1.
J Appl Clin Med Phys ; : e14386, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739330

RESUMEN

PURPOSE: Photon counting CT (PCCT) holds promise for mitigating metal artifacts and can produce virtual mono-energetic images (VMI), while maintaining temporal resolution, making it a valuable tool for characterizing the heart. This study aimed to evaluate and optimize PCCT for cardiac imaging in patients during left ventricular assistance device (LVAD) therapy by conducting an in-depth objective assessment of metal artifacts and visual grading. METHODS: Various scan and reconstruction settings were tested on a phantom and further evaluated on a patient acquisition to identify the optimal protocol settings. The phantom comprised an empty thoracic cavity, supplemented with heart and lungs from a cadaveric lamb. The heart was implanted with an LVAD (HeartMate 3) and iodine contrast. Scans were performed on a PCCT (NAEOTOM Alpha, Siemens Healthcare). Metal artifacts were assessed by three objective methods: Hounsfield units (HU)/SD measurements (DiffHU and SDARTIFACT), Fourier analysis (AmplitudeLowFreq), and depicted LVAD volume in the images (BloomVol). Radiologists graded metal artifacts and the diagnostic interpretability in the LVAD lumen, cardiac tissue, lung tissue, and spinal cord using a 5-point rating scale. Regression and correlation analysis were conducted to determine the assessment method most closely associated with acquisition and reconstruction parameters, as well as the objective method demonstrating the highest correlation with visual grading. RESULTS: Due to blooming artifacts, the LVAD volume fluctuated between 27.0 and 92.7 cm3. This variance was primarily influenced by kVp, kernel, keV, and iMAR (R2 = 0.989). Radiologists favored pacemaker iMAR, 3 mm slice thickness, and T3D keV and kernel Bv56f for minimal metal artifacts in cardiac tissue assessment, and 110 keV and Qr40f for lung tissue interpretation. The model adequacy for DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was 0.28, 0.76, 0.29, and 0.99 respectively for phantom data, and 0.95, 0.98, 1.00, and 0.99 for in-vivo data. For in-vivo data, the correlation between visual grading (VGSUM) and DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was -0.16, -0.01, -0.48, and -0.40 respectively. CONCLUSION: We found that optimal scan settings for LVAD imaging involved using 120 kVp and IQ level 80. Employing T3D with pacemaker iMAR, the sharpest allowed vascular kernel (Bv56f), and VMI at 110 keV with kernel Qr40 yields images suitable for cardiac imaging during LVAD-therapy. Volumetric measurements of the LVAD for determination of the extent of blooming artifacts was shown to be the best objective method to assess metal artifacts.

3.
ESC Heart Fail ; 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520314

RESUMEN

AIMS: While echocardiography remains essential within haemodynamic monitoring of durable mechanical circulatory support, previous echocardiographic guidelines are missing scientific evidence for the novel HeartMate 3™ (HM3) system. Accordingly, this review aims to summarize available echocardiographic evidence including HM3. METHODS AND RESULTS: This systematic review adhered to the PRISMA 2020 guidelines. Searches were conducted during August 2023 across PubMed, Embase, and Google Scholar using specific echocardiographic terms combined with system identifiers. Study quality was assessed using the Newcastle-Ottawa Scale (NOS) for cohort studies and Critical Appraisal Instrument (PCAI) for cross-sectional studies. Nine studies met the inclusion criteria, of which eight cohort studies and one cross-sectional study. Aortic regurgitation (AR) prevalence at approximately 12 months of support exhibited heterogenicity (33.5% (Δ 33%)) in a limited number of studies (n = 3). Several studies (n = 5) demonstrated an increasing prevalence and severity of AR during HM3 support, generating moderate to high level of evidence. One AR study showed a higher cumulative incidence of death and heart failure (HF) readmission compared with those without significant AR, hazard ratio 3.42 (95% CI 1.48-8.76). A second study showed that a worsening AR group had significantly lower survival-free from HF readmission (59% vs. 89%, P = 0.023) with a hazard ratio of 5.18 (95% CI 1.07-25.0), while a third study did not reveal any differences in cardiac-related hospitalizations in the 12 months follow-up or non-cardiac-related hospitalization. Mitral regurgitation (MR) prevalence at approximately 12 months of support exhibited good consistency 15.0% (Δ 0.8%) in both included studies, which did not reveal any significant pattern of changing prevalence over time. Tricuspid regurgitation (TR) prevalence at approximately 12 months of support exhibited fair consistency 28.5% (Δ 8.3%) in a limited number of studies (n = 2); both studies showed a statistically un-confirmed trend of increased TR prevalence over time. The evidence of general prevalence of right ventricular dysfunction (RVD) was insufficient due to lack of studies. CONCLUSIONS: There are few methodologically consistent studies with focus on long-term haemodynamic effects. Aortic regurgitation still seems to be a prevalent and potentially significant finding. The available evidence concerning right heart function is limited despite clinical relevance and potential prognostic value. Potential interventricular and haemodynamic interplay are identified as a white field for future research.

4.
J Cardiovasc Magn Reson ; 26(1): 101042, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38556134

RESUMEN

BACKGROUND: Diastolic left ventricular (LV) dysfunction is a powerful contributor to the symptoms and prognosis of patients with heart failure. In patients with depressed LV systolic function, the E/A ratio, the ratio between the peak early (E) and the peak late (A) transmitral flow velocity, is the first step to defining the grade of diastolic dysfunction. Doppler echocardiography (echo) is the preferred imaging technique for diastolic function assessment, while cardiovascular magnetic resonance (CMR) is less established as a method. Previous four-dimensional (4D) Flow-based studies have looked at the E/A ratio proximal to the mitral valve, requiring manual interaction. In this study, we compare an automated, deep learning-based and two semi-automated approaches for 4D Flow CMR-based E/A ratio assessment to conventional, gold-standard echo-based methods. METHODS: Ninety-seven subjects with chronic ischemic heart disease underwent a cardiac echo followed by CMR investigation. 4D Flow-based E/A ratio values were computed using three different approaches; two semi-automated, assessing the E/A ratio by measuring the inflow velocity (MVvel) and the inflow volume (MVflow) at the mitral valve plane, and one fully automated, creating a full LV segmentation using a deep learning-based method with which the E/A ratio could be assessed without constraint to the mitral plane (LVvel). RESULTS: MVvel, MVflow, and LVvel E/A ratios were strongly associated with echocardiographically derived E/A ratio (R2 = 0.60, 0.58, 0.72). LVvel peak E and A showed moderate association to Echo peak E and A, while MVvel values were weakly associated. MVvel and MVflow EA ratios were very strongly associated with LVvel (R2 = 0.84, 0.86). MVvel peak E was moderately associated with LVvel, while peak A showed a strong association (R2 = 0.26, 0.57). CONCLUSION: Peak E, peak A, and E/A ratio are integral to the assessment of diastolic dysfunction and may expand the utility of CMR studies in patients with cardiovascular disease. While underestimation of absolute peak E and A velocities was noted, the E/A ratio measured with all three 4D Flow methods was strongly associated with the gold standard Doppler echocardiography. The automatic, deep learning-based method performed best, with the most favorable runtime of ∼40 seconds. As both semi-automatic methods associated very strongly to LVvel, they could be employed as an alternative for estimation of E/A ratio.

5.
Eur J Vasc Endovasc Surg ; 67(3): 506-513, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37777048

RESUMEN

OBJECTIVE: Abdominal aortic aneurysm (AAA) is commonly defined as localised aortic dilatation with a diameter > 30 mm. The pathophysiology of AAA includes chronic inflammation and enzymatic degradation of elastin, possibly increasing aortic wall stiffness and pulse wave velocity (PWV). Whether aortic stiffness is more prominent in the abdominal aorta at the aneurysm site is not elucidated. The aim of this study was to evaluate global and regional aortic PWV in patients with AAA. METHODS: Experimental study of local PWV in the thoracic descending and abdominal aorta in patients with AAA and matched controls. The study cohort comprised 25 patients with an AAA > 30 mm (range 36 - 70 mm, all male, age range 65 - 76 years) and 27 age and sex matched controls free of AAA. PWV was measured with applanation tonometry (carotid-femoral PWV, cfPWV) as well as a 4D flow MRI technique, assessing regional aortic PWV. Blood pressure and anthropometrics were measured. RESULTS: Global aortic PWV was greater in men with an AAA than controls, both by MRI (AAA 8.9 ± 2.4 m/s vs. controls 7.1 ± 1.5 m/s; p = .007) and cfPWV (AAA 11.0 ± 2.1 m/s vs. controls 9.3 ± 2.3 m/s; p = .007). Regionally, PWV was greater in the abdominal aorta in the AAA group (AAA 7.0 ± 1.8 m/s vs. controls 5.8 ± 1.0 m/s; p = .022), but similar in the thoracic descending aorta (AAA 8.7 ± 3.2 m/s vs. controls 8.2 ± 2.4 m/s; p = .59). Furthermore, PWV was positively associated with indices of central adiposity both in men with AAA and controls. CONCLUSION: PWV is higher in men with AAA compared with matched controls in the abdominal but not the thoracic descending aorta. Furthermore, aortic stiffness was linked with central fat deposition. It remains to be seen whether there is a causal link between AAA and increased regional aortic stiffness.


Asunto(s)
Aneurisma de la Aorta Abdominal , Rigidez Vascular , Humanos , Masculino , Anciano , Femenino , Análisis de la Onda del Pulso , Aneurisma de la Aorta Abdominal/cirugía , Aorta Abdominal , Aorta Torácica , Imagen por Resonancia Magnética
6.
Am J Physiol Heart Circ Physiol ; 326(3): H511-H521, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38133621

RESUMEN

Left atrial (LA) blood flow plays an important role in diseases such as atrial fibrillation (AF) and atrial cardiomyopathy since alterations in the blood flow might lead to thrombus formation and stroke. Using traditional techniques, such as echocardiography, atrial flow velocities can be measured at the pulmonary veins and the mitral valve, but a comprehensive understanding of the three-dimensional atrial flow field is missing. Previously, ventricular flow has been analyzed using flow component analysis, revealing new insights into ventricular flow and function. Thus, the aim of this project was to develop a comprehensive flow component analysis method for the LA and explore its utility in 21 patients with paroxysmal atrial fibrillation compared with a control group of 8 participants. The flow field was derived from time-resolved CT acquired during sinus rhythm using computational fluid dynamics. Flow components were computed from particle tracking. We identified six atrial flow components: conduit, reservoir, delayed ejection, retained inflow, residual volume, and pulmonary vein backflow. It was shown that conduit flow, defined as blood entering and leaving the LA within the same diastolic phase, exists in most subjects. Although the volume of conduit and reservoir is similar in patients with paroxysmal AF in sinus rhythm and controls, the volume of the other components is increased in paroxysmal AF. Comprehensive quantification of LA flow using flow component analysis makes atrial blood flow quantifiable, thus facilitating investigation of mechanisms underlying atrial dysfunction and can increase understanding of atrial blood flow in disease progression and stroke risk.NEW & NOTEWORTHY We developed a new comprehensive approach to atrial blood component analysis that includes both conduit flow and residual volume and compared the flow components of atrial fibrillation (AF) patients in sinus rhythm with controls. Conduit and reservoir flow were similar between the groups, whereas components with longer residence time in the left atrium were increased in the AF group. This could add to the pathophysiological understanding of atrial diseases and possibly clinical management.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Ecocardiografía , Hemodinámica
8.
Front Cardiovasc Med ; 10: 1219021, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37649669

RESUMEN

Introduction: Atrial fibrillation (AF) is associated with an increased risk of stroke, often caused by thrombi that form in the left atrium (LA), and especially in the left atrial appendage (LAA). The underlying mechanism is not fully understood but is thought to be related to stagnant blood flow, which might be present despite sinus rhythm. However, measuring blood flow and stasis in the LAA is challenging due to its small size and low velocities. We aimed to compare the blood flow and stasis in the left atrium of paroxysmal AF patients with controls using computational fluid dynamics (CFD) simulations. Methods: The CFD simulations were based on time-resolved computed tomography including the patient-specific cardiac motion. The pipeline allowed for analysis of 21 patients with paroxysmal AF and 8 controls. Stasis was estimated by computing the blood residence time. Results and Discussion: Residence time was elevated in the AF group (p < 0.001). Linear regression analysis revealed that stasis was strongest associated with LA ejection ratio (p < 0.001, R2 = 0.68) and the ratio of LA volume and left ventricular stroke volume (p < 0.001, R2 = 0.81). Stroke risk due to LA thrombi could already be elevated in AF patients during sinus rhythm. In the future, patient specific CFD simulations may add to the assessment of this risk and support diagnosis and treatment.

9.
J Physiol ; 601(17): 3765-3787, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37485733

RESUMEN

Type 2 diabetes (T2D) and hypertension increase the risk of cardiovascular diseases mediated by whole-body changes to metabolism, cardiovascular structure and haemodynamics. The haemodynamic changes related to hypertension and T2D are complex and subject-specific, however, and not fully understood. We aimed to investigate the haemodynamic mechanisms in T2D and hypertension by comparing the haemodynamics between healthy controls and subjects with T2D, hypertension, or both. For all subjects, we combined 4D flow magnetic resonance imaging data, brachial blood pressure and a cardiovascular mathematical model to create a comprehensive subject-specific analysis of central haemodynamics. When comparing the subject-specific haemodynamic parameters between the four groups, the predominant haemodynamic difference is impaired left ventricular relaxation in subjects with both T2D and hypertension compared to subjects with only T2D, only hypertension and controls. The impaired relaxation indicates that, in this cohort, the long-term changes in haemodynamic load of co-existing T2D and hypertension cause diastolic dysfunction demonstrable at rest, whereas either disease on its own does not. However, through subject-specific predictions of impaired relaxation, we show that altered relaxation alone is not enough to explain the subject-specific and group-related differences; instead, a combination of parameters is affected in T2D and hypertension. These results confirm previous studies that reported more adverse effects from the combination of T2D and hypertension compared to either disease on its own. Furthermore, this shows the potential of personalized cardiovascular models in providing haemodynamic mechanistic insights and subject-specific predictions that could aid in the understanding and treatment planning of patients with T2D and hypertension. KEY POINTS: The combination of 4D flow magnetic resonance imaging data and a cardiovascular mathematical model allows for a comprehensive analysis of subject-specific haemodynamic parameters that otherwise cannot be derived non-invasively. Using this combination, we show that diastolic dysfunction in subjects with both type 2 diabetes (T2D) and hypertension is the main group-level difference between controls, subjects with T2D, subjects with hypertension, and subjects with both T2D and hypertension. These results suggest that, in this relatively healthy population, the additional load of both hypertension and T2D affects the haemodynamic function of the left ventricle, whereas each disease on its own is not enough to cause significant effects under resting conditions. Finally, using the subject-specific model, we show that the haemodynamic effects of diastolic dysfunction alone are not sufficient to explain all the observed haemodynamic differences. Instead, additional subject-specific variations in cardiac and vascular function combine to explain the complex haemodynamics of subjects affected by hypertension and/or T2D.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipertensión , Humanos , Modelos Cardiovasculares , Hemodinámica , Imagen por Resonancia Magnética , Ventrículos Cardíacos
10.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-37474977

RESUMEN

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Asunto(s)
Sistema Cardiovascular , Humanos , Velocidad del Flujo Sanguíneo , Valor Predictivo de las Pruebas , Corazón , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
11.
Front Cardiovasc Med ; 10: 1103751, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37025678

RESUMEN

The total kinetic energy (KE) of blood can be decomposed into mean KE (MKE) and turbulent KE (TKE), which are associated with the phase-averaged fluid velocity field and the instantaneous velocity fluctuations, respectively. The aim of this study was to explore the effects of pharmacologically induced stress on MKE and TKE in the left ventricle (LV) in a cohort of healthy volunteers. 4D Flow MRI data were acquired in eleven subjects at rest and after dobutamine infusion, at a heart rate that was ∼60% higher than the one in rest conditions. MKE and TKE were computed as volume integrals over the whole LV and as data mapped to functional LV flow components, i.e., direct flow, retained inflow, delayed ejection flow and residual volume. Diastolic MKE and TKE increased under stress, in particular at peak early filling and peak atrial contraction. Augmented LV inotropy and cardiac frequency also caused an increase in direct flow and retained inflow MKE and TKE. However, the TKE/KE ratio remained comparable between rest and stress conditions, suggesting that LV intracavitary fluid dynamics can adapt to stress conditions without altering the TKE to KE balance of the normal left ventricle at rest.

13.
Commun Med (Lond) ; 3(1): 22, 2023 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-36774374

RESUMEN

BACKGROUND: Cardiac time-resolved CT (4D-CT) acquisitions provide high quality anatomical images of the heart. However, some cardiac diseases require assessment of blood flow in the heart. Diastolic dysfunction, for instance, is diagnosed by measuring the flow through the mitral valve (MV), while in atrial fibrillation, the flow through the left atrial appendage (LAA) indicates the risk for thrombus formation. Accurate validated techniques to extract this information from 4D-CT have been lacking, however. METHODS: To measure the flow rate though the MV and the LAA from 4D-CT, we developed a motion tracking algorithm that performs a nonrigid deformation of the surface separating the blood pool from the myocardium. To improve the tracking of the LAA, this region was deformed separately from the left atrium and left ventricle. We compared the CT based flow with 4D flow and short axis MRI data from the same individual in 9 patients. RESULTS: For the mitral valve flow, good agreement was found for the time span between the early and late diastolic peak flow (bias: <0.1 s). The ventricular stroke volume is similar compared to short-axis MRI (bias 3 ml). There are larger differences in the diastolic peak flow rates, with a larger bias for the early flow rate than the late flow rate. The peak LAA outflow rate measured with both modalities matches well (bias: -6 ml/s). CONCLUSIONS: Overall, the developed algorithm provides accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA compared to 4D flow MRI.


Assessing the blood flow inside the heart is important in diagnosis and treatment of various cardiovascular diseases, such as atrial fibrillation or heart failure. We developed a method to accurately track the motion of the heart walls over the course of a heartbeat in three-dimensional Computed Tomography (CT) images. Based on the motion, we calculated the amount of blood passing through the mitral valve and the left atrial appendage orifice, which are markers used in the diagnostic of heart failure and assessment of stroke risk in atrial fibrillation. The results agreed well with measurements from 4D flow MRI, an imaging technique that measures blood velocities. Our method could broaden the use of CT and make additional exams redundant. It can even be used to calculate the blood flow inside the heart.

14.
Clin Anat ; 36(3): 542-549, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36695446

RESUMEN

Difficulties in achieving knowledge about physiology and anatomy of the beating heart highlight the challenges with more traditional pedagogical methods. Recent research regarding anatomy education has mainly focused on digital three-dimensional models. However, these pedagogical improvements may not be entirely applicable to cardiac anatomy and physiology due to the multidimensional complexity with moving anatomy and complex blood flow. The aim of this study was therefore to evaluate whether high quality time-resolved anatomical images combined with realistic blood flow simulations improve the understanding of cardiac structures and function. Three time-resolved datasets were acquired using time-resolved computed tomography and blood flow was computed using Computational Fluid Dynamics. The anatomical and blood flow information was combined and interactively visualized using volume rendering on an advanced stereo projection system. The setup was tested in interactive lectures for medical students. Ninety-seven students participated. Summative assessment of examinations showed significantly improved mean score (18.1 ± 4.5 vs 20.3 ± 4.9, p = 0.002). This improvement was driven by knowledge regarding myocardial hypertrophy and pressure-velocity differences over a stenotic valve. Additionally, a supplementary formative assessment showed significantly more agreeing answers than disagreeing answers (p < 0.001) when the participants subjectively evaluated the contribution of the visualizations to their education and knowledge. In conclusion, the use of simultaneous visualization of time-resolved anatomy data and simulated blood flow improved medical students' results, with a particular effect on understanding of cardiac physiology and these simulations may be useful educational tools for teaching complex anatomical and physiological concepts.


Asunto(s)
Anatomía , Educación de Pregrado en Medicina , Fisiología , Estudiantes de Medicina , Humanos , Educación de Pregrado en Medicina/métodos , Evaluación Educacional , Tomografía Computarizada por Rayos X , Hemodinámica , Anatomía/educación , Curriculum , Fisiología/educación
15.
J Cardiovasc Magn Reson ; 25(1): 5, 2023 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-36717885

RESUMEN

BACKGROUND: Decisions in the management of aortic stenosis are based on the peak pressure drop, captured by Doppler echocardiography, whereas gold standard catheterization measurements assess the net pressure drop but are limited by associated risks. The relationship between these two measurements, peak and net pressure drop, is dictated by the pressure recovery along the ascending aorta which is mainly caused by turbulence energy dissipation. Currently, pressure recovery is considered to occur within the first 40-50 mm distally from the aortic valve, albeit there is inconsistency across interventionist centers on where/how to position the catheter to capture the net pressure drop. METHODS: We developed a non-invasive method to assess the pressure recovery distance based on blood flow momentum via 4D Flow cardiovascular magnetic resonance (CMR). Multi-center acquisitions included physical flow phantoms with different stenotic valve configurations to validate this method, first against reference measurements and then against turbulent energy dissipation (respectively n = 8 and n = 28 acquisitions) and to investigate the relationship between peak and net pressure drops. Finally, we explored the potential errors of cardiac catheterisation pressure recordings as a result of neglecting the pressure recovery distance in a clinical bicuspid aortic valve (BAV) cohort of n = 32 patients. RESULTS: In-vitro assessment of pressure recovery distance based on flow momentum achieved an average error of 1.8 ± 8.4 mm when compared to reference pressure sensors in the first phantom workbench. The momentum pressure recovery distance and the turbulent energy dissipation distance showed no statistical difference (mean difference of 2.8 ± 5.4 mm, R2 = 0.93) in the second phantom workbench. A linear correlation was observed between peak and net pressure drops, however, with strong dependences on the valvular morphology. Finally, in the BAV cohort the pressure recovery distance was 78.8 ± 34.3 mm from vena contracta, which is significantly longer than currently accepted in clinical practise (40-50 mm), and 37.5% of patients displayed a pressure recovery distance beyond the end of the ascending aorta. CONCLUSION: The non-invasive assessment of the distance to pressure recovery is possible by tracking momentum via 4D Flow CMR. Recovery is not always complete at the ascending aorta, and catheterised recordings will overestimate the net pressure drop in those situations. There is a need to re-evaluate the methods that characterise the haemodynamic burden caused by aortic stenosis as currently clinically accepted pressure recovery distance is an underestimation.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Valor Predictivo de las Pruebas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Válvula Aórtica/diagnóstico por imagen , Hemodinámica , Espectroscopía de Resonancia Magnética , Velocidad del Flujo Sanguíneo/fisiología
16.
J Magn Reson Imaging ; 57(1): 191-203, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35506525

RESUMEN

BACKGROUND: Segmenting the whole heart over the cardiac cycle in 4D flow MRI is a challenging and time-consuming process, as there is considerable motion and limited contrast between blood and tissue. PURPOSE: To develop and evaluate a deep learning-based segmentation method to automatically segment the cardiac chambers and great thoracic vessels from 4D flow MRI. STUDY TYPE: Retrospective. SUBJECTS: A total of 205 subjects, including 40 healthy volunteers and 165 patients with a variety of cardiac disorders were included. Data were randomly divided into training (n = 144), validation (n = 20), and testing (n = 41) sets. FIELD STRENGTH/SEQUENCE: A 3 T/time-resolved velocity encoded 3D gradient echo sequence (4D flow MRI). ASSESSMENT: A 3D neural network based on the U-net architecture was trained to segment the four cardiac chambers, aorta, and pulmonary artery. The segmentations generated were compared to manually corrected atlas-based segmentations. End-diastolic (ED) and end-systolic (ES) volumes of the four cardiac chambers were calculated for both segmentations. STATISTICAL TESTS: Dice score, Hausdorff distance, average surface distance, sensitivity, precision, and miss rate were used to measure segmentation accuracy. Bland-Altman analysis was used to evaluate agreement between volumetric parameters. RESULTS: The following evaluation metrics were computed: mean Dice score (0.908 ± 0.023) (mean ± SD), Hausdorff distance (1.253 ± 0.293 mm), average surface distance (0.466 ± 0.136 mm), sensitivity (0.907 ± 0.032), precision (0.913 ± 0.028), and miss rate (0.093 ± 0.032). Bland-Altman analyses showed good agreement between volumetric parameters for all chambers. Limits of agreement as percentage of mean chamber volume (LoA%), left ventricular: 9.3%, 13.5%, left atrial: 12.4%, 16.9%, right ventricular: 9.9%, 15.6%, and right atrial: 18.7%, 14.4%; for ED and ES, respectively. DATA CONCLUSION: The addition of this technique to the 4D flow MRI assessment pipeline could expedite and improve the utility of this type of acquisition in the clinical setting. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Fibrilación Atrial , Aprendizaje Profundo , Humanos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Corazón/diagnóstico por imagen
17.
Front Cardiovasc Med ; 9: 949440, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35966533

RESUMEN

Background: Myocardial infarction (MI) is a major cause of heart failure. Left ventricular adverse remodeling is common post-MI. Several studies have demonstrated a correlation between reduced myocardial strain and the development of adverse remodeling. Cardiac magnetic resonance (CMR) with fast-strain encoding (fast-SENC) or feature tracking (FT) enables rapid assessment of myocardial deformation. The aim of this study was to establish a head-to-head comparison of fast-SENC and FT in post-ST-elevated myocardial infarction (STEMI) patients, with clinical 2D speckle tracking echocardiography (2DEcho) as a reference. Methods: Thirty patients treated with primary percutaneous coronary intervention for STEMI were investigated. All participants underwent CMR examination with late gadolinium enhancement, cine-loop steady-state free precession, and fast-SENC imaging using a 1.5T scanner as well as a 2DEcho. Global longitudinal strain (GLS), segmental longitudinal strain (SLS), global circumferential strain (GCS), and segmental circumferential strain (SCS) were assessed along with the MI scar extent. Results: The GCS measurements from fast-SENC and FT were nearly identical: the mean difference was 0.01 (2.5)% (95% CI - 0.92 to 0.95). For GLS, fast-SENC values were higher than FT, with a mean difference of 1.8 (1.4)% (95% CI 1.31-2.35). Tests of significance for GLS did not show any differences between the MR methods and 2DEcho. Average strain in the infarct-related artery (IRA) segments compared to the remote myocardium was significantly lower for the left anterior descending artery and right coronary artery culprits but not for the left circumflex artery culprits. Fast-SENC displayed a higher area under the curve for detecting infarcted segments than FT for both SCS and SLS. Conclusion: GLS and GCS did not significantly differ between fast-SENC and FT. Both showed acceptable agreement with 2DEcho for longitudinal strain. Segments perfused by the IRA showed significantly reduced strain values compared to the remote myocardium. Fast-SENC presented a higher sensitivity and specificity for detecting infarcted segments than FT.

18.
Front Cardiovasc Med ; 9: 813427, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35966535

RESUMEN

Background: Different regional depots of fat have distinct metabolic properties and may relate differently to adverse cardiac remodeling. We sought to quantify regional depots of body fat and to investigate their relationship to cardiac structure and function in Type 2 Diabetes (T2D) and controls. Methods: From the SCAPIS cohort in Linköping, Sweden, we recruited 92 subjects (35% female, mean age 59.5 ± 4.6 years): 46 with T2D and 46 matched controls. In addition to the core SCAPIS data collection, participants underwent a comprehensive magnetic resonance imaging examination at 1.5 T for assessment of left ventricular (LV) structure and function (end-diastolic volume, mass, concentricity, ejection fraction), as well as regional body composition (liver proton density fat fraction, visceral adipose tissue, abdominal subcutaneous adipose tissue, thigh muscle fat infiltration, fat tissue-free thigh muscle volume and epicardial adipose tissue). Results: Compared to the control group, the T2D group had increased: visceral adipose tissue volume index (P < 0.001), liver fat percentage (P < 0.001), thigh muscle fat infiltration percentage (P = 0.02), LV concentricity (P < 0.001) and LV E/e'-ratio (P < 0.001). In a multiple linear regression analysis, a negative association between liver fat percentage and LV mass (St Beta -0.23, P < 0.05) as well as LV end-diastolic volume (St Beta -0.27, P < 0.05) was found. Epicardial adipose tissue volume and abdominal subcutaneous adipose tissue volume index were the only parameters of fat associated with LV diastolic dysfunction (E/e'-ratio) (St Beta 0.24, P < 0.05; St Beta 0.34, P < 0.01, respectively). In a multivariate logistic regression analysis, only visceral adipose tissue volume index was significantly associated with T2D, with an odds ratio for T2D of 3.01 (95% CI 1.28-7.05, P < 0.05) per L/m2 increase in visceral adipose tissue volume. Conclusions: Ectopic fat is predominantly associated with cardiac remodeling, independently of type 2 diabetes. Intriguingly, liver fat appears to be related to LV structure independently of VAT, while epicardial fat is linked to impaired LV diastolic function. Visceral fat is associated with T2D independently of liver fat and abdominal subcutaneous adipose tissue.

19.
Front Cardiovasc Med ; 9: 866131, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35935619

RESUMEN

Left ventricular diastolic dysfunction is a major cause of heart failure and carries a poor prognosis. Assessment of left ventricular diastolic function however remains challenging for both echocardiography and conventional phase contrast cardiac magnetic resonance. Amongst other limitations, both are restricted to measuring velocity in a single direction or plane, thereby compromising their ability to capture complex diastolic hemodynamics in health and disease. Time-resolved three-dimensional phase contrast cardiac magnetic resonance imaging with three-directional velocity encoding known as '4D flow CMR' is an emerging technology which allows retrospective measurement of velocity and by extension flow at any point in the acquired 3D data volume. With 4D flow CMR, complex aspects of blood flow and ventricular function can be studied throughout the cardiac cycle. 4D flow CMR can facilitate the visualization of functional blood flow components and flow vortices as well as the quantification of novel hemodynamic and functional parameters such as kinetic energy, relative pressure, energy loss and vorticity. In this review, we examine key concepts and novel markers of diastolic function obtained by flow pattern analysis using 4D flow CMR. We consolidate the existing evidence base to highlight the strengths and limitations of 4D flow CMR techniques in the surveillance and diagnosis of left ventricular diastolic dysfunction.

20.
Front Physiol ; 13: 869701, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35694404

RESUMEN

Introduction: The blood flow in the normal cardiovascular system is predominately laminar but operates close to the threshold to turbulence. Morphological distortions such as vascular and valvular stenosis can cause transition into turbulent blood flow, which in turn may cause damage to tissues in the cardiovascular system. A growing number of studies have used magnetic resonance imaging (MRI) to estimate the extent and degree of turbulent flow in different cardiovascular diseases. However, the way in which heart rate and inotropy affect turbulent flow has not been investigated. In this study we hypothesized that dobutamine stress would result in higher turbulence intensity in the healthy thoracic aorta. Method: 4D flow MRI data were acquired in twelve healthy subjects at rest and with dobutamine, which was infused until the heart rate increased by 60% when compared to rest. A semi-automatic segmentation method was used to segment the thoracic aorta in the 4D flow MR images. Subsequently, flow velocity and several turbulent kinetic energy (TKE) parameters were calculated in the ascending aorta, aortic arch, descending aorta and whole thoracic aorta. Results: With dobutamine infusion there was an increase in heart rate (66 ± 9 vs. 108 ± 13 bpm, p < 0.001) and stroke volume (88 ± 13 vs. 102 ± 25 ml, p < 0.01). Additionally, there was an increase in Peak Average velocity (0.7 ± 0.1 vs. 1.2 ± 0.2 m/s, p < 0.001, Peak Max velocity (1.3 ± 0.1 vs. 2.0 ± 0.2 m/s, p < 0.001), Peak Total TKE (2.9 ± 0.7 vs. 8.0 ± 2.2 mJ, p < 0.001), Peak Median TKE (36 ± 7 vs. 93 ± 24 J/m3, p = 0.002) and Peak Max TKE (176 ± 33 vs. 334 ± 69 J/m3, p < 0.001). The relation between cardiac output and Peak Total TKE in the whole thoracic aorta was very strong (R2 = 0.90, p < 0.001). Conclusion: TKE of blood flow in the healthy thoracic aorta increases with dobutamine stress and is strongly related to cardiac output. Quantification of such turbulence intensity parameters with cardiac stress may serve as a risk assessment of aortic disease development.

SELECCIÓN DE REFERENCIAS