Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Oncogene ; 25(22): 3196-205, 2006 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-16407825

RESUMEN

In order to analyse the relationships between regulation of apoptosis and homologous recombination (HR), we overexpressed proapoptotic Bax or only-BH3 Bid proteins or antiapoptotic Bcl-2 or Bcl-XL, in hamster CHO cells or in SV40-transformed human fibroblasts. We measured HR induced by gamma-rays, UVC or a specific double-strand cleavage targeted in the recombination substrate by the meganuclease I-SceI. We show here that the induction of both recombinant cells and recombinant colonies was impaired when expressing Bcl-2 family members, in hamster as well as in human cells. Moreover, the pro- as well as antiapoptotic Bcl-2 family members inhibited HR, independently of degradation of the RAD51 recombination protein and of their impact on apoptosis. These data reveal a mechanism of HR downregulation by potentially proapoptotic proteins, distinct from and parallel to degradation of recombination proteins, a situation that should also optimize the efficiency of programmed cell death.


Asunto(s)
Apoptosis , Proteína Proapoptótica que Interacciona Mediante Dominios BH3/metabolismo , Recombinación Genética , Proteína X Asociada a bcl-2/metabolismo , Proteína bcl-X/metabolismo , Animales , Western Blotting , Células CHO/metabolismo , Células CHO/efectos de la radiación , Cricetinae , Desoxirribonucleasas de Localización Especificada Tipo II/metabolismo , Fibroblastos/metabolismo , Fibroblastos/efectos de la radiación , Técnica del Anticuerpo Fluorescente , Rayos gamma , Humanos , Recombinasa Rad51/metabolismo , Proteínas de Saccharomyces cerevisiae , Rayos Ultravioleta
2.
Stud Health Technol Inform ; 103: 93-100, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15747910

RESUMEN

Information and Communication Technology (ICT) assist healthcare professionals in the process of diagnosis, treatment, monitoring, medication prescription, referral, information retrieval and communication, documentation and transactions. This applies to intramural, transmural and extramural conditions. About 67% of patients involved in safety incidents believe that the incidents could have been prevented had an electronic health record been available. However, preliminary research also suggests that about 30% of patient safety incidents relate to software problems. ICT might improve quality of healthcare provided that ICT products, the ICT administration and use comply to essential requirements. This paper presents information about the state of the art of software quality, the measuring of software quality, quality management systems and a evaluation and certification method.


Asunto(s)
Informática Médica/instrumentación , Informática Médica/organización & administración , Sistemas de Registros Médicos Computarizados , Validación de Programas de Computación , Errores Médicos/prevención & control , Sistemas de Registros Médicos Computarizados/instrumentación , Sistemas de Registros Médicos Computarizados/organización & administración , Garantía de la Calidad de Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/organización & administración , Control de Calidad , Medición de Riesgo , Administración de la Seguridad/métodos , Administración de la Seguridad/organización & administración
3.
Artículo en Inglés | MEDLINE | ID: mdl-15058407

RESUMEN

A standard is a set of agreements between all parties involved. Delivering healthcare is a matter of co-operation: healthcare can only be delivered in a responsible fashion when parties involved comply to standards. This becomes evident when a healthcare information infrastructure is under development. The authors deliver a comprehensive introduction to standards which apply to the Electronic Healthcare Record (EHR), describe work in progress of relevant standardisation committees and argue about future work of such committees in order to pursue a coherent healthcare information infrastructure.


Asunto(s)
Gestión de la Información/organización & administración , Gestión de la Información/normas , Sistemas de Registros Médicos Computarizados/organización & administración , Sistemas de Registros Médicos Computarizados/normas , Redes de Comunicación de Computadores/organización & administración , Redes de Comunicación de Computadores/normas , Documentación/métodos , Documentación/normas , Relaciones Interprofesionales , Registro Médico Coordinado/métodos , Registro Médico Coordinado/normas
4.
EMBO J ; 20(10): 2596-607, 2001 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-11350949

RESUMEN

The oncogenic role of Bcl-2 is generally attributed to its protective effect against apoptosis. Here, we show a novel role for Bcl-2: the specific inhibition of the conservative RAD51 recombination pathway. Bcl-2 or Bcl-X(L) overexpression inhibits UV-C-, gamma-ray- or mutant p53-induced homologous recombination (HR). Moreover, Bcl-2 recombination inhibition is independent of the role of p53 in G1 arrest. At an acute double-strand break in the recombination substrate, Bcl-2 specifically inhibits RAD51-dependent gene conversion without affecting non-conservative recombination. Bcl-2 consistently thwarts recombination stimulated by RAD51 overexpression and alters Rad51 protein by post-translation modification. Moreover, a mutant (G145A)Bcl-2, which is defective in Bax interaction and in apoptosis repression, also inhibits recombination, showing that the death and recombination repression functions of Bcl-2 are separable. Inhibition of error-free repair pathways by Bcl-2 results in elevated frequencies of mutagenesis. The Bcl-2 gene therefore combines two separable cancer-prone phenotypes: apoptosis repression and a genetic instability/mutator phenotype. This dual phenotype could represent a mammalian version of the bacterial SOS repair system.


Asunto(s)
Reparación del ADN , Proteínas de Unión al ADN/metabolismo , Proteínas Proto-Oncogénicas c-bcl-2/fisiología , Recombinación Genética , Transducción de Señal/fisiología , Animales , Línea Celular , Proteínas de Unión al ADN/genética , Ratones , Fenotipo , Procesamiento Proteico-Postraduccional , Proteínas Proto-Oncogénicas c-bcl-2/genética , Proteínas Proto-Oncogénicas c-bcl-2/metabolismo , Recombinasa Rad51 , Proteína p53 Supresora de Tumor/metabolismo , Rayos Ultravioleta , Proteína bcl-X
5.
Immunogenetics ; 45(4): 235-41, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9002443

RESUMEN

Polymerase chain reaction was used to isolate cDNA clones encoding putative T-cell receptor (TCR) alpha chains in an amphibian, the Mexican axolotl (Ambystoma mexicanum). Five TCRalpha-V chain-encoding segments were identified, each belonging to a separate family. The best identity scores for these axolotl TCRalpha-V segments were all provided by sequences belonging to the human TCRalpha-V1 family and the mouse TCRalpha-V3 and TCRalpha-V8 families. A total of 14 different TCRA-J segments were identified from 44 TCRA-V/TCRA-J regions sequenced, suggesting that a large repertoire of TCRA-J segments is a characteristic of most vertebrates. The structure of the axolotl CDR3 alpha chain loop is in good agreement with that of mammals, including a majority of small hydrophobic residues at position 92 and of charged, hydrophilic, or polar residues at positions 93 and 94, which are highly variable and correspond to the TCRA-V/J junction. This suggests that some positions of the axolotl CDR3 alpha chain loop are positively selected during T-cell differentiation, particularly around residue 93 that could be selected for its ability to makes contacts with major histocompatibility complex-associated antigenic peptides, as in mammals. The axolotl Calpha domain had the typical structure of mammalian and avian Calpha domains, including the charged residues in the TM segment that are thought to interact with other proteins in the membrane, as well as most of the residues forming the conserved antigen receptor transmembrane motif.


Asunto(s)
Variación Genética , Receptores de Antígenos de Linfocitos T alfa-beta/química , Receptores de Antígenos de Linfocitos T alfa-beta/genética , Ambystoma , Secuencia de Aminoácidos , Animales , Secuencia de Consenso , Humanos , Datos de Secuencia Molecular , Reacción en Cadena de la Polimerasa , Alineación de Secuencia
6.
Technol Health Care ; 3(2): 75-89, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8574765

RESUMEN

Virtual Environments allow a human to interact with a (computer) system in such a way that a high level of presence in a computer-synthesised world is experienced. In principle, all human senses are involved with the interaction. Many applications may benefit from this type of human-machine interfacing, however, few have emerged so far for medicine. In this paper we elaborate on some realistic potential applications of Virtual Environment technology in the field of medicine. These applications can be found in education/training, therapy, surgery, rehabilitation, diagnosis, telemedicine and biomechanics. The value to be added to these applications by VE technology lies in the fact that patient data or patient models may be moderated to the physician in a more intuitive and natural manner. Despite these potentials, the short-term feasibility of these applications can be put into question for various reasons. Firstly, the current generation of display devices have a resolution that may show to be too low to achieve a sufficiently high degree of realism for medical applications. Secondly, there are no commercially-available actuators for tactile and force feedback which the physician desperately need for the simulation of the contact with the (virtual) patient. Thirdly, the enormous computing power required for these applications (still) needs a considerable investment. With these limitations in mind, we believe that we are at the cradle of a whole new generation of VE applications in medicine.


Asunto(s)
Simulación por Computador , Aplicaciones de la Informática Médica , Interfaz Usuario-Computador , Diagnóstico por Computador , Educación Médica , Estudios de Factibilidad , Retroalimentación , Humanos , Evaluación de la Tecnología Biomédica , Telemedicina
7.
Comput Biol Med ; 25(2): 139-48, 1995 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-7554832

RESUMEN

The minimally invasive nature of endoscopic surgery allows operations to be performed on patients through small incisions, often under local anaesthesia. Patient recovery times and cosmetic detriment are thus greatly reduced, while overall quality of care is improved. Presently, surgeons are trained to perform endosurgical procedures in a number of ways: practising with surgical training devices, using animal models and assisting experienced surgeons. In this paper, the focus is on answering the key question: "Can virtual environment technology assist surgeons in training and maintaining endoscopic surgery skills?" Initial developments towards surgical simulators have clearly demonstrated the great potential of virtual environment technology for surgical training purposes. Breakthroughs towards surgery are expected within the next 5 to 10 years.


Asunto(s)
Simulación por Computador , Educación de Postgrado en Medicina , Endoscopía , Cirugía General/educación , Competencia Clínica , Predicción , Humanos , Modelos Anatómicos , Modelos Biológicos
8.
Int J Card Imaging ; 10(3): 205-15, 1994 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7876660

RESUMEN

For clinical decision-making and documentation purposes we have developed techniques to extract, label and analyze the coronary vasculature from arteriograms in an automated, quantitative manner. Advanced image processing techniques were applied to extract and analyze the vasculatures from non-subtracted arteriograms while artificial intelligence techniques were employed to assign anatomical labels. Lumen diameters of 11 phantom vessels were assessed with an accuracy of 0.27 +/- 0.19 mm (dtrue = 0.45 + 0.92dmeasured; r > 0.99) and 0.21 +/- 0.15 mm (dtrue = 0.42 + 0.91dmeasured; r > 0.99), from cine and digital images, respectively. We collected a total of 15 routinely acquired cine-arteriograms showing 74 vessel segments with 18 stenoses (severity larger than 30% assessed quantitatively), and 53 digital arteriograms showing 236 vessel segments with 69 stenoses. From the cine arteriograms we extracted 64 (86%) of the vessel segments without manual correction and 196 (83%) from the digital arteriograms. Repeated analysis (3 times) of the arteriograms by the same operator resulted in a standard deviation of the mean segment diameters (precision) of 0.064 mm for the cine-images and 0.020 mm for the digital images, while the standard deviations in the measurement of the minimal luminal diameter of the observed stenoses were 0.020 mm and 0.019 mm, respectively. The LAD artery, the septal and diagonal branches were correctly identified automatically in 86% of the segments. From these evaluations we conclude that our automated approach provides reliable tools for the assessment of multi-vessel disease, both in an off- and on-line environment.


Asunto(s)
Angiografía Coronaria , Interpretación de Imagen Radiográfica Asistida por Computador , Cineangiografía/métodos , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Técnicas In Vitro , Modelos Estructurales
9.
IEEE Trans Med Imaging ; 13(1): 13-24, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-18218480

RESUMEN

Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain such views with computer-assisted techniques. The object of interest is first visualized in two arbitrary views. Two landmarks of the object are manually defined in the two projection images. With complete information of the projection geometry, the vector representation of the object in the three-dimensional space is computed. This vector is perpendicular to a plane in which the views are called optimal. The user has one degree of freedom to define a set of optimal biplane views. The angle between the central beams of the imaging systems can be chosen freely. The computation of the orientation of the object and of corresponding optimal biplane views have been evaluated with a simple hardware phantom. The mean and the standard deviation of the overall errors in the calculation of the optimal angulation angles were 1.8 degrees and 1.3 degrees , respectively, when the user defined a rotation angle.

10.
Clin Exp Rheumatol ; 8(3): 259-64, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-1696191

RESUMEN

The antiperinuclear factor (APF) test raises two main problems: the unpredictability of the cells used as substrate and the difficulty in expressing the results. We propose that 10% of the cells have to be stained by a given serum in order for it to be considered positive. APF were found to be present in 76% of rheumatoid arthritis (RA) patients, 3% of healthy controls and occasionally in disease controls. The production of APF was significantly (p less than 0.01) related to the presence of rheumatoid factor in RA, and IgG antibody was predominant in the APF test.


Asunto(s)
Anticuerpos Antinucleares/análisis , Anticuerpos Antinucleares/inmunología , Artritis Reumatoide/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Autoanticuerpos/análisis , Mejilla , Estudios de Evaluación como Asunto , Femenino , Prueba de Histocompatibilidad , Humanos , Inmunoglobulina G/análisis , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Mucosa Bucal/análisis , Coloración y Etiquetado
11.
Clin Exp Rheumatol ; 8(3): 265-9, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2165883

RESUMEN

Since the antiperinuclear factor (APF) test on human buccal cells is rather unpredictable, we have investigated the possible factors determining the expression of appropriate antigens by the cells. We failed to find any relationship of the expression of perinuclear antigens to the donor's smoking habits, the degree of contamination with saprophytic bacteria, the presence or absence of blood group substances in saliva, or the titers of serum antibodies to Epstein-Barr virus. Family studies were also performed to further elucidate a genetic predisposition to the expression of the APF antigen.


Asunto(s)
Anticuerpos Antiidiotipos/análisis , Anticuerpos Antinucleares/análisis , Anticuerpos Antivirales/análisis , Artritis Reumatoide/inmunología , Herpesvirus Humano 4/inmunología , Sistema del Grupo Sanguíneo ABO/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antinucleares/genética , Antígenos/análisis , Artritis Reumatoide/sangre , Artritis Reumatoide/genética , Mejilla , Estudios de Evaluación como Asunto , Humanos , Persona de Mediana Edad , Mucosa Bucal/análisis , Linaje , Saliva/análisis
12.
Rev Rhum Mal Osteoartic ; 57(3 ( Pt 2)): 287-91, 1990 Apr 10.
Artículo en Francés | MEDLINE | ID: mdl-1971455

RESUMEN

Fifteen patients with rheumatoid arthritis were treated with tiopronine, and an immunological check-up carried out before the onset and after a two-month treatment. The latex test titres decreased, and there was a significant fall in the levels of IgA-containing circulating immune complexes, in parallel with a depletion of plasma complement breakdown products. Patients displayed a decrease in CD8+T cells and in CD4+Leu 8-T cells and a high proportion of activated T lymphocytes. This returned to normal after treatment. Treatment with TP led also to a reduction of adherence and chemotaxis of polymorphonuclear cells.


Asunto(s)
Artritis Reumatoide/tratamiento farmacológico , Tiopronina/uso terapéutico , Adulto , Anciano , Artritis Reumatoide/inmunología , Autacoides/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neutrófilos/inmunología , Linfocitos T/inmunología , Tiopronina/farmacología
13.
Int J Card Imaging ; 5(2-3): 213-24, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2230298

