Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dentomaxillofac Radiol ; 41(1): 30-6, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22184626

RESUMEN

OBJECTIVES: The purpose of the study was to calculate the effective dose delivered to the patient undergoing cone beam (CB) CT of the jaws and maxillofacial complex using the i-CAT Next Generation CBCT scanner (Imaging Sciences International, Hatfield, PA). METHODS: A RANDO® phantom (The Phantom Laboratory, Salem, NY) containing thermoluminence dosemeters were scanned 10 times for each of the 6 imaging protocols. Effective doses for each protocol were calculated using the 1990 and approved 2007 International Commission on Radiological Protection (ICRP) recommended tissue weighting factors (E1990, E2007). RESULTS: The effective dose for E1990 and E2007, respectively, were: full field of view (FOV) of the head, 47 µSv and 78 µSv; 13 cm scan of the jaws, 44 µSv and 77 µSv; 6 cm standard mandible, 35 µSv and 58 µSv; 6 cm high resolution mandible, 69 µSv and 113 µSv; 6 cm standard maxilla, 18 µSv and 32 µSv; and 6 cm high resolution maxilla, 35 µSv and 60 µSv. CONCLUSIONS: Using the new generation of CBCT scanner, the effective dose is lower than the original generation machine for a similar FOV using the ICRP 2007 tissue weighting factors.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/efectos de la radiación , Maxilar/efectos de la radiación , Dosis de Radiación , Encéfalo/efectos de la radiación , Tomografía Computarizada de Haz Cónico/instrumentación , Huesos Faciales/diagnóstico por imagen , Huesos Faciales/efectos de la radiación , Humanos , Mandíbula/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Fantasmas de Imagen , Efectividad Biológica Relativa , Base del Cráneo/efectos de la radiación , Glándula Submandibular/efectos de la radiación , Dosimetría Termoluminiscente/instrumentación , Glándula Tiroides/efectos de la radiación
2.
Dentomaxillofac Radiol ; 38(3): 127-33, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19225082

RESUMEN

OBJECTIVES: To evaluate an evolving radiation protection dental postgraduate course run in Wales between 2003 and 2007. METHODS: We compared three standardized course series. Course content was enhanced in 2006 to target areas of weakness. In 2007, a single best answer multiple choice questionnaire instrument superseded a true/false format. Practitioners' performance was studied pre- and immediately post-training. 900 participants completed identical pre- and post-course validated multiple choice questionnaires. 809 (90%) paired morning-afternoon records, including those of 52 dental care professionals (DCPs), were analysed. RESULTS: Mean (standard error) pre- and post-course percentage scores for the three courses were 33.8 (0.9), 35.4 (1.4), 34.6 (1.0) and 63.6 (0.9), 59.0 (1.4), 69.5 (0.9). Pre-training, only 2.4%, 3.1% and 4.9% of participants achieved the pass mark compared to 57.7%, 48.4% and 65.9% post-training, indicating a rather greater pass rate and gain in the most recent series than earlier ones. In recent series, older more experienced candidates scored slightly higher; however, their gain from pre- to post-training was slightly less. CONCLUSIONS: Baseline levels of radiation protection knowledge remained very low but attending an approved course improved this considerably. Targeting areas of weaknesses produced higher scores. Current radiation protection courses may not be optimal for DCPs.


Asunto(s)
Curriculum , Educación Continua en Odontología , Física Sanitaria/educación , Protección Radiológica , Salud Radiológica/educación , Odontología Comunitaria/educación , Comprensión , Auxiliares Dentales/educación , Servicio Odontológico Hospitalario , Odontólogos , Educación Continua , Evaluación Educacional/métodos , Odontología General/educación , Humanos , Evaluación de Programas y Proyectos de Salud , Encuestas y Cuestionarios , Gales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA