Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Sci Rep ; 13(1): 9366, 2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37296200

RESUMEN

Smoothing orientation data is a fundamental task in different fields of research. Different methods of smoothing time series in quaternion algebras have been described in the literature, but their application is still an open point. This paper develops a smoothing approach for smoothing quaternion time series to obtain good performance in classification problems. Starting from an existing method which involves an angular velocity transformation of unit quaternion time series, a new method which employ the logarithm function to transform the quaternion time series to a real three-dimensional time series is proposed. Empirical evidences achieved on real data set and artificially noisy data sets confirm the effectiveness of the proposed method compared with the classical approach based on angular velocity transformation. The R functions developed for this paper will be provided in a Github repository.


Asunto(s)
Algoritmos , Factores de Tiempo , Movimiento (Física)
2.
Stat Med ; 42(4): 433-456, 2023 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-36509423

RESUMEN

Recent approaches in gait analysis involve the use of wearable motion sensors to extract spatio-temporal parameters that characterize multiple aspects of an individual's gait. In particular, the medical community could largely benefit from this type of devices as they could provide the clinicians with a valuable tool for assessing gait impairment. Motion sensor data are however complex and there is an urgent unmet need to develop sound statistical methods for analyzing such data and extracting clinically relevant information. In this article, we measure gait by following the hip rotation over time and the resulting statistical unit is a time series of unit quaternions. We explore the possibility to form groups of patients with similar walking impairment by taking into account their walking data and their global decease severity with semi-supervised clustering. We generalize a compromise-based method named hclustcompro to unit quaternion time series by combining it with the proper dissimilarity quaternion dynamic time warping. We apply this method on patients diagnosed with multiple sclerosis to form groups of patients with similar walking deficiencies while accounting for the clinical assessment of their overall disability. We also compare the compromise-based clustering approach with the method mergeTrees that falls into a sub-class of ensemble clustering named collaborative clustering. The results provide a first proof of both the interest of using wearable motion sensors for assessing gait impairment and the use of prior knowledge to guide the clustering process. It also demonstrates that compromise-based clustering is a more appropriate approach in this context.


Asunto(s)
Análisis de la Marcha , Esclerosis Múltiple , Humanos , Factores de Tiempo , Marcha , Caminata
3.
Sensors (Basel) ; 22(9)2022 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-35591247

RESUMEN

Solutions to assess walking deficiencies are widespread and largely used in healthcare. Wearable sensors are particularly appealing, as they offer the possibility to monitor gait in everyday life, outside a facility in which the context of evaluation biases the measure. While some wearable sensors are powerful enough to integrate complex walking activity recognition models, non-invasive lightweight sensors do not always have the computing or memory capacity to run them. In this paper, we propose a walking activity recognition model that offers a viable solution to this problem for any wearable sensors that measure rotational motion of body parts. Specifically, the model was trained and tuned using data collected by a motion sensor in the form of a unit quaternion time series recording the hip rotation over time. This time series was then transformed into a real-valued time series of geodesic distances between consecutive quaternions. Moving average and moving standard deviation versions of this time series were fed to standard machine learning classification algorithms. To compare the different models, we used metrics to assess classification performance (precision and accuracy) while maintaining the detection prevalence at the level of the prevalence of walking activities in the data, as well as metrics to assess change point detection capability and computation time. Our results suggest that the walking activity recognition model with a decision tree classifier yields the best compromise in terms of precision and computation time. The sensor that was used had purposely low computing and memory capacity so that reported performances can be thought of as the lower bounds of what can be achieved. Walking activity recognition is performed online, i.e., on-the-fly, which further extends the range of applicability of our model to sensors with very low memory capacity.


Asunto(s)
Caminata , Dispositivos Electrónicos Vestibles , Marcha , Rotación , Factores de Tiempo
4.
Sci Rep ; 7(1): 9257, 2017 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-28835615

RESUMEN

Innovative approaches combining regulatory networks (RN) and genomic data are needed to extract biological information for a better understanding of diseases, such as cancer, by improving the identification of entities and thereby leading to potential new therapeutic avenues. In this study, we confronted an automatically generated RN with gene expression profiles (GEP) from a cohort of multiple myeloma (MM) patients and normal individuals using global reasoning on the RN causality to identify key-nodes. We modeled each patient by his or her GEP, the RN and the possible automatically detected repairs needed to establish a coherent flow of the information that explains the logic of the GEP. These repairs could represent cancer mutations leading to GEP variability. With this reasoning, unmeasured protein states can be inferred, and we can simulate the impact of a protein perturbation on the RN behavior to identify therapeutic targets. We showed that JUN/FOS and FOXM1 activities are altered in almost all MM patients and identified two survival markers for MM patients. Our results suggest that JUN/FOS-activation has a strong impact on the RN in view of the whole GEP, whereas FOXM1-activation could be an interesting way to perturb an MM subgroup identified by our method.


Asunto(s)
Reprogramación Celular/genética , Mieloma Múltiple/genética , Mieloma Múltiple/metabolismo , Factores de Transcripción/metabolismo , Algoritmos , Biología Computacional/métodos , Proteína Forkhead Box M1/metabolismo , Perfilación de la Expresión Génica , Regulación Neoplásica de la Expresión Génica , Humanos , Proteínas Quinasas JNK Activadas por Mitógenos/metabolismo , Modelos Biológicos , Mieloma Múltiple/mortalidad , Mieloma Múltiple/patología , Proteínas Oncogénicas v-fos/metabolismo , Reproducibilidad de los Resultados , Programas Informáticos , Transcriptoma
5.
J Clin Microbiol ; 50(4): 1240-4, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22301023

RESUMEN

The triage of women with high-risk (HR) human papillomavirus (HPV)-positive smears for atypical squamous cells of undetermined significance (ASC-US) to colposcopy is now an integrated option in clinical guidelines. The performance of cobas 4800 HPV and that of Hybrid Capture 2 (HC2) for HR HPV DNA detection in cervical samples in PreservCyt were compared in 396 women referred to colposcopy for ASC-US. Of these, 316 did not have cervical intraepithelial neoplasia (CIN), 47 had CIN1, 29 had CIN2 or CIN3 (CIN2+), and 4 had CIN of unknown grade. HR HPV was detected in 129 (32.6%) and 149 (37.6%) samples with HC2 and cobas 4800 HPV, respectively (P = 0.15). The clinical sensitivities and specificities for detecting CIN2+ were 89.7% (95% confidence interval [CI], 72.8 to 97.2%) and 66.7% (95% CI, 61.7 to 71.3%) with cobas 4800 HPV and 93.1% (95% CI, 77.0 to 99.2%) and 72.2% (95% CI 67.4 to 76.5%) with HC2. The performance of cobas 4800 HPV was similar to that of HC2 for identifying women with ASC-US who would benefit the most from colposcopy.


Asunto(s)
Epitelio/patología , Técnicas de Diagnóstico Molecular , Infecciones por Papillomavirus/diagnóstico , Displasia del Cuello del Útero/diagnóstico , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Anciano , Colposcopía , ADN Viral , Femenino , Genotipo , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Humanos , Persona de Mediana Edad , Infecciones por Papillomavirus/patología , Infecciones por Papillomavirus/virología , Sensibilidad y Especificidad , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/virología , Adulto Joven , Displasia del Cuello del Útero/patología , Displasia del Cuello del Útero/virología
6.
Gynecol Oncol ; 124(2): 286-91, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22062546

RESUMEN

OBJECTIVES: We compared the screening performance of conventional Pap cytology and two human papillomavirus (HPV) DNA assays, the original Hybrid Capture 2 (HC2) and an expanded version that tests for 4 additional HPV types (HC2+4; Qiagen Corporation), in the detection of cervical neoplasia among unscreened women in a primary care setting in a suburb of Kinshasa, Democratic Republic of the Congo. METHODS: All women 30 years or older residing in the area were invited to participate, and 1528 were evaluated by Pap cytology and the two HPV assays, conducted at a European and US reference laboratory, respectively, followed by colposcopy. Cervical biopsies were obtained from all women with abnormal colposcopy and from 290 randomly chosen women with normal colposcopy (to correct for verification bias). RESULTS: Using a relative light unit of 1 as the cutoff for positivity, 169 and 168 (11%) women tested positive using HC2 and HC2+4, respectively. HC2 and HC2+4 were in agreement in 98.6% of cases (Kappa=0.94; 95% confidence interval: 0.91-0.96). Both assays were sensitive (~83%) and specific (~91%) for the detection of cervical intraepithelial neoplasia-2 or worse disease. Irrespective of the cutoff point used to define positivity, Pap cytology was both less sensitive and more specific than HC2 or HC2+4. For instance, cytology was 63% sensitive and 97% specific when a cutoff point of low-grade squamous intraepithelial lesions or worse was used. CONCLUSIONS: Among unscreened women, HC2 and HC2+4 had similar screening accuracy for cervical neoplasia, and both were more sensitive but less specific than Pap cytology.


Asunto(s)
Papillomaviridae/aislamiento & purificación , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/virología , Adulto , Biopsia , Colposcopía , Estudios Transversales , República Democrática del Congo , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Persona de Mediana Edad , Papillomaviridae/genética , Atención Primaria de Salud , Displasia del Cuello del Útero/patología , Displasia del Cuello del Útero/virología
7.
J Clin Microbiol ; 49(1): 48-53, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21084508

RESUMEN

Up to 20% of women having a cytology smear showing atypical squamous cells of undetermined significance (ASC-US) and infected with high-risk human papillomavirus (HR HPV) have high-grade cervical intraepithelial neoplasia (CIN 2/3). Results obtained with the Amplicor HPV and Hybrid Capture 2 (HC-2) assays for HR HPV DNA detection in women referred to colposcopy for an ASC-US smear were compared. Cervical samples in PreservCyt were tested for the presence of 13 HR HPV types with HC-2, with Amplicor at three cutoffs for positivity (0.2, 1.0, and 1.5 optical density units), and for 36 genotypes with the Linear Array (LA). Of 396 eligible women, 316 did not have CIN, 47 had CIN 1, 29 had CIN 2/3, and 4 had CIN of unknown grade. HR HPV was detected in 129 (32.6%) and 164 (41.4%) samples with HC-2 and Amplicor HPV (cutoff, 0.2), respectively (P = 0.01). Overall, 112 specimens were positive and 215 were negative with the HC-2 and Amplicor HPV assays (agreement of 82.6%; 95% confidence interval [CI], 78.5 to 86.0). The clinical sensitivity and specificity of Amplicor HPV at cutoffs of 0.2, 1.0 and 1.5 and of HC-2 for detection of CIN 2/3 were 89.7% (95% CI, 72.8 to 97.2) and 62.5% (95% CI, 57.5 to 52.4), 89.7% (95% CI, 72.8 to 97.2) and 64.5% (95% CI, 59.4 to 69.2), 89.7% (95% CI, 72.8 to 97.2) and 64.7% (95% CI, 59.7 to 69.5), and 93.1% (95% CI, 77.0 to 99.2) and 72.2% (95% CI, 67.4 to 76.5), respectively. Both HR HPV detection tests identified women with ASC-US who would benefit the most from colposcopy. Women with persistent HR HPV infection need further investigation despite a first normal colposcopy.


Asunto(s)
ADN Viral/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología , Virología/métodos , Adulto , Anciano , Cuello del Útero/patología , Cuello del Útero/virología , Femenino , Humanos , Persona de Mediana Edad , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad
8.
Psychooncology ; 19(12): 1340-7, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20878857

RESUMEN

OBJECTIVE: This pilot study aimed to provide supportive evidence for the acceptability and usefulness of the Meaning-Making intervention (MMi) in patients newly diagnosed with Stage III or IV ovarian cancer, and to provide estimates of parameters needed to design a full-scale study. METHODS: A randomized controlled trial with 24 patients (12 experimental and 12 control) was conducted. Existential well-being (primary outcome), overall quality of life, distress, anxiety, depression and self-efficacy were measured. RESULTS: Compared to the control group, patients in the experimental group had a better sense of meaning in life at one and three months post-intervention. CONCLUSION: The MMi seems a promising intervention for advanced cancer patients, and a full randomized controlled trial is warranted to further investigate its efficacy.


Asunto(s)
Adaptación Psicológica , Neoplasias Ováricas/psicología , Calidad de Vida , Ansiedad/psicología , Depresión/psicología , Femenino , Humanos , Proyectos Piloto , Psicometría , Psicoterapia Breve , Autoeficacia , Factores Socioeconómicos , Estrés Psicológico/psicología , Estrés Psicológico/terapia , Encuestas y Cuestionarios , Resultado del Tratamiento
9.
Lancet Oncol ; 11(7): 646-52, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20537946

RESUMEN

BACKGROUND: Currently, all patients with vulvar cancer with a positive sentinel node undergo inguinofemoral lymphadenectomy, irrespective of the size of sentinel-node metastases. Our study aimed to assess the association between size of sentinel-node metastasis and risk of metastases in non-sentinel nodes, and risk of disease-specific survival in early stage vulvar cancer. METHODS: In the GROningen INternational Study on Sentinel nodes in Vulvar cancer (GROINSS-V), sentinel-node detection was done in patients with T1-T2 (<4 cm) squamous-cell vulvar cancer, followed by inguinofemoral lymphadenectomy if metastatic disease was identified in the sentinel node, either by routine examination or pathological ultrastaging. For the present study, sentinel nodes were independently reviewed by two pathologists. FINDINGS: Metastatic disease was identified in one or more sentinel nodes in 135 (33%) of 403 patients, and 115 (85%) of these patients had inguinofemoral lymphadenectomy. The risk of non-sentinel-node metastases was higher when the sentinel node was found to be positive with routine pathology than with ultrastaging (23 of 85 groins vs three of 56 groins, p=0.001). For this study, 723 sentinel nodes in 260 patients (2.8 sentinel nodes per patient) were reviewed. The proportion of patients with non-sentinel-node metastases increased with size of sentinel-node metastasis: one of 24 patients with individual tumour cells had a non-sentinel-node metastasis; two of 19 with metastases 2 mm or smaller; two of 15 with metastases larger than 2 mm to 5 mm; and ten of 21 with metastases larger than 5 mm. Disease-specific survival for patients with sentinel-node metastases larger than 2 mm was lower than for those with sentinel-node metastases 2 mm or smaller (69.5%vs 94.4%, p=0.001). INTERPRETATION: Our data show that the risk of non-sentinel-node metastases increases with size of sentinel-node metastasis. No size cutoff seems to exist below which chances of non-sentinel-node metastases are close to zero. Therefore, all patients with sentinel-node metastases should have additional groin treatment. The prognosis for patients with sentinel-node metastasis larger than 2 mm is poor, and novel treatment regimens should be explored for these patients.