RESUMEN

In theory, radiographic myocardial perfusion imaging allows a quantitative assessment of the functional significance of a coronary stenosis. However, in the conventional two-dimensional projection images there does not exist a one-two-one relationship between a selected myocardial region of interest (ROI) and one particular coronary segment perfusing that area due to over-projection of myocardial regions in front of and behind the selected ROI perfused by other arterial segments, which may result in measurements which are difficult to interpret or even unreliable. To overcome these problems, we have developed two algorithms to determine the spatial distribution of perfusion levels in slices of the heart, selected approximately perpendicular to the left ventricular long axis, from two orthogonal angiographic views: the Segmental Reconstruction Technique (SRT) and the Network Programming Reconstruction Technique (NPRT). Both techniques require a priori geometric information about the myocardium, which can be obtained from the epicardial coronary tree (epicardial boundaries) and the left ventricular lumen (endocardial boundaries). Using the SRT approach, pie-shaped segments are defined for each slice within the myocardial geometric constraints such that superimposition of these segments when projected in orthogonal biplane views is minimal. The reconstruction process uses a model with identical myocardial geometry and definition of segments. Each segment of the model is assigned a relative perfusion level with unit one if no other a priori information is available. In this case, the model contains geometric information only. In case a priori information about expected segmental perfusion levels is available, a level between zero and one is assigned to each segment. The a priori information on the myocardial perfusion levels can be extracted from either anatomic information about the location and severity of existing coronary arterial obstructions, or from a slice adjacent to the one under reconstruction. Using the NPRT approach perfusion levels are computed for each volume picture element of a slice within the reconstructed myocardial geometry, thus resulting in a much higher spatial resolution than the SRT approach. A priori information of perfusion levels must be included in this approach, again based upon anatomical information, or upon the slice adjacent to the one under reconstruction. The very first slice of a myocardial study will be reconstructed by the SRT approach. Extensive computer simulations for the SRT have proved that the mean difference between the actual and reconstructed segmental perfusion levels, on a scale from 0 to 1, is smaller than 0.45 (SEE = 0.0033, REE = 1.80) for various coronary artery disease states without the use of a priori information on expected perfusion levels. This error becomes smaller than 0.36 (SEE = 0.0026, REE = 1.42), if a priori information in the reconstruction technique is included. Similar computer simulations for the NPRT have proved that these mean differences in geometric segments equal to those defined for the SRT, are smaller than 2.94 (SEE = 0.0308, REE = 0.77) on a scale from 0 to 16, without the use of a priori information on expected perfusion levels, and smaller than 1.72 (SEE = 0.0304, REE = 1.10) on the same scale when a priori information is included. Therefore, it may be concluded that slice-wise three-dimensional reconstruction of perfusion levels is feasible from biplane computer-simulated data, and that a similarity exists for mean perfusion levels in corresponding regions in the simulated and reconstructed slices, for various states of single coronary artery disease.


Asunto(s)
Circulación Coronaria , Corazón/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Corazón/fisiología , Modelos Cardiovasculares
14.
Int J Card Imaging ; 3(2-3): 141-52, 1988.
Artículo en Inglés | MEDLINE | ID: mdl-3171240

RESUMEN

The assessment of coronary flow reserve from the instantaneous distribution of the contrast agent within the coronary vessels and myocardial muscle at the control state and at maximal flow has been limited by the superimposition of myocardial regions of interest in the two-dimensional images. To overcome these limitations, we are in the process of developing a three-dimensional (3D) reconstruction technique to compute the contrast distribution in cross sections of the myocardial muscle from two orthogonal cineangiograms. To limit the number of feasible solutions in the 3D-reconstruction space, the 3D-geometry of the endo- and epicardial boundaries of the myocardium must be determined. For the geometric reconstruction of the epicardium, the centerlines of the left coronary arterial tree are manually or automatically traced in the biplane views. Next, the bifurcations are detected automatically and matched in these two views, allowing a 3D-representation of the coronary tree. Finally, the circumference of the left ventricular myocardium in a selected cross section can be computed from the intersection points of this cross section with the 3D coronary tree using B-splines. For the geometric reconstruction of the left ventricular cavity, we envision to apply the elliptical approximation technique using the LV boundaries defined in the two orthogonal views, or by applying more complex 3D-reconstruction techniques including densitometry. The actual 3D-reconstruction of the contrast distribution in the myocardium is based on a linear programming technique (Transportation model) using cost coefficient matrices. Such a cost coefficient matrix must contain a maximum amount of a priori information, provided by a computer generated model and updated with actual data from the angiographic views. We have only begun to solve this complex problem. However, based on our first experimental results we expect that the linear programming approach with advanced cost coefficient matrices and computed model will lead to acceptable solutions in the 3D-reconstruction of the myocardial contrast distribution from biplane cineangiograms.


Asunto(s)
Cineangiografía , Angiografía Coronaria , Circulación Coronaria , Corazón/diagnóstico por imagen , Intensificación de Imagen Radiográfica , Densitometría , Humanos , Programación Lineal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA