Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 89(2): 023304, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29495838

RESUMEN

The SEPAGE diagnostic will detect charged particles (electrons, protons, and ions) accelerated in the interaction of the PETAL (PETawatt Aquitaine Laser) laser with its targets on the LMJ (Laser MegaJoule)-PETAL laser facility. SEPAGE will be equipped with a proton-radiography front detector and two Thomson parabolas (TP), corresponding to different ranges of the particle energy spectra: Above 0.1 MeV for electrons and protons in the low-energy channel, with a separation capability between protons and 12C6+ up to 20 MeV proton energy and above 8 MeV for the high-energy channel, with a separation capability between protons and 12C6+ up to 200 MeV proton kinetic energy. This paper presents the calibration of the SEPAGE's low-energy channel TP at the Tandem facility of Orsay (France) with proton beams between 3 and 22 MeV and carbon-ion beams from 5.8 to 84 MeV. The magnetic and electric fields' integrals were determined with an accuracy of 10-3 by combining the deflections measured at different energies with different target thicknesses and materials, providing different in-target energy losses of the beam particles and hence different detected energies for given beam energies.

2.
Rev Sci Instrum ; 88(11): 113301, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29195357

RESUMEN

Responses of Fuji Imaging Plates (IPs) to proton have been measured in the range 1-200 MeV. Mono-energetic protons were produced with the 15 MV ALTO-Tandem accelerator of the Institute of Nuclear Physics (Orsay, France) and, at higher energies, with the 200-MeV isochronous cyclotron of the Institut Curie-Centre de Protonthérapie d'Orsay (Orsay, France). The experimental setups are described and the measured photo-stimulated luminescence responses for MS, SR, and TR IPs are presented and compared to existing data. For the interpretation of the results, a sensitivity model based on the Monte Carlo GEANT4 code has been developed. It enables the calculation of the response functions in a large energy range, from 0.1 to 200 MeV. Finally, we show that our model reproduces accurately the response of more complex detectors, i.e., stack of high-Z filters and IPs, which could be of great interest for diagnostics of Petawatt laser accelerated particles.

3.
Rev Sci Instrum ; 87(10): 103505, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27802760

RESUMEN

Laser produced plasmas lend to several interesting applications. The study of X-ray emission from this kind of plasmas is important not only to characterize plasmas itself but also to study the application of these particular plasmas as intense X-ray sources. In particular several emission configurations can be obtained using different kinds of targets and tuning the characteristics of the laser pulse delivered to the target. Typically, laser pulse duration ranges between a few tens of femtoseconds and tens of nanoseconds, with energies from few mJ to tens of kJ. X-ray photon emissions last for times comparable to the laser pulses and during this time a great number of photons can be emitted. The following paper presents a measure of the soft-X-ray emission on the ECLIPSE laser facility realized with a new triple-GEM gas detector (GEMpix). It is a hybrid gas detector with a C-MOS front-end electronics based on Medipix chips. In the present work, different targets have been used in order to test X-rays of different energies. In this paper, in particular, we present results obtained for copper and iron targets. GEMpix is able to realize a 2D imaging of the X-ray emission from plasma with a signal proportional to the energy released in the gas of the detector active volume. Then through a preliminary single photon equalization realized at the NIXT lab (ENEA), also the number of photons reaching the area of the detector has been estimated.

4.
Rev Sci Instrum ; 87(5): 053306, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250413

RESUMEN

This paper presents the response calibration of Imaging Plates (IPs) for electrons in the 40-180 MeV range using laser-accelerated electrons at Laboratoire d'Optique Appliquée (LOA), Palaiseau, France. In the calibration process, the energy spectrum and charge of electron beams are measured by an independent system composed of a magnetic spectrometer and a Lanex scintillator screen used as a calibrated reference detector. It is possible to insert IPs of different types or stacks of IPs in this spectrometer in order to detect dispersed electrons simultaneously. The response values are inferred from the signal on the IPs, due to an appropriate charge calibration of the reference detector. The effect of thin layers of tungsten in front and/or behind IPs is studied in detail. GEANT4 simulations are used in order to analyze our measurements.

5.
Rev Sci Instrum ; 87(4): 043108, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-27131655

RESUMEN

Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

6.
Rev Sci Instrum ; 86(11): 113304, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26628126

RESUMEN

Imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. We calibrated at the ELSA electron beam facility (CEA DIF) the five different available types of IPs (namely, MS-SR-TR-MP-ND) to electrons from 5 to 18 MeV. In the context of diagnostic development for the PETawatt Aquitaine Laser (PETAL), we investigated the use of stacks of IP in order to increase the detection efficiency and get detection response independent from the neighboring materials such as X-ray shielding and detector supports. We also measured fading functions in the time range from a few minutes up to a few days. Finally, our results are systematically compared to GEANT4 simulations in order to provide a complete study of the IP response to electrons over the energy range relevant for PETAL experiments.

7.
Rev Sci Instrum ; 86(8): 083307, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26329181

RESUMEN

Laser-accelerated ion beams can be used in many applications and, especially, to initiate nuclear reactions out of thermal equilibrium. We have experimentally studied aneutronic fusion reactions induced by protons accelerated by the Target Normal Sheath Acceleration mechanism, colliding with a boron target. Such experiments require a rigorous method to identify the reaction products (alpha particles) collected in detectors among a few other ion species such as protons or carbon ions, for example. CR-39 track detectors are widely used because they are mostly sensitive to ions and their efficiency is near 100%. We present a complete calibration of CR-39 track detector for protons, alpha particles, and carbon ions. We give measurements of their track diameters for energy ranging from hundreds of keV to a few MeV and for etching times between 1 and 8 h. We used these results to identify alpha particles in our experiments on proton-boron fusion reactions initiated by laser-accelerated protons. We show that their number clearly increases when the boron fuel is preformed in a plasma state.

8.
Rev Sci Instrum ; 83(10): 10E134, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126955

RESUMEN

An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

9.
Phys Rev Lett ; 102(15): 152701, 2009 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-19518626

RESUMEN

The A/Z dependence of projectile fragmentation at relativistic energies has been studied with the ALADIN forward spectrometer at SIS. A stable beam of (124)Sn and radioactive beams of (124)La and (107)Sn at 600 MeV per nucleon have been used in order to explore a wide range of isotopic compositions. Chemical freeze-out temperatures are found to be nearly invariant with respect to the A/Z of the produced spectator sources, consistent with predictions for expanded systems. Small Coulomb effects (DeltaT approximately 0.6 MeV) appear for residue production near the onset of multifragmentation.

10.
Phys Rev Lett ; 100(2): 022701, 2008 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-18232861

RESUMEN

The spallation of 56Fe in collisions with hydrogen at 1A GeV has been studied in inverse kinematics with the large-aperture setup SPALADIN at GSI. Coincidences of residues with low-center-of-mass kinetic energy light particles and fragments have been measured allowing the decomposition of the total reaction cross section into the different possible deexcitation channels. Detailed information on the evolution of these deexcitation channels with excitation energy has also been obtained. The comparison of the data with predictions of several deexcitation models coupled to the INCL4 intranuclear cascade model shows that only GEMINI can reasonably account for the bulk of collected results, indicating that in a light system with no compression and little angular momentum, multifragmentation might not be necessary to explain the data.