Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Biol Macromol ; 275(Pt 2): 133655, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38969029

RESUMEN

Integrated wound care, a sequential process of promoting wound hemostasis, sealing, and healing, is of great clinical significance. However, the wet environment of wounds poses formidable challenges for integrated care. Herein, we developed an epidermal growth factor (EGF)-loaded, dehydrated physical microgel (DPM)-formed adhesive hydrogel for the integrated care of wet wounds. The DPMs were designed using the rational combination of hygroscopicity and reversible crosslinking of physical hydrogels. Unlike regular bioadhesives, which consider interfacial water as a barrier to adhesion, DPMs utilize water to form desirable adhesive structures. The hygroscopicity allowed the DPMs to absorb interfacial water and subsequently, the interfacial adhesion was realized by the interactions between tissue and DPMs. The reversible crosslinks further enabled DPMs to integrate into hydrogels (DPM-Gels), thus achieving wet adhesion. Importantly, the water-absorbing gelation mode of DPMs enabled facile loading of biologically active EGF to promote wound healing. We demonstrated that the DPM-Gels possessed wet tissue adhesive performance, with about 40 times the wet adhesive strength of fibrin glue and about 4 times the burst pressure of human blood pressure. Upon application at the injury site, the EGF-loaded DPM-Gels sequentially promoted efficient wound hemostasis, stable sealing, and quick healing, achieving integrated care of wet wounds.

2.
Acta Biomater ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936752

RESUMEN

Integrated wound care through sequentially promoting hemostasis, sealing, and healing holds great promise in clinical practice. However, it remains challenging for regular bioadhesives to achieve integrated care of dynamic wounds due to the difficulties in adapting to dynamic mechanical and wet wound environments. Herein, we reported a type of dehydrated, physical double crosslinked microgels (DPDMs) which were capable of in situ forming highly stretchable, compressible and tissue-adhesive hydrogels for integrated care of dynamic wounds. The DPDMs were designed by the rational integration of the reversible crosslinks and double crosslinks into micronized gels. The reversible physical crosslinks enabled the DPDMs to integrate together, and the double crosslinked characteristics further strengthen the formed macroscopical networks (DPDM-Gels). We demonstrated that the DPDM-Gels simultaneously possess outstanding tensile (∼940 kJ/m3) and compressive (∼270 kJ/m3) toughness, commercial bioadhesives-comparable tissue-adhesive strength, together with stable performance under hundreds of deformations. In vivo results further revealed that the DPDM-Gels could effectively stop bleeding in various bleeding models, even in an actual dynamic environment, and enable the integrated care of dynamic skin wounds. On the basis of the remarkable mechanical and appropriate adhesive properties, together with impressive integrated care capacities, the DPDM-Gels may provide a new approach for the smart care of dynamic wounds. STATEMENT OF SIGNIFICANCE: Integrated care of dynamic wounds holds great significance in clinical practice. However, the dynamic and wet wound environments pose great challenges for existing hydrogels to achieve it. This work developed robust adhesive hydrogels for integrated care of dynamic wounds by designing dehydrated, physical double crosslinked microgels (DPDMs). The reversible and double crosslinks enabled DPDMs to integrate into macroscopic hydrogels with high mechanical properties, appropriate adhesive strength and stable performance under hundreds of external deformations. Upon application at the injury site, DPDM-Gels efficiently stopped bleeding, even in an actual dynamic environment and showed effectiveness in integrated care of dynamic wounds. With the fascinating properties, DPDMs may become an effective tool for smart wound care.

3.
Int J Mol Sci ; 25(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38791286

RESUMEN

In clinical practice, tissue adhesives have emerged as an alternative tool for wound treatments due to their advantages in ease of use, rapid application, less pain, and minimal tissue damage. Since most tissue adhesives are designed for internal use or wound treatments, the biodegradation of adhesives is important. To endow tissue adhesives with biodegradability, in the past few decades, various biodegradable polymers, either natural polymers (such as chitosan, hyaluronic acid, gelatin, chondroitin sulfate, starch, sodium alginate, glucans, pectin, functional proteins, and peptides) or synthetic polymers (such as poly(lactic acid), polyurethanes, polycaprolactone, and poly(lactic-co-glycolic acid)), have been utilized to develop novel biodegradable tissue adhesives. Incorporated biodegradable polymers are degraded in vivo with time under specific conditions, leading to the destruction of the structure and the further degradation of tissue adhesives. In this review, we first summarize the strategies of utilizing biodegradable polymers to develop tissue adhesives. Furthermore, we provide a symmetric overview of the biodegradable polymers used for tissue adhesives, with a specific focus on the degradability and applications of these tissue adhesives. Additionally, the challenges and perspectives of biodegradable polymer-based tissue adhesives are discussed. We expect that this review can provide new inspirations for the design of novel biodegradable tissue adhesives for biomedical applications.


Asunto(s)
Materiales Biocompatibles , Adhesivos Tisulares , Adhesivos Tisulares/química , Humanos , Animales , Materiales Biocompatibles/química , Polímeros/química , Plásticos Biodegradables/química , Quitosano/química
4.
J Imaging Inform Med ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38491235

RESUMEN

Radiofrequency ablation (RFA) is the treatment of choice for atrial fibrillation (AF). Additionally, the utilization of 3D printing for cardiac models offers an in-depth insight into cardiac anatomy and cardiovascular diseases. The study aims to evaluate the clinical utility and outcomes of RFA following in vitro visualization of the left atrium (LA) and pulmonary vein (PV) structures via 3D printing (3DP). Between November 2017 and April 2021, patients who underwent RFA at the First Affiliated Hospital of Xinxiang Medical University were consecutively enrolled and randomly allocated into two groups: the 3DP group and the control group, in a 1:1 ratio. Computed tomography angiography (CTA) was employed to capture the morphology and diameter of the LA and PV, which facilitated the construction of a 3D entity model. Additionally, surgical procedures were simulated using the 3D model. Parameters such as the duration of the procedure, complications, and rates of RFA recurrence were meticulously documented. Statistical analysis was performed using the t-test or Mann-Whitney U test to evaluate the differences between the groups, with a P-value of less than 0.05 considered statistically significant. In this study, a total of 122 patients were included, with 53 allocated to the 3DP group and 69 to the control group. The analysis of the morphological measurements of the LA and PV taken from the workstation or direct entity measurement showed no significant difference between the two groups (P > 0.05). However, patients in the 3DP group experienced significantly shorter RFA times (97.03 ± 28.39 compared to 120.51 ± 44.76 min, t = 3.05, P = 0.003), reduced duration of radiation exposure (2.55 [interquartile range 2.01, 3.24] versus 3.20 [2.28, 3.91] min, Z = 3.23, P < 0.001), and shorter modeling times (7.68 ± 1.03 compared to 8.89 ± 1.45 min, t = 5.38, P < 0.001). 3DP technology has the potential to enhance standard RFA practices by reducing the time required for intraoperative interventions and exposure to radiation.

5.
Acta Radiol ; 64(3): 1018-1027, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35722668

RESUMEN

BACKGROUND: Pulmonary vein (PV) data are commonly measured on multiplanar image reformation (MPR) images and volume rendering (VR) images. PURPOSE: To compared and analyze the advantages and disadvantages of PV data based on VR images and MPR images. MATERIAL AND METHODS: A total of 94 patients with atrial fibrillation (AF) with imaging data were included in the study. The respective image postprocessing time and the three surgical interventionists' preferences for the two images were recorded. A paired t-test or chi-square test was used to compare their difference, and P < 0.05 was considered statistically significant. RESULTS: There was no statistically significant difference between the data values including the maximal and minimal ostial diameters of the left superior PV (LSPV), the left inferior PV (LIPV), the right superior PV (RSPV), and the right inferior PV (RIPV) obtained by VR and MPR images (P > 0.05). Yet, the mean postprocessing time of VR images (15.10 ± 3.05 min) was shorter compared to MPR images (16.54 ± 2.60 min) (t = 22.84, P < 0.05). All three surgical interventionists preferred VR images (accounted for 85.1%, 86.2%, and 84.0%, respectively), and there was no statistical difference in the degree of image preference among the three (chi-square = 0.596, P = 0.963). CONCLUSION: PV data measurement could be performed on both VR and MRP images; however, the data on VR images were more intuitive and more accessible for interventional surgeons.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos
6.
Front Mol Biosci ; 9: 730213, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35720122

RESUMEN

Background: Target therapies play more and more important roles in gastrointestinal stromal tumors (GISTs) and melanoma with the advancement of clinical drugs that overcome the resistance caused by gene mutations. c-KIT gene mutations account for a large portion of GIST patients, which are known to be sensitive or resistant to tyrosine kinase inhibitors. However, the role rare mutations play in drug efficacy and progression-free duration remains elusive. Methods: Two rare mutations were identified using Sanger sequencing from the GIST and melanoma cases. Cell experiments were further carried out to demonstrate their role in the imatinib resistance. Results: c-KIT c.1926delA p.K642S*FS mutation in primary and recurrent GIST patients and c-KIT c.1936T>G p.Y646D point mutation in melanoma patients in exon 13 were first demonstrated to be novel targets resistant to imatinib agent. Conclusion: c-KIT mutations c.1926delA and c.1936T>G in exon 13 are clinically significant targets that exhibit resistance to imatinib. This study provides guidance to GIST and melanoma treatments.

7.
BMC Med Educ ; 18(1): 183, 2018 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-30071844

RESUMEN

BACKGROUND: There are two parts included in traditional imaging diagnosis teaching: theoretical lessons and experimental lessons. Most of the time, the experimental lesson is a review of the theoretical lesson. The teacher is the centre of the course and students are passive learners. Thus, in this study we included the patient problem of the imaging centre in our imaging diagnosis education. The traditional theoretical lessen was used to discuss prior knowledge, the discussion and analysis of patient problems was arranged under class, and the experimental lesson was used to synthesize and test the newly acquired information. The aim of this study is to determine whether or not integration of problem- and lecture-based learning teaching modes in imaging diagnosis education was associated with a good teaching effect. Forty-six of sixty students (76.7%) like integrated problem- and lecture-based learning teaching mode and 53 of 60 students (88.3%) think that integrated problem- and lecture-based learning teaching mode can make their ability of self-study be improved. METHODS: Sixty students participated in a prospective study with a two-phase cross-over design. All of the students were divided into 2 groups of 30 each. In the first term, the first group participated in an integration of the problem- and lecture-based learning teaching mode, whereas students in the second group underwent the lecture-based learning teaching mode alone. During the second term, the teaching modes were exchanged between the two groups. A close-exam and survey were used to evaluate the teaching effect, and the data were analysed means of analysis of variance with a two-phase cross-over design and a χ2 test with a 2-tailed α of 0.05. RESULTS: There was a statistically significant difference in the test scores between the integration of the problem- and lecture-based learning teaching mode and the lecture-based learning teaching mode alone (P < 0.05). The integration of problem- and lecture-based learning teaching mode was well-appraised. CONCLUSION: Integration of the problem- and lecture-based learning teaching modes in teaching imaging diagnosis education resulted in a good teaching effect.


Asunto(s)
Diagnóstico por Imagen , Aprendizaje Basado en Problemas , Enseñanza , Estudios Cruzados , Evaluación Educacional , Humanos , Aprendizaje , Proyectos Piloto , Estudios Prospectivos , Encuestas y Cuestionarios
8.
Exp Ther Med ; 10(5): 1871-1876, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26640564

RESUMEN

The aim of the present study was to compare the accuracy of 64-multi-slice spiral computed tomography (64-MSCT) and 320-MSCT in the display of coronary artery stents and diagnosis of in-stent restenosis. The data collected from the 64- and 320-MSCT coronary angiography of 93 patients following coronary artery stent implantation were retrospectively analyzed. The 64-MSCT group comprised 30 cases with 57 stents and the 320-MSCT group comprised 63 cases with 93 stents. The image quality, heart rate of the patients and the radiation effective dose (ED) they were subjected to, were compared. Furthermore, the diagnostic abilities of 64-and 320-MSCT coronary angiography for in-stent restenosis were evaluated using invasive coronary angiography results as the gold standards. Statistically significant differences were observed in the heart rate and ED of the patients from the two groups (P<0.05), but no significant difference was identified in the accuracy index (P>0.05). The sensitivity, specificity, positive and negative predictive value and accuracy of the 64-MSCT group were found to be 100% (7/7), 93.94% (31/33), 77.78% (7/9), 100% (31/31) and 95% (38/40), respectively, and those in the 320-MSCT group were found to be 100% (16/16), 95.89% (70/73), 84.21% (16/19), 100% (70/70) and 96.63% (86/89), respectively. The present findings suggest that both 64-MSCT and 320-MSCT can be used for follow-up and curative effect evaluation following coronary stent implantation; however, 320-MSCT has fewer requirements of the patients' heart rate and uses a lower radiation dose.

9.
Oncol Lett ; 9(2): 661-666, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25621034

RESUMEN

The present study retrospectively examined 24 cases of pathologically confirmed synovial sarcoma and analyzed the clinical presentation and imaging findings in order to explore the imaging features of synovial sarcoma. The majority of the lesions were large (>5 cm; 88%), rounded or lobulated, relatively well-defined tumor masses in the extremities near the joints or deeply located. On computed tomography (CT) scans, the lesions demonstrated intensity signals similar to those of muscle. Six cases exhibited punctate calcification in the periphery of the tumor. On T1-weighted images, the largest lesions of >5 cm, were usually heterogeneous, with a signal intensity similar to or slightly higher than that of muscle. On T2-weighted images, heterogeneous high-intensity or slightly high-intensity signals were observed, with 12 cases exhibiting a high signal consistent with hemorrhage and 12 presenting signals that indicated internal septations. Contrast-enhanced scanning revealed heterogeneous enhancement in the majority of the lesions and no enhancement in areas of cystic necrosis or internal septations. Synovial sarcoma has specific imaging features, and comprehensive analysis of CT and magnetic resonance imaging can improve the accuracy of the pre-operative diagnosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA