Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1043710

RESUMEN

Objective@#: Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. @*Methods@#: This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. @*Results@#: The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. @*Conclusion@#: In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.

2.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-915598

RESUMEN

Objective@#: The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. @*Methods@#: We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24–70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. @*Results@#: Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. @*Conclusion@#: Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.

3.
Yonsei Medical Journal ; : 72-81, 2022.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-919611

RESUMEN

Purpose@#The purpose of this retrospective study was to evaluate radiological and clinical outcomes in patients undergoing cervical disc arthroplasty (CDA) for cervical degenerative disc disease. The results may assist in surgical decision-making and enable more effective and safer implementation of cervical arthroplasty. @*Materials and Methods@#A total of 125 patients who were treated with CDA between 2006 and 2019 were assessed. Radiological measurements and clinical outcomes included the visual analogue scale (VAS), the Neck Disability Index (NDI), and the Japanese Orthopaedic Association (JOA) myelopathy score assessment preoperatively and at ≥2 years of follow-up. @*Results@#The mean follow-up period was 38 months (range, 25–114 months). Radiographic data demonstrated mobility at both the index and adjacent levels, with no signs of hypermobility at an adjacent level. There was a non-significant loss of cervical global motion and range of motion (ROM) of the functional spinal unit at the operated level, as well as the upper and lower adjacent disc levels, compared to preoperative status. The cervical global and segmental angle significantly increased. Postoperative neck VAS, NDI, and JOA scores showed meaningful improvements after one- and two-level CDA. We experienced a 29.60% incidence of heterotrophic ossification and a 3.20% reoperation rate due to cervical instability, implant subsidence, or osteolysis. @*Conclusion@#CDA is an effective surgical technique for optimizing clinical outcomes and radiological results. In particular, the preservation of cervical ROM with an artificial prosthesis at adjacent and index levels and improvement in cervical global alignment could reduce revision rates due to adjacent segment degeneration.

4.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-915587

RESUMEN

Objective@#: Vertebral artery dissecting aneurysm (VADA) is a very rare subtype of intracranial aneurysms; when ruptured, it is associated with significantly high rates of morbidity and mortality. Despite several discussions and debates, the optimal treatment for VADA has not yet been established. In the last 10 years, flow diverter devices (FDD) have emerged as a challenging and new treatment method, and various clinical and radiological results have been reported about their safety and effectiveness. The aim of our study was to evaluate the clinical and radiological results with the use of FDD in the treatment of unruptured VADA. @*Methods@#: We retrospectively evaluated the data of all patients with unruptured VADA treated with FDD between January 2018 and February 2021 at our hybrid operating room. Nine patients with unruptured VADA, deemed hemodynamically unstable, were treated with FDD. Among other parameters, the technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcomes were evaluated. @*Results@#: Successful FDD deployment was achieved in all cases, and the immediate follow-up angiography showed intra-aneurysmal contrast stasis with parent artery preservation. A temporary episode of facial numbness and palsy was noted in one patient; however, the symptoms had completely disappeared when followed up at the outpatient clinic 2 weeks after the procedure. The 3–6 months follow-up angiography (n=9) demonstrated completeear-complete obliteration of the aneurysm in seven patients, and partial obliteration and segmental occlusion in one patient each. In the patient who achieved only partial obliteration, there was a sac 13 mm in size, and there was no change in the 1-year follow-up angiography. In the patient with segmental occlusion, the cause could not be determined. The clinical outcome was modified Rankin Scale 0 in all patients. @*Conclusion@#: Our preliminary study using FDD to treat hemodynamically unstable unruptured VADA showed that FDD is safe and effective. Our study has limitations in that the number of cases is small, and it is not a prospective study. However, we believe that the study contributes to evidence regarding the safety and effectiveness of FDD in the treatment of unruptured VADA.

5.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-900111

RESUMEN

Objective@#: Oblique lateral interbody fusion (OLIF) is becoming the preferred treatment for degenerative lumbar diseases. As beginners, we performed 143 surgeries over 19 months. In these consecutive cases, we analyzed the learning curve and reviewed the complications in our experience. @*Methods@#: This was a retrospective study; however, complications that were well known in the previous literature were strictly recorded prospectively. We followed up the changes in estimated blood loss (EBL), operation time, and transient psoas paresis according to case accumulation to analyze the learning curve. @*Results@#: Complication-free patients accounted for 43.6% (12.9%, early stage 70 patients and 74.3%, late stage 70 patients). The most common complication was transient psoas paresis (n=52). Most of these complications occurred in the early stages of learning. C-reactive protein normalization was delayed in seven patients (4.89%). The operation time showed a decreasing trend with the cases; however, EBL did not show any significant change. Notable operation-induced complications were cage malposition, vertebral body fracture, injury to the ureter, and injury to the lumbar vein. @*Conclusion@#: According to the learning curve, the operation time and psoas paresis decreased. It is important to select an appropriately sized cage along with clear dissection of the anterior border of the psoas muscle to prevent OLIF-specific complications.

6.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-900144

RESUMEN

Many studies have focused on pre-operative sagittal alignment parameters which could predict poor clinical or radiological outcomes after laminoplasty. However, the influx of too many new factors causes confusion. This study reviewed sagittal alignment parameters, predictive of clinical or radiological outcomes, in the literature. Preoperative kyphotic alignment was initially proposed as a predictor of clinical outcomes. The clinical significance of the K-line and K-line variants also has been studied. Sagittal vertical axis, T1 slope (T1s), T1s-cervical lordosis (CL), anterolisthesis, local kyphosis, the longitudinal distance index, and range of motion were proposed to have relationships with clinical outcomes. The relationship between loss of cervical lordosis (LCL) and T1s has been widely studied, but controversy remains. Extension function, the ratio of CL to T1s (CL/T1s), and Sharma classification were recently proposed as LCL predictors. In predicting postoperative kyphosis, T1s cannot predict postoperative kyphosis, but a low CL/T1s ratio was associated with postoperative kyphosis.

7.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-892407

RESUMEN

Objective@#: Oblique lateral interbody fusion (OLIF) is becoming the preferred treatment for degenerative lumbar diseases. As beginners, we performed 143 surgeries over 19 months. In these consecutive cases, we analyzed the learning curve and reviewed the complications in our experience. @*Methods@#: This was a retrospective study; however, complications that were well known in the previous literature were strictly recorded prospectively. We followed up the changes in estimated blood loss (EBL), operation time, and transient psoas paresis according to case accumulation to analyze the learning curve. @*Results@#: Complication-free patients accounted for 43.6% (12.9%, early stage 70 patients and 74.3%, late stage 70 patients). The most common complication was transient psoas paresis (n=52). Most of these complications occurred in the early stages of learning. C-reactive protein normalization was delayed in seven patients (4.89%). The operation time showed a decreasing trend with the cases; however, EBL did not show any significant change. Notable operation-induced complications were cage malposition, vertebral body fracture, injury to the ureter, and injury to the lumbar vein. @*Conclusion@#: According to the learning curve, the operation time and psoas paresis decreased. It is important to select an appropriately sized cage along with clear dissection of the anterior border of the psoas muscle to prevent OLIF-specific complications.

8.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-892440

RESUMEN

Many studies have focused on pre-operative sagittal alignment parameters which could predict poor clinical or radiological outcomes after laminoplasty. However, the influx of too many new factors causes confusion. This study reviewed sagittal alignment parameters, predictive of clinical or radiological outcomes, in the literature. Preoperative kyphotic alignment was initially proposed as a predictor of clinical outcomes. The clinical significance of the K-line and K-line variants also has been studied. Sagittal vertical axis, T1 slope (T1s), T1s-cervical lordosis (CL), anterolisthesis, local kyphosis, the longitudinal distance index, and range of motion were proposed to have relationships with clinical outcomes. The relationship between loss of cervical lordosis (LCL) and T1s has been widely studied, but controversy remains. Extension function, the ratio of CL to T1s (CL/T1s), and Sharma classification were recently proposed as LCL predictors. In predicting postoperative kyphosis, T1s cannot predict postoperative kyphosis, but a low CL/T1s ratio was associated with postoperative kyphosis.

9.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-917970

RESUMEN

Objective@#Ventriculoatrial shunt (VAS) remains an alternate option for treatment of hydrocephalus in patients with ventriculoperitoneal shunt (VPS) failure. Unfamiliar anatomy for a neurosurgeon has resulted in the VAS falling out of favor as a treatment option. However, there are unsatisfactory reports on the long-term result of VPS, and VAS has been recently re-evaluated. We are to report the simple way to do the VAS using a peel-away sheath in a hybrid operation room. @*Methods@#A jugular vein path was drawn by ultrasound, a small incision was made above the clavicle, and a shunt catheter was tunneled into it. The jugular vein was punctured beside the tunneled catheter with a Seldinger needle under ultrasound guidance. A flexible guide wire was introduced into the vein and 6-Fr peel-away sheath was advanced into the vein along the wire. Under fluoroscopic guidance, the catheter was cut to position approximately midlevel in the atrium. After the guide wire was removed, the distal shunt catheter was passed down. After confirming proper position of the distal catheter under the fluoroscope, the catheter-guiding sheath was pulled out as a peeling-away manner. We performed this surgical procedures in 5 cases. @*Results@#All the procedures of the VAS using a peel-away sheath were performed in a hybrid operation room Of 5 patients, 3 patients had the distal catheter failures in the peritoneal cavity and 2 patients had shunt A distal catheter was successfully indwelling in all the cases without any difficulties. After the surgery, neither shunt infection nor thromboembolic event happened. @*Conclusion@#VAS using fluoroscopy and a peel-away sheath is a good alternative option for hydrocephalus patients with shunt failure related to peritoneal cavity complications.

10.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-918002

RESUMEN

Objective@#Recently, many studies have reported that cervical alignment is related to clinical outcomes. However, poor visibility of anatomical structures during X-ray (XR) imaging limits accurate measurements. In supine magnetic resonance (MR) imaging, the boundary of the anatomical structure is clear, but the correlation to XR images taken in a standing position is problematic. In this study, we evaluated the agreement of sagittal alignment parameters between MR and XR measurements. @*Methods@#We retrospectively reviewed 268 patients. Cervical sagittal parameters were measured using XR and MR images, and their relationships were evaluated using Pearson's correlation, paired t-tests, and 2-way random, single score intraclass correlation coefficient (ICCs) (2,1). Using simple linear regression analysis, MR results were converted to the expected value (MR-E). The subsequent comparison of MR-Es with XRs was used to examine whether MR-Es could replace XRs when the measurement difference was less than 2 mm or 2°. @*Results@#The correlation between the MR and XR measurements was high, but ICCs showed low reliability. All parameters were significantly different between XR and MR measurements in paired t-tests. Converting the MR values eliminated the t-test differences between MR-Es and XRs, but did not affect correlations and ICCs. The replacement ratio included the Cobb angle: 20.3%, T1: 27.1%, the sagittal vertical axis: 17.6%, C1–2: 29.7%, and C2: 16.0%. @*Conclusion@#These results indicate that supine MR measurements could not replace upright XR measurements.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA