Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomedicines ; 11(12)2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38137347

RESUMEN

Multiple sclerosis (MS) and Alzheimer's disease (AD) cause retinal thinning that is detectable in vivo using optical coherence tomography (OCT). To date, no papers have compared the two diseases in terms of the structural differences they produce in the retina. The purpose of this study is to analyse and compare the neuroretinal structure in MS patients, AD patients and healthy subjects using OCT. Spectral domain OCT was performed on 21 AD patients, 33 MS patients and 19 control subjects using the Posterior Pole protocol. The area under the receiver operating characteristic (AUROC) curve was used to analyse the differences between the cohorts in nine regions of the retinal nerve fibre layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL) and outer nuclear layer (ONL). The main differences between MS and AD are found in the ONL, in practically all the regions analysed (AUROCFOVEAL = 0.80, AUROCPARAFOVEAL = 0.85, AUROCPERIFOVEAL = 0.80, AUROC_PMB = 0.77, AUROCPARAMACULAR = 0.85, AUROCINFERO_NASAL = 0.75, AUROCINFERO_TEMPORAL = 0.83), and in the paramacular zone (AUROCPARAMACULAR = 0.75) and infero-temporal quadrant (AUROCINFERO_TEMPORAL = 0.80) of the GCL. In conclusion, our findings suggest that OCT data analysis could facilitate the differential diagnosis of MS and AD.

2.
Mult Scler Relat Disord ; 74: 104725, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37086637

RESUMEN

BACKGROUND: Current procedures for diagnosing multiple sclerosis (MS) present a series of limitations, making it critically important to identify new biomarkers. The aim of the study was to identify new biomarkers for the early diagnosis of MS using spectral-domain optical coherence tomography (OCT) and artificial intelligence. METHODS: Spectral domain OCT was performed on 79 patients with relapsing-remitting multiple sclerosis (RRMS) (disease duration ≤ 2 years, no history of optic neuritis) and on 69 age-matched healthy controls using the posterior pole protocol that incorporates the anatomic Positioning System. Median retinal thickness values in both eyes and inter-eye difference in healthy controls and patients were evaluated by area under the receiver operating characteristic (AUROC) curve analysis in the foveal, parafoveal and perifoveal areas and in the overall area spanned by the three rings. The structures with the greatest discriminant capacity - retinal thickness and inter-eye difference - were used as inputs to a convolutional neural network to assess the diagnostic capability. RESULTS: Analysis of retinal thickness and inter-eye difference in RRMS patients revealed that greatest alteration occurred in the ganglion cell (GCL), inner plexiform (IPL), and inner retinal (IRL) layers. By using the average thickness of the GCL (AUROC = 0.82) and the inter-eye difference in the IPL (AUROC = 0.71) as inputs to a two-layer convolutional neural network, automatic diagnosis attained accuracy = 0.87, sensitivity = 0.82, and specificity = 0.92. CONCLUSION: This study adds weight to the argument that neuroretinal structure analysis could be incorporated into the diagnostic criteria for MS.


Asunto(s)
Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Células Ganglionares de la Retina , Inteligencia Artificial , Tomografía de Coherencia Óptica , Retina/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...