIONS: The segmental RMAs supplying the thoracic and lumbar spinal cord can be unilateral, bilateral, or multiple. Multiple AKAs or additional RMAs supplying a single anterior spinal artery are common and should be considered when dealing with the spinal cord at the thoracolumbar level.


Asunto(s)
Médula Espinal , Arteria Vertebral , Humanos , Médula Espinal/cirugía , Médula Espinal/irrigación sanguínea , Región Lumbosacra , Cadáver
7.
Front Bioeng Biotechnol ; 11: 1271760, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38192638

RESUMEN

Introduction: Chronic Obstructive Pulmonary Disease (COPD) is a prevalent respiratory disease that presents a high rate of underdiagnosis during onset and early stages. Studies have shown that in mild COPD patients, remodeling of the small airways occurs concurrently with morphological changes in the proximal airways. Despite this evidence, the geometrical study of the airway tree from computed tomography (CT) lung images remains underexplored due to poor representations and limited tools to characterize the airway structure. Methods: We perform a comprehensive morphometric study of the proximal airways based on geometrical measures associated with the different airway generations. To this end, we leverage the geometric flexibility of the Snakes IsoGeometric Analysis method to accurately represent and characterize the airway luminal surface and volume informed by CT images of the respiratory tree. Based on this framework, we study the airway geometry of smoking pre-COPD and mild COPD individuals. Results: Our results show a significant difference between groups in airway volume, length, luminal eccentricity, minimum radius, and surface-area-to-volume ratio in the most distal airways. Discussion: Our findings suggest a higher degree of airway narrowing and collapse in COPD patients when compared to pre-COPD patients. We envision that our work has the potential to deliver a comprehensive tool for assessing morphological changes in airway geometry that take place in the early stages of COPD.

8.
J Endovasc Ther ; : 15266028221118510, 2022 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-35983655

RESUMEN

PURPOSE: The aim of this study is to evaluate the value of selective intra-arterial cone-beam computed tomography angiography (CBCTA) relative to conventional computed tomography angiography (CTA) in understanding visceral artery aneurysm (VAA) morphology, and its impact on treatment planning. MATERIALS AND METHODS: Between January 2017 and August 2021, all patients who had a diagnosis of VAA and underwent intraoperative CBCTA imaging were retrospectively reviewed. Impact on treatment decisions, optimal C-arm angulations derived from CBCTA, and additional radiation exposure were reported. Two blinded independent reviewers qualitatively reviewed CBCTA and conventional CTA images. A 5-point Likert scale (1=poor image quality, 5=excellent image quality) was used to assess the overall image quality of each modality. Number of vessels arising from the aneurysm sac was counted. RESULTS: A total of 16 patients had a diagnosis of VAA during the study period, of whom 10 patients had intraoperative CBCTA and conventional CTA available for review. Out of 10 patients, 7 underwent successful endovascular treatment, 2 were deemed not amenable for endovascular embolization based on intraoperative CBCTA findings, and 1 had resolved pseudoaneurysm. Total fluoroscopy time and radiation dose (dose area product [DAP] and skin dose) for all procedures were 27.7 ± 19.9 minutes, 28 362 (±18 651) µGy*m2, and 1879 (±1734) mGy, respectively. Radiation exposure from CBCTA (DAP and skin dose) was 5703 (±3967) µGy*m2 and 223.6 (±141.3) mGy, respectively. In patients who underwent endovascular treatment, the proportional DAP from CBCTA was 18.3% (±15.3%) of the total procedural radiation dose. Qualitative rating of overall image quality of CBCTA images was superior to CTA images (mean score: 4.55 vs 3, p<0.001). More branch vessels arising from the VAA were identified by all reviewers in CBCTA as compared with conventional CTA (median, min-max: 3, 0-4 vs 2,1-3 vessels). CONCLUSION: Intraoperative CBCTA after selective intra-arterial contrast injection, with better spatial resolution, provided better delineation of visceral aneurysm morphology as compared with conventional, intravenous CTA and enabled optimal treatment planning at a reasonable additional radiation exposure. CLINICAL IMPACT: Visceral artery aneurysms (VAA) are often diagnosed incidentally by conventional computed tomographic angiography (CTA). Endovascular treatment typically requires selective angiographies at multiple projections to better understand aneurysm morphology, location, and efferent branch vessels. Intra-arterial cone-beam CT angiography (CBCTA) for VAA has the advantage of selective contrast opacification, better spatial resolution, and three-dimensional/multi-planar visualization of aneurysm morphology. In addition, CBCTA enables identification of optimal C-arm working projection for subsequent endovascular treatment. The aim of this study is to evaluate the value of intraoperative CBCTA relative to conventional CTA in understanding visceral artery aneurysm morphology and its impact on treatment planning.

9.
J Vasc Surg Cases Innov Tech ; 8(2): 265-270, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35586675

RESUMEN

Pancreaticoduodenal arterial arcade aneurysms are rare but are prone to rupture. We report the case of a 60-year-old woman with an asymptomatic pancreaticoduodenal artery aneurysm and concomitant celiac trunk occlusion that was treated using an endovascular approach. After percutaneous transfemoral access and superior mesenteric artery cannulation, intraoperative cone-beam computed tomography angiography was performed to better understand the aneurysm morphology and provide image guidance. On selecting the optimal working projection, the aneurysm and distal parent vessel were cannulated and treated by braided stent (low-profile visualized intraluminal support; MicroVention)-assisted coil embolization. Completion angiography and cone-beam computed tomography confirmed successful exclusion of the aneurysm sac and a patent pancreaticoduodenal arcade with a well-apposed stent.

10.
Materials (Basel) ; 15(6)2022 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-35329725

RESUMEN

High entropy alloys (HEAs) are the outstanding innovations in materials science and engineering in the early 21st century. HEAs consist of multiple elements with equiatomic or near equiatomic compositions, which exhibit superior mechanical properties, such as wear resistance, fatigue resistance, and corrosion resistance. HEAs are primarily used in structural and functional applications; hence, appropriate welding processes are essential to enhancing the performances and service lives of HEA components. Herein, a comprehensive overview of current state-of-art-of welding techniques for HEAs is elucidated. More specifically, the article discusses the fusion-based welding techniques, such as gas tungsten arc welding (GTAW) and laser beam welding (LBW), and solid-state welding techniques, such as friction stir welding (FSW) and explosive welding (EB), for a broad category of HEAs. In addition, the microstructural features and mechanical properties of HEAs welded using different techniques were explained for a broad spectrum of HEAs. Finally, this review discusses potential challenges in the welding of HEAs.

11.
J Ultrasound ; 25(2): 297-300, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32621120

RESUMEN

Positional occlusion of the internal carotid artery is an unusual phenomenon. Reports are scarce in the literature and generally related to compression by external agents when the head is rotated. Cases with no extrinsic etiology are even more uncommon and require high suspicion to avoid misdiagnosis. We present a case of a patient with intermittent internal carotid occlusion depending on the position of the head with no external agent identified. Due to the dynamic characteristics of this presentation, diagnostic tests yielded contradictory results. Carotid ultrasound during neck rotation revealed the positional occlusion. Ultrasound is a versatile technique to explore the carotid arteries in different angles of the neck, useful if positional pathology is suspected.


Asunto(s)
Arteria Carótida Interna , Cuello , Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Humanos , Cuello/diagnóstico por imagen , Rotación , Ultrasonografía
12.
J Neurointerv Surg ; 14(6): 577-584, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34282038

RESUMEN

OBJECTIVE: To evaluate the safety and effectiveness of the Flow Redirection Endoluminal Device (FRED) flow diverter in support of an application for Food and Drug Administration approval in the USA. METHODS: 145 patients were enrolled in a prospective, single-arm multicenter trial. Patients with aneurysms of unfavorable morphology for traditional endovascular therapies (large, wide-necked, fusiform, etc) were included. The trial was designed to demonstrate non-inferiority in both safety and effectiveness, comparing trial results with performance goals (PGs) established from peer-reviewed published literature. The primary safety endpoint was death or major stroke (National Institutes of Health Stroke Scale score ≥4 points) within 30 days of the procedure, or any major ipsilateral stroke or neurological death within the first year. The primary effectiveness endpoint was complete occlusion of the target aneurysm with ≤50% stenosis of the parent artery at 12 months after treatment, and in which an alternative treatment of the target intracranial aneurysm had not been performed. RESULTS: 145 patients underwent attempted placement of a FRED device, and one or more devices were placed in all 145 patients. 135/145 (93%) had a single device placed. Core laboratory adjudication deemed 106 (73.1%) of the aneurysms large or giant. A safety endpoint was experienced by 9/145 (6.2%) patients, successfully achieving the safety PG of <15%. The effectiveness PG of >46% aneurysm occlusion was also achieved, with the effectiveness endpoint being met in 80/139 (57.6%) CONCLUSION: As compared with historically derived performance benchmarks, the FRED flow diverter is both safe and effective for the treatment of appropriately selected intracranial aneurysms. CLINICAL REGISTRATION NUMBER: NCT01801007.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Accidente Cerebrovascular , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Estudios Prospectivos , Stents , Accidente Cerebrovascular/terapia , Resultado del Tratamiento
13.
Curr Neurovasc Res ; 18(3): 279-286, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34515001

RESUMEN

INTRODUCTION: The Low-Profile Visualized Intraluminal Support (LVIS) devices are a new generation of self-expandable, high-porosity stents approved for the treatment of large to giant wide-necked intracranial aneurysms via stent-assisted coiling. Here we report the radiographic and clinical outcomes seen with LVIS, LVIS Jr. and LVIS Blue from a single institution over a fiveyear period. METHODS: Patients with intracranial aneurysms treated by LVIS, LVIS Jr. and LVIS Blue technology over a five-year period (2012 - 2017) at our institution were retrospectively reviewed. RESULTS: Seventy-four patients (55 females and 19 males; average age = 59.2) with 74 aneurysms underwent embolization of intracranial aneurysms using LVIS (N = 10), LVIS Jr. (N = 47) or LVIS Blue (N = 12) devices at our institution over the study period. The most common location of treated aneurysms was the anterior communicating artery (31%), followed by the basilar artery (19%), and the middle cerebral artery (13%). The mean neck and dome sizes were 3.9±1.5mm and 6.6±3.2mm, respectively. The median follow-up time was 6 months. At the last radiographic follow- up, 93.1% of patients had complete occlusion (RR-I or OKM-D). In 5 cases (7%), the LVIS stent failed to open, requiring balloon angioplasty (N = 3) or stent recapture and use of a non-LVIS branded device (N = 2). Five patients had post-embolization infarcts, and 1 patient had an intra-operative dome rupture. CONCLUSION: LVIS brand of stents is a safe, effective, and technically feasible treatment strategy for wide-neck intracranial aneurysms, with high deployment success and aneurysm obliteration rates.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Intracraneal , Angiografía Cerebral , Estudios de Factibilidad , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
14.
J Neurointerv Surg ; 13(10): 935-941, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33526480

RESUMEN

BACKGROUND: Catheter retention and difficulty in retrieval have been observed during embolization of brain arteriovenous malformations (bAVMs) with the Onyx liquid embolic system (Onyx). The Apollo Onyx delivery microcatheter (Apollo) is a single lumen catheter designed for controlled delivery of Onyx into the neurovasculature, with a detachable distal tip to aid catheter retrieval. This study evaluates the safety of the Apollo for delivery of Onyx during embolization of bAVMs. METHODS: This was a prospective, non-randomized, single-arm, multicenter, post-market study of patients with a bAVM who underwent Onyx embolization with the Apollo between May 2015 and February 2018. The primary endpoint was any catheter-related adverse event (AE) at 30 days, such as unintentional tip detachment or malfunction with clinical sequelae, or retained catheter. Procedure-related AEs (untoward medical occurrence, disease, injury, or clinical signs) and serious AEs (life threatening illness or injury, permanent physiological impairment, hospitalization, or requiring intervention) were also recorded. RESULTS: A total of 112 patients were enrolled (mean age 44.1±17.6 years, 56.3% men), and 201 Apollo devices were used in 142 embolization procedures. The mean Spetzler-Martin grade was 2.38. The primary endpoint was not observed (0/112, 0%). The catheter tip detached during 83 (58.5%) procedures, of which 2 (2.4%) were unintentional and did not result in clinical sequelae. At 30 days, procedure related AEs occurred in 26 (23.2%) patients, and procedure-related serious AEs in 12 (10.7%). At 12 months, there were 3 (2.7%) mortalities, including 2 (1.8%) neurological deaths, none of which were device-related. CONCLUSION: This study demonstrates the safety of Apollo for Onyx embolization of bAVMs. CLINICAL TRIAL REGISTRATION: CNCT02378883.


Asunto(s)
Embolización Terapéutica , Malformaciones Arteriovenosas Intracraneales , Adulto , Encéfalo , Dimetilsulfóxido/efectos adversos , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Malformaciones Arteriovenosas Intracraneales/terapia , Masculino , Persona de Mediana Edad , Polivinilos/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento
15.
Curr Neurovasc Res ; 17(5): 754-759, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33243122

RESUMEN

BACKGROUND: Since the introduction of endovascular methods to treat cerebral aneurysms, several technical advances have allowed a greater number of aneurysms to be treated endovascularly as opposed to open surgical clipping. These include flow diverting stents, which do not utilize coils and instead treat aneurysms by acting as an "internal bypass." We sought to investigate whether flow diversion is replacing coiling at our institution. METHODS: A retrospective chart review on five years of data was conducted to investigate the possible increasing use of flow diversion devices compared to traditional simple or stent-assisted coiling. RESULTS: Over five years, the population revealed a trend toward an increased proportion of female patients, increased frequency of basilar tip and internal carotid artery (ICA) aneurysm location, increased hospital volume, and increased volume of patients treated by dual-trained neurosurgeons over interventional radiologists. Patients were stratified by aneurysm location and statistically significant differences were observed. Flow diversion devices were used with increasing frequency when treating aneurysms arising from the proximal internal carotid artery (Odds ratio (OR)=1.24, 95% CI: 1.02-1.50; p = 0.03), and middle cerebral artery (OR=2.60, 95% CI: 1.38-4.88; p = 0.003). Distal internal carotid artery aneurysm location came close to achieving statistical significance (OR=1.3, 95% CI: 0.99-1.72; p = 0.063). CONCLUSION: In our single center experience at Houston Methodist Hospital, flow diversion devices are being used more frequently for aneurysms arising from the proximal ICA, MCA, and likely distal ICA (though this third location barely failed to achieve statistical significance.


Asunto(s)
Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/terapia , Stents , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores Sexuales , Resultado del Tratamiento
16.
Appl Physiol Nutr Metab ; 45(11): 1232-1237, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32413271

RESUMEN

We aimed to compare the cardiorespiratory, metabolic, and perceptual responses to high- and moderate-intensity eccentric cycling versus moderate-intensity concentric cycling in chronic obstructive pulmonary disease (COPD) patients. Ten patients with moderate COPD (forced expiratory volume in 1 s (FEV1) = 68.6% ± 20.4% of predicted; 68.3 ± 9.1 years) performed 30 min of moderate-intensity concentric (CONC-M: 50% maximum workload; Wmax), moderate-intensity eccentric (ECC-M: 50% Wmax), and high-intensity eccentric (ECC-H: 100% Wmax) cycling. Average power output, oxygen consumption (V̇O2), minute ventilation (VE), respiratory frequency (fR), oxygen saturation (SpO2), heart rate (HR), systolic and diastolic blood pressure (SBP and DBP), rate of perceived exertion (RPE), and dyspnea were measured during cycling. Compared with CONC-M, lower V̇O2 (-52% ± 14%), VE (-47% ± 16%), fR (-21% ± 14%), HR (-14% ± 16%), SBP (-73% ± 54%), RPE (-36% ± 26%), and dyspnea (-41% ± 37%) were found during ECC-M. During ECC-H, a similar metabolic demand to CONC-M was found. However, average power output was 117% ± 79% higher during ECC-H. Eccentric cycling can be safely performed by COPD patients and induced lower cardiorespiratory, metabolic, and perceptual responses than concentric exercise when performed at the same workload. Novelty Moderate- and high-intensity eccentric cycling can be performed by COPD patients. Moderate-intensity eccentric cycling showed lower cardiorespiratory, metabolic, and perceptual demand than concentric cycling at the same workload in COPD patients. Even at double workload, eccentric cycling induces lower cardiorespiratory, metabolic, and perceptual demand than moderate-intensity concentric cycling.


Asunto(s)
Ejercicio Físico , Esfuerzo Físico , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Anciano , Presión Sanguínea , Frecuencia Cardíaca , Humanos , Persona de Mediana Edad , Consumo de Oxígeno
17.
Oper Neurosurg (Hagerstown) ; 19(2): E203-E208, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32123901

RESUMEN

BACKGROUND AND IMPORTANCE: Superior cerebellar artery (SCA) perforator aneurysms are extremely rare, with only one other case published in the literature. There is no conclusive management strategy for these aneurysms, although endovascular treatment, open surgical treatment with clipping, and antifibrinolytic administration with spontaneous thrombosis have all been discussed. CLINICAL PRESENTATION: A 61-yr-old male presented with intraventricular hemorrhage (IVH) primarily in the posterior fossa. He was found to have a dissecting left SCA perforator aneurysm lying on the floor of the fourth ventricle. The aneurysm was not amenable to endovascular treatment, and antifibrinolytic therapy failed to spontaneously thrombose the aneurysm. We performed a suboccipital craniotomy and used a supracerebellar transvermian approach to resect the aneurysm. There was total obliteration of the aneurysm on postoperative cerebral angiogram. CONCLUSION: SCA perforator aneurysms represent an extremely uncommon subset of intracranial aneurysms. The best therapeutic strategy has yet to be definitively proven. When pursuing surgical treatment, the supracerebellar transvermian navigated approach can be a useful and safe option, as described and illustrated in this video.


Asunto(s)
Disección Aórtica , Aneurisma Intracraneal , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Arterias , Angiografía Cerebral , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
18.
J Neurointerv Surg ; 12(1): 62-66, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31308197

RESUMEN

BACKGROUND: Preliminary clinical studies on the safety and efficacy of the pipeline embolization device (PED) for the treatment of small/medium aneurysms have demonstrated high occlusion rates with low complications. OBJECTIVE: To evaluate the safety and effectiveness of the PED for treatment of wide necked small and medium intracranial aneurysms. METHODS: PREMIER is a prospective, multicenter, single arm trial. Patients were treated with the PED for unruptured wide necked aneurysms, measuring ≤12 mm along the internal carotid artery or vertebral artery, between July 2014 and November 2015. At 1 year post-procedure, the primary effectiveness endpoint was complete occlusion (Raymond grade 1) without major parent vessel stenosis (≤50%) or retreatment, and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurologic death. RESULTS: A total of 141 patients were treated with PEDs (mean age 54.6±11.3 years, 87.9% (124/141) women). Mean aneurysm size was 5.0±1.92 mm, and 84.4% (119/141) measured <7 mm. PED placement was successful in 99.3% (140/141) of patients. Mean number of PEDs implanted per patient was 1.1±0.26; a single PED was used in 92.9% (131/141) of patients. At 1 year, 97.9% (138/141) of patients underwent follow-up angiography with 76.8% (106/138) of patients having met the study's primary effectiveness endpoint. The combined major morbidity and mortality rate was 2.1% (3/140). CONCLUSIONS: Treatment of wide necked small/medium aneurysms with the PED results in high rates of complete occlusion without significant parent vessel stenosis and low rates of permanent neurologic complications. TRIAL REGISTRATION: NCT02186561.


Asunto(s)
Prótesis Vascular/tendencias , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents Metálicos Autoexpandibles/tendencias , Adulto , Anciano , Embolización Terapéutica/instrumentación , Embolización Terapéutica/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Retratamiento/tendencias , Resultado del Tratamiento
19.
Lab Med ; 51(3): 310-314, 2020 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-31665395

RESUMEN

A 70-year-old female with a history of hypertension and left A2 segment aneurysm was scheduled for pipeline embolization device (PED) placement. Preinterventional antiplatelet prophylaxis included aspirin and ticagrelor. Unexpectedly, after 13 days of treatment, VerifyNow showed a P2Y12 reaction unit (PRU) value of 216, approximately >5 times the mean PRU of other patients on aspirin and ticagrelor. We confirmed platelet reactivity and ticagrelor resistance with light transmission aggregometry. Antiplatelet therapy was switched to prasugrel, and aspirin was continued. Eight days later, the P2Y12 reaction value (PRU) was 164. PED was placed without complications. Unlike clopidogrel, ticagrelor is a direct P2Y12 inhibitor that does not require metabolism to an active metabolite. Ticagrelor resistance is very rarely reported. To the best of our knowledge, there has been no case of ticagrelor resistance reported in the context of pre-PED placement prophylaxis.


Asunto(s)
Plaquetas/fisiología , Embolización Terapéutica , Pruebas de Función Plaquetaria/métodos , Clorhidrato de Prasugrel/uso terapéutico , Ticagrelor/uso terapéutico , Anciano , Equipos y Suministros , Femenino , Humanos , Agregación Plaquetaria , Ejercicio Preoperatorio , Estudios Prospectivos , Receptores Purinérgicos P2Y12/metabolismo , Resultado del Tratamiento
20.
Rev. chil. med. intensiv ; 35(3)2020. ilus
Artículo en Español | LILACS | ID: biblio-1292491

RESUMEN

Posterior a una extubación programada existe un porcentaje de pacientes que fracasa y requiere reintubación (~20%), este evento es conocido como fracaso de extubación, el cual se asocia con mayor morbimortalidad. Para prevenir el fracaso de extubación se han propuesto terapias como la ventilación no invasiva (VNI) y la cánula nasal de alto flujo (CNAF). Estas terapias son capaces de entregar soporte respiratorio postextubación y justifican su uso en los efectos fisiológicos que son capaces de inducir, en dónde el impacto sobre el esfuerzo respiratorio e intercambio de gases sería fundamental. Con esta racionalidad fisiológica se han desarrollado diversos estudios en diferentes contextos clínicos, esto con el fin de dilucidar cuál terapia es la mejor alternativa. En esta revisión narrativa pretendemos describir y analizar los diversos efectos fisiológicos que induce la VNI y la CNAF


Asunto(s)
Humanos , Terapia por Inhalación de Oxígeno , Insuficiencia Respiratoria/terapia , Extubación Traqueal/métodos , Ventilación no Invasiva/métodos , Insuficiencia Respiratoria/fisiopatología , Desconexión del Ventilador , Trabajo Respiratorio/fisiología , Capacidad Residual Funcional/fisiología , Retratamiento , Cánula , Unidades de Cuidados Intensivos , Intubación Intratraqueal/métodos , Mediciones del Volumen Pulmonar/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...