1.
Ergonomics ; 67(6): 866-880, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38770836

RESUMEN

By conducting a mixed-design experiment using simplified accident handling tasks performed by two-person teams, this study examined the effects of automation function and condition (before, during, and after malfunction) on human performance. Five different and non-overlapping functions related to human information processing model were considered and their malfunctions were set in a first-failure way. The results showed that while the automation malfunction impaired task performance, the performance degradation for information analysis was more severe than response planning. Contrary to other functions, the situation awareness for response planning and response implementation tended to increase during malfunctioning and decrease after. In addition, decreased task performance reduced trust in automation, and malfunctions in earlier stages of information processing resulted in lower trust. Suggestions provided for the design and training related to automation emphasise the importance of high-level cognitive support and the benefit of involving automation error handling in training.


The effects of automation function and malfunction on human performance are important for design and training. The experimental results in this study revealed the significance of high-level cognitive support. Also, introducing automation error handling in training can be helpful in improving situation awareness of the teams.


Asunto(s)
Automatización , Análisis y Desempeño de Tareas , Humanos , Masculino , Femenino , Adulto , Adulto Joven , Sistemas Hombre-Máquina , Confianza , Concienciación
2.
Sci Rep ; 14(1): 7038, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38528073

RESUMEN

Both regular flow and infrequent outburst floods shape the mountain landscape, but their relative contributions have been widely debated, in part due to the paucity of quantitative data on historical outburst floods. In June 2000, an outburst flood was triggered by a landslide-dam failure in a rapidly exhumed region of the Eastern Himalaya. To investigate the role of this kind outburst flood on landscape evolution, we employ topographic differencing, satellite imagery, and 2D hydraulic simulations to quantify the equivalent erosion and deposition within ~ 80 km flood route downstream of the breach. The flood lasted for ~ 10 h, with a peak discharge of 105 m3/s, leading to average erosion of 10 m, and contributed ~ 1-2 × 103 times more sediment than over long-term mean fluvial processes. The flood produced extensive lateral erosion, which triggered a threefold widening of the valley floor and abundant subsequent landslides. The ubiquitous boulder bars deposited in the channel inhibited incision, and facilitated lateral erosion after the flood. The resulting channel configuration and extensive bank erosion continue to affect fluvial dynamics until the next catastrophic flood that remobilizes the boulders. Our quantitative findings highlight the profound importance of recurrent outburst floods for gorge development and landscape evolution in Eastern Himalaya.

3.
Ergonomics ; 56(7): 1070-85, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23654299

RESUMEN

Mental workload is a major consideration for the design of emergency operation procedures (EOPs) in nuclear power plants. Continuous and objective measures are desired. This paper compares seven mental workload measurement methods (pupil size, blink rate, blink duration, heart rate variability, parasympathetic/sympathetic ratio, total power and (Goals, Operations, Methods, and Section Rules)-(Keystroke Level Model) GOMS-KLM-based workload index) with regard to sensitivity, validity and intrusiveness. Eighteen participants performed two computerised EOPs of different complexity levels, and mental workload measures were collected during the experiment. The results show that the blink rate is sensitive to both the difference in the overall task complexity and changes in peak complexity within EOPs, that the error rate is sensitive to the level of arousal and correlate to the step error rate and that blink duration increases over the task period in both low and high complexity EOPs. Cardiac measures were able to distinguish tasks with different overall complexity. The intrusiveness of the physiological instruments is acceptable. Finally, the six physiological measures were integrated using group method of data handling to predict perceived overall mental workload. PRACTITIONER SUMMARY: The study compared seven measures for evaluating the mental workload with emergency operation procedure in nuclear power plants. An experiment with simulated procedures was carried out, and the results show that eye response measures are useful for assessing temporal changes of workload whereas cardiac measures are useful for evaluating the overall workload.


Asunto(s)
Plantas de Energía Nuclear , Estrés Psicológico/fisiopatología , Carga de Trabajo/psicología , Adulto , Nivel de Alerta , Parpadeo , Urgencias Médicas/psicología , Frecuencia Cardíaca , Humanos , Masculino , Política Organizacional , Sistema Nervioso Parasimpático/fisiología , Pupila/fisiología , Sistema Nervioso Simpático/fisiología , Adulto Joven
4.
Sleep Breath ; 16(3): 717-22, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21928076

RESUMEN

OBJECTIVE: This study aims to examine the impact of chronic intermittent hypoxia on hearts in patients with obstructive sleep apnea (OSA). METHODS: Two hundred twenty patients were divided into groups based on (1) severity of the disease, (2) years of disease history, and (3) with or without secondary hypertension. All subjects underwent blood pressure measurements, polysomnogram monitoring, and cardiac Doppler ultrasound examinations. RESULTS: The left ventricular ejection fraction (LVEF), fractional shortening (FS), and the ratio of early to late diastolic filling (E/A) in patients with severe OSA were lower than in those with moderate OSA and in healthy controls. The inner diameters of the main pulmonary artery (inD of MPA), the inner diameters of the right cardiac ventricle (inD of RV), and the thickness of anterior wall of the right ventricle (TAW of RV) were increased in patients with severe OSA compared to those with moderate disease and worsened as a function of time with disease. The tissue Doppler imaging-derived Tei index and pulmonary artery systolic pressure were also increased along with the severity of OSA. LVEF and FS in patients who had suffered from OSA for >10 years were decreased compared with those suffering from OSA for a shorter time. LVEF and FS in patients with secondary hypertension were decreased significantly relative to non-hypertensive OSA patients and healthy controls. E/A was decreased in OSA patients whether they had secondary hypertension or not. CONCLUSION: OSA affected the left ventricular diastolic function in the early stage of the disease. Extended exposure to OSA resulted in left ventricular dysfunction with increased hypertension. Right ventricle dysfunction and abnormalities became more severe as the disease progressed.


Asunto(s)
Hemodinámica/fisiología , Hipoxia/fisiopatología , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Consumo de Bebidas Alcohólicas/efectos adversos , Consumo de Bebidas Alcohólicas/fisiopatología , Índice de Masa Corporal , Progresión de la Enfermedad , Ecocardiografía , Diagnóstico por Imagen de Elasticidad , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Hipoxia/diagnóstico , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Polisomnografía , Valores de Referencia , Apnea Obstructiva del Sueño/diagnóstico , Fumar/efectos adversos , Fumar/fisiopatología , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Derecha/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...