RESUMEN
OBJECTIVE: To compare the transparent 3D computed tomography (CT) image protocol against conventional 3D-CT image-rendering protocol to assess femoral tunnel position in anatomic anterior cruciate ligament (ACL) reconstructions . METHODS: Eight knee CT scans from cadavers were analyzed by image rendering 3D-CT protocol, using Rhinoceros(r) software. The central point of the ACL tunnel was set using the sagittal plane. Same CT scans were analyzed using transparent 3D-CT measurement protocol with OsiriX(r) software. Central point of the ACL tunnel was set using sagittal, coronal and axial planes. The grid system described by Bernard and Hertel was used to compare tunnel positions between protocols, using height and length parameters . RESULTS: There was a significant difference between measurements using image rendering 3D-CT and transparent 3D-CT protocol for height (23.8 ± 7.9mm and 33.0 ± 5.0mm, respectively; p=0.017) and no differences for length (18.6 ± 4.2mm and 18.3 ± 4.5mm, respectively; p=0.560) . CONCLUSION: Height in transparent CT protocol was different and length was the same as compared to 3D-CT rendering protocol in Bernard and Hertel method for tunnel measurements. Level of Evidence II, Descriptive Laboratory Study.
OBJETIVO: Comparar o protocolo de tomografia computadorizada (TC) 3D por transparência com o protocolo TC-3D por renderização de imagem na avaliação do posicionamento de túneis femorais na reconstrução anatômica do ligamento cruzado anterior (LCA) . MÉTODO: Oito TC de joelho de cadáveres foram analisadas pelo protocolo de renderização de imagem 3D-TC utilizando o software Rhinoceros(r). O ponto central do túnel do LCA foi definido pelo plano sagital. As mesmas tomografias foram analisadas pelo protocolo 3D-TC por transparência, com o software OsiriX(r). O ponto central do túnel do LCA foi definido pelos planos sagital, coronal e axial. O sistema de grade de Bernard e Hertel foi utilizado para comparar a posição dos túneis entre os protocolos, utilizando parâmetros para comprimento e altura.. RESULTADOS: Houve diferença significativa entre as medidas dos protocolos de renderização de imagem 3D-TC e 3D-TC por transparência para altura (23,8 ± 7,9mm e 33,0 ± 5,0mm, respectivamente; p=0,017), sem diferenças para comprimento (18,6 ± 4,2mm e 18,3 ± 4,5mm, respectivamente; p=0,560) . CONCLUSÃO: A altura no protocolo de TC por transparência foi diferente e o comprimento foi igual quando comparados com o protocolo 3D-TC por renderização de imagem no método de Bernard e Hertel para mensuração dos túneis. Nível de Evidência II, Estudo Laboratorial Descritivo.
RESUMEN
ABSTRACT Objective: To compare the transparent 3D computed tomography (CT) image protocol against conventional 3D-CT image-rendering protocol to assess femoral tunnel position in anatomic anterior cruciate ligament (ACL) reconstructions . Methods: Eight knee CT scans from cadavers were analyzed by image rendering 3D-CT protocol, using Rhinoceros(r) software. The central point of the ACL tunnel was set using the sagittal plane. Same CT scans were analyzed using transparent 3D-CT measurement protocol with OsiriX(r) software. Central point of the ACL tunnel was set using sagittal, coronal and axial planes. The grid system described by Bernard and Hertel was used to compare tunnel positions between protocols, using height and length parameters . Results: There was a significant difference between measurements using image rendering 3D-CT and transparent 3D-CT protocol for height (23.8 ± 7.9mm and 33.0 ± 5.0mm, respectively; p=0.017) and no differences for length (18.6 ± 4.2mm and 18.3 ± 4.5mm, respectively; p=0.560) . Conclusion: Height in transparent CT protocol was different and length was the same as compared to 3D-CT rendering protocol in Bernard and Hertel method for tunnel measurements. Level of Evidence II, Descriptive Laboratory Study.
RESUMO Objetivo Comparar o protocolo de tomografia computadorizada (TC) 3D por transparência com o protocolo TC-3D por renderização de imagem na avaliação do posicionamento de túneis femorais na reconstrução anatômica do ligamento cruzado anterior (LCA) . Método: Oito TC de joelho de cadáveres foram analisadas pelo protocolo de renderização de imagem 3D-TC utilizando o software Rhinoceros(r). O ponto central do túnel do LCA foi definido pelo plano sagital. As mesmas tomografias foram analisadas pelo protocolo 3D-TC por transparência, com o software OsiriX(r). O ponto central do túnel do LCA foi definido pelos planos sagital, coronal e axial. O sistema de grade de Bernard e Hertel foi utilizado para comparar a posição dos túneis entre os protocolos, utilizando parâmetros para comprimento e altura. Resultados: Houve diferença significativa entre as medidas dos protocolos de renderização de imagem 3D-TC e 3D-TC por transparência para altura (23,8 ± 7,9mm e 33,0 ± 5,0mm, respectivamente; p=0,017), sem diferenças para comprimento (18,6 ± 4,2mm e 18,3 ± 4,5mm, respectivamente; p=0,560) . Conclusão: A altura no protocolo de TC por transparência foi diferente e o comprimento foi igual quando comparados com o protocolo 3D-TC por renderização de imagem no método de Bernard e Hertel para mensuração dos túneis. Nível de Evidência II, Estudo Laboratorial Descritivo.