1.
Sci Rep ; 14(1): 10808, 2024 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734763

RESUMEN

Finite element analysis (FEA) is commonly used in orthopaedic research to estimate localised tissue stresses and strains. A variety of boundary conditions have been proposed for isolated femur analysis, but it remains unclear how these assumed constraints influence FEA predictions of bone biomechanics. This study compared the femoral head deflection (FHD), stresses, and strains elicited under four commonly used boundary conditions (fixed knee, mid-shaft constraint, springs, and isostatic methods) and benchmarked these mechanics against the gold standard inertia relief method for normal and pathological femurs (extreme anteversion and retroversion, coxa vara, and coxa valga). Simulations were performed for the stance phase of walking with the applied femoral loading determined from patient-specific neuromusculoskeletal models. Due to unrealistic biomechanics observed for the commonly used boundary conditions, we propose a novel biomechanical constraint method to generate physiological femur biomechanics. The biomechanical method yielded FHD (< 1 mm), strains (approaching 1000 µÎµ), and stresses (< 60 MPa), which were consistent with physiological observations and similar to predictions from the inertia relief method (average coefficient of determination = 0.97, average normalized root mean square error = 0.17). Our results highlight the superior performance of the biomechanical method compared to current methods of constraint for  both healthy and pathological femurs.


Asunto(s)
Fémur , Análisis de Elementos Finitos , Marcha , Estrés Mecánico , Humanos , Fémur/fisiología , Marcha/fisiología , Fenómenos Biomecánicos , Masculino , Adulto , Simulación por Computador , Femenino
2.
J Int Med Res ; 52(3): 3000605241240946, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38534086

RESUMEN

BACKGROUND: To compare the biomechanical stability of a novel, C-shaped nickel-titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). METHODS: In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. RESULTS: The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39-41) and 35 (35-35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44-0.45) and 0.30 (0.30-0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39-41) and 28 (28-31) N/mm; for the C-clip and cerclage wiring, respectively. CONCLUSION: Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results.


Asunto(s)
Fracturas del Fémur , Fracturas Periprotésicas , Humanos , Aleaciones con Memoria de Forma , Fracturas del Fémur/cirugía , Fémur/cirugía , Fracturas Periprotésicas/cirugía , Fijación Interna de Fracturas/métodos , Placas Óseas , Fenómenos Biomecánicos
3.
Materials (Basel) ; 15(9)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35591454

RESUMEN

Orthodontic treatment increasingly involves transparent aligners; however, biomechanical analysis of their treatment effects under clinical conditions is lacking. We compared the biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners and of fixed appliances in simulated clinical orthodontic treatment conditions using orthodontic finite element (FE) models. In the FE analysis, we used Model Activation/De-Activation analysis to validate our method. Fixed appliances and 0.75-mm and 0.5-mm thick transparent aligners were applied to a tooth-alveolar bone FE model with lingually-inclined and axially-rotated central incisors. Compared to the fixed appliance, the 0.75-mm and 0.5-mm transparent aligners induced 5%, 38%, and 28% and 21%, 62%, and 34% less movement of the central incisors and principal stress of the periodontal ligament and of the alveolar bone, respectively, for lingual inclination correction. For axial-rotation correction, these aligners induced 22%, 37%, and 40% and 28%, 67%, and 48% less tooth movement and principal stress of the periodontal ligament and of the alveolar bone, respectively. In conclusion, transparent aligners induced less tooth movement, it is sufficient for orthodontic treatment, but 0.5-mm aligners should be used for only mild corrections. Additionally, the Model Activation/De-Activation analysis method is suitable for FE analysis of orthodontic treatment reflecting clinical treatment conditions.

4.
Materials (Basel) ; 14(17)2021 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-34501017

RESUMEN

Clear aligner technology has become the preferred choice of orthodontic treatment for malocclusions for most adult patients due to their esthetic appeal and comfortability. However, limitations exist for aligner technology, such as corrections involving complex force systems. Composite attachments on the tooth surface are intended to enable active control of tooth movements. However, unintended tooth movements still occur. In this study, we present an effective attachment design of an attachment that can efficiently induce tooth movement by comparing and analyzing the movement and rotation of teeth between a general attachment and an overhanging attachment. The 3D finite element modes were constructed from CBCT data and used to analyze the distal displacement of the central incisor using 0.5- and 0.75-mm-thick aligners without an attachment, and with general and overhanging attachments. The results show that the aligner with the overhanging attachment can effectively reduce crown tipping and prevent axial rotation for an intended distal displacement of the central incisor. In all models, an aligner with or without attachments was not capable of preventing the lingual inclination of the tooth.

5.
Materials (Basel) ; 14(2)2021 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-33435457

RESUMEN

Lately, in orthodontic treatments, the use of transparent aligners for the correction of malocclusions has become prominent owing to their intrinsic advantages such as esthetics, comfort, and minimal maintenance. Attempts at improving upon this technology by varying various parameters to investigate the effects on treatments have been carried out by several researchers. Here, we aimed to investigate the biomechanical and clinical effects of aligner thickness on stress distributions in the periodontal ligament and changes in the tooth's center of rotation. Dental finite element models comprising the cortical and cancellous bones, gingiva, teeth, and nonlinear viscoelastic periodontal ligaments were constructed, validated, and used together with aligner finite element models of different aligner thicknesses to achieve the goal of this study. The finite element analyses were conducted to simulate the actual orthodontic aligner treatment process for the correction of malocclusions by generating pre-stresses in the aligner and allowing the aligner stresses to relax to induce tooth movement. The results of the analyses showed that orthodontic treatment in lingual inclination and axial rotation with a 0.75 mm-thick aligner resulted in 6% and 0.03% higher principal stresses in the periodontal ligament than the same treatment using a 0.05 mm-thick aligner, respectively. Again, for both aligner thicknesses, the tooth's center of rotation moved lingually and towards the root direction in lingual inclination, and diagonally from the long axis of the tooth in axial rotation. Taken together, orthodontic treatment for simple malocclusions using transparent aligners of different thicknesses will produce a similar effect on the principal stresses in the periodontal ligament and similar changes in the tooth's center of rotation, as well as sufficient tooth movement. These findings provide orthodontists and researchers clinical and biomechanical evidence about the effect of transparent aligner thickness selection and its effect on orthodontic treatment.