Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arch Cardiovasc Dis ; 117(5): 313-320, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38704288

RESUMEN

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.


Asunto(s)
Frecuencia Cardíaca , Síndrome de QT Prolongado , Valor Predictivo de las Pruebas , Dispositivos Electrónicos Vestibles , Humanos , Síndrome de QT Prolongado/fisiopatología , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/congénito , Síndrome de QT Prolongado/genética , Femenino , Masculino , Estudios Prospectivos , Niño , Adolescente , Adulto , Reproducibilidad de los Resultados , Adulto Joven , Electrocardiografía Ambulatoria/instrumentación , Potenciales de Acción , Preescolar , Diseño de Equipo , Factores de Tiempo , Persona de Mediana Edad , Electrocardiografía/instrumentación , Sistema de Conducción Cardíaco/fisiopatología
2.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38302391

RESUMEN

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Asunto(s)
Cardiología , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Sociedades Médicas
4.
Eur Heart J ; 44(46): 4847-4858, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37832512

RESUMEN

BACKGROUND AND AIMS: Intra-pocket ultrasound-guided axillary vein puncture (IPUS-AVP) for venous access in implantation of transvenous cardiac implantable electronic devices (CIED) is uncommon due to the lack of clinical evidence supporting this technique. This study investigated the efficacy and early complications of IPUS-AVP compared to the standard method using cephalic vein cutdown (CVC) for CIED implantation. METHODS: ACCESS was an investigator-led, interventional, randomized (1:1 ratio), monocentric, controlled superiority trial. A total of 200 patients undergoing CIED implantation were randomized to IPUS-AVP (n = 101) or CVC (n = 99) as a first assigned route. The primary endpoint was the success rate of insertion of all leads using the first assigned venous access technique. The secondary endpoints were time to venous access, total procedure duration, fluoroscopy time, X-ray exposure, and complications. Complications were monitored during a follow-up period of three months after procedure. RESULTS: IPUS-AVP was significantly superior to CVC for the primary endpoint with 100 (99.0%) vs. 86 (86.9%) procedural successes (P = .001). Cephalic vein cutdown followed by subclavian vein puncture was successful in a total of 95 (96.0%) patients, P = .21 vs. IPUS-AVP. All secondary endpoints were also significantly improved in the IPUS-AVP group with reduction in time to venous access [3.4 vs. 10.6 min, geometric mean ratio (GMR) 0.32 (95% confidence interval, CI, 0.28-0.36), P < .001], total procedure duration [33.8 vs. 46.9 min, GMR 0.72 (95% CI 0.67-0.78), P < .001], fluoroscopy time [2.4 vs. 3.3 min, GMR 0.74 (95% CI 0.63-0.86), P < .001], and X-ray exposure [1083 vs. 1423 mGy.cm², GMR 0.76 (95% CI 0.62-0.93), P = .009]. There was no significant difference in complication rates between groups (P = .68). CONCLUSIONS: IPUS-AVP is superior to CVC in terms of success rate, time to venous access, procedure duration, and radiation exposure. Complication rates were similar between the two groups. Intra-pocket ultrasound-guided axillary vein puncture should be a recommended venous access technique for CIED implantation.


Asunto(s)
Marcapaso Artificial , Incisión Venosa , Humanos , Incisión Venosa/métodos , Vena Axilar/cirugía , Vena Axilar/diagnóstico por imagen , Punciones , Ultrasonografía Intervencional/métodos
5.
Europace ; 25(2): 331-340, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36107465

RESUMEN

AIMS: Climate change represents the biggest global health threat of the 21st century. Health care system is itself a large contributor to greenhouse gas (GHG) emissions. In cardiology, atrial fibrillation (AF) catheter ablation is an increasing activity using numerous non-reusable materials that could contribute to GHG emission. Determining a detailed carbon footprint analysis of an AF catheter ablation procedure allows the identification of the main polluting sources that give opportunities for reduction of environmental impact. To assess the carbon footprint of AF catheter ablation procedure. To determine priority actions to decrease pollution. METHODS AND RESULTS: An eco-audit method used to predict the GHG emission of an AF catheter ablation procedure was investigated. Two workstations were considered including surgery and anaesthesia. In the operating room, every waste produced by single-use medical devices, pharmaceutical drugs, and energy consumption during intervention were evaluated. All analyses were limited to the operating room. Thirty procedures were analysed over a period of 8 weeks: 18 pulmonary veins isolation RF ablations, 7 complex RF procedures including PVI, roof and mitral isthmus lines, ethanol infusion of the Marshall vein and cavo tricuspid isthmus line, and 5 pulmonary vein isolation with cryoballoon. The mean emission during AF catheter ablation procedures was 76.9 kg of carbon dioxide equivalent (CO2-e). The operating field accounted for 75.4% of the carbon footprint, while only 24.6% for the anaesthesia workstation. On one hand, material production and manufacturing were the most polluting phases of product life cycle which, respectively, represented 71.3% (54.8 kg of CO2-e) and 17.0% (13.1 kg of CO2-e) of total pollution. On the other hand, transport contributed in 10.6% (8.1 kg of CO2-e), while product use resulted in 1.1% (0.9 kg of CO2-e) of GHG production. Electrophysiology catheters were demonstrated to be the main contributors of environmental impact with 29.9 kg of CO2-e (i.e. 38.8%). Three dimensional mapping system and electrocardiogram patches were accounting for 6.8 kg of CO2-e (i.e. 8.8% of total). CONCLUSION: AF catheter ablation involves a mean of 76.9 kg of CO2-e. With an estimated 600 000 annual worldwide procedures, the environmental impact of AF catheter ablation activity is estimated equal to 125 tons of CO2 emission each day. It represents an equivalent of 700 000 km of car ride every day. Electrophysiology catheters and patches are the main contributors of the carbon footprint. The focus must be on reducing, reusing, and recycling these items to limit the impact of AF ablation on the environment. A road map of steps to implement in different time frames is proposed.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Huella de Carbono , Dióxido de Carbono , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Resultado del Tratamiento
7.
Interv Neuroradiol ; 22(4): 378-82, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27012777

RESUMEN

BACKGROUND AND PURPOSE: Posterior communicating artery (PComA) aneurysm seems to behave uniquely compared with other intracranial aneurysms at different locations. The association between the morphology of the carotid siphon and PComA aneurysms is not well known. This study aimed to investigate whether the anatomical characteristics of the carotid siphon are associated with the formation and rupture of PComA aneurysms. METHODS: One hundred and thirty-two patients were retrospectively reviewed in a monocentric case-control study. Sixty-seven consecutive patients with PComA aneurysms were included in the case group, and 65 patients with anterior circulation aneurysm situated in other intracranial locations were included in the control group, matched by age and sex. Morphological characteristics of the carotid siphon were analyzed using angiography images. A univariate analysis was used to investigate the association between the morphological characteristics and the formation of PComA aneurysms. Furthermore, a subgroup analysis within the case group compared ruptured and non-ruptured PComA aneurysms. RESULTS: Patients with PComA aneurysm had a significantly (1.31 ± 0.70 vs. 0.82 ± 0.46; P < 0.001) larger PComA. No association was observed between the morphological characteristics of the carotid siphon and the presence of a PComA aneurysm. Likewise, subgroup analysis showed no significant association between morphological characteristics of the carotid siphon and aneurysm rupture. CONCLUSIONS: This case-control study shows that the carotid siphon morphology seems not to be related to PComA aneurysm formation or rupture.


Asunto(s)
Enfermedades de las Arterias Carótidas/complicaciones , Arteria Carótida Interna/patología , Aneurisma Intracraneal/etiología , Angiografía de Substracción Digital , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Estudios de Casos y Controles , Angiografía Cerebral , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...