Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 40(1): 90-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24923476

RESUMEN

PURPOSE: To evaluate the effect of different methods to convert magnetic resonance (MR) signal intensity (SI) to gadolinium concentration ([Gd]) on estimation and reproducibility of model-free and modeled hepatic perfusion parameters measured with dynamic contrast-enhanced (DCE)-MRI. MATERIALS AND METHODS: In this Institutional Review Board (IRB)-approved prospective study, 23 DCE-MRI examinations of the liver were performed on 17 patients. SI was converted to [Gd] using linearity vs. nonlinearity assumptions (using spoiled gradient recalled echo [SPGR] signal equations). The [Gd] vs. time curves were analyzed using model-free parameters and a dual-input single compartment model. Perfusion parameters obtained with the two conversion methods were compared using paired Wilcoxon test. Test-retest and interobserver reproducibility of perfusion parameters were assessed in six patients. RESULTS: There were significant differences between the two conversion methods for the following parameters: AUC60 (area under the curve at 60 s, P < 0.001), peak gadolinium concentration (Cpeak, P < 0.001), upslope (P < 0.001), Fp (portal flow, P = 0.04), total hepatic flow (Ft, P = 0.007), and MTT (mean transit time, P < 0.001). Our preliminary results showed acceptable to good reproducibility for all model-free parameters for both methods (mean coefficient of variation [CV] range, 11.87-23.7%), except for upslope (CV = 37%). Among modeled parameters, DV (distribution volume) had CV <22% with both methods, PV and MTT showed CV <21% and <29% using SPGR equations, respectively. Other modeled parameters had CV >30% with both methods. CONCLUSION: Linearity assumption is acceptable for quantification of model-free hepatic perfusion parameters while the use of SPGR equations and T1 mapping may be recommended for the quantification of modeled hepatic perfusion parameters.


Asunto(s)
Algoritmos , Hepatitis C/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Hígado/fisiopatología , Angiografía por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Modelos Biológicos , Compuestos Organometálicos/farmacocinética , Anciano , Velocidad del Flujo Sanguíneo , Medios de Contraste/farmacocinética , Femenino , Hepatitis C/patología , Humanos , Hígado/patología , Circulación Hepática , Masculino , Meglumina/farmacocinética , Tasa de Depuración Metabólica , Persona de Mediana Edad , Modelos Estadísticos , Dinámicas no Lineales , Variaciones Dependientes del Observador , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...