Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JMIR Form Res ; 8: e50716, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38498047

RESUMEN

BACKGROUND: WA Notify was Washington State's smartphone-based COVID-19 digital exposure notification (EN) tool, which was used to help limit the spread of COVID-19 between November 30, 2020, and May 11, 2023. Following the 2022 Washington State Public Health Association Annual Conference, attendees who had WA Notify activated began receiving ENs alerting them to a possible COVID-19 exposure during the conference. A survey was emailed to all conference attendees to measure WA Notify adoption, mechanisms through which attendees received ENs, and self-reported engagement in protective behaviors postexposure. OBJECTIVE: This study aimed to learn more about the experiences of WA Notify adopters and nonadopters who may have been exposed to COVID-19 at a large group gathering. METHODS: A web-based survey administered through REDCap (Research Electronic Data Capture; Vanderbilt University) was sent to all attendees of the Washington State Public Health Association conference. Self-reported demographic information and characteristics of respondents were summarized. Regression models were used to estimate relative risks to compare WA Notify adoption and testing behaviors between groups. RESULTS: Of the 464 total registered attendees who were sent the survey, 205 (44%) responses were received; 201 eligible attendees were included in this analysis. Of those, 149 (74%) respondents reported having WA Notify activated on their phones at the time of the conference. Among respondents with WA Notify activated, 54% (n=77) reported learning of their potential exposure from a WA Notify EN. Respondents who reported that they did not have WA Notify activated and learned of their potential exposure via the event-wide email from conference organizers were 39% less likely to test for COVID-19 compared to respondents with WA Notify activated who learned of their potential exposure from the email (relative risk 0.61, 95% CI 0.40-0.93; P=.02), and this gap was even larger when compared to respondents who learned of their exposure from a WA Notify EN. The most commonly cited reason for not having WA Notify activated was privacy concerns (n=17, 35%), followed by not wanting to receive ENs (n=6, 12%) and being unaware of WA Notify (n=5, 10%). CONCLUSIONS: Digital EN systems are an important tool to directly and anonymously notify close contacts of potential exposures and provide guidance on the next steps in a timely manner. Given the privacy concerns, there is still a need for increasing transparency surrounding EN technology to increase uptake by the public if this technology were to be used in the future to slow the spread of communicable diseases.

2.
Br J Anaesth ; 126(5): 975-984, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33640118

RESUMEN

BACKGROUND: Several devices record and interpret patient brain activity via electroencephalogram (EEG) to aid physician assessment of anaesthetic effect. Few studies have compared EEG monitors on data from the same patient. Here, we describe a set-up to simultaneously compare the performance of three processed EEG monitors using pre-recorded EEG signals from older surgical patients. METHODS: A playback system was designed to replay EEG signals into three different commercially available EEG monitors. We could then simultaneously calculate indices from the SedLine® Root (Masimo Inc., Irvine, CA, USA; patient state index [PSI]), bilateral BIS VISTA™ (Medtronic Inc., Minneapolis, MN, USA; bispectral index [BIS]), and Datex Ohmeda S/5 monitor with the Entropy™ Module (GE Healthcare, Chicago, IL, USA; E-entropy index [Entropy]). We tested the ability of each system to distinguish activity before anaesthesia administration (pre-med) and before/after loss of responsiveness (LOR), and to detect suppression incidences in EEG recorded from older surgical patients receiving beta-adrenergic blockers. We show examples of processed EEG monitor output tested on 29 EEG recordings from older surgical patients. RESULTS: All monitors showed significantly different indices and high effect sizes between comparisons pre-med to after LOR and before/after LOR. Both PSI and BIS showed the highest percentage of deeply anaesthetised indices during periods with suppression ratios (SRs) > 25%. We observed significant negative correlations between percentage of suppression and indices for all monitors (at SR >5%). CONCLUSIONS: All monitors distinguished EEG changes occurring before anaesthesia administration and during LOR. The PSI and BIS best detected suppressed periods. Our results suggest that the PSI and BIS monitors might be preferable for older patients with risk factors for intraoperative awareness or increased sensitivity to anaesthesia.


Asunto(s)
Antagonistas Adrenérgicos beta/farmacología , Anestésicos/farmacología , Electroencefalografía/instrumentación , Monitoreo Intraoperatorio/métodos , Anciano , Anciano de 80 o más Años , Monitores de Conciencia , Femenino , Humanos , Masculino , Monitoreo Intraoperatorio/instrumentación , Factores de Riesgo
3.
Front Neurosci ; 12: 645, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30294254

RESUMEN

While geriatric patients have a high likelihood of requiring anesthesia, they carry an increased risk for adverse cognitive outcomes from its use. Previous work suggests this could be mitigated by better intraoperative monitoring using indexes defined by several processed electroencephalogram (EEG) measures. Unfortunately, inconsistencies between patients and anesthetic agents in current analysis techniques have limited the adoption of EEG as standard of care. In attempts to identify new analyses that discriminate clinically-relevant anesthesia timepoints, we tested 1/f frequency scaling as well as measures of complexity from nonlinear dynamics. Specifically, we tested whether analyses that characterize time-delayed embeddings, correlation dimension (CD), phase-space geometric analysis, and multiscale entropy (MSE) capture loss-of-consciousness changes in EEG activity. We performed these analyses on EEG activity collected from a traditionally hard-to-monitor patient population: geriatric patients on beta-adrenergic blockade who were anesthetized using a combination of fentanyl and propofol. We compared these analyses to traditional frequency-derived measures to test how well they discriminated EEG states before and after loss of response to verbal stimuli. We found spectral changes similar to those reported previously during loss of response. We also found significant changes in 1/f frequency scaling. Additionally, we found that our phase-space geometric characterization of time-delayed embeddings showed significant differences before and after loss of response, as did measures of MSE. Our results suggest that our new spectral and complexity measures are capable of capturing subtle differences in EEG activity with anesthesia administration-differences which future work may reveal to improve geriatric patient monitoring.

4.
Front Hum Neurosci ; 12: 173, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29867405

RESUMEN

Nitrous oxide (N2O) and remifentanil (remi) are used along with other anesthetic and adjuvant agents for routine surgical anesthesia, yet the electroencephalogram (EEG) changes produced by this combination are poorly described. N2O administered alone produces EEG spectral characteristics that are distinct from most hypnotics. Furthermore, EEG frequency-derived trends before and after clinically relevant time points vary depending on N2O concentration. Remifentanil typically increases low frequency and decreases high frequency activity in the EEG, but how it influences N2O's EEG effect is not known. Previous attempts to characterize EEG signals of patients anesthetized with N2O using frequency-derived measures have shown conflicts and inconsistencies. Thus, in addition to determining the spectral characteristics of this unique combination, we also test whether a newly proposed characterization of time-delayed embeddings of the EEG signal tracks loss and recovery of consciousness significantly at clinically relevant time points. We retrospectively investigated the effects of remi and N2O on EEG signals recorded from 32 surgical patients receiving anesthesia for elective abdominal surgeries. Remifentanil and N2O (66%) were co-administered during the procedures. Patients were tested for loss and recovery of response (ROR) to verbal stimuli after induction and upon cessation of anesthesia, respectively. We found that the addition of remifentanil to N2O anesthesia improves the ability of traditional frequency-derived measures, including the Bispectral Index (BIS), to discriminate between loss and ROR. Finally, we found that a novel analysis of EEG using nonlinear dynamics showed more significant differences between states than most spectral measures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...