Asunto(s)
Biopsia del Ganglio Linfático Centinela , Neoplasias de la Vulva/patología , Anciano , Supervivencia sin Enfermedad , Femenino , Ingle , Humanos , Metástasis Linfática , Recurrencia Local de Neoplasia/prevención & control , Pronóstico , Modelos de Riesgos Proporcionales , Prevención Secundaria , Análisis de Supervivencia , Neoplasias de la Vulva/cirugía
10.
Anticancer Res ; 29(5): 1591-3, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19443371

RESUMEN

BACKGROUND: The development of a mass in a surgical scar poses a diagnostic dilemma due to similarities in appearance to hernias, abscesses, hematomas or desmoid tumors. Scar endometriosis is uncommon and malignant change within this ectopic tissue is rare. CASE REPORT: The case of a 55-year-old woman with an isolated clear cell adenocarcinoma in an area of scar endometriosis more than 17 years after a cesarean section is presented. Initially, this tumor was thought to be a chronic abscess, but was finally diagnosed as clear cell carcinoma. This case highlights the difficulties in preoperative diagnosis as well as the poor prognosis of these tumors. CONCLUSION: Accurate diagnosis of a lump within a scar is important to define the prognosis and treatment. Further data are needed for the management of this pathology.


Asunto(s)
Neoplasias Abdominales/diagnóstico , Adenocarcinoma/diagnóstico , Neoplasias Abdominales/cirugía , Adenocarcinoma/cirugía , Resultado Fatal , Femenino , Humanos , Persona de Mediana Edad
11.
Gynecol Obstet Invest ; 67(3): 173-7, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19088481

RESUMEN

OBJECTIVES: Clinical and pathological significance of stage IIIC endometrial cancer is unclear. Our study was designed to determine the risk of recurrence among patients with stage IIIC endometrial cancer according to different pathological findings. METHODS: We retrospectively reviewed all patients with FIGO IIIC endometrial carcinoma (n = 48) treated in our institution between 1996 and 2005. Patients without comprehensive surgical staging were excluded. Patients were classified into two groups: with adnexae and/or uterine serosal metastasis (group A, n = 18) and without metastasis (group B, n = 20). Cox proportional hazards model was used for multiple regression analysis. RESULTS: Mean age was 64 years (range 46-90). Eighteen patients received adjuvant chemotherapy and pelvic radiotherapy, 17 received pelvic radiotherapy alone, and 11 received chemotherapy or hormonotherapy. At a median follow-up of 26.7 months, 12 had recurrence of the disease. Serosal and/or adnexal involvement was a negative independent prognostic factor for disease-free survival [relative risk = 3.75 (1.01-13.9); p = 0.04], whereas histological type, grade, depth of invasion and age at diagnosis had no influence. CONCLUSION: Patients with stage IIIC endometrial cancer and metastasis to adnexae and/or serosa have a higher risk of recurrence than those with node metastasis alone. Optimal adjuvant therapy for these groups remains unclear.


Asunto(s)
Neoplasias Endometriales/patología , Recurrencia Local de Neoplasia , Neoplasias Ováricas/secundario , Peritoneo/patología , Anciano , Anciano de 80 o más Años , Quimioterapia Adyuvante , Femenino , Humanos , Persona de Mediana Edad , Invasividad Neoplásica , Estadificación de Neoplasias , Estudios Retrospectivos , Factores de Riesgo
12.
J Clin Oncol ; 26(6): 884-9, 2008 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-18281661

RESUMEN

PURPOSE: To investigate the safety and clinical utility of the sentinel node procedure in early-stage vulvar cancer patients. PATIENTS AND METHODS: A multicenter observational study on sentinel node detection using radioactive tracer and blue dye was performed in patients with T1/2 (< 4 cm) squamous cell cancer of the vulva. When the sentinel node was found to be negative at pathologic ultrastaging, inguinofemoral lymphadenectomy was omitted, and the patient was observed with follow-up for 2 years at intervals of every 2 months. Stopping rules were defined for the occurrence of groin recurrences. RESULTS: From March 2000 until June 2006, a sentinel node procedure was performed in 623 groins of 403 assessable patients. In 259 patients with unifocal vulvar disease and a negative sentinel node (median follow-up time, 35 months), six groin recurrences were diagnosed (2.3%; 95% CI, 0.6% to 5%), and 3-year survival rate was 97% (95% CI, 91% to 99%). Short-term morbidity was decreased in patients after sentinel node dissection only when compared with patients with a positive sentinel node who underwent inguinofemoral lymphadenectomy (wound breakdown in groin: 11.7% v 34.0%, respectively; P < .0001; and cellulitis: 4.5% v 21.3%, respectively; P < .0001). Long-term morbidity also was less frequently observed after removal of only the sentinel node compared with sentinel node removal and inguinofemoral lymphadenectomy (recurrent erysipelas: 0.4% v 16.2%, respectively; P < .0001; and lymphedema of the legs: 1.9% v 25.2%, respectively; P < .0001). CONCLUSION: In early-stage vulvar cancer patients with a negative sentinel node, the groin recurrence rate is low, survival is excellent, and treatment-related morbidity is minimal. We suggest that sentinel node dissection, performed by a quality-controlled multidisciplinary team, should be part of the standard treatment in selected patients with early-stage vulvar cancer.


Asunto(s)
Carcinoma de Células Escamosas/secundario , Carcinoma de Células Escamosas/cirugía , Recurrencia Local de Neoplasia/prevención & control , Biopsia del Ganglio Linfático Centinela , Neoplasias de la Vulva/patología , Neoplasias de la Vulva/cirugía , Adulto , Anciano , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Ingle , Humanos , Escisión del Ganglio Linfático , Metástasis Linfática , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos , Análisis de Supervivencia , Resultado del Tratamiento
13.
Fundam Clin Pharmacol ; 21(4): 387-96, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17635177

RESUMEN

Haemorheological changes have been described in hypertension as well as in diabetes mellitus. Antihypertensive treatment improves rheology in hypertensive patients. The aim of this study was to describe the haemorheological profile and its impact on shear stress in hypertensive type 2 diabetes mellitus patients (HT + DM) and to investigate the effect of antihypertensive therapy on blood rheology using a double-blind randomized protocol, comparing the calcium antagonist amlodipine with the angiotensin-converting enzyme (ACE) inhibitor enalapril. A total of 144 patients with hypertension and type 2 diabetes (64 of transversal study and 80 of randomized clinical trial) were compared with 92 controls belonging to a transversal study. Secondarily, in a separate analysis, therapeutic effects of calcium antagonist amlodipine and ACE inhibitor enalapril were compared in a longitudinal, randomized trial in the patients. We assessed whole-blood viscosity, plasma viscosity, partial and total disaggregation times, haematocrit and fibrinogen. Radial artery systolic flow velocity was measured by pulsed Doppler. Shear stress was calculated as the product of flow velocity x whole-blood viscosity. Compared with controls, patients had significantly higher whole-blood viscosity for all shear rates (P < 0.001) as well as higher arterial diameter and systolic blood flow velocity (2.8 +/- 0.3 vs. 2.6 +/- 0.3 mm, P < 0.001; and 50.8 +/- 11.6 vs. 45.6 +/- 9.8 cm/s, P = 0.01, respectively). Whole-blood viscosity at shear rate gamma = 128/s tended to increase with amlodipine (+1.13%) and decrease with enalapril (-2.47%) (P = 0.028 for inter-group difference). In hypertensive diabetic patients, hyperviscosity contributes to increased shear stress. Haemorheological disturbances in these patients are not significantly influenced by blood pressure lowering with antihypertensive therapy by ACE inhibitor enalapril or calcium antagonist amlodipine. Other factors potentially contributing to rheology and arterial changes may be more critical in HT + DM patients and need further investigation.


Asunto(s)
Antihipertensivos/uso terapéutico , Diabetes Mellitus/sangre , Hipertensión/sangre , Amlodipino/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Velocidad del Flujo Sanguíneo , Presión Sanguínea/efectos de los fármacos , Viscosidad Sanguínea , Bloqueadores de los Canales de Calcio/uso terapéutico , Diabetes Mellitus/tratamiento farmacológico , Método Doble Ciego , Enalapril/uso terapéutico , Femenino , Hemorreología , Humanos , Hipertensión/tratamiento farmacológico , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estrés Mecánico
14.
J Med Virol ; 78(6): 814-9, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16628584

RESUMEN

Human papillomavirus (HPV) infection is associated with high-grade vulvar intraepithelial neoplasia (VIN-3). The prevalence of anogenital HPV infection in women with previously treated VIN-3 has not been documented yet. This cross-sectional study compared high-risk HPV DNA detection rates in women with past (n = 30) and current (n = 22) VIN-3 to those without current or past VIN (n = 86). HPV DNA was detected in vulvar and cervical samples with Hybrid Capture 2 (HC-2). Smoking was associated in multivariate analysis with current VIN-3 (odds ratio (OR) 8.3, 95% confidence interval (CI) 2.0-8.2) and any VIN-3 history (OR 6.5, 95% CI 2.5-16.5). High-risk HPV DNA was found on the vulva of 64%, 33%, and 20% of women with current VIN-3, past VIN-3, and without previous or current VIN, respectively. After controlling for age and smoking, high-risk HPV vulvar infection was associated with cervical high-risk HPV infection (OR 8.6, 95% CI 2.8-26.5; P = 0.001). After controlling for age, HPV infection was more often multifocal in women with current VIN-3 compared to women with previous but no current VIN-3 lesion (OR 17.6, 95% CI 1.4-227.2). Multifocal vulvar HPV infection was detected in women with previous or active VIN-3. Longitudinal studies are required to determine if the multifocality of HPV infection on the vulva could explain the high recurrence rate of VIN-3.


Asunto(s)
Papillomaviridae/aislamiento & purificación , Infecciones por Papillomavirus/diagnóstico , Neoplasias de la Vulva/virología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento , Cuello del Útero/virología , Estudios Transversales , ADN Viral/aislamiento & purificación , Femenino , Humanos , Persona de Mediana Edad , Oportunidad Relativa , Infecciones por Papillomavirus/complicaciones , Infecciones por Papillomavirus/virología , Vulva/virología
15.
Int J Cancer ; 119(6): 1389-95, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16619217

RESUMEN

We evaluated the feasibility and performance of visual inspection with acetic acid (VIA) and Lugol's iodine (VILI) for cervical cancer screening in a primary health-care setting in Kinshasa, Congo. Women (1,528) aged > or =30 years were screened independently by nurses and physicians by VIA and VILI and Pap cytology. Biopsy samples were obtained from women with abnormal colposcopies and from 290 randomly chosen women with normal colposcopy. Cytological and histological examinations were performed in Lyon and Montreal, respectively. The prevalence of cervical intraepithelial neoplasia (CIN) of grades 1, 2 and 3 was 4.5, 1.3 and 4%, respectively. Using biopsy as the reference, the sensitivity, specificity and negative predictive value (NPV) for > or =CIN 2 for VIA-nurse were 55.5% (95% CI: 34.7-76.2), 64.6% (95% CI: 62.0-67.1) and 96.8% (95% CI: 93.5-98.7), respectively. The corresponding values for VILI-nurse were 44.0% (95% CI: 24.2-63.8), 74.6% (95% CI: 72.3-76.9) and 96.7% (95% CI: 93.7-98.6). The equivalent parameters for physicians were 71.1% (95% CI: 46.7-95.5), 71.3% (95% CI: 68.9-73.6) and 98.6% (95% CI: 96.0-99.7) for VIA and 68.3% (95% CI: 42.5-94.0), 76.2% (95% CI: 74.0-78.4) and 97.2% (95% CI: 95.3-98.5) for VILI. The sensitivity of cytology ranged between 31 and 72%, depending on the abnormality threshold used to define positivity, with a corresponding specificity range of 94-99% and a NPV range of 97-99%. Our results show that VIA and VILI performed by nurses and physicians are slightly more sensitive but less specific than Pap cytology across multiple combinations of test and lesion thresholds. Given their lower cost and easy deployment, visual inspection methods merit further assessment as cervical cancer screening methods for low-resource countries.


Asunto(s)
Atención Primaria de Salud , Displasia del Cuello del Útero/diagnóstico , Neoplasias del Cuello Uterino/diagnóstico , Ácido Acético/farmacología , Adulto , Biopsia , Colposcopía , Estudios Transversales , República Democrática del Congo/epidemiología , Estudios de Factibilidad , Femenino , Humanos , Yoduros , Tamizaje Masivo , Persona de Mediana Edad , Examen Físico , Sensibilidad y Especificidad , Neoplasias del Cuello Uterino/epidemiología , Frotis Vaginal , Displasia del Cuello del Útero/epidemiología
16.
Gynecol Oncol ; 103(1): 75-80, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16530253

RESUMEN

OBJECTIVE: Evaluation of the sensitivity and specificity of fine needle aspiration of retroperitoneal masses and lymph nodes in gynecologic oncology. METHODS: Retrospective study of 101 punctures administered to 84 patients aged 23-86 years. The method's sensitivity and specificity were evaluated by clinical follow-up. RESULTS: A satisfactory sampling was obtained in 89.1% of punctures, and a cytological diagnosis was made in 88.1%. The size of the lymph nodes punctured was less than 14 mm in 46.5%. This test has a sensitivity of 87.5%, specificity of 88.9%, positive predictive value of 98%, negative predictive value of 53.3%, and accuracy of 87.7%. Four patients presented complications: pain (2), hematoma (1), and right ureteral perforation (1). CONCLUSIONS: The fine needle aspiration technique has excellent positive predictive value and low morbidity. As a method of visualization, CT-scan, in combination with lymphography, allows the location of small lesions and the definition of their internal structures. The weak negative predictive value of fine needle aspiration might be correctible by laparoscopy-directed biopsy, and its potential is clearly ensured by the development of techniques for locating sentinel lymph nodes.


Asunto(s)
Biopsia con Aguja Fina/métodos , Neoplasias de los Genitales Femeninos/patología , Ganglios Linfáticos/patología , Neoplasias Retroperitoneales/patología , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina/normas , Femenino , Humanos , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
17.
Gynecol Oncol ; 101(3): 445-9, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16386785

RESUMEN

OBJECTIVE: To evaluate the outcome of patients with recurrent vaginal endometrial cancer treated with high-dose-rate brachytherapy (HDRB) and external beam radiation therapy (EBRT). MATERIALS AND METHODS: The records of all patients diagnosed with endometrial cancer who had presented an isolated vaginal recurrence in our institution between January 1, 1997 and December 30, 2003 were reviewed. Twenty-two patients were identified; 18 (82%) received both EBRT and HDRB, and 4 (18%) received HDRB only. The median EBRT dose prescribed was 45 Gy (range: 44-50.4), and median HDRB was 26 Gy (range: 8-48). Recurrence-free intervals as well as disease-specific survival rates were noted. Complications were assessed in terms of early and late Radiation Therapy Oncology Group toxicity (grade 3 or worse) of the gastrointestinal tract, genitourinary tract and vagina. RESULTS: Median age at recurrence for the 22 patients was 72 years (range: 54-86). Median recurrence time was 20 months (range: 4-135). A complete response was achieved in 100% of patients. After a median follow-up of 32 months (range: 11-78), no patient had locoregional recurrence; 1 developed distant metastasis and died from the disease. Five-year local control, disease-free survival and disease-specific survival were 100%, 96% and 96%, respectively. Four patients (18%) presented grades 3-4 gastrointestinal toxicity, and 11 (50%), grade 3 vaginal toxicity. CONCLUSION: Recurrent vaginal endometrial cancer is amenable to salvage therapy with HDRB and EBRT.


Asunto(s)
Braquiterapia/métodos , Neoplasias Endometriales/diagnóstico por imagen , Recurrencia Local de Neoplasia/radioterapia , Neoplasias Vaginales/radioterapia , Anciano , Anciano de 80 o más Años , Relación Dosis-Respuesta en la Radiación , Neoplasias Endometriales/patología , Femenino , Humanos , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Radiografía , Terapia Recuperativa/métodos , Neoplasias Vaginales/patología
18.
J Obstet Gynaecol Can ; 27(11): 1023-6, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16529669

RESUMEN

BACKGROUND: Aggressive angiomyxoma is a rare, locally aggressive soft tissue tumour that chiefly involves the vulvoperineal region of young female patients. Treatment is wide surgical excision. Frequent relapses are common. CASES: We present three patients who each had an aggressive angiomyxoma treated initially for another presumed diagnosis. Two patients required immediate repeat surgical procedures for incomplete tumour excision. The third patient developed a recurrence two years after the initial surgery. In one patient, hormonal therapy was used postoperatively because the evaluation of the tumour margins was uncertain. Harpoon markers were used to aid in tumour localization in another patient prior to resection. CONCLUSION: Clinicians should consider the diagnosis of aggressive angiomyxoma when a patient presents with an atypical vulvoperineal mass, as an incorrect diagnosis may lead to repeated surgical procedures.


Asunto(s)
Mixoma/cirugía , Recurrencia Local de Neoplasia/cirugía , Perineo , Neoplasias de la Vulva/cirugía , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Mixoma/patología , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Perineo/patología , Reoperación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Neoplasias de la Vulva/patología
19.
Diabetes Care ; 26(3): 582-9, 2003 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12610005

RESUMEN

OBJECTIVE: Performance criteria have been established for in vitro blood glucose monitoring, particularly for the self-monitoring of blood glucose using glucose meters. Devices intended for use in the future, such as the continuous glucose monitoring system (CGMS), should satisfy similar criteria, particularly in diabetic patients under intensive therapy. RESEARCH DESIGN AND METHODS: The analysis was conducted on 18 type 1 diabetic patients (not controlled, HbA(1c) >7.5%) treated by external pump using insulin analogs. Each patient received a glucose sensor for 3 days during his/her hospitalization and was instructed in its operation. Medtronic criteria were used to determine the accuracy of the CGMS. In addition, the data were analyzed according to American Diabetes Association (ADA) criteria, Clarke Error Grid analysis, and method of residuals, with the glucose oxidase method using a Beckman analyzer used as the reference method. Specificity and sensitivity were evaluated from the viewpoint of accuracy in the detection of hypoglycemia. For nine patients, two glucose sensors were simultaneously inserted into an abdominal site to determine the reproducibility of the system. RESULTS-Among the 33 glucose sensors inserted, 6 (18%) were nonfunctional. The mean duration of CGMS recording was 63 +/- 12 h. From all of the 692 sets of data that paired glucose readings and CGMS, the coefficients of correlation ranged from 0.87 to 0.92 and the mean absolute error ranged from 12.8 to 15.7%. The time experienced in hypoglycemia (<55 mg/dl) was reported at 86 +/- 62 min/day. Only 39% of the CGMS values satisfied the ADA precision criteria to within +/-10%, and 19% of these values satisfied the future ADA precision criteria of accuracy to within +/-5%. The means of difference method showed that the CGMS slightly underestimated the plasma glucose values (mean = -12 mg/dl). Error grid analysis showed only 77% of the glucose sensor values were in zone A, and 98.9% were in zones A and B. Two values fell in zone C and a single value fell in zone D. The sensitivity and specificity of the CGMS to detect hypoglycemia were 33 and 96%, respectively. A total of 6666 paired sensor values were recorded with a coefficient of correlation of 0.84 with a coefficient of variation of 8.25%. CONCLUSIONS: CGMS could be useful in routine clinical practice to provide much more information on the glucose profile than intermittent self-monitoring of blood glucose (SMBG). However, CGMS cannot be used as a replacement for glucose meters because it does not satisfy the conventional performance goals set down for in vitro glucose measurements and could therefore lead to clinically incorrect treatment decisions.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adulto , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/normas , Falla de Equipo , Femenino , Humanos , Inyecciones Subcutáneas , Insulina/análogos & derivados , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Diabetes Care ; 26(4): 1137-41, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12663586

RESUMEN

OBJECTIVE: This study was designed to test the accuracy of capillary ketonemia for diagnosis of ketosis after interruption of insulin infusion. RESEARCH DESIGN AND METHODS: A total of 18 patients with type 1 diabetes treated by external pump were studied during pump stop for 5 h. Plasma and capillary ketonemia and ketonuria were determined every hour from 7:00 A.M. (time 0 min = T0) to 12:00 P.M. (time 300 min = T300). Plasma beta-hydroxybutyrate (beta-OHB) levels were measured by an enzymatic end point spectrophotometric method, and capillary beta-OHB levels were measured by an electrochemical method (MediSense Optium meter). Ketonuria was measured by a semiquantitative test (Ketodiastix). Positive ketosis was defined by a value of >/=0.5 mmol/l for ketonemia and >/=4 mmol/l (moderate) for ketonuria. RESULTS: After stopping the pump, concentrations of beta-OHB in both plasma and capillary blood increased significantly at time 60 min (T60) compared with T0 (P < 0.001), reaching maximum levels at T300 (1.30 +/- 0.49 and 1.23 +/- 0.78 mmol/l, respectively). Plasma and capillary beta-OHB values were highly correlated (r = 0.94, P < 0.0001). For diagnosis of ketosis, capillary ketonemia has a higher sensitivity and negative predictive value (80.4 and 82.5%, respectively) than ketonuria (63 and 71.8%, respectively). For plasma glucose levels >/=250 mg/dl, plasma and capillary ketonemia were found to be more frequently positive (85 and 78%, respectively) than ketonuria (59%) (P = 0.017). The time delay to diagnosis of ketosis was significantly higher for ketonuria than for plasma ketonemia (212 +/- 67 vs. 140 +/- 54 min, P = 0.0023), whereas no difference was noted between plasma and capillary ketonemia. CONCLUSIONS: The frequency of screening for ketosis and the efficiency of detection of ketosis definitely may be improved by the use of capillary blood ketone determination in clinical practice.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Capilares/fisiopatología , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cuerpos Cetónicos/sangre , Ácido 3-Hidroxibutírico/sangre , Adulto , Edad de Inicio , Glucemia/análisis , Péptido C/sangre , Cetoacidosis Diabética/sangre , Cetoacidosis Diabética/diagnóstico , Electroquímica/métodos , Dedos/irrigación sanguínea , Humanos , Sistemas de Infusión de Insulina , Cuerpos Cetónicos/orina , Distribución Normal , Tiras Reactivas , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA