Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Pharm Biomed Anal ; 32(1): 107-23, 2003 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-12852453

RESUMEN

A robust, automated enzyme inhibition assay method was developed and validated for the determination of HMG-CoA reductase inhibitory activities in plasma and urine samples following simvastatin (SV) administration. The assay was performed on Tecan Genesis 150 and 200 systems equipped with 8-probe and 96-well plates. Plasma samples containing HMG-CoA reductase inhibitors were treated with acetonitrile for protein precipitation before being incubated with HMG-CoA reductase, [14C]-HMG-CoA, and NADPH for a fixed length of time at a fixed temperature. The product, [14C]-mevalonic acid, was lactonized and separated from excess substrate via a small ion exchange resin column, and radioactivity was counted on a scintillation counter. HMG-CoA reductase inhibitors were measured before and after base hydrolysis. The two values obtained for each sample are referred to as 'active' and 'total' HMG-CoA reductase inhibitor concentrations. Simvastatin acid (SVA), the beta-hydroxy acid of SV, was used as a standard to generate a calibration curve of HMG-CoA reductase activity versus SVA concentration (ng/ml). Three calibration ranges, 0.4-20, 2-50, and 50, 100 ng/ml, in human and animal plasma and urine were validated. The assay precision was less than 8.5%, CV in plasma and less than 10.4% in urine. The assay accuracy was 93.6-103.0 and 98.1-103.9% for the 0.4 20 and 2-50 ng/ml calibration ranges, respectively, in human plasma, and was 97.3-105.1, 94.4- 105.2, and 90.2-95.7%, for calibration range 5-100 ng/ml in rat plasma, dog plasma and human urine, respectively.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas/análisis , Simvastatina/análogos & derivados , Simvastatina/análisis , Animales , Autoanálisis , Radioisótopos de Carbono , Perros , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/sangre , Inhibidores de Hidroximetilglutaril-CoA Reductasas/orina , Indicadores y Reactivos , Ratas , Reproducibilidad de los Resultados , Robótica , Sensibilidad y Especificidad , Simvastatina/sangre , Simvastatina/orina
2.
J Clin Lab Anal ; 16(5): 209-15, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12357448

RESUMEN

The cholesterol-lowering drug simvastatin (SIMV, Zocor reduced heart attacks by 42% in patients who had high cholesterol levels and suffered from heart disease. Upon oral administration, SIMV is quickly hydrolyzed to its beta-hydroxyacid and other acid metabolites, which are potent inhibitors of 3-hydroxy-3-methylglutaryl coenzyme A reductase. A Tecan-based enzyme inhibition assay has been developed to improve the existing Zymark-based assay for the determination of both active and total concentrations of HMG-CoA reductase inhibitors in human plasma. A Tecan Genesis 200 robotic workstation equipped with eight probes and customized hardware was utilized to achieve higher sample throughput and improve assay reproducibility and mechanical stability. The developed enzyme inhibition assay was validated over two concentration ranges of 0.4-20 ng equivalent/mL, and 2-50 ng equivalent/mL. Intra- and interday precision data (coefficient of variation (CV)) for both concentration ranges were less than 9%, with an accuracy of 93-107%. The interday precision for the determination of quality control (QC) samples was less than 2% and 8%, respectively. The respective interday QC accuracy values were 93-103% and 97-104%. Good linearity across the two concentration ranges was observed, with acceptable reproducibility. This improved enzyme inhibition assay has been utilized to analyze human plasma samples from several clinical studies.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas/sangre , Simvastatina/sangre , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...