Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Obes Surg ; 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38898310

RESUMEN

Robotic Roux-en-Y gastric bypass (RRYGB) is an innovative alternative to traditional laparoscopic approaches. Literature has been published investigating its safety/efficacy; however, the quality of reporting is uncertain. This systematic review used the Idea, Development, Exploration, Assessment and Long-term follow-up (IDEAL) framework to assess the reporting quality of available literature. A narrative summary was formulated, assessing how comprehensively governance/ethics, patient selection, demographics, surgeon expertise/training, technique description and outcomes were reported. Forty-seven studies published between 2005 and 2024 were included. There was incomplete/inconsistent reporting of governance/ethics, patient selection, surgeon expertise/training and technique description, with heterogenous outcome reporting. RRYGB reporting was poor and did not align with IDEAL guidance. Robust prospective studies reporting findings using IDEAL/other guidance are required to facilitate safe widespread adoption of RRYGB and other surgical innovations.

2.
Med Sci (Basel) ; 12(1)2024 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-38249082

RESUMEN

Vein grafts are the most used conduits in coronary artery bypass grafting (CABG), even though many studies have suggested their lower patency compared to arterial alternatives. We have reviewed the techniques and technologies that have been investigated over the years with the aim of improving the quality of these conduits. We found that preoperative and postoperative optimal medical therapy and no-touch harvesting techniques have the strongest evidence for optimizing vein graft patency. On the other hand, the use of venous external support, endoscopic harvesting, vein preservation solution and anastomosis, and graft configuration need further investigation. We have also analyzed strategies to treat vein graft failure: when feasible, re-doing the CABG and native vessel primary coronary intervention (PCI) are the best options, followed by percutaneous procedures targeting the failed grafts.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Intervención Coronaria Percutánea , Puente de Arteria Coronaria , Corazón , Tecnología
3.
Am J Cardiol ; 209: 104-113, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-37848175

RESUMEN

Although surgical ablation has been shown to produce excellent outcomes at follow-up for patients with atrial fibrillation who underwent mitral valve replacement/repair (MVR), this procedure is not commonly performed. Our objective was to conduct a systematic review and meta-analysis to evaluate the outcomes of concomitant surgical ablation during MVR. Three databases were systematically reviewed for randomized clinical trials published by August 2022. The primary outcome was sinus rhythm (SR) at 12 months. Secondary outcomes included SR at discharge and 6 months, all-cause mortality, permanent pacemaker implantation, and stroke and thromboembolic events. A random-effects meta-analysis was performed, calculating odds ratios (ORs) for each outcome. Thirteen studies were included, involving 1,089 patients comparing patients who underwent either isolated MVR ("MVR-only") or concomitant surgical ablation during MVR ("MVR+Ablation"). The odds of SR were significantly higher in the MVR+Ablation group at discharge (OR 9.62, 95% confidence interval [CI] 4.87 to 19.02, I2 = 55%), at 6-month follow-up (OR 7.21, 95% CI 4.30 to 12.11, I2 = 34%), and at 1-year follow-up (OR 8.41, 95% CI 5.14 to 13.77, I2 = 48%). All-cause mortality was not different in the groups, as were stroke and thromboembolic events, whereas the odds of permanent pacemaker implantation were slightly higher in the MVR+Ablation group (OR 1.87, 95% CI 1.11 to 3.17, I2 = 0%). Concomitant surgical ablation during MVR showed excellent outcomes at short-term follow-up, despite a slightly higher rate of permanent pacemaker implantation. Further studies with longer follow-ups are needed to assess if the SR is maintained over the years.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Válvula Mitral/cirugía , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Ablación por Catéter/métodos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/métodos
4.
JCI Insight ; 8(5)2023 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-36749631

RESUMEN

The glomerular endothelial glycocalyx (GEnGlx) forms the first part of the glomerular filtration barrier. Previously, we showed that mineralocorticoid receptor (MR) activation caused GEnGlx damage and albuminuria. In this study, we investigated whether MR antagonism could limit albuminuria in diabetes and studied the site of action. Streptozotocin-induced diabetic Wistar rats developed albuminuria, increased glomerular albumin permeability (Ps'alb), and increased glomerular matrix metalloproteinase (MMP) activity with corresponding GEnGlx loss. MR antagonism prevented albuminuria progression, restored Ps'alb, preserved GEnGlx, and reduced MMP activity. Enzymatic degradation of the GEnGlx negated the benefits of MR antagonism, confirming their dependence on GEnGlx integrity. Exposing human glomerular endothelial cells (GEnC) to diabetic conditions in vitro increased MMPs and caused glycocalyx damage. Amelioration of these effects confirmed a direct effect of MR antagonism on GEnC. To confirm relevance to human disease, we used a potentially novel confocal imaging method to show loss of GEnGlx in renal biopsy specimens from patients with diabetic nephropathy (DN). In addition, patients with DN randomized to receive an MR antagonist had reduced urinary MMP2 activity and albuminuria compared with placebo and baseline levels. Taken together, our work suggests that MR antagonists reduce MMP activity and thereby preserve GEnGlx, resulting in reduced glomerular permeability and albuminuria in diabetes.


Asunto(s)
Diabetes Mellitus , Nefropatías Diabéticas , Ratas , Animales , Humanos , Antagonistas de Receptores de Mineralocorticoides/farmacología , Antagonistas de Receptores de Mineralocorticoides/uso terapéutico , Antagonistas de Receptores de Mineralocorticoides/metabolismo , Albuminuria/tratamiento farmacológico , Células Endoteliales/metabolismo , Receptores de Mineralocorticoides/metabolismo , Receptores de Mineralocorticoides/uso terapéutico , Glicocálix/metabolismo , Ratas Wistar , Nefropatías Diabéticas/metabolismo , Diabetes Mellitus/metabolismo
5.
J Robot Surg ; 17(2): 313-324, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36074220

RESUMEN

Robot-assisted anti-reflux surgery (RA-ARS) is increasingly being used to treat refractory gastro-oesophageal reflux disease. The IDEAL (Idea, Development, Exploration, Assessment, Long-term follow up) Collaboration's framework aims to improve the evaluation of surgical innovation, but the extent to which the evolution of RA-ARS has followed this model is unclear. This study aims to evaluate the standard to which RA-ARS has been reported during its evolution, in relation to the IDEAL framework. A systematic review from inception to June 2020 was undertaken to identify all primary English language studies pertaining to RA-ARS. Studies of paraoesophageal or giant hernias were excluded. Data extraction was informed by IDEAL guidelines and summarised by narrative synthesis. Twenty-three studies were included: two case reports, five case series, ten cohort studies and six randomised controlled trials. The majority were single-centre studies comparing RA-ARS and laparoscopic Nissen fundoplication. Eleven (48%) studies reported patient selection criteria, with high variability between studies. Few studies reported conflicts of interest (30%), funding arrangements (26%), or surgeons' prior robotic experience (13%). Outcome reporting was heterogeneous; 157 distinct outcomes were identified. No single outcome was reported in all studies.The under-reporting of important aspects of study design and high degree of outcome heterogeneity impedes the ability to draw meaningful conclusions from the body of evidence. There is a need for further well-designed prospective studies and randomised trials, alongside agreement about outcome selection, measurement and reporting for future RA-ARS studies.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Fundoplicación , Estudios Prospectivos , Resultado del Tratamiento , Procedimientos Quirúrgicos Robotizados/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...