Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37225288

RESUMEN

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Sistema de Registros
2.
Am J Cardiol ; 172: 73-80, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35461697

RESUMEN

Although most patients with small aortic annulus are women, there is paucity of data on the prognostic impact of small aortic prosthesis in women who underwent transcatheter aortic valve implantation (TAVI). Therefore, we aimed to evaluate the impact of small valve size on 1-year clinical outcomes after TAVI in women. The Women's INternational Transcatheter Aortic Valve Implantation is an all-women registry evaluating patients with severe aortic stenosis who underwent TAVI. Based on the size of the aortic bioprosthesis implanted, women were stratified into small (≤23 mm) and nonsmall (>23 mm) valve. The primary efficacy endpoint was the Valve Academic Research Consortium-2 composite of all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction at 1-year follow-up. Of 934 women who underwent TAVI, 388 (41.5%) received a small valve. Women with a small valve size had a lower body mass index, lower surgical risk scores, were less likely to suffer from atrial fibrillation, less often required postdilation and had a lower rate of residual aortic regurgitation grade ≥2. The occurrence of the Valve Academic Research Consortium-2 efficacy endpoint was similar between women treated with small and nonsmall valve (16.0% vs 16.3%, p = 0.881; adjusted hazard ratio 1.34, 95% confidence interval 0.90 to 2.00). Likewise, there were no significant differences in the occurrence of other secondary endpoints after multivariable adjustment. In conclusion, women with severe aortic stenosis who underwent TAVI with the implantation of a small valve bioprosthesis had similar 1-year outcomes as those receiving a nonsmall bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Humanos , Masculino , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 96(1): 198-207, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31977142

RESUMEN

BACKGROUND: The prevalence of both chronic kidney disease (CKD) and aortic stenosis (AS) increase with age. Although baseline CKD is frequent in patients undergoing transcatheter aortic valve replacement (TAVR), its significance among women is largely unknown. METHODS: Women's INternational Transcatheter Aortic Valve Implantation (WIN-TAVI) is a multinational, prospective registry of women undergoing TAVR for severe AS. We included patients with available baseline estimated glomerular filtration rate (eGFR) and completed 1-year follow-up. Patients were categorized into three groups based on their eGFR: No CKD (normal kidney function to stage 2 CKD: eGFR ≥60 ml/min/1.73 m2 ); (b) mild CKD (stage 3a CKD: eGFR = 45-59 ml/min/1.73 m2 ); and (c) moderate/severe CKD (stage ≥3b CKD: eGFR <45 ml/min/1.73 m2 ). All events were adjudicated according to the Valve Academic Research Consortium (VARC)-2 criteria. RESULT: Out of 852 women undergoing TAVR, 326 (38.3%) had no CKD, 225 (26.4%) had mild CKD, and 301 (35.3%) had moderate/severe CKD. Women with higher stage of CKD at baseline were more likely to have a history of hypertension, diabetes, atrial fibrillation, anemia, chronic lung disease, hemodialysis, prior percutaneous coronary intervention, and pacemaker implantation. After multivariate adjustment, moderate/severe CKD was associated with a greater risk of 1-year VARC-2 safety endpoints [hazard ratio (HR) 1.68, 95% confidence interval (CI): 1.10-2.60], all-cause death (HR 2.00, 95% CI: 1.03-3.90), and composite of death, myocardial infarction, stroke or life-threatening bleeding (HR 1.70, 95% CI: 1.04-2.76). There were no differences in 30-day and 1-year VARC-2 efficacy and 30-day VARC-2 safety outcomes. CONCLUSION: CKD is associated with substantial and independent risk for mortality and morbidity at 1-year follow-up in women undergoing TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Tasa de Filtración Glomerular , Humanos , Riñón/fisiopatología , Sistema de Registros , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/mortalidad , Insuficiencia Renal Crónica/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
5.
JACC Cardiovasc Interv ; 11(1): 1-12, 2018 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-29301640

RESUMEN

OBJECTIVES: This study sought to examine the safety and performance of contemporary transcatheter aortic valve replacement (TAVR) in an exclusive all-women TAVR population, and to further investigate the potential impact of female sex-specific characteristics on composite 1-year clinical outcomes. BACKGROUND: Women comprise ≥50% patients undergoing TAVR. Several data have shown the noninferiority of TAVR compared with surgical aortic valve replacement for symptomatic significant aortic stenosis, but no study so far has been specifically powered to detect differences by sex. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multinational, prospective, observational registry of women undergoing TAVR for significant aortic stenosis, across 18 sites in Europe and 1 site in the United States, between January 2013 and December 2015. The primary Valve Academic Research Consortium (VARC)-2 efficacy endpoint was a composite of mortality, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction beyond 30 days. Secondary endpoints included composite 1-year death or stroke. Predictors of 1-year outcomes were determined using Cox regression methods. RESULTS: A total of 1,019 intermediate to high-risk women, with mean age 82.5 ± 6.3 years, mean European System for Cardiac Operative Risk Evaluation (EuroSCORE) I 17.8 ± 11.7% and mean Society of Thoracic Surgeons score 8.3 ± 7.4% were enrolled. TAVR was performed via transfemoral access in 90.6% and new-generation devices were used in 42.1%. The primary VARC-2 efficacy composite endpoint occurred in 111 (10.9%) patients beyond 30 days and in 167 (16.5%) patients at 1 year. The incidence of 1-year death or stroke was 13.9% (n = 141). Death occurred in 127 (12.5%) patients and stroke in 22 (2.2%) patients. Prior coronary revascularization (hazard ratio [HR]: 1.72; 95% confidence interval [CI]: 1.17 to 2.52; p = 0.006) and EuroSCORE I (HR: 1.02; 95% CI: 1.00 to 1.04; p = 0.027) were independent predictors of the VARC-2 efficacy endpoint. Similarly, EuroSCORE I (HR: 1.02; 95% CI: 1.00 to 1.04; p = 0.013), baseline atrial fibrillation (HR: 1.58; 95% CI: 1.07 to 2.33; p = 0.022), and prior percutaneous coronary intervention (HR: 1.50; 95% CI: 1.03 to 2.19; p = 0.035) were independent predictors of 1-year death or stroke. After adjustment, no significant association was observed between history of pregnancy or any sex-specific factors and 1-year TAVR outcomes. CONCLUSIONS: Intermediate to high-risk women enrolled in this first ever all-women contemporary TAVR registry experienced a 1-year VARC-2 composite efficacy endpoint of 16.5%, with a low incidence of 1-year mortality and stroke. Prior revascularization and EuroSCORE I were independent predictors of the VARC-2 efficacy endpoint, whereas EuroSCORE I, baseline atrial fibrillation, and prior percutaneous coronary intervention were independent predictors of the 1-year death or stroke.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Europa (Continente)/epidemiología , Femenino , Humanos , Complicaciones Posoperatorias/mortalidad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos/epidemiología
6.
JACC Cardiovasc Interv ; 9(15): 1589-600, 2016 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-27491609

RESUMEN

OBJECTIVES: The study sought to examine the safety and performance of transcatheter aortic valve replacement (TAVR) using an all-female registry and to further explore the potential impact of female sex-specific characteristics on clinical outcomes after TAVR. BACKGROUND: Although women comprise 50% of patients with symptomatic severe aortic stenosis undergoing TAVR, the optimal treatment strategy remains undetermined. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multinational, prospective, observational registry of women undergoing TAVR for aortic stenosis, conducted without any external funding. The primary endpoint was the Valve Academic Research Consortium (VARC)-2 early safety endpoint at 30 days (composite of mortality, stroke, major vascular complication, life-threatening bleeding, stage 2 or 3 acute kidney injury, coronary artery obstruction, or repeat procedure for valve-related dysfunction). RESULTS: Between January 2013 and December 2015, 1,019 women were enrolled across 19 European and North American centers. The mean patient age was 82.5 ± 6.3 years, mean EuroSCORE I was 17.8 ± 11.7% and mean Society of Thoracic Surgeons score was 8.3 ± 7.4%. TAVR was performed via transfemoral access in 90.6% and new-generation devices were used in 42.1%. In more than two-thirds of cases, an Edwards SAPIEN 23 mm (Edwards Lifesciences, Irvine, California) or Medtronic CoreValve ≤26 mm (Medtronic Inc., Minneapolis, Minnesota) device was implanted. The 30-day VARC-2 composite endpoint occurred in 14.0% with 3.4% all-cause mortality, 1.3% stroke, 7.7% major vascular complications, and 4.4% VARC life-threatening bleeding. The independent predictors of the primary endpoint were age (odds ratio [OR]: 1.04; 95% confidence interval [CI]: 1.00 to 1.08), prior stroke (OR: 2.02; 95% CI: 1.07 to 3.80), left ventricular ejection fraction <30% (OR: 2.62; 95% CI: 1.07 to 6.40), new device generation (OR: 0.59; 95% CI: 0.38 to 0.91), and history of pregnancy (OR: 0.57; 95% CI: 0.37 to 0.85). CONCLUSIONS: Women enrolled in this first ever all-female TAVR registry with collection of female sex-specific baseline parameters, were at intermediate-high risk and experienced a 30-day VARC-2 composite safety endpoint of 14.0% with a low incidence of early mortality and stroke. Randomized assessment of TAVR versus surgical aortic valve replacement in intermediate risk women is warranted to determine the optimal strategy.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Distribución de Chi-Cuadrado , Europa (Continente) , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Análisis Multivariante , América del Norte , Oportunidad Relativa , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
7.
J Am Coll Cardiol ; 61(15): 1577-84, 2013 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-23433565

RESUMEN

OBJECTIVES: This study sought to collect data and evaluate the anecdotal use of transcatheter aortic valve implantation (TAVI) in pure native aortic valve regurgitation (NAVR) for patients who were deemed surgically inoperable BACKGROUND: Data and experience with TAVI in the treatment of patients with pure severe NAVR are limited. METHODS: Data on baseline patient characteristics, device and procedure parameters, echocardiographic parameters, and outcomes up to July 2012 were collected retrospectively from 14 centers that have performed TAVI for NAVR. RESULTS: A total of 43 patients underwent TAVI with the CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) at 14 centers (mean age, 75.3 ± 8.8 years; 53% female; mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), 26.9 ± 17.9%; and mean Society of Thoracic Surgeons score, 10.2 ± 5.3%). All patients had severe NAVR on echocardiography without aortic stenosis and 17 patients (39.5%) had the degree of aortic valvular calcification documented on CT or echocardiography. Vascular access was transfemoral (n = 35), subclavian (n = 4), direct aortic (n = 3), and carotid (n = 1). Implantation of a TAVI was performed in 42 patients (97.7%), and 8 patients (18.6%) required a second valve during the index procedure for residual aortic regurgitation. In all patients requiring second valves, valvular calcification was absent (p = 0.014). Post-procedure aortic regurgitation grade I or lower was present in 34 patients (79.1%). At 30 days, the major stroke incidence was 4.7%, and the all-cause mortality rate was 9.3%. At 12 months, the all-cause mortality rate was 21.4% (6 of 28 patients). CONCLUSIONS: This registry analysis demonstrates the feasibility and potential procedure difficulties when using TAVI for severe NAVR. Acceptable results may be achieved in carefully selected patients who are deemed too high risk for conventional surgery, but the possibility of requiring 2 valves and leaving residual aortic regurgitation remain important considerations.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias/epidemiología , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Calcinosis , Ecocardiografía/métodos , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Humanos , Cuidados Intraoperatorios/métodos , Cuidados Intraoperatorios/estadística & datos numéricos , Masculino , Diseño de Prótesis , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos , Ajuste de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...