Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Radiol ; 69(12): e471-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25168700

RESUMEN

AIM: To compare the complications and outcomes of Neuroform and Enterprise stents in the treatment of unruptured wide-necked aneurysms. MATERIALS AND METHODS: Under the auspices of the institutional review board, a review of a prospectively collected patient log identified 130 patients who underwent elective stent-assisted coil embolization of a wide-necked aneurysm, including 53 patients treated with an Enterprise stent and 77 patients treated with a Neuroform stent. Immediate and long-term clinical and radiographic outcomes were recorded for all patients. All patient data were handled in accordance with Health Insurance Portability and Accountability Act of 1996 (HIPAA) regulations. RESULTS: The technical success rate was 94%. Overall morbidity was 15% with Enterprise stents and 3% with Neuroform stents (p = 0.020). However, the type of stent used was not predictive of clinical outcomes as measured by the modified Rankin scale. In a multivariate analysis, the use of a Neuroform stent was one of the predictors of retreatment (p = 0.034). CONCLUSION: Multivariate analyses identified the use of Neuroform stents as an independent predictor of the need for retreatment and the use of Enterprise stents as an independent predictor of morbidity. However, the type of stent was not predictive of clinical outcome as measured by the modified Rankin scale.


Asunto(s)
Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Stents/clasificación , Stents/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital/métodos , Embolización Terapéutica/métodos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Retratamiento/estadística & datos numéricos , Stents/efectos adversos , Resultado del Tratamiento , Adulto Joven
2.
AJNR Am J Neuroradiol ; 35(11): 2140-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24994822

RESUMEN

BACKGROUND AND PURPOSE: As aneurysms arising from the ophthalmic segment of the internal carotid artery increase in size, they can compress the optic nerve, prompting patients to present with visual disturbances. The purpose of this article is to describe the clinical and angiographic results with an emphasis on visual outcomes following the endovascular treatment of ophthalmic segment ICA aneurysms. MATERIALS AND METHODS: The records of 1254 patients who presented for endovascular treatment of a cerebral aneurysm were retrospectively reviewed to identify 65 consecutive patients who underwent coil embolization of an ophthalmic segment ICA aneurysm. The clinical records, treatment reports, and imaging were reviewed with a focus on visual outcomes. RESULTS: Twenty-two of the 65 patients (34%) who presented for treatment of an ophthalmic aneurysm reported a visual disturbance at presentation. Fifteen of the 22 patients (68%) experienced an improvement in their symptoms after treatment. Overall, patients with visual symptoms were significantly more likely to benefit from treatment than to have a decline in vision (P = .03). The overall morbidity was 4%, and mortality was 0%. The retreatment rate was high at 30%, though this was disproportionately weighted by an 86% retreatment rate in patients with ruptured aneurysms. CONCLUSIONS: Patients with visual symptoms attributable to ophthalmic segment ICA aneurysms undergoing endovascular coil embolization were statistically more likely to experience an improvement in their vision than to have worsening or unchanged vision. Coiling was associated with a low morbidity rate, though an elevated retreatment rate.


Asunto(s)
Arteria Carótida Interna/cirugía , Embolización Terapéutica/efectos adversos , Procedimientos Endovasculares/efectos adversos , Aneurisma Intracraneal/terapia , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Roto/diagnóstico por imagen , Prótesis Vascular , Angiografía Cerebral , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Aneurisma Intracraneal/complicaciones , Masculino , Persona de Mediana Edad , Retratamiento , Estudios Retrospectivos , Trastornos de la Visión/etiología
3.
AJNR Am J Neuroradiol ; 35(10): 1959-64, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24904051

RESUMEN

BACKGROUND AND PURPOSE: A 4D CT protocol for detection of parathyroid lesions involves obtaining unenhanced, arterial, early, and delayed venous phase images. The aim of the study was to determine the ideal combination of phases that would minimize radiation dose without sacrificing diagnostic accuracy. MATERIALS AND METHODS: With institutional review board approval, the records of 29 patients with primary hyperparathyroidism who had undergone surgical exploration were reviewed. Four neuroradiologists who were blinded to the surgical outcome reviewed the imaging studies in 5 combinations (unenhanced and arterial phase; unenhanced, arterial, and early venous; all 4 phases; arterial alone; arterial and early venous phases) with an interval of at least 7 days between each review. The accuracy of interpretation in lateralizing an abnormality to the side of the neck (right, left, ectopic) and localizing it to a quadrant in the neck (right or left upper, right or left lower) was evaluated. RESULTS: The lateralization and localization accuracy (90.5% and 91.5%, respectively) of the arterial phase alone was comparable with the other combinations of phases. There was no statistically significant difference among the different combinations of phases in their ability to lateralize or localize adenomas to a quadrant (P = .976 and .996, respectively). CONCLUSIONS: Assessment of a small group of patients shows that adequate diagnostic accuracy for parathyroid adenoma localization may be achievable by obtaining arterial phase images alone. If this outcome can be validated prospectively in a larger group of patients, then the radiation dose can potentially be reduced to one-fourth of what would otherwise be administered.


Asunto(s)
Adenoma/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Hiperparatiroidismo Primario/diagnóstico por imagen , Neoplasias de las Paratiroides/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA