Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Antimicrob Agents ; 42(6): 531-6, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24207018

RESUMEN

OXA-48 ß-lactamase is one of the several emerging carbapenemases. Pre-2007 reports were almost exclusively from Turkey, but subsequently its distribution has expanded. We report an early and prolonged outbreak in the UK of Klebsiella pneumoniae producing OXA-48 carbapenemase affecting a predominantly renal cohort in a West London hospital. Carbapenemase production was detected by the modified Hodge test, with confirmation by PCR for bla(OXA-48). Isolates were typed by pulsed-field gel electrophoresis (PFGE) and multilocus sequence typing (MLST). Risk factors for acquisition were determined. Between January 2008 and April 2010, 20 K. pneumoniae isolates with reduced susceptibility to carbapenems were identified from 13 patients, comprising 12 renal cases and 1 oncology patient; 8 were outpatients and 5 were inpatients; 7 were deemed to be colonised and 6 infected, including 2 with bacteraemia, 1 of whom died. Hodge tests were positive for all isolates and all had bla(OXA-48). PFGE showed strain similarity in isolates from nine patients, whereas four patients' isolates were distinct, representing three further PFGE profiles and suggesting horizontal spread of bla(OXA-48). Most patients had received antibiotics in the preceding 3 months and all had healthcare contact, but none had recent travel to areas with endemic OXA-48 Enterobacteriaceae. The renal cohort was screened and a prevalence rate of 0.17% was found. Interventions that collectively brought the outbreak under control included strict infection control precautions, screening, improved laboratory detection protocols and antibiotic stewardship rounds.


Asunto(s)
Infección Hospitalaria/epidemiología , Brotes de Enfermedades , Infecciones por Klebsiella/epidemiología , Klebsiella pneumoniae/enzimología , beta-Lactamasas/metabolismo , Infección Hospitalaria/microbiología , Electroforesis en Gel de Campo Pulsado , Genotipo , Hospitales , Humanos , Infecciones por Klebsiella/microbiología , Klebsiella pneumoniae/clasificación , Klebsiella pneumoniae/genética , Klebsiella pneumoniae/aislamiento & purificación , Londres/epidemiología , Tipificación de Secuencias Multilocus , Factores de Riesgo
2.
Nephrol Dial Transplant ; 19(11): 2816-22, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15340094

RESUMEN

BACKGROUND: Vascular access is judged on its ability to provide good dialysis adequacy, its durability and complication rates. Formation of a functional arteriovenous fistula is desirable but difficult to achieve in a significant proportion of patients. We report the large-scale use of Tesio-Caths, a twin-line single-lumen central venous catheter, to maximize dialysis adequacy where formation of an arteriovenous fistula was not possible. METHODS: All patients who had Tesio-Caths inserted between 1 January 1999 and 1 October 2002 were studied. RESULTS: Six hundred and twenty-three Tesio-Caths were inserted from 1 January 1999 to 1 October 2002 in 435 patients, generating 7464 patient months of follow-up. Five hundred and ninety-four out of 623 (95.3%) Tesio-Caths were immediately functional. Mean dialysis adequacy measured by single-pool Kt/V was 1.5+/-0.3 for all Tesio-Caths for the entire period of study, with 68% of Tesio-Caths delivering a Kt/V >1.4. Cumulative functional Tesio-Cath survival to final failure was 77.8 and 44% at 1 and 3 years, respectively. Cumulative patient survival was 84.7, 71.4 and 63% at 1, 2 and 3 years, respectively. Access-related infection accounted for 0.28 admissions/1000 catheter days, and the death rate from access-related sepsis was 9.6 deaths/1000 patient years at risk. The admission rate for access dysfunction was 0.33/1000 patient years at risk. CONCLUSION: Tesio-Caths provide good dialysis adequacy for patients in whom an arteriovenous fistula cannot be formed. Patient and functional access survival for this group was comparable with current European data irrespective of vascular access type. Complication rates were acceptably low.


Asunto(s)
Cateterismo Venoso Central , Catéteres de Permanencia , Diálisis Renal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Venoso Central/efectos adversos , Diseño de Equipo , Femenino , Humanos , Fallo Renal Crónico , Masculino , Persona de Mediana Edad , Diálisis Renal/efectos adversos , Sepsis/etiología , Sepsis/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...