1.
Phys Med Biol ; 68(2)2023 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-36595327

RESUMEN

Objective.Mapping of dose delivery in proton beam therapy can potentially be performed by analyzing thermoacoustic emissions measured by ultrasound arrays. Here, a method is derived and demonstrated for spatial mapping of thermoacoustic sources using numerical time reversal, simulating re-transmission of measured emissions into the medium.Approach.Spatial distributions of thermoacoustic emission sources are shown to be approximated by the analytic-signal form of the time-reversed acoustic field, evaluated at the time of the initial proton pulse. Given calibration of the array sensitivity and knowledge of tissue properties, this approach approximately reconstructs the acoustic source amplitude, equal to the product of the time derivative of the radiation dose rate, mass density, and Grüneisen parameter. This approach was implemented using two models for acoustic fields of the array elements, one modeling elements as line sources and the other as rectangular radiators. Thermoacoustic source reconstructions employed previously reported measurements of emissions from proton energy deposition in tissue-mimicking phantoms. For a phantom incorporating a bone layer, reconstructions accounted for the higher sound speed in bone. Dependence of reconstruction quality on array aperture size and signal-to-noise ratio was consistent with previous acoustic simulation studies.Main results.Thermoacoustic source distributions were successfully reconstructed from acoustic emissions measured by a linear ultrasound array. Spatial resolution of reconstructions was significantly improved in the azimuthal (array) direction by incorporation of array element diffraction. Source localization agreed well with Monte Carlo simulations of energy deposition, and was improved by incorporating effects of inhomogeneous sound speed.Significance.The presented numerical time reversal approach reconstructs thermoacoustic sources from proton beam radiation, based on straightforward processing of acoustic emissions measured by ultrasound arrays. This approach may be useful for ranging and dosimetry of clinical proton beams, if acoustic emissions of sufficient amplitude and bandwidth can be generated by therapeutic proton sources.


Asunto(s)
Terapia de Protones , Protones , Terapia de Protones/métodos , Acústica , Sonido , Radiación Ionizante , Fantasmas de Imagen , Método de Montecarlo
2.
J Neurosci Methods ; 382: 109728, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36244524

RESUMEN

BACKGROUND: A device for moving the head during MR imaging, called a Weighted Head Accelerator Mechanism (WHAM), rotates the head of a supine subject within programmable rotation limits and acceleration profiles. The WHAM can be used with custom MRI sequences to visualize the deformation and recoil of in vivo brain parenchyma with high temporal resolution, allowing element-wise calculation of strain and shear forces in the brain. Unlike previous devices, the WHAM can be configured to provide a wide range of motion and acceleration profiles. NEW METHOD: The WHAM was calibrated using a high-speed camera on a laboratory bench and in 1.5 Tesla and 3.0 Tesla MRI scanners using gel phantoms and human subjects. The MR imaging studies employed a spatial spin-saturation tagging sub-sequence, followed by serial image acquisition. In these studies, 256 images were acquired with a temporal resolution of 2.56 ms. Deformation of the brain was quantified by following the spatial tags in the images. RESULTS: MR imaging showed that the WHAM drove quantifiable brain motions using g forces less than those typically observed in day-to-day activities, with peak accelerations of ∼250 rad/sec2. COMPARISON WITH EXISTING METHODS: The peak pre-contact accelerations and velocities achieved by the WHAM device in this study are both higher than devices used in previous studies, while also allowing for modification of these factors. CONCLUSIONS: MR imaging performed with the WHAM provides a direct method to visualize and quantify "brain slosh" in response to rotational acceleration. Consequently, this approach might find utility in evaluating strategies to protect the brain from mild traumatic brain injury (mTBI).


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Cabeza , Aceleración , Reología
3.
Magn Reson Med ; 87(6): 2885-2900, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35142398

RESUMEN

PURPOSE: Develop a deflectable intracardiac MR imaging (ICMRI) guiding-sheath to accelerate imaging during MR-guided electrophysiological (EP) interventions for radiofrequency (500 kHz) ablation (RFA) of arrythmia. Requirements include imaging at three to five times surface-coil SNR in cardiac chambers, vascular insertion, steerable-active-navigation into cardiac chambers, operation with ablation catheters, and safe levels of MR-induced heating. METHODS: ICMRI's 6 mm outer-diameter (OD) metallic-braided shaft had a 2.6 mm OD internal lumen for ablation-catheter insertion. Miniature-Baluns (MBaluns) on ICMRI's 1 m shaft reduced body-coil-induced heating. Distal section was a folded "star"-shaped imaging-coil mounted on an expandable frame, with an integrated miniature low-noise-amplifier overcoming cable losses. A handle-activated movable-shaft expanded imaging-coil to 35 mm OD for imaging within cardiac-chambers. Four MR-tracking micro-coils enabled navigation and motion-compensation, assuming a tetrahedron-shape when expanded. A second handle-lever enabled distal-tip deflection. ICMRI with a protruding deflectable EP catheter were used for MR-tracked navigation and RFA using a dedicated 3D-slicer user-interface. ICMRI was tested at 3T and 1.5T in swine to evaluate (a) heating, (b) cardiac-chamber access, (c) imaging field-of-view and SNR, and (d) intraprocedural RFA lesion monitoring. RESULTS: The 3T and 1.5T imaging SNR demonstrated >400% SNR boost over a 4 × 4 × 4 cm3 FOV in the heart, relative to body and spine arrays. ICMRI with MBaluns met ASTM/IEC heating limits during navigation. Tip-deflection allowed navigating ICMRI and EP catheter into atria and ventricles. Acute-lesion long-inversion-time-T1-weighted 3D-imaging (TWILITE) ablation-monitoring using ICMRI required 5:30 min, half the time needed with surface arrays alone. CONCLUSION: ICMRI assisted EP-catheter navigation to difficult targets and accelerated RFA monitoring.


Asunto(s)
Ablación por Catéter , Imagen por Resonancia Magnética , Animales , Arritmias Cardíacas , Ablación por Catéter/métodos , Diseño de Equipo , Atrios Cardíacos , Imagen por Resonancia Magnética/métodos , Porcinos
4.
PLoS One ; 16(8): e0256460, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34411195

RESUMEN

Computational fluid dynamics (CFD) simulations of respiratory airflow have the potential to change the clinical assessment of regional airway function in health and disease, in pulmonary medicine and otolaryngology. For example, in diseases where multiple sites of airway obstruction occur, such as obstructive sleep apnea (OSA), CFD simulations can identify which sites of obstruction contribute most to airway resistance and may therefore be candidate sites for airway surgery. The main barrier to clinical uptake of respiratory CFD to date has been the difficulty in validating CFD results against a clinical gold standard. Invasive instrumentation of the upper airway to measure respiratory airflow velocity or pressure can disrupt the airflow and alter the subject's natural breathing patterns. Therefore, in this study, we instead propose phase contrast (PC) velocimetry magnetic resonance imaging (MRI) of inhaled hyperpolarized 129Xe gas as a non-invasive reference to which airflow velocities calculated via CFD can be compared. To that end, we performed subject-specific CFD simulations in airway models derived from 1H MRI, and using respiratory flowrate measurements acquired synchronously with MRI. Airflow velocity vectors calculated by CFD simulations were then qualitatively and quantitatively compared to velocity maps derived from PC velocimetry MRI of inhaled hyperpolarized 129Xe gas. The results show both techniques produce similar spatial distributions of high velocity regions in the anterior-posterior and foot-head directions, indicating good qualitative agreement. Statistically significant correlations and low Bland-Altman bias between the local velocity values produced by the two techniques indicates quantitative agreement. This preliminary in vivo comparison of respiratory airway CFD and PC MRI of hyperpolarized 129Xe gas demonstrates the feasibility of PC MRI as a technique to validate respiratory CFD and forms the basis for further comprehensive validation studies. This study is therefore a first step in the pathway towards clinical adoption of respiratory CFD.


Asunto(s)
Isótopos de Xenón , Humanos , Hidrodinámica , Imagen por Resonancia Magnética , Tráquea
5.
Radiographics ; 41(4): E138-E139, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34197248

RESUMEN

The Society for Magnetic Resonance Angiography (SMRA) is a group of researchers and clinicians who are passionate about the benefits of MR angiography (MRA) but understand its challenges. Their mission is to study MRA, continually improve and innovate for the benefit of patients, and most important, educate the medical community so they can take full advantage of the benefits of MRA and overcome its challenges. In support of that mission, the authors have created a series of self-learning modules on behalf of the SMRA to demystify MRA protocols and help the reader perform patient-friendly high-quality MRA on a routine basis in clinical practice. The full digital presentation is available online. ©RSNA, 2021.


Asunto(s)
Medios de Contraste , Angiografía por Resonancia Magnética , Angiografía de Substracción Digital , Humanos , Sensibilidad y Especificidad
6.
Magn Reson Med ; 85(3): 1552-1560, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32936497

RESUMEN

PURPOSE: To design a new 2D gradient recalled echo MR elastography (MRE) pulse sequence with inflow saturation for measuring liver stiffness in half the breath-hold time compared to standard of care (SC) 2D GRE MRE sequences. METHODS: FASTWALTZ (fusing acceleration and saturation techniques with wave amplitude labeling of time-shifted zeniths) MRE employs an interleaved dual TR strategy with wave amplitude labeling and compressed SENSE undersampling to reduce breath-hold time while incorporating inflow saturation to suppress flow artifacts. The sequence was implemented and compared with SC MRE both in phantoms and in vivo in 5 asymptomatic volunteers. Stiffness values, region of interest size, and breath-hold times were compared between sequences. RESULTS: Stiffness values were comparable between FASTWALTZ and SC MRE for both phantoms and in-vivo data. In volunteers, the group mean stiffness values at 60 Hz and region of interest size were 1.96 ± 0.30 kilopascals and 2279 ± 516 mm2 for SC MRE, and 1.95 ± 0.29 kilopascals and 2061 ± 464 mm2 for FASTWALTZ. Breath-hold duration for FASTWALTZ was 6.3 s compared to 13.3 s for SC MRE. CONCLUSION: FASTWALTZ provides comparable stiffness values in half the breath-hold time compared to SC MRE and may have clinical benefits in patients with limited breath-holding capacity.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Aceleración , Imagen Eco-Planar , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
7.
IEEE Robot Autom Lett ; 5(4): 5245-5251, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33748414

RESUMEN

This paper reports the improved design, system integration, and initial experimental evaluation of a fully actuated body-mounted robotic system for real-time MRI-guided lower back pain injections. The 6-DOF robot is composed of a 4-DOF needle alignment module and a 2-DOF remotely actuated needle driver module, which together provide a fully actuated manipulator that can operate inside the scanner bore during imaging. The system minimizes the need to move the patient in and out of the scanner during a procedure, and thus may shorten the procedure time and streamline the clinical workflow. The robot is devised with a compact and lightweight structure that can be attached directly to the patient's lower back via straps. This approach minimizes the effect of patient motion by allowing the robot to move with the patient. The robot is integrated with an image-based surgical planning module. A dedicated clinical workflow is proposed for robot-assisted lower back pain injections under real-time MRI guidance. Targeting accuracy of the system was evaluated with a real-time MRI-guided phantom study, demonstrating the mean absolute errors (MAE) of the tip position to be 1.50±0.68mm and of the needle angle to be 1.56±0.93°. An initial cadaver study was performed to validate the feasibility of the clinical workflow, indicating the maximum error of the position to be less than 1.90mm and of the angle to be less than 3.14°.

8.
IEEE Trans Med Robot Bionics ; 2(4): 557-560, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33778433

RESUMEN

This paper reports the development and initial cadaveric evaluation of a robotic framework for MRI-guided interventions using a body-mounted approach. The framework is developed based on modular design principles. The framework consists of a body-mounted needle placement manipulator, robot control software, robot controller, interventional planning workstation, and MRI scanner. The framework is modular in the sense that all components are connected independently, making it readily extensible and reconfigurable for supporting the clinical workflow of various interventional MRI procedures. Based on this framework we developed two body-mounted robots for musculoskeletal procedures. The first robot is a four-degree of freedom system called ArthroBot for shoulder arthrography in pediatric patients. The second robot is a six-degree of freedom system called PainBot for perineural injections used to treat pain in adult and pediatric patients. Body-mounted robots are designed with compact and lightweight structure so that they can be attached directly to the patient, which minimizes the effect of patient motion by allowing the robot to move with the patient. A dedicated clinical workflow is proposed for the MRI-guided musculoskeletal procedures using body-mounted robots. Initial cadaveric evaluations of both systems were performed to verify the feasibility of the systems and validate the clinical workflow.

9.
IEEE Trans Biomed Eng ; 67(6): 1616-1627, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31535979

RESUMEN

OBJECTIVE: Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). METHOD: MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. RESULTS: Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. CONCLUSION: MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE: MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Animales , Catéteres , Electrofisiología , Diseño de Equipo , Fantasmas de Imagen , Porcinos
10.
Magn Reson Med ; 82(1): 367-376, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30847967

RESUMEN

PURPOSE: Hyperpolarized (HP) media enable biomedical imaging applications that cannot be achieved with conventional MRI contrast agents. Unfortunately, quantifying HP images is challenging, because relaxation and radio-frequency pulsing generate spatially varying signal decay during acquisition. We demonstrate that, by combining center-out k-space sampling with postacquisition keyhole reconstruction, voxel-by-voxel maps of regional HP magnetization decay can be generated with no additional data collection. THEORY AND METHODS: Digital phantom, HP 129 Xe phantom, and in vivo 129 Xe human (N = 4 healthy; N = 2 with cystic fibrosis) imaging was performed using radial sampling. Datasets were reconstructed using a postacquisition keyhole approach in which 2 temporally resolved images were created and used to generate maps of regional magnetization decay following a simple analytical model. RESULTS: Mean, keyhole-derived decay terms showed excellent agreement with the decay used in simulations (R2 = 0.996) and with global attenuation terms in HP 129 Xe phantom imaging (R2 > 0.97). Mean regional decay from in vivo imaging agreed well with global decay values and displayed spatial heterogeneity that matched expected variations in flip angle and oxygen partial pressure. Moreover, these maps could be used to correct variable signal decay across the image volume. CONCLUSIONS: We have demonstrated that center-out trajectories combined with keyhole reconstruction can be used to map regional HP signal decay and to quantitatively correct images. This approach may be used to improve the accuracy of quantitative measures obtained from hyperpolarized media. Although validated with gaseous HP 129 Xe in this work, this technique can be generalized to any hyperpolarized agent.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adolescente , Adulto , Niño , Preescolar , Medios de Contraste , Fibrosis Quística/diagnóstico por imagen , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Fantasmas de Imagen , Isótopos de Xenón
11.
Magn Reson Imaging Clin N Am ; 27(2): 341-371, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30910102

RESUMEN

Pediatric musculoskeletal tumors comprise approximately 10% of childhood neoplasms, and MR imaging has been used as the imaging evaluation standard for these tumors. The role of MR imaging in these cases includes identification of tumor origin, tissue characterization, and definition of tumor extent and relationship to adjacent structures as well as therapeutic response in posttreatment surveillance. Technical advances have enabled quantitative evaluation of biochemical changes in tumors. This article reviews recent updates to MR imaging of pediatric musculoskeletal tumors, focusing on advanced MR imaging techniques and providing information on the relevant physics of these techniques, clinical applications, and pitfalls.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Adolescente , Niño , Preescolar , Femenino , Humanos , Masculino , Sistema Musculoesquelético/diagnóstico por imagen
12.
Clin Biomech (Bristol, Avon) ; 66: 88-96, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-29079097

RESUMEN

BACKGROUND: Computational fluid dynamics simulations of respiratory airflow in the upper airway reveal clinically relevant information, including sites of local resistance, inhaled particle deposition, and the effect of pathological constrictions. Unlike previous simulations, which have been performed on rigid anatomical models from static medical imaging, this work utilises ciné imaging during respiration to create dynamic models and more closely represent airway physiology. METHODS: Airway movement maps were obtained from non-rigid image registration of fast-cine MRI and applied to high-spatial-resolution airway surface models. Breathing flowrates were recorded simultaneously with imaging. These data formed the boundary conditions for large eddy simulation computations of the airflow from exterior mask to bronchi. Simulations with rigid geometries were performed to demonstrate the resulting airflow differences between airflow simulations in rigid and dynamic airways. FINDINGS: In the analysed rapid breathing manoeuvre, incorporating airway movement significantly changed the findings of the CFD simulations. Peak resistance increased by 19.8% and occurred earlier in the breath. Overall pressure loss decreased by 19.2%, and the proportion of flow in the mouth increased by 13.0%. Airway wall motion was out-of-phase with the air pressure force, demonstrating the presence of neuromuscular motion. In total, the anatomy did 25.2% more work on the air than vice versa. INTERPRETATIONS: Realistic movement of the airway is incorporated into CFD simulations of airflow in the upper airway for the first time. This motion is vital to producing clinically relevant computational models of respiratory airflow and will allow novel analysis of dynamic conditions, such as sleep apnoea.


Asunto(s)
Hidrodinámica , Pulmón/fisiopatología , Movimiento , Respiración , Tráquea/fisiopatología , Adulto , Simulación por Computador , Humanos , Imagen por Resonancia Magnética , Masculino , Modelos Anatómicos , Modelos Biológicos , Movimiento (Física)
13.
J Magn Reson Imaging ; 50(2): 391-396, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30584687

RESUMEN

BACKGROUND: Magnetic resonance elastography (MRE) has proven to be useful for assessing chronic liver disease. However, MRE images are acquired with breath-holding (BH) to limit respiratory motion artifacts, which may be difficult in some patients. PURPOSE: To implement a respiratory-triggered (RT) spin-echo echo-planar imaging (SE-EPI) MRE technique and to validate its performance through comparison to a BH SE-EPI MRE technique. STUDY TYPE: Prospective feasibility study. SUBJECTS: Twenty-three adult volunteers (18 without and 5 with liver disease). FIELD STRENGTH/SEQUENCES: 1.5 T Philips Ingenia MR scanner; RT and BH SE-EPI MRE sequences. ASSESSMENT: Four axial images were obtained through the middle of the liver with each technique. Liver stiffness measurements (in kPa) were made from elastograms, with 95% confidence maps overlaid, for both MRE sequences. STATISTICAL TESTS: Liver stiffness measurements were compared using the paired t-test (two-sided). Absolute agreement between the two techniques was evaluated using Lin's concordance coefficient (rc ). Bland-Altman analysis was used to assess the mean bias between the techniques and 95% limits of agreement, using BH MRE as the reference standard. RESULTS: There was excellent agreement (rc = 0.98; 95% confidence interval: 0.96-0.99) between RT and BH SE-EPI MRE. Mean (±SD) stiffness values from BH and RT SE-EPI MRE techniques were 2.40 ± 1.15 kPa and 2.37 ± 1.06 kPa, respectively, with no significant difference (P = 0.54) and no significant bias (mean bias of +0.03 kPa; 95% limits of agreement: -0.39 to 0.45 kPa). Measurable regions of interest in the liver were slightly smaller with the RT technique (mean difference of 1.91 cm2 ; P = 0.04). DATA CONCLUSION: RT SE-EPI MRE is feasible and yields comparable results to BH SE-EPI MRE. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:391-396.


Asunto(s)
Imagen Eco-Planar/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Hepatopatías/diagnóstico por imagen , Hígado/diagnóstico por imagen , Adulto , Artefactos , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estudios Prospectivos , Reproducibilidad de los Resultados , Respiración , Adulto Joven
14.
Int J Numer Method Biomed Eng ; 34(12): e3144, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30133165

RESUMEN

Computational fluid dynamics (CFD) simulations of airflow in the human airways have the potential to provide a great deal of information that can aid clinicians in case management and surgical decision making, such as airway resistance, energy expenditure, airflow distribution, heat and moisture transfer, and particle deposition, as well as the change in each of these due to surgical interventions. However, the clinical relevance of CFD simulations has been limited to date, as previous models either did not incorporate neuromuscular motion or any motion at all. Many common airway pathologies, such as obstructive sleep apnea (OSA) and tracheomalacia, involve large movements of the structures surrounding the airway, such as the tongue and soft palate. Airway wall motion may be due to many factors including neuromuscular motion, internal aerodynamic forces, and external forces such as gravity. Therefore, to realistically model these airway diseases, a method is required to derive the airway wall motion, whatever the cause, and apply it as a boundary condition to CFD simulations. This paper presents and validates a novel method of capturing in vivo motion of airway walls from magnetic resonance images with high spatiotemporal resolution, through a novel combination of non-rigid image, surface, and surface-normal-vector registration. Coupled with image-synchronous pneumotachography, this technique provides the necessary boundary conditions for dynamic CFD simulations of breathing, allowing the effect of the airway's complex motion to be calculated for the first time, in both normal subjects and those with conditions such as OSA.


Asunto(s)
Simulación por Computador , Imagen por Resonancia Magnética , Modelos Biológicos , Movimiento , Sistema Respiratorio , Apnea Obstructiva del Sueño , Adulto , Niño , Humanos , Masculino , Mecánica Respiratoria , Sistema Respiratorio/diagnóstico por imagen , Sistema Respiratorio/fisiopatología , Apnea Obstructiva del Sueño/diagnóstico por imagen , Apnea Obstructiva del Sueño/fisiopatología
15.
Int J Radiat Oncol Biol Phys ; 99(3): 618-626, 2017 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-28843373

RESUMEN

PURPOSE: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. METHODS AND MATERIALS: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. RESULTS: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. CONCLUSIONS: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de los Genitales Femeninos/radioterapia , Imagen por Resonancia Magnética Intervencional/instrumentación , Radioterapia Guiada por Imagen/métodos , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/métodos , Catéteres , Femenino , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Neoplasias de los Genitales Femeninos/patología , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Radioterapia Guiada por Imagen/instrumentación
16.
Pediatr Radiol ; 47(8): 1001-1011, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28470389

RESUMEN

With its soft-tissue definition, multiplanar capabilities and advanced imaging techniques, magnetic resonance imaging (MRI) for neonatal care can provide better understanding of pathology, allowing for improved care and counseling to families. However, MR imaging in neonates is often difficult due to patient instability and the complex support necessary for survival. In our institution, we have installed a small footprint magnet in the neonatal intensive care unit (NICU) to minimize patient risks and provide the ability to perform MR imaging safely in this population. With this system, we have been able to provide more information with regard to central nervous system disorders, abdominal pathology, and pulmonary and airway abnormalities, and have performed postmortem imaging as an alternative or supplement to pathological autopsy. In our experience, an MR scanner situated within the NICU has allowed for safer and more expedited imaging of this vulnerable population.


Asunto(s)
Enfermedades del Recién Nacido/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Femenino , Humanos , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Masculino
17.
Nano Lett ; 17(4): 2532-2538, 2017 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-28287747

RESUMEN

High-intensity focused ultrasound (HIFU) has gained increasing popularity as a noninvasive therapeutic procedure to treat solid tumors. However, collateral damage due to the use of high acoustic powers during HIFU procedures remains a challenge. The objective of this study is to assess the utility of using gold nanoparticles (gNPs) during HIFU procedures to locally enhance heating at low powers, thereby reducing the likelihood of collateral damage. Phantoms containing tissue-mimicking material (TMM) and physiologically relevant concentrations (0%, 0.0625%, and 0.125%) of gNPs were fabricated. Sonications at acoustic powers of 10, 15, and 20 W were performed for a duration of 16 s using an MR-HIFU system. Temperature rises and lesion volumes were calculated and compared for phantoms with and without gNPs. For an acoustic power of 10 W, the maximum temperature rise increased by 32% and 43% for gNPs concentrations of 0.0625% and 0.125%, respectively, when compared to the 0% gNPs concentration. For the power of 15 W, a lesion volume of 0, 44.5 ± 7, and 63.4 ± 32 mm3 was calculated for the gNPs concentration of 0%, 0.0625%, and 0.125%, respectively. For a power of 20 W, it was found that the lesion volume doubled and tripled for concentrations of 0.0625% and 0.125% gNPs, respectively, when compared to the concentration of 0% gNPs. We conclude that gNPs have the potential to locally enhance the heating and reduce damage to healthy tissue during tumor ablation using HIFU.


Asunto(s)
Oro/química , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Hipertermia Inducida , Nanopartículas del Metal/química , Acústica , Algoritmos , Simulación por Computador , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias/terapia , Tamaño de la Partícula , Fantasmas de Imagen , Propiedades de Superficie , Temperatura
18.
JPEN J Parenter Enteral Nutr ; 41(8): 1386-1392, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-27503934

RESUMEN

BACKGROUND: Establishing postnatal nutrition delivery is challenging in neonates with immature sucking and swallowing ability. Enteral feeding is the gold standard for such patients, but their small size and fragility present challenges in nasogastric (NG) feeding tube placement. Feeding tubes are typically placed with x-ray guidance, which provides minimal soft tissue contrast and exposes the baby to ionizing radiation. This research investigates magnetic resonance (MR) guidance of NG feeding tube placement in neonates to provide improved soft tissue visualization without ionizing radiation. MATERIALS AND METHODS: A novel feeding tube incorporating 3 solenoid coils for real-time tracking and guidance in the MR environment was developed. The feeding tube was placed 5 times in a rabbit with conventional x-ray guidance to assess mechanical stability and function. After x-ray procedures, the rabbit was transferred to a neonatal MR system, and the tube was placed 5 more times. RESULTS: In procedures guided by x-ray and MR, the feeding tube provided sufficient mechanical strength and functionality to access the esophagus and stomach of the rabbit. MR imaging provided significantly improved soft tissue contrast versus x-ray, which aided in proper tube guidance. Moreover, MR guidance allowed for real-time placement of the tube without the use of ionizing radiation. CONCLUSIONS: The feasibility and benefits offered by an MR-guided approach to NG feeding tube placement were demonstrated. The ability to acquire high-quality MR images of soft tissue without ionizing radiation and a contrast agent, coupled with accurate 3-dimensional device tracking, promises to have a powerful impact on future neonatal feeding tube placements.


Asunto(s)
Nutrición Enteral , Intubación Gastrointestinal/métodos , Animales , Animales Recién Nacidos , Modelos Animales de Enfermedad , Esófago/diagnóstico por imagen , Estudios de Factibilidad , Imagen por Resonancia Magnética , Masculino , Conejos , Estómago/diagnóstico por imagen
19.
Magn Reson Imaging ; 34(3): 289-97, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26612078

RESUMEN

OBJECTIVE: To examine whether a centroid peak detection algorithm and micro-transmit tracking improve the accuracy and precision of active-MR tracking when combined with previously published strategies of Hadamard Multiplexing and Phase-field Dithering. MATERIALS AND METHODS: The dipole magnetic field of a solenoid tracking coil was modeled and MR spin excitation using both a uniform body coil and the tracking coil was simulated for 5329 orientations of the solenoid coil with respect to B0. A lumenless micro-coil was built onto a rotation platform and MR-tracking accuracy and precision were experimentally assessed for 576 orientations within a 1.5-T MRI scanner. Peak identification strategies (i.e. maximum pixel detection and the centroid pixel method) and transmit modes (body transmit and micro-transmit tracking) were employed and localization accuracy was assessed for each orientation in both simulation and experimentation. RESULTS: The simultaneous use of the centroid pixel method, micro-transmit tracking, Phase-field Dithering, and Hadamard Multiplexing resulted in high MR tracking accuracy and precision: 0.52±0.41 mm and 0.34 mm respectively. Furthermore, all four methods combined offered a tracking error less than the size of the micro-coil, despite the lack of a signal source within the micro-coil. CONCLUSIONS: Micro-transmit tracking and the centroid pixel method improve MR tracking accuracy and precision when combined with Phase-field Dithering and Hadamard Multiplexing compared to using Phase-field Dithering and Hadamard Multiplexing alone.


Asunto(s)
Imagen por Resonancia Magnética Intervencional/instrumentación , Imagen por Resonancia Magnética Intervencional/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Algoritmos , Radiación Electromagnética , Diseño de Equipo , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador , Campos Magnéticos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Programas Informáticos
20.
Magn Reson Med ; 75(5): 2204-16, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26101951

RESUMEN

PURPOSE: To restore 12-lead electrocardiographic (ECG) signal fidelity inside MRI by removing magnetic field gradient-induced voltages during high gradient duty cycle sequences. THEORY AND METHODS: A theoretical equation was derived to provide first- and second-order electrical fields induced at individual ECG electrodes as a function of gradient fields. Experiments were performed at 3T on healthy volunteers using a customized acquisition system that captured the full amplitude and frequency response of ECGs, or a commercial recording system. The 19 equation coefficients were derived via linear regression of data from accelerated sequences and were used to compute induced voltages in real-time during full resolution sequences to remove ECG artifacts. Restored traces were evaluated relative to ones acquired without imaging. RESULTS: Measured induced voltages were 0.7 V peak-to-peak during balanced steady state free precession (bSSFP) with the heart at the isocenter. Applying the equation during gradient echo sequencing, three-dimensional fast spin echo, and multislice bSSFP imaging restored nonsaturated traces and second-order concomitant terms showed larger contributions in electrodes further from the magnet isocenter. Equation coefficients are evaluated with high repeatability (ρ = 0.996) and are dependent on subject, sequence, and slice orientation. CONCLUSION: Close agreement between theoretical and measured gradient-induced voltages allowed for real-time removal. Prospective estimation of sequence periods in which large induced voltages occur may allow hardware removal of these signals.


Asunto(s)
Electrocardiografía , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Adulto , Algoritmos , Artefactos , Técnicas de Imagen Sincronizada Cardíacas , Electrodos , Voluntarios Sanos , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Reproducibilidad de los Resultados