Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Catheter Cardiovasc Interv ; 89(3): 452-459, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27514499

RESUMEN

OBJECTIVES: The objectives of the present study were to analyze the variation of renal function after transcatheter aortic valve replacement (TAVR) focused on acute kidney injury (AKI) and its impact on short- and mid-term mortality. BACKGROUND: Changes on renal function after TAVR and their impact on clinical outcomes are incompletely understood until now. METHODS: At two tertiary centers 221 consecutive patients were submitted to TAVR. Kidney injury was defined according to VARC-2 criteria. Patients were classified according to the presence (group 1) or absence (group 2) of AKI. Creatinine values were collected daily until seventh day after procedure, 1 month, 6 months, and then 1 year after TAVR. RESULTS: At baseline, groups were similar, except for EuroSCORE II (8.66% vs. 7.34%, P = 0.02) and glomerular filtration rate (GFR) (39.59 vs. 48.49 mL/min.1.73 m2 , P = 0.002). Overall 30 day-mortality and 1-year mortality were 6.3% and 14.0%, respectively. Both 30-day mortality (23.1% vs. 1.2%, P < 0.001) and 1-year mortality (44.2% vs. 4.7%, P < 0.001) were higher in group 1. After multivariable-adjusted models, the only independent predictor for AKI after TAVR was baseline GFR (HR: 1.37, 95% CI: 1.08-1.77, P = 0.01). The independent risk factors for 1-year mortality were AKI (HR: 15.66, 95% CI: 6.07-44.63, P < 0.001), COPD (HR: 3.14, 95% CI: 1.05-9.40, P = 0.04) and aortic regurgitation grade postprocedure ≥ 2 (P = 0.05) also after multivariate analysis. CONCLUSIONS: In this TAVR cohort, baseline GFR was the only independent predictor of AKI, which negatively impacted on 30-day and 1-year mortality. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Lesión Renal Aguda/etiología , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Riñón/fisiopatología , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/mortalidad , Lesión Renal Aguda/fisiopatología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Biomarcadores/sangre , Brasil , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Distribución de Chi-Cuadrado , Creatinina/sangre , Ecocardiografía , Femenino , Tasa de Filtración Glomerular , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Centros de Atención Terciaria , Factores de Tiempo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 90(1): 139-146, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28029207

RESUMEN

OBJECTIVE: We sought to compare the new transcatheter aortic valve replacement (TAVR) device ACURATE neo (ACT) with the already established CoreValve (MCV) and SAPIEN XT (SXT) for the treatment of severe aortic stenosis (AS). BACKGROUND: Very few data on TAVR devices are available beyond MCV and SAPIEN and there is no previous study comparing ACT with MCV and SXT. METHODS: We prospectively evaluated consecutive patients who underwent transfemoral TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. RESULTS: A total of 162 patients (ACT n = 49, MCV n = 56, SXT n = 57), were included. MCV group had higher valve embolization/migration rates (ACT none; MCV 9%; SXT 2%; P = 0.034) causing lower device success rates (ACT 98%; MCV 86%; SXT 95%; P = 0.043). At 30 days, there was no significant difference in all-cause mortality (P = 0.22), cardiovascular mortality (P = 0.20), periprocedural myocardial infarction (P = 0.40), stroke (P = 0.64), major vascular complications (P = 0.48), life-threatening bleeding (P = 0.29), acute kidney injury stage 2/3 (P = 0.69), or VARC-2 composite early safety endpoints (P = 0.21). MCV group had higher rates of new permanent pacemaker implantation (ACT 6%; MCV 25%; SXT 11%; P = 0.013). Follow-up echocardiography showed no significant difference in aortic valve mean pressure gradient (P = 0.73) or moderate/severe aortic regurgitation (P = 0.19) between groups. CONCLUSIONS: In a "real world" registry, ACT compared favorably against the well-studied SXT and MCV devices in both safety and efficacy. MCV implantation was associated with lower device success rates and higher rates of new permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Grupo de Atención al Paciente , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Brasil , Femenino , Hemodinámica , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 88(6): 953-960, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27143093

RESUMEN

BACKGROUND: Alcohol septal ablation (ASA) is an alternative treatment for symptomatic hypertrophic obstructive cardiomyopathy (HOCM) patients refractory to pharmacological therapy. We sought to evaluate the immediate and long-term incidence of death and changes in life quality in a consecutive cohort submitted to ASA. METHODS AND RESULTS: Between October 1998 and December 2013, a total of 56 patients (mean age 53.2 ± 15.5) with symptomatic refractory HOCM were treated with ASA and followed during 15 years (mean 8 ± 4 years). There were 7 (12.5%) deaths, 2 (3.6%) being of cardiac cause. The Kaplan-Meier survival probability estimate was 96.4% at 1 year, 87.7 at 5 years and 81.0% at 12 years post-ASA. Significant improvement was observed in life quality assessed by DASI index and NYHA functional class as well as in the left ventricle outflow tract (LVOT) gradient reduction (from 92.8 ± 3.3 mm Hg to 9.37 ± 6.7 mm Hg, P < 0.001) and septum thickness (from 23.9 ± 0.6 mm to 12.9 ± 1.0 mm, P < 0.001). Only one patient (1.7%) required permanent pacemaker immediately after ASA. During follow-up, one patient had a repeated ASA, three patients underwent myectomy and other four required ICD/pacemaker. In the multivariate model only post-ASA LVOT residual gradient and left ventricle mass were associated with worse prognosis. CONCLUSIONS: In this long-term clinical follow-up without losses, ASA was effective in improving quality of life and NYHA functional class, with relatively low mortality and very low need for immediate permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Técnicas de Ablación/métodos , Cateterismo Cardíaco/métodos , Cardiomiopatía Hipertrófica/cirugía , Etanol/administración & dosificación , Tabiques Cardíacos , Brasil/epidemiología , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/mortalidad , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA