RESUMEN
AIM: The Crown PRT (The Phospholipid Reduction Treatment) is a new stent bovine bioprosthesis for aortic valve replacement (AVR). Aim of this paper is to report the postoperative clinical and hemodynamic results after ninety consecutive implants. METHODS: After receiving CE mark in July 2014, two European university centers implanted the new Crown PRT (Sorin Group, Burnaby, Canada) for the first time. Up to now, ninety patients underwent aortic valve replacement, in isolated or combined procedures, for aortic stenosis or insufficiency. Intraoperative transesophageal echocardiogram was used to assess the prosthesis's function. In hospital outcomes and echocardiographic parameters were recorded. RESULTS: Age and Log Euroscore were 71.8±7.9 years and 10.2%±4.5 respectively. In-hospital mortality for isolated AVR was 0%; one patient died after a multiple procedure (overall 30-days mortality 1.1%). No adverse device effects were recorded. Intensive Care Unit stay was 2±5.8 days. At discharge, echocardiogram showed no paravalvular leaks and normal postoperative gradients. CONCLUSION: Our starting results showed that the Crown PRT is safe and reliable, with excellent hemodynamic performance. Further clinical results with a larger population and long term follow-up are needed to assess the versatility and the durability of this new device.
Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Austria , Ecocardiografía Transesofágica , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Factores de Tiempo , Resultado del TratamientoAsunto(s)
Tronco Braquiocefálico , Cateterismo Venoso Central , Remoción de Dispositivos , Falla de Equipo , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/etiología , Hemotórax/diagnóstico por imagen , Hemotórax/etiología , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Mediastino , Pleura , Traumatismos Torácicos/diagnóstico por imagen , Traumatismos Torácicos/terapia , Tomografía Computarizada por Rayos X , Adulto , Tronco Braquiocefálico/diagnóstico por imagen , Clavícula/lesiones , Medios de Contraste , Extravasación de Materiales Terapéuticos y Diagnósticos/diagnóstico por imagen , Extravasación de Materiales Terapéuticos y Diagnósticos/etiología , Femenino , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/terapia , Humanos , Mediastino/diagnóstico por imagen , Pleura/diagnóstico por imagen , Fracturas de las Costillas/diagnóstico por imagen , Fracturas de las Costillas/terapiaRESUMEN
Dengue virus (DENV) is an arthropod-borne virus (family Flaviviridae) causing dengue fever or dengue hemorrhagic fever. Here, we report the first fatal DENV infection imported into Germany. A female traveler was hospitalized with fever and abdominal pain after returning from Ecuador. Due to a suspected acute acalculous cholecystitis, cholecystectomy was performed. After cholecystectomy, severe spontaneous bleeding from the abdominal wound occurred and the patient died. Postmortem analysis of transudate and tissue demonstrated a DENV secondary infection of the patient and a gallbladder wall thickening (GBWT) due to an extensive edema.