Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Diagn Interv Imaging ; 101(9): 507-517, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32094095

RESUMEN

Magnetic resonance imaging (MRI) has become the reference imaging for the management of a large number of diseases. The number of MR examinations increases every year, simultaneously with the number of patients receiving a cardiac electronic implantable device (CEID). A CEID was considered an absolute contraindication for MRI for years. The progressive replacement of conventional pacemakers and defibrillators by MR-conditional CEIDs and recent data on the safety of MRI in patients with "MR-nonconditional" CEIDs have progressively increased the demand for MRI in patients with a CEID. However, some risks are associated with MRI in CEID carriers, even with "MR-conditional" devices because these devices are not "MR-safe". A specific programing of the device in "MR-mode" and monitoring patients during MRI remain mandatory for all patients with a CEID. A standardized patient workflow based on an institutional protocol should be established in each institution performing such examinations. This joint position paper of the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the Société française d'imagerie cardiaque et vasculaire diagnostique et interventionnelle (SFICV) describes the effect and risks associated with MRI in CEID carriers. We propose recommendations for patient workflow and monitoring and CEID programming in MR-conditional, "MR-conditional nonguaranteed" and MR-nonconditional devices.


Asunto(s)
Cardiología , Desfibriladores Implantables , Marcapaso Artificial , Electrónica , Humanos , Imagen por Resonancia Magnética
2.
Diagn Interv Imaging ; 101(2): 59-67, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31519470

RESUMEN

PURPOSE: To evaluate the potential of non-contrast myocardial T1 mapping on cardiovascular magnetic resonance examination (CMR) in differentiating patients with Fabry disease (FD) from those with hypertrophic cardiomyopathy (HCM) and healthy control subjects. MATERIALS AND METHODS: Seventeen patients with FD (8 men, 9 women; mean age, 48 ±18 [SD] years; [range: 19-73 years]; 53% with left ventricular hypertrophy [LVH]) were matched with 36 patients with hypertrophic cardiomyopathy (HCM) (22 men, 14 women; mean age, 57±16 [SD] years; [range: 22-85 years]) and 70 healthy control subjects (34 men, 36 women; mean age, 38 ±15 [SD] years; [range: 18-65 years]). Cardiac T1 mapping was performed using the modified Look-Locker inversion (MOLLI®) sequence on a 1.5-T magnet. T1 values were calculated, on midventricular section, for septal left ventricular segments (S8-S9) and all mid-ventricular ones (global T1 values; S7-S12). Statistical analysis included unpaired Mann-Whitney test, receiver operating characteristic curve and likelihood ratios. RESULTS: Septal native T1 values were significantly decreased in patients with FD (889±61 [SD] ms; range: 784-980ms) compared to those with HCM (995±48 [SD] ms; range: 935-1125ms) (P<0.001) and versus healthy controls (965±29 [SD] ms; range: 910-1028ms) (P<0.001). Global native T1 values were also significantly decreased in patients with FD (891±49 [SD] ms; range 794-970ms) compared to those with HCM (995±34 [SD] ms; range: 952-1086ms) (P<0.001) and versus healthy controls (966±27 [SD] ms; range: 920-1042ms) (P<0.001). A septal left ventricular native T1 cutoff value of 940ms could distinguish FD from HCM with 88% sensitivity (95% CI: 73-100%) and 92% specificity (95% CI: 83-100%). Positive likelihood ratio was 11, negative likelihood ratio was 0.12. Compared to controls, the same threshold could distinguish FD with 88% sensitivity (95% CI: 73-100%) and 86% specificity (95% CI: 78-94%). Positive likelihood ratio was 6.3, negative likelihood ratio was 0.14. T1 value was abnormal in 4 of 8 (50%) of FD patients who did not have LVH. CONCLUSION: Native T1 values are significantly lower in patients with FD by comparison with those with HCM and healthy volunteers.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico , Mapeo Epicárdico , Enfermedad de Fabry/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
4.
Diagn Interv Imaging ; 99(11): 689-698, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30262171

RESUMEN

PURPOSE: The purpose of this study was to quantify the distribution of trabeculated (T) and compact (C) left ventricular (LV) myocardium masses in a healthy Caucasian population against age, gender and LV parameters, and to provide normal values for T, C and T/C. MATERIALS AND METHODS: One hundred and forty healthy subjects were prospectively recruited and underwent cardiac MRI at 1.5T with a stack of short-axis cine sequences covering the entire LV. End-diastolic volume (EDV), C and T masses were quantified using a semi-automatic method. Ejection fraction (EF) and T/C ratio were computed. RESULTS: We included 70 men and 70 women with a mean age of 44±14 (SD) years (range: 20-69 years). The mean EF was 63.7±6.3 (SD) % (range: 50.7-82.0%), the mean EDV was 75.9±16.2 (SD) mL/m2 (range: 36.4-112.2mL/m2), the mean C mass was 53.9±11.2 (SD) g/m2 (range: 26.5-93.4g/m2) and the mean T mass was 4.9±2.4 (SD) g/m2 (range: 1.1-11.4g/m2). The T/C ratio was 9.2±4.5% (range: 2.0-29.4%). Multivariate ANOVA test showed that the compact mass was influenced by EDV (P<0.0001), EF (P=0.001) and gender (P<0.0001), and the trabeculated mass depended on EDV (P<0.0001), gender (P=0.002) and age (P<0.0001), while the T/C ratio was only influenced by age (P=0.0003). Spearman test showed a correlation between EDV and C (r=0.60; P<0.0001),T (r=0.46; P<0.0001) and T/C ratio (r=0.26; P=0.0023).T and T/C ratio correlated with EF (r=-0.18, P=0.0373; r=-0.18, P=0.0321, respectively). CONCLUSION: While the compact and trabeculated myocardium masses appear to relate separately to the cardiac function, age and gender, their ratio T/C appears to only decrease with age. Furthermore, we propose here normal values for T, C and T/C in a cohort of healthy Caucasians subjects.


Asunto(s)
Técnicas de Imagen Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Factores de Edad , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Factores Sexuales , Población Blanca , Adulto Joven
7.
Diagn Interv Imaging ; 99(5): 279-289, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29307461

RESUMEN

PURPOSE: To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. METHODS: MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. RESULTS: Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. CONCLUSION: Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos
13.
Diagn Interv Imaging ; 97(5): 505-12, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27012158

RESUMEN

The management of patients with congenital heart disease was profoundly changed firstly by the advent of pediatric and prenatal ultrasound and then more recently by cardiac magnetic resonance imaging (MRI) and computed tomography (CT) of the heart and great vessels. The improved life expectancy of these patients has brought about new medical and imaging requirements. MRI and CT are increasing second line techniques in this group of patients. This article summarizes the advantages and limitations of CT and MRI in some frequently encountered situations in children and adults followed up for congenital heart disease.


Asunto(s)
Técnicas de Imagen Cardíaca/tendencias , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Imagen por Resonancia Magnética/tendencias , Tomografía Computarizada por Rayos X/tendencias , Adulto , Niño , Predicción , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/tendencias , Sensibilidad y Especificidad
18.
Diagn Interv Imaging ; 94(12): 1337-44, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23849751

RESUMEN

The analysis of myocardial perfusion is a key step in the cardiac MRI examination. In routine work, this exploration carried out at rest is based on the qualitative first pass study of gadolinium with an ECG-triggered saturation recovery bFFE sequence. In view of recent knowledge, the analysis of the myocardial perfusion under vasodilator stress may be carried out by scintigraphy or MRI, the latter benefiting from the absence of exposure to ionizing rays and a lower cost. Besides coronary disease, the perfusion sequence provides a rich semiology to compare with the clinics and the data from other sequences. Arterial Spin Labeling (ASL) is an alternative technique used in the animal to quantify myocardial perfusion.


Asunto(s)
Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Cardiomiopatías/diagnóstico , Humanos , Imagen de Perfusión Miocárdica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA