Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 564, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39033113

RESUMEN

OBJECTIVE: The objective of this study was to investigate the initial stability of different screw placements in arthroscopic anterior cruciate ligament (ACL) tibial avulsion fracture fixation. METHODS: A three-dimensional knee model at 90° flexion was utilized to simulate type III ACL tibial avulsion fracture and arthroscopic screw fixation through different portals, namely the central transpatellar tendon portal (CTP), anterolateral portal (ALP), anteromedial portal (AMP), lateral parapatellar portal (LPP), medial parapatellar portal (MPP), lateral suprapatellar portal (LSP), medial suprapatellar portal (MSP). A shear force of 450 N was applied to the finite element models at 30° flexion to simulate the failure condition. The displacement of the bony fragment and the volume of the bone above 25,000 µ-strain (damaged bone volume) were calculated around the screw path. RESULTS: When the screw was implanted through CTP, the displacement of the bony fragment reached the maximum displacement which was 1.10 mm and the maximum damaged bone volume around the screw path was 148.70 mm3. On the other hand, the minimum displacement of the bony fragment was 0.45 mm when the screw was implanted through LSP and MSP. The minimum damaged bone volume was 14.54 mm3 around the screw path when the screw was implanted through MSP. CONCLUSION: Screws implanted through a higher medial portal generated less displacement of the bony fragment and a minimum detrimental strain around the screw path. The findings are clinically relevant as they provide biomechanical evidence on optimizing screw placement in arthroscopic ACL tibial avulsion fracture fixation.


Asunto(s)
Artroscopía , Tornillos Óseos , Análisis de Elementos Finitos , Fijación Interna de Fracturas , Fracturas por Avulsión , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/fisiopatología , Artroscopía/métodos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fracturas por Avulsión/cirugía , Fracturas por Avulsión/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Fenómenos Biomecánicos , Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA