Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
2.
Ann Thorac Surg ; 113(6): 1935-1942, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34242640

RESUMEN

BACKGROUND: Failure to rescue (FTR) focuses on the ability to prevent death among patients who have postoperative complications. The Society of Thoracic Surgeons (STS) Quality Measurement Task Force has developed a new, risk-adjusted FTR quality metric for adult cardiac surgery. METHODS: The study population was taken from 1118 STS Adult Cardiac Surgery Database participants including patients who underwent isolated CABG, aortic valve replacement with or without CABG, or mitral valve repair or replacement with or without CABG between January 2015 and June 2019. The FTR analysis was derived from patients who had one or more of the following complications: prolonged ventilation, stroke, reoperation, and renal failure. Data were randomly split into 70% training samples (n = 89,059) and 30% validation samples (n = 38,242). Risk variables included STS predicted risk of mortality, operative procedures, and intraoperative variables (cardiopulmonary bypass and cross-clamp times, unplanned procedures, need for circulatory support, and massive transfusion). RESULTS: Overall mortality for patients undergoing any of the index operations during the study period was 2.6% (27,045 of 1,058,138), with mortality of 0.9% (8316 of 930,837), 8% (7618 of 94,918), 30.6% (8247 of 26,934), 51.9% (2661 of 5123), and 62.3% (203 of 326), respectively, among patients having none, one, two, three, or four complications. The FTR risk model calibration was excellent, as were model discrimination (c-statistic 0.806) and the Brier score (0.102). Using 95% Bayesian credible intervals, 62 participants (5.6%) performed worse and 53 (4.7%) performed better than expected. CONCLUSIONS: A new risk-adjusted FTR metric has been developed that complements existing STS performance measures. The metric specifically assesses institutional effectiveness of postoperative care, allowing hospitals to target quality improvement efforts.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cirujanos , Cirugía Torácica , Adulto , Teorema de Bayes , Causas de Muerte , Humanos , Complicaciones Posoperatorias/epidemiología , Sociedades Médicas
3.
Circulation ; 141(13): 1071-1079, 2020 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-32098500

RESUMEN

BACKGROUND: Patients with bicuspid aortic valve (AV) stenosis were excluded from the pivotal evaluations of transcatheter AV replacement (TAVR) devices. We sought to evaluate the outcomes of TAVR in patients with bicuspid AV stenosis in comparison with those with tricuspid AV stenosis. METHODS: We used data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry (November 2011 through November 2018) to determine device success, procedural outcomes, post-TAVR valve performance, and in-hospital clinical outcomes (mortality, stroke, and major bleeding) according to valve morphology (bicuspid versus tricuspid). Results were stratified by older and current (Sapien 3 and Evolut R) generation valve prostheses. Medicare administrative claims were used to evaluate mortality and stroke to 1 year among eligible individuals (≥65 years). RESULTS: After exclusions, there were 170 959 eligible procedures at 593 sites during the specified interval. Of these, 5412 TAVR procedures (3.2%) were performed in patients with bicuspid AV, including 3705 with current-generation devices. In comparison with patients with tricuspid valves, patients with bicuspid AV were younger and had a lower Society of Thoracic Surgeons Predicted Risk of Operative Mortality score. When current-generation devices were used to treat patients with bicuspid AV, device success increased (93.5 versus 96.3; P=0.001) and the incidence of 2+ aortic insufficiency declined (14.0% versus 2.7%; P<0.001) in comparison with older-generation devices. With current-generation devices, device success was slightly lower in the bicuspid (versus tricuspid) AV group (96.3% in bicuspid versus 97.4% in tricuspid, P=0.07), with a slightly higher incidence of residual moderate or severe aortic insufficiency among patients with bicuspid AV (2.7% versus 2.1%; P<0.001). A lower 1-year adjusted risk of mortality (hazard ratio, 0.88 [95% CI, 0.78-0.99]) was observed for patients with bicuspid AV versus patients with tricuspid AV in the Medicare-linked cohort, whereas no difference was observed in the 1-year adjusted risk of stroke (hazard ratio, 1.14 [95% CI, 0.94-1.39]). CONCLUSIONS: Using current-generation devices, procedural, postprocedural, and 1-year outcomes were comparable following TAVR for bicuspid AV versus tricuspid AV disease. With newer-generation devices, TAVR is a viable treatment option for patients with bicuspid AV disease.


Asunto(s)
Enfermedad de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Resultado del Tratamiento
4.
Ann Thorac Surg ; 109(4): 1243-1250, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31562839

RESUMEN

BACKGROUND: Patients undergoing post infarction ventricular septal defect repair are at high risk for early morbidity and mortality, but little is known about subsequent clinical events. This study uses short-term clinical data from The Society of Thoracic Surgeons National Database linked with Medicare data to examine longer term outcomes in these patients. METHODS: This was a retrospective review of The Society of Thoracic Surgeons National Database to link with Medicare data all adults (≥65 years) who underwent ventricular septal defect repair after a myocardial infarction between 2008 and 2012. The primary outcome was 1-year mortality. Risk factors for 1-year survival were modeled using a multivariable Cox regression. RESULTS: Five hundred thirty-seven patients were identified using The Society of Thoracic Surgeons database and Medicare linkage. Median age was 74 years, and 277 patients (52%) were men. One hundred ninety-two patients (36%) were supported preoperatively with an intraaortic balloon pump. Surgical status was emergent or salvage in 138 (26%), and 158 patients (29%) died within 30 days and 207 (39%) within 1 year. Among patients who survived to hospital discharge, 44% were discharged to a facility and 172 (32%) experienced at least 1 all-cause readmission within 1 year. Unadjusted 1-year mortality rates were 13% for elective patients and 69% for emergency status (P < .01). On multivariable analysis emergency/salvage status, older age, and concomitant coronary artery bypass grafting were independently associated with worse 1-year survival. CONCLUSIONS: These data suggest the greatest mortality risk in this patient population occurs in the first 30 days. Emergency or salvage status strongly predicts 1-year mortality. Optimizing physiologic derangements before operative repair may be considered when possible in this subgroup of patients.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Defectos del Tabique Interventricular/cirugía , Medicare/estadística & datos numéricos , Infarto del Miocardio/complicaciones , Anciano , Femenino , Estudios de Seguimiento , Defectos del Tabique Interventricular/epidemiología , Defectos del Tabique Interventricular/etiología , Humanos , Masculino , Morbilidad/tendencias , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
5.
J Am Coll Cardiol ; 73(22): 2806-2815, 2019 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-31171086

RESUMEN

BACKGROUND: In patients with end-stage renal disease (ESRD), surgical aortic valve replacement is associated with higher early and late mortality, and adverse outcomes compared with patients without renal disease. Transcatheter aortic valve replacement (TAVR) offers another alternative, but there are limited reported outcomes. OBJECTIVES: The purpose of this study was to determine the outcomes of TAVR in patients with ESRD. METHODS: Among the first 72,631 patients with severe aortic stenosis (AS) treated with TAVR enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) TVT (Transcatheter Valve Therapies) registry, 3,053 (4.2%) patients had ESRD and were compared with patients who were not on dialysis for demographics, risk factors, and outcomes. RESULTS: Compared with the nondialysis patients, ESRD patients were younger (76 years vs. 83 years; p < 0.01) and had higher rates of comorbidities leading to a higher STS predicted risk of mortality (median 13.5% vs. 6.2%; p < 0.01). ESRD patients had a higher in-hospital mortality (5.1% vs. 3.4%; p < 0.01), although the observed to expected ratio was lower (0.32 vs. 0.44; p < 0.01). ESRD patients also had a similar rate of major vascular complications (4.5% vs. 4.6%; p = 0.86), but a higher rate of major bleeding (1.4% vs. 1.0%; p = 0.03). The 1-year mortality was significantly higher in dialysis patients (36.8% vs. 18.7%; p < 0.01). CONCLUSIONS: Patients undergoing TAVR with ESRD are at higher risk and had higher in-hospital mortality and bleeding, but similar vascular complications, when compared with those who are not dialysis dependent. The 1-year survival raises concerns regarding diminished benefit in this population. TAVR should be used judiciously after full discussion of the risk-benefit ratio in patients on dialysis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fallo Renal Crónico/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Comorbilidad , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/mortalidad , Masculino , Valores de Referencia , Sistema de Registros , Diálisis Renal , Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
6.
Ann Thorac Surg ; 107(4): 1097-1103, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30529671

RESUMEN

BACKGROUND: Stroke is a serious complication after transcatheter aortic valve replacement (TAVR), yet predictive models are not available. A new risk model for in-hospital stroke after TAVR was developed and used to estimate site-specific performance. METHODS: We included 97,600 TAVR procedures from 521 sites in The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from July 2014 to June 2017. Association between baseline covariates and in-hospital stroke was estimated by logistic regression. Discrimination was evaluated by C-statistic. Calibration was tested internally via cross-validation. Hierarchical modeling was used to estimate risk-adjusted site-specific performance. RESULTS: Median age was 82 years, 44,926 (46.0%) were women, and 1,839 (1.9%) had in-hospital stroke. Covariates associated with stroke (odds ratio) included transapical access (1.44), access excluding transapical and transfemoral (1.77), prior stroke (1.57), prior transient ischemic attack (1.50), preprocedural shock, inotropes or mechanical assist device (1.48), smoking (1.28), porcelain aorta (1.23), peripheral arterial disease (1.21), age per 5 years (1.11), glomerular filtration rate per 5 mL/min (0.97), body surface area per m2 (0.55 male; 0.43 female), and prior aortic valve (0.78) and nonaortic valvular (0.42) procedures. The C-statistic was 0.622. Calibration curves demonstrated agreement between observed and expected stroke rates. Hierarchical modeling showed 10 (1.9%) centers with significantly higher odds ratios for in-hospital stroke than their peers. CONCLUSIONS: A risk model for in-hospital stroke after TAVR was developed from The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry and used to estimate site-specific stroke performance. This model can serve as a valuable resource for quality improvement, clinical decision making, and patient counseling.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Mortalidad Hospitalaria , Sistema de Registros , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Prevalencia , Reproducibilidad de los Resultados , Medición de Riesgo , Gestión de Riesgos , Sociedades Médicas , Accidente Cerebrovascular/etiología , Cirugía Torácica , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estados Unidos
7.
J Am Heart Assoc ; 7(23): e010139, 2018 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-30571598

RESUMEN

Background In older adults undergoing cardiac surgery, prediction of downstream risk is critical. Our objective was to determine the association of 5-m gait speed with 1-year mortality and repeat hospitalization following cardiac surgery. Methods and Results In this prospective cohort of patients undergoing cardiac surgery at centers participating in the Society of Thoracic Surgeons Database with gait speed recorded, we examined all-cause mortality using a landmark analysis at 0 to 30, 30 to 365, and >365 days, as well as repeat hospitalization. The cohort consisted of 8287 patients (median age, 74 years; 32% females). At 1 year, survival was 90% in the slow (<0.83 m/s), 95% in the middle (0.83-1.00 m/s), and 97% in the fast (>1.00 m/s) gait speed tertiles, and risk of hospitalization was 45%, 33%, and 27%, respectively (both P<0.0001). After adjustment, gait speed remained predictive of mortality (hazard ratio, 2.16 per 0.1-m/s decrease in gait speed; 95% confidence interval, 1.59-2.93) and rehospitalization (hazard ratio, 1.71 per 0.1-m/s decrease in gait speed; 95% confidence interval, 1.45-2.0). In a landmark analysis, the effect of slow gait speed on mortality was most marked from 30 to 365 days after surgery, where each decline in 0.1 m/s of gait speed conferred a 2-fold increased risk of mortality. Conclusions Gait speed is a simple tool to screen for frailty and identify older adults at risk for adverse events in the early and midterm postoperative periods.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Velocidad al Caminar , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Bases de Datos como Asunto , Femenino , Fragilidad/diagnóstico , Humanos , Estimación de Kaplan-Meier , Masculino , Readmisión del Paciente/estadística & datos numéricos , Modelos de Riesgos Proporcionales , Factores de Riesgo , Sociedades Médicas , Análisis de Supervivencia , Estados Unidos
8.
Circ Cardiovasc Qual Outcomes ; 11(10): e004693, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30354575

RESUMEN

Background Among clinical trial patients at high surgical risk, a model has been developed and externally validated to estimate patient risk for poor outcomes after transcatheter aortic valve replacement (TAVR). How this model performs in lower risk and unselected patients is not known. We sought to examine and optimize the performance of the TAVR poor outcome risk model among patients in the US Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Methods and Results Among 13 351 patients who underwent TAVR at 252 US sites between November 9, 2011 and June 30, 2015, the rate of poor outcome at 1 year after TAVR was 38.9%, which was because of death in 20.7% and poor quality of life or quality of life decline in 18.2%. The rate of poor outcome has decreased slightly over time, from 42.0% in 2012 to 37.8% in 2015 ( P for trend=0.076). The original TAVR poor outcome risk model did not calibrate well on this population. We then reestimated the intercept and coefficients in the model and retested model performance, after which it performed well (both overall and in subgroups), with a C index 0.65 and excellent calibration. Conclusions In a large cohort of unselected patients in the United States, we found that while a substantial minority of patients continue to have a poor outcome after TAVR, outcomes have slowly improved over time. After recalibration, the TAVR poor outcome risk model performed well. This model could potentially be used before TAVR to help patients have appropriate expectations of recovery.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Calidad de Vida , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Estado de Salud , Humanos , Masculino , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
9.
JACC Cardiovasc Interv ; 11(6): 581-589, 2018 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-29566805

RESUMEN

OBJECTIVES: The aim of this study was to develop and validate a risk adjustment model for 30-day mortality after transcatheter aortic valve replacement (TAVR) that accounted for both standard clinical factors and pre-procedural health status and frailty. BACKGROUND: Assessment of risk for TAVR is important both for patient selection and provider comparisons. Prior efforts for risk adjustment have focused on in-hospital mortality, which is easily obtainable but can be biased because of early discharge of ill patients. METHODS: Using data from patients who underwent TAVR as part of the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry (June 2013 to May 2016), a hierarchical logistic regression model to estimate risk for 30-day mortality after TAVR based only on pre-procedural factors and access site was developed and internally validated. The model included factors from the original TVT Registry in-hospital mortality model but added the Kansas City Cardiomyopathy Questionnaire (health status) and gait speed (5-m walk test). RESULTS: Among 21,661 TAVR patients at 188 sites, 1,025 (4.7%) died within 30 days. Independent predictors of 30-day death included older age, low body weight, worse renal function, peripheral artery disease, home oxygen, prior myocardial infarction, left main coronary artery disease, tricuspid regurgitation, nonfemoral access, worse baseline health status, and inability to walk. The predicted 30-day mortality risk ranged from 1.1% (lowest decile of risk) to 13.8% (highest decile of risk). The model was able to stratify risk on the basis of patient factors with good discrimination (C = 0.71 [derivation], C = 0.70 [split-sample validation]) and excellent calibration, both overall and in key patient subgroups. CONCLUSIONS: A clinical risk model was developed for 30-day death after TAVR that included clinical data as well as health status and frailty. This model will facilitate tracking outcomes over time as TAVR expands to lower risk patients and to less experienced sites and will allow an objective comparison of short-term mortality rates across centers.


Asunto(s)
Técnicas de Apoyo para la Decisión , Indicadores de Salud , Estado de Salud , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Toma de Decisiones Clínicas , Femenino , Fragilidad/diagnóstico , Fragilidad/mortalidad , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Masculino , Aptitud Física , Valor Predictivo de las Pruebas , Sistema de Registros , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Sociedades Médicas , Encuestas y Cuestionarios , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos/epidemiología , Prueba de Paso , Velocidad al Caminar
10.
Ann Thorac Surg ; 105(5): 1419-1428, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29577924

RESUMEN

BACKGROUND: The Society of Thoracic Surgeons (STS) uses statistical models to create risk-adjusted performance metrics for Adult Cardiac Surgery Database (ACSD) participants. Because of temporal changes in patient characteristics and outcomes, evolution of surgical practice, and additional risk factors available in recent ACSD versions, completely new risk models have been developed. METHODS: Using July 2011 to June 2014 ACSD data, risk models were developed for operative mortality, stroke, renal failure, prolonged ventilation, mediastinitis/deep sternal wound infection, reoperation, major morbidity or mortality composite, prolonged postoperative length of stay, and short postoperative length of stay among patients who underwent isolated coronary artery bypass grafting surgery (n = 439,092), aortic or mitral valve surgery (n = 150,150), or combined valve plus coronary artery bypass grafting surgery (n = 81,588). Separate models were developed for each procedure and endpoint except mediastinitis/deep sternal wound infection, which was analyzed in a combined model because of its infrequency. A surgeon panel selected predictors by assessing model performance and clinical face validity of full and progressively more parsimonious models. The ACSD data (July 2014 to December 2016) were used to assess model calibration and to compare discrimination with previous STS risk models. RESULTS: Calibration in the validation sample was excellent for all models except mediastinitis/deep sternal wound infection, which slightly underestimated risk and will be recalibrated in feedback reports. The c-indices of new models exceeded those of the last published STS models for all populations and endpoints except stroke in valve patients. CONCLUSIONS: New STS ACSD risk models have generally excellent calibration and discrimination and are well suited for risk adjustment of STS performance metrics.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Modelos Estadísticos , Complicaciones Posoperatorias/etiología , Medición de Riesgo , Adulto , Bases de Datos Factuales , Humanos , Sociedades Médicas , Cirugía Torácica
11.
Ann Thorac Surg ; 104(3): 731-741, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28760477

RESUMEN

The Society of Thoracic Surgeons Congenital Heart Surgery Database (STS CHSD) is the largest congenital and pediatric cardiac surgical clinical data registry in the world. It contains data pertaining to more than 435,000 total operations. The most recent biannual feedback report to participants (Spring 2017, Report of the Twenty-Sixth Harvest) included analysis of data submitted from 127 hospitals in North America. That represents nearly all centers performing pediatric and congenital heart operations in the United States and Canada. As an unparalleled platform for assessment of outcomes and for quality improvement activities in the subspecialty of surgery for pediatric and congenital heart disease, the STS CHSD continues to be a primary data source for clinical investigations and for research and innovations related to quality measurement. In 2016, several major original publications reported analyses of data in the CHSD pertaining to various processes of care, including assessment of variation across centers and associations between specific practices, patient characteristics, and outcomes. Additional publications reported the most recent development, evaluation, and application of metrics for quality measurement and reporting of pediatric and congenital heart operation outcomes and center level performance. Use of the STS CHSD for outcomes research and for quality measurement continues to expand as database participation has grown to include nearly all centers in North America, and the available wealth of data in the database continues to grow. This article reviews outcomes research and quality improvement articles published in 2016 that are based on STS CHSD data.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Cardiopatías Congénitas/cirugía , Evaluación de Resultado en la Atención de Salud , Sistema de Registros , Sociedades Médicas , Cirugía Torácica , Bases de Datos Factuales , Humanos , América del Norte
12.
J Am Coll Cardiol ; 70(4): 439-450, 2017 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-28728688

RESUMEN

BACKGROUND: Randomized trials support the use of transcatheter aortic valve replacement (TAVR) for the treatment of aortic stenosis in high- and intermediate-risk patients, but the generalizability of those results in clinical practice has been challenged. OBJECTIVES: The aim of this study was to determine the safety and effectiveness of TAVR versus surgical aortic valve replacement (SAVR), particularly in intermediate- and high-risk patients, in a nationally representative real-world cohort. METHODS: Using data from the Transcatheter Valve Therapy Registry and Society of Thoracic Surgeons National Database linked to Medicare administrative claims for follow-up, 9,464 propensity-matched intermediate- and high-risk (Society of Thoracic Surgeons Predicted Risk of Mortality score ≥3%) U.S. patients who underwent commercial TAVR or SAVR were examined. Death, stroke, and days alive and out of the hospital to 1 year were compared, as well as discharge home, with subgroup analyses by surgical risk, demographics, and comorbidities. RESULTS: In a propensity-matched cohort (median age 82 years, 48% women, median Society of Thoracic Surgeons Predicted Risk of Mortality score 5.6%), TAVR and SAVR patients experienced no difference in 1-year rates of death (17.3% vs. 17.9%; hazard ratio: 0.93; 95% confidence interval [CI]: 0.83 to 1.04) and stroke (4.2% vs. 3.3%; hazard ratio: 1.18; 95% CI: 0.95 to 1.47), and no difference was observed in the proportion of days alive and out of the hospital to 1 year (rate ratio: 1.00; 95% CI: 0.98 to 1.02). However, TAVR patients were more likely to be discharged home after treatment (69.9% vs. 41.2%; odds ratio: 3.19; 95% CI: 2.84 to 3.58). Results were consistent across most subgroups, including among intermediate- and high-risk patients. CONCLUSIONS: Among unselected intermediate- and high-risk patients, TAVR and SAVR resulted in similar rates of death, stroke, and DAOH to 1 year, but TAVR patients were more likely to be discharged home.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Sistema de Registros , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Puntaje de Propensión , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos
13.
Ann Thorac Surg ; 104(1): 22-28, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28577849

RESUMEN

Containing more than 6 million cumulative operative records and accounting for 90% to 95% of adult cardiac surgery performed in the United States, The Society of Thoracic Surgeons Adult Cardiac Surgery Database is an invaluable resource for performance assessment, quality improvement, and clinical research. This article reviews the seven major research efforts published in 2016 that utilized the Adult Cardiac Surgery Database. Two studies evaluated national trends in clinical practice, three assessed the effect of several risk factors on postoperative morbidity and mortality, and two developed new models to evaluate quality of care. The findings of these studies have enhanced clinical practice and delineated areas for future quality improvement research.


Asunto(s)
Investigación Biomédica/tendencias , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Sociedades Médicas , Cirugía Torácica , Adulto , Bases de Datos Factuales , Humanos , Estados Unidos
15.
J Am Coll Cardiol ; 69(10): 1215-1230, 2017 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-27956264

RESUMEN

BACKGROUND: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy (TVT) Registry captures all procedures with Food and Drug Administration-approved transcatheter valve devices performed in the United States, and is mandated as a condition of reimbursement by the Centers for Medicaid & Medicare Services. OBJECTIVES: This annual report focuses on patient characteristics, trends, and outcomes of transcatheter aortic and mitral valve catheter-based valve procedures in the United States. METHODS: We reviewed data for all patients receiving commercially approved devices from 2012 through December 31, 2015, that are entered in the TVT Registry. RESULTS: The 54,782 patients with transcatheter aortic valve replacement demonstrated decreases in expected risk of 30-day operative mortality (STS Predicted Risk of Mortality [PROM]) of 7% to 6% and transcatheter aortic valve replacement PROM (TVT PROM) of 4% to 3% (both p < 0.0001) from 2012 to 2015. Observed in-hospital mortality decreased from 5.7% to 2.9%, and 1-year mortality decreased from 25.8% to 21.6%. However, 30-day post-procedure pacemaker insertion increased from 8.8% in 2013 to 12.0% in 2015. The 2,556 patients who underwent transcatheter mitral leaflet clip in 2015 were similar to patients from 2013 to 2014, with hospital mortality of 2% and with mitral regurgitation reduced to grade ≤2 in 87% of patients (p < 0.0001). The 349 patients who underwent mitral valve-in-valve and mitral valve-in-ring procedures were high risk, with an STS PROM for mitral valve replacement of 11%. The observed hospital mortality was 7.2%, and 30-day post-procedure mortality was 8.5%. CONCLUSIONS: The TVT Registry is an innovative registry that that monitors quality, patient safety and trends for these rapidly evolving new technologies.


Asunto(s)
Cateterismo Cardíaco , Cardiología , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Sistema de Registros , Sociedades Médicas , Cirugía Torácica , Congresos como Asunto , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Estados Unidos
16.
Ann Thorac Surg ; 103(3): 1021-1035, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27955994

RESUMEN

BACKGROUND: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy (TVT) Registry captures all procedures with Food and Drug Administration-approved transcatheter valve devices performed in the United States, and is mandated as a condition of reimbursement by the Centers for Medicaid & Medicare Services. OBJECTIVES: This annual report focuses on patient characteristics, trends, and outcomes of transcatheter aortic and mitral valve catheter-based valve procedures in the United States. METHODS: We reviewed data for all patients receiving commercially approved devices from 2012 through December 31, 2015, that are entered in the TVT Registry. RESULTS: The 54,782 patients with transcatheter aortic valve replacement demonstrated decreases in expected risk of 30-day operative mortality (STS Predicted Risk of Mortality [PROM]) of 7% to 6% and transcatheter aortic valve replacement PROM (TVT PROM) of 4% to 3% (both p < 0.0001) from 2012 to 2015. Observed in-hospital mortality decreased from 5.7% to 2.9%, and 1-year mortality decreased from 25.8% to 21.6%. However, 30-day post-procedure pacemaker insertion increased from 8.8% in 2013 to 12.0% in 2015. The 2,556 patients who underwent transcatheter mitral leaflet clip in 2015 were similar to patients from 2013 to 2014, with hospital mortality of 2% and with mitral regurgitation reduced to grade ≤2 in 87% of patients (p < 0.0001). The 349 patients who underwent mitral valve-in-valve and mitral valve-in-ring procedures were high risk, with an STS PROM for mitral valve replacement of 11%. The observed hospital mortality was 7.2%, and 30-day post-procedure mortality was 8.5%. CONCLUSIONS: The TVT Registry is an innovative registry that that monitors quality, patient safety and trends for these rapidly evolving new technologies.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Mitral/cirugía , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico , Estenosis de la Válvula Mitral/mortalidad , Estudios Retrospectivos , Sociedades Médicas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
18.
Ann Thorac Surg ; 103(1): 18-24, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27884412

RESUMEN

Established in 1989, The Society of Thoracic Surgeons Adult Cardiac Surgery Database is one of the most comprehensive clinical data registries in health care. It is widely regarded as the gold standard for benchmarking risk-adjusted outcomes in cardiac surgery and is the foundation for all quality measurement and improvement activities of The Society of Thoracic Surgeons. This is the second in a series of annual reports that summarizes current aggregate national outcomes in cardiac surgery and reviews database-related activities in the areas of quality measurement and performance improvement during the past year.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/normas , Mejoramiento de la Calidad , Sistema de Registros , Sociedades Médicas , Cirujanos/normas , Cirugía Torácica/normas , Benchmarking , Humanos , Estados Unidos
19.
Ann Thorac Surg ; 102(6): 1790-1797, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27847042

RESUMEN

The art and science of outcomes analysis, quality improvement, and patient safety continue to evolve, and cardiothoracic surgery leads many of these advances. The Society of Thoracic Surgeons (STS) National Database is one of the principal reasons for this leadership role, as it provides a platform for the generation of knowledge in all of these domains. Understanding these topics is a professional responsibility of all cardiothoracic surgeons. Therefore, beginning in January 2016, The Annals of Thoracic Surgery began publishing a monthly series of scholarly articles on outcomes analysis, quality improvement, and patient safety. This article provides a summary of the status of the STS National Database as of October 2016 and summarizes the articles about the STS National Database that appeared in The Annals of Thoracic Surgery 2016 series, "Outcomes Analysis, Quality Improvement, and Patient Safety."


Asunto(s)
Bases de Datos Factuales , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Seguridad del Paciente/estadística & datos numéricos , Mejoramiento de la Calidad/estadística & datos numéricos , Procedimientos Quirúrgicos Torácicos/estadística & datos numéricos , Humanos , Sociedades Médicas , Estados Unidos
20.
Ann Thorac Surg ; 102(5): 1444-1451, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27772572

RESUMEN

The Society of Thoracic Surgeons General Thoracic Surgery Database has grown to more than 500,000 case records. Clinical research supported by the database is increasingly used to advance patient outcomes. This research review from the General Thoracic Surgery Database in 2014 and 2015 discusses 6 recent publications and an ongoing study on longitudinal outcomes in lung cancer surgery from The Society of Thoracic Surgeons Task Force for Linked Registries and Longitudinal Follow-up. A lack of database variables specific for certain uncommon procedures limits the ability to study these operations; inclusion of clinical descriptors for selected infrequent but clinically important thoracic disorders is suggested.


Asunto(s)
Investigación Biomédica/estadística & datos numéricos , Sistema de Registros , Sociedades Médicas , Cirugía Torácica , Procedimientos Quirúrgicos Torácicos/estadística & datos numéricos , Bases de Datos Factuales , Humanos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...