Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Vaccine ; 31(34): 3435-41, 2013 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-23398932

RESUMEN

Delivery of influenza vaccine using innovative approaches such as microneedles has been researched extensively in the past decade. In this study we present concentration followed by formulation and coating of monobulks from 2008/2009 seasonal vaccine on to 3M's solid microstructured transdermal system (sMTS) by a GMP-scalable process. The hemagglutinin (HA) in monobulks was concentrated by tangential flow filtration (TFF) to achieve HA concentrations as high as 20mg/ml. The stability of the coated antigens was evaluated by the functional assay, single radial immunodiffusion (SRID). The data generated show stability of the coated antigen upon storage at 4°C and room temperature in the presence of desiccant for at least 8 weeks. Freeze-thaw stability data indicate the stability of the coated antigen in stressed conditions. The vaccine coated microstructures were evaluated in vivo in a guinea pig model, and resulted in immune titers comparable to the traditional trivalent vaccine administered intramuscularly. The data presented indicate the potential use of the technology in delivery of influenza vaccine. This paper also addresses the key issues of stability of coated antigen, reproducibility and scalability of the processes used in preparation of influenza vaccine coated microneedle patches that are important in developing a successful product.


Asunto(s)
Vacunas contra la Influenza/administración & dosificación , Infecciones por Orthomyxoviridae/inmunología , Parche Transdérmico , Administración Cutánea , Animales , Anticuerpos Antivirales/sangre , Antígenos Virales/administración & dosificación , Antígenos Virales/inmunología , Estabilidad de Medicamentos , Femenino , Cobayas , Pruebas de Inhibición de Hemaglutinación , Glicoproteínas Hemaglutininas del Virus de la Influenza/administración & dosificación , Glicoproteínas Hemaglutininas del Virus de la Influenza/inmunología , Vacunas contra la Influenza/inmunología , Inyecciones Intramusculares , Ratones , Ratones Endogámicos BALB C , Infecciones por Orthomyxoviridae/prevención & control , Reproducibilidad de los Resultados , Vacunación/instrumentación , Vacunación/métodos , Vacunas de Subunidad/administración & dosificación , Vacunas de Subunidad/inmunología
2.
Med Device Technol ; 20(2): 32, 34, 36-8, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19405341

RESUMEN

To maintain a high standard of quality in the materials and components used in the container systems of orally inhaled and nasal drug products, manufacturers need to collaborate closely with all those in the supply chain. Best practices in information sharing, particularly in relation to change control, are outlined here.


Asunto(s)
Materiales Biocompatibles/química , Materiales Manufacturados/normas , Preparaciones Farmacéuticas/administración & dosificación , Preparaciones Farmacéuticas/química , Polímeros/química , Administración por Inhalación , Administración Intranasal , Administración Oral , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Guías como Asunto , Humanos , Control de Calidad
3.
Anal Chem ; 66(14): 2285-92, 1994 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-8080105

RESUMEN

A new detector for macromolecular separations is described. The detector counts individual macromolecules (molecular weights greater than about 10,000) and reports counts per second. The chromatographic effluent is electrosprayed, neutralized, and swept to the detector by a stream of air. The detector is a condensation particle counter that detects individual particles by light scattering from droplets condensed on the particles. When used as the detector for a size exclusion separation of proteins, the detector has a linear range of 4 orders of magnitude with detection limits as low as 0.1 microgram/mL. The detector can be directly interfaced (no makeup flow) with effluent flows as low as 10 nL/min. A Monte Carlo model based on size measurements of the electrosprayed droplets correctly predicts the observed detector behavior.


Asunto(s)
Biopolímeros/química , Carbohidratos/química , Cromatografía Liquida , Peso Molecular , Poliestirenos/química , Proteínas/química , Espectrofotometría Ultravioleta
4.
Anal Chem ; 63(8): 807-10, 1991 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-1877749

RESUMEN

A new liquid chromatography instrument is described that employs small-diameter capillary columns and an optically controlled sample gating procedure to separate a mixture of fluorescein isothiocyanate (FITC) labeled amines in as few as 6 s. Efficiency of the separation, expressed as the number of theoretical plates, is observed to increase linearly with column length and thus analysis time. The combination of short analysis time and automated sample introduction allows signal averaging to be used to enhance the precision of the measurement.


Asunto(s)
Cromatografía Liquida/métodos , Automatización , Cromatografía Liquida/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA