Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 7(1): 11539, 2017 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-28912496

RESUMEN

We describe a magnetic field sensor based on a spin wave interferometer. Its sensing element consists of a magnetic cross junction with four micro-antennas fabricated at the edges. Two of these antennas are used for spin wave excitation while two other antennas are used for detection of the inductive voltage produced by the interfering spin waves. Two waves propagating in the orthogonal arms of the cross may accumulate significantly different phase shifts depending on the magnitude and direction of the external magnetic field. This phenomenon is utilized for magnetic field sensing. The sensitivity attains its maximum under the destructive interference condition, where a small change in the external magnetic field results in a drastic increase of the inductive voltage, as well as in the change of the output phase. We report experimental data obtained for a micrometer scale Y3Fe2(FeO4)3 cross structure. The change of the inductive voltage near the destructive interference point exceeds 40 dB per 1 Oe. The phase of the output signal exhibits a π-phase shift within 1 Oe. The data are collected at room temperature. Taking into account the low thermal noise in ferrite structures, we estimate that the maximum sensitivity of the spin wave magnetometer may exceed attotesla.

3.
Ortop Travmatol Protez ; (2): 46-8, 1990 Feb.
Artículo en Ruso | MEDLINE | ID: mdl-2359608

RESUMEN

The author analyses his experience in using polymer metalic endoprostheses in 36 patients with medial fractures and false joints of the femoral neck in the elderly persons. The average age of the patients operated was 74 years. The head and the neck of the endoprosthesis were made of polymer: polyamide-12 and its limb was made of metal: titan BT-5. The immediate and the long-term results (6 months to 10 years) have been studied. The functional results of endoprosthetics were good in 27 cases (81.8%), satisfactory in 4 cases (12.2%) and bad in 2 cases (6%). Using polymer (polyamide-12) as a construction material for endoprostheses contributes to a softer transmission of the efforts and stresses from the articular cartilage to the subchondral and remote parts of the skeleton and improves the restoration of the biomechanical equilibrium between the endoprosthesis and the bone structure.


Asunto(s)
Fracturas no Consolidadas/cirugía , Fracturas de Cadera/cirugía , Prótesis de Cadera , Nylons , Titanio , Factores de Edad , Anciano , Femenino , Humanos , Masculino , Resistencia a la Tracción , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA