Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Cardiovasc Med ; 11: 1449038, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39234609

RESUMEN

Background: Despite the high success rate of radiofrequency catheter ablation (RFCA) in Wolff-Parkinson-White Syndrome (WPW), localizing the successful ablation site can be challenging and may require multiple radiofrequency (RF) applications. Objective: This study aims to evaluate the efficacy of a novel workflow for the automatic and precise identification of accessory pathway ablation site, named Delta Wave Automatic Mapping. Methods: Patients undergoing a first procedure for RF ablation of a manifest accessory pathway were included. Electro-Anatomical Mapping (EAM) was performed with the CARTO 3 system (Biosense Webster, Johnson & Johnson Medical S.p.a., Irvine, CA) leveraging auto-acquisition algorithms already present in the CARTO 3 software. Mapping and ablation were performed with an irrigated tip catheter with contact force sensor. Procedure success was defined as loss of pathway function after ablation. The number of RF applications required and time to effect were measured for each patient. Recurrences were evaluated during follow-up visits. Additionally, at the end of each procedure, historical predictors of ablation success were measured offline to evaluate their relationship with the successful ablation site found with the novel workflow. Results: A total of 50 patients were analysed (62% APs right and 38% APs left). All 50 APs were successfully eliminated in each procedure with a median Time-to-effect (TTE) of 2.0 (IQR 1.2-3.5) seconds. No AP recurrences during a median follow-up of 10 (IQR 6-13) months were recorded. Offline analysis of successful ablation site revealed a pre-ablation delta/ventricular interval of ≤-10 msec in 52% of the patients and in 100% of the patients the signal related to the Kent bundle was identified. Conclusions: The novel workflow efficiently localizes APs without requiring manual annotations. Historical endocardial parameters predicting success were measured offline for each case and they corresponded to the ablation target automatically annotated by the proposed workflow. This novel mapping workflow holds promise in enhancing the efficacy of RFCA in the presence of manifest APs.

2.
Echocardiography ; 40(9): 942-951, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37503767

RESUMEN

BACKGROUND: Two-dimensional speckle tracking evaluation (2D-STE) is a useful tool to evaluate the complexity of atrial function by the analysis of the different phases of atrial deformation and by the combination with Doppler measurements of diastolic function. AIM OF THE STUDY: To evaluate the role of the left atrial (LA) strain parameters to predict worsening chronic heart failure (CHF). METHODS: We enrolled outpatients affected by CHF referred to our heart failure unit. Each patient underwent a medical visit, an electrocardiogram (ECG), and an echocardiographic examination. LA function was assessed by 2D-STE. The three phases of LA strain, that is, the reservoir (LAr), the conduit (LAcd), and the contraction (LAct)-were evaluated. Moreover, the ratio between E and LAr (E/LAr) and those between LAr and septal (LAr/Ees), lateral (LAr/Eel), and septal-lateral (LAr/Eem) E/e' were measured. During follow-up, the events related to worsening of heart failure were evaluated. RESULTS: Two hundred eleven patients were enrolled. During a mean follow-up of 14 ± 7 months, 37 patients showed at least one event related to heart failure worsening. At univariate Cox regression analysis, LAr, LAcd, LAct, E/LAr, LAr/Ees, LAr/Eel, and LAr/Eem were all associated with events related to heart failure worsening, but at multivariate regression analyses, only LAr (Hazard Ratio, HR: .95; 95% Confidence Interval, CI: .92-.99; p: .031), LAct (HR: 1.06; 95% CI: 1.01-1.12; p: .027), E/LAr (HR: 1.10; 95%CI: 1.0-1.16; p < .001), LAr/Ees (HR: .57; 95% CI: .37-.87; p: .010), and LAr/Eem (HR: .71; 95% CI: .53-.96; p: .026) remained significantly associated with the events. Finally, in a predictive model including the other relevant echocardiographic parameters LAr < 18%, LAct > -10.0%, LAr/Ees < 1.28, and E/LAr > 3.70 were associated with a statistically significant overall net reclassification improvement. CONCLUSIONS: In CHF patients, the measure of the LA reservoir and contraction by 2D-STE is independently associated with heart failure worsening, but the accuracy in predicting the events is even greater when the reservoir is combined with the Doppler measures of diastolic function.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Función del Atrio Izquierdo , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA