Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 241
Filtrar
1.
Eur Radiol ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767658

RESUMEN

OBJECTIVES: To investigate associations between tissue diffusion, stiffness, and different tumor microenvironment features in resected hepatocellular carcinoma (HCC). METHODS: Seventy-two patients were prospectively included for preoperative magnetic resonance (MR) diffusion-weighted imaging and MR elastography examination. The mean apparent diffusion coefficient (ADC) and stiffness value were measured on the central three slices of the tumor and peri-tumor area. Cell density, tumor-stroma ratio (TSR), lymphocyte-rich HCC (LR-HCC), and CD8 + T cell infiltration were estimated in resected tumors. The interobserver agreement of MRI measurements and subjective pathological evaluation was assessed. Variables influencing ADC and stiffness were screened with univariate analyses, and then identified with multivariable linear regression. The potential relationship between explored imaging biomarkers and histopathological features was assessed with linear regression after adjustment for other influencing factors. RESULTS: Seventy-two patients (male/female: 59/13, mean age: 56 ± 10.2 years) were included for analysis. Inter-reader agreement was good or excellent regarding MRI measurements and histopathological evaluation. No correlation between tumor ADC and tumor stiffness was found. Multivariable linear regression confirmed that cell density was the only factor associated with tumor ADC (Estimate = -0.03, p = 0.006), and tumor-stroma ratio was the only factor associated with tumor stiffness (Estimate = -0.18, p = 0.03). After adjustment for fibrosis stage (Estimate = 0.43, p < 0.001) and age (Estimate = 0.04, p < 0.001) in the multivariate linear regression, intra-tumoral CD8 + T cell infiltration remained a significant factor associated with peri-tumor stiffness (Estimate = 0.63, p = 0.02). CONCLUSIONS: Tumor ADC surpasses tumor stiffness as a biomarker of cellularity. Tumor stiffness is associated with tumor-stroma ratio and peri-tumor stiffness might be an imaging biomarker of intra-tumoral immune microenvironment. CLINICAL RELEVANCE STATEMENT: Tissue stiffness could potentially serve as an imaging biomarker of the intra-tumoral immune microenvironment of hepatocellular carcinoma and aid in patient selection for immunotherapy. KEY POINTS: Apparent diffusion coefficient reflects cellularity of hepatocellular carcinoma. Tumor stiffness reflects tumor-stroma ratio of hepatocellular carcinoma and is associated with tumor-infiltrating lymphocytes. Tumor and peri-tumor stiffness might serve as imaging biomarkers of intra-tumoral immune microenvironment.

2.
Radiology ; 311(2): e233136, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742971

RESUMEN

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Diagnóstico por Imagen de Elasticidad/métodos , Diagnóstico por Imagen de Elasticidad/instrumentación , Reproducibilidad de los Resultados , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/diagnóstico por imagen
3.
AJNR Am J Neuroradiol ; 45(5): 662-667, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38485194

RESUMEN

BACKGROUND AND PURPOSE: Spontaneous intracranial hypotension is a condition resulting from a leak of CSF from the spinal canal arising independent of a medical procedure. Spontaneous intracranial hypotension can present with normal brain MR imaging findings and nonspecific symptoms, leading to the underdiagnosis in some patients and unnecessary invasive myelography in others who are found not to have the condition. Given the likelihood that spontaneous intracranial hypotension alters intracranial biomechanics, the goal of this study was to evaluate MR elastography as a potential noninvasive test to diagnose the condition. MATERIALS AND METHODS: We performed MR elastography in 15 patients with confirmed spontaneous intracranial hypotension from September 2022 to April 2023. Age, sex, symptom duration, and brain MR imaging Bern score were collected. MR elastography data were used to compute stiffness and damping ratio maps, and voxelwise modeling was performed to detect clusters of significant differences in mechanical properties between patients with spontaneous intracranial hypotension and healthy control participants. To evaluate diagnostic accuracy, we summarized each examination by 2 spatial pattern scores (one each for stiffness and damping ratio) and evaluated group-wise discrimination by receiver operating characteristic curve analysis. RESULTS: Patients with spontaneous intracranial hypotension exhibited significant differences in both stiffness and damping ratio (false discovery rate-corrected, Q < 0.05). Pattern analysis discriminated patients with spontaneous intracranial hypotension from healthy controls with an area under the curve of 0.97 overall, and the area under the curve was 0.97 in those without MR imaging findings of spontaneous intracranial hypotension. CONCLUSIONS: Results from this pilot study demonstrate MR elastography as a potential imaging biomarker and a noninvasive method for diagnosing spontaneous intracranial hypotension, including patients with normal brain MR imaging findings.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipotensión Intracraneal , Imagen por Resonancia Magnética , Humanos , Hipotensión Intracraneal/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Anciano , Adulto Joven
4.
Radiology ; 310(3): e231220, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38470236

RESUMEN

Chronic liver disease is highly prevalent and often leads to fibrosis or cirrhosis and complications such as liver failure and hepatocellular carcinoma. The diagnosis and staging of liver fibrosis is crucial to determine management and mitigate complications. Liver biopsy for histologic assessment has limitations such as sampling bias and high interreader variability that reduce precision, which is particularly challenging in longitudinal monitoring. MR elastography (MRE) is considered the most accurate noninvasive technique for diagnosing and staging liver fibrosis. In MRE, low-frequency vibrations are applied to the abdomen, and the propagation of shear waves through the liver is analyzed to measure liver stiffness, a biomarker for the detection and staging of liver fibrosis. As MRE has become more widely used in clinical care and research, different contexts of use have emerged. This review focuses on the latest developments in the use of MRE for the assessment of liver fibrosis; provides guidance for image acquisition and interpretation; summarizes diagnostic performance, along with thresholds for diagnosis and staging of liver fibrosis; discusses current and emerging clinical applications; and describes the latest technical developments.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Neoplasias Hepáticas , Humanos , Abdomen , Cirrosis Hepática/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen
5.
Brain Commun ; 6(2): fcae073, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38505229

RESUMEN

Vascular brain injury results in loss of structural and functional connectivity and leads to cognitive impairment. Its various manifestations, including microinfarcts, microhaemorrhages and white matter hyperintensities, result in microstructural tissue integrity loss and secondary neurodegeneration. Among these, tissue microstructural alteration is a relatively early event compared with atrophy along the aging and neurodegeneration continuum. Understanding its association with cognition may provide the opportunity to further elucidate the relationship between vascular health and clinical outcomes. Magnetic resonance elastography offers a non-invasive approach to evaluate tissue mechanical properties, providing a window into the microstructural integrity of the brain. This retrospective study evaluated brain stiffness as a potential biomarker for vascular brain injury and its role in mediating the impact of vascular dysfunction on cognitive impairment. Seventy-five participants from the Mayo Clinic Study of Aging underwent brain imaging using a 3T MR imager with a spin-echo echo-planar imaging sequence for magnetic resonance elastography and T1- and T2-weighted pulse sequences. This study evaluated the effects of vascular biomarkers (white matter hyperintensities and cardiometabolic condition score) on brain stiffness using voxelwise analysis. Partial correlation analysis explored associations between brain stiffness, white matter hyperintensities, cardiometabolic condition and global cognition. Mediation analysis determined the role of stiffness in mediating the relationship between vascular biomarkers and cognitive performance. Statistical significance was set at P-values < 0.05. Diagnostic accuracy of magnetic resonance elastography stiffness for white matter hyperintensities and cardiometabolic condition was evaluated using receiver operator characteristic curves. Voxelwise linear regression analysis indicated white matter hyperintensities negatively correlate with brain stiffness, specifically in periventricular regions with high white matter hyperintensity levels. A negative association between cardiovascular risk factors and stiffness was also observed across the brain. No significant patterns of stiffness changes were associated with amyloid load. Global stiffness (µ) negatively correlated with both white matter hyperintensities and cardiometabolic condition when all other covariables including amyloid load were controlled. The positive correlation between white matter hyperintensities and cardiometabolic condition weakened and became statistically insignificant when controlling for other covariables. Brain stiffness and global cognition were positively correlated, maintaining statistical significance after adjusting for all covariables. These findings suggest mechanical alterations are associated with cognitive dysfunction and vascular brain injury. Brain stiffness significantly mediated the indirect effects of white matter hyperintensities and cardiometabolic condition on global cognition. Local cerebrovascular diseases (assessed by white matter hyperintensities) and systemic vascular risk factors (assessed by cardiometabolic condition) impact brain stiffness with spatially and statistically distinct effects. Global brain stiffness is a significant mediator between vascular disease measures and cognitive function, highlighting the value of magnetic resonance elastography-based mechanical assessments in understanding this relationship.

6.
Neurotrauma Rep ; 5(1): 232-242, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38524727

RESUMEN

This study sought to identify whether an anatomical indicator of injury severity as measured by multiparametric magnetic resonance imaging (MRI) including magnetic resonance elastography (MRE), is predictive of a clinical measure of injury severity after moderate-severe traumatic brain injury (TBI). Nine individuals who were admitted to acute inpatient rehabilitation after moderate-to-severe TBI completed a comprehensive MRI protocol prior to discharge from rehabilitation, which included conventional MRI with diffusion tensor imaging (DTI). Of those, five of nine also underwent brain MRE to measure the brain parenchyma stiffness. Clinical severity of injury was measured by the length of post-traumatic amnesia (PTA). MRI-assessed non-hemorrhage contusion score and hemorrhage score, DTI-measured white matter fractional anisotropy, and MRE-measured lesion stiffness were all assessed. A higher hemorrhagic score was significantly associated with a longer length of PTA (p = 0.026). Participants with a longer PTA tended to have a higher non-hemorrhage contusion score and softer contusion lesions than the contralateral control side, although the small sample size did not allow for assessment of a significant association. To our knowledge, this is the first report applying MRI/MRE imaging protocol to quantitate altered brain anatomy after moderate-severe TBI and its association with PTA, a known clinical predictor of post-acute outcome. Future larger studies could lead to the development of prediction models that integrate clinical data with anatomical (MRI), structural (DTI), and mechanical (MRE) changes caused by TBI, to inform prognosis and care planning.

7.
Magn Reson Med ; 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38523575

RESUMEN

PURPOSE: Abnormal adherence at functional myofascial interfaces is hypothesized as an important phenomenon in myofascial pain syndrome. This study aimed to investigate the feasibility of MR elastography (MRE)-based slip interface imaging (SII) to visualize and assess myofascial mobility in healthy volunteers. METHODS: SII was used to assess local shear strain at functional myofascial interfaces in the flexor digitorum profundus (FDP) and thighs. In the FDP, MRE was performed at 90 Hz vibration to each index, middle, ring, and little finger. Two thigh MRE scans were performed at 40 Hz with knees flexed and extended. The normalized octahedral shear strain (NOSS) maps were calculated to visualize myofascial slip interfaces. The entropy of the probability distribution of the gradient NOSS was computed for the two knee positions at the intermuscular interface between vastus lateralis and vastus intermedius, around rectus femoris, and between vastus intermedius and vastus medialis. RESULTS: NOSS map depicted distinct functional slip interfaces in the FDP for each finger. Compared to knee flexion, clearer slip interfaces and larger gradient NOSS entropy at the vastus lateralis-vastus intermedius interface were observed during knee extension, where the quadriceps are not passively stretched. This suggests the optimal position for using SII to visualize myofascial slip interface in skeletal muscles is when muscles are not subjected to any additional force. CONCLUSION: The study demonstrated that MRE-based SII can visualize and assess myofascial interface mobility in extremities. The results provide a foundation for investigating the hypothesis that myofascial pain syndrome is characterized by changes in the mobility of myofascial interfaces.

8.
AJNR Am J Neuroradiol ; 45(3): 328-334, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38272572

RESUMEN

BACKGROUND AND PURPOSE: Normal pressure hydrocephalus is a treatable cause of dementia associated with distinct mechanical property signatures in the brain as measured by MR elastography. In this study, we tested the hypothesis that specific anatomic features of normal pressure hydrocephalus are associated with unique mechanical property alterations. Then, we tested the hypothesis that summary measures of these mechanical signatures can be used to predict clinical outcomes. MATERIALS AND METHODS: MR elastography and structural imaging were performed in 128 patients with suspected normal pressure hydrocephalus and 44 control participants. Patients were categorized into 4 subgroups based on their anatomic features. Surgery outcome was acquired for 68 patients. Voxelwise modeling was performed to detect regions with significantly different mechanical properties between each group. Mechanical signatures were summarized using pattern analysis and were used as features to train classification models and predict shunt outcomes for 2 sets of feature spaces: a limited 2D feature space that included the most common features found in normal pressure hydrocephalus and an expanded 20-dimensional (20D) feature space that included features from all 4 morphologic subgroups. RESULTS: Both the 2D and 20D classifiers performed significantly better than chance for predicting clinical outcomes with estimated areas under the receiver operating characteristic curve of 0.66 and 0.77, respectively (P < .05, permutation test). The 20D classifier significantly improved the diagnostic OR and positive predictive value compared with the 2D classifier (P < .05, permutation test). CONCLUSIONS: MR elastography provides further insight into mechanical alterations in the normal pressure hydrocephalus brain and is a promising, noninvasive method for predicting surgical outcomes in patients with normal pressure hydrocephalus.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hidrocéfalo Normotenso , Hidrocefalia , Humanos , Hidrocéfalo Normotenso/diagnóstico por imagen , Hidrocéfalo Normotenso/cirugía , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Resultado del Tratamiento
9.
AJR Am J Roentgenol ; 222(1): e2329437, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37162036

RESUMEN

MR elastography (MRE), first described in 1995 and FDA-cleared in 2009, has emerged as an important tool for noninvasively detecting and staging liver fibrosis in patients with known or suspected chronic liver disease. This review focuses on a series of practical questions about the clinical use of MRE. Most head-to-head comparison studies with other laboratory and imaging-based tests have concluded that MRE has the highest diagnostic performance among tests for staging liver fibrosis. Limitations in the accuracy of biopsy as a standard of truth in staging liver fibrosis are increasingly being recognized. MRE-based measurements show promise as quantitative surrogates of disease severity and predictors of important clinical outcomes. The appropriate role of MRE in the management of patients with chronic liver disease is being actively incorporated into recognized clinical guidelines. Growing evidence shows that MRI measurement of elevated liver fat is the most important single biomarker for detecting nonalcoholic steatohepatitis (NASH) and that MRE-based liver stiffness is the most important single biomarker for detecting at-risk NASH (i.e., NASH with stage ≥ F2 fibrosis). Advances in MRE technology are offering higher precision and new biomarkers, which have potential to allow independent assessment of inflammation and other histologic processes in addition to fibrosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/patología , Diagnóstico por Imagen de Elasticidad/métodos , Reproducibilidad de los Resultados , Hígado/diagnóstico por imagen , Cirrosis Hepática/patología , Imagen por Resonancia Magnética/métodos , Biomarcadores
10.
NMR Biomed ; 37(2): e5047, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37813110

RESUMEN

Magnetic resonance elastography (MRE) is an accurate noninvasive diagnostic tool for assessing the stiffness of parenchymal organs, including the spleen. However, this measurement may be biased due to postprandial changes in splenic stiffness. The aim of the current study was to evaluate postprandial changes in spleen stiffness assessed by MRE in a large sample of healthy volunteers. This was a prospective institutional research ethics board-approved study. Healthy volunteers with no history of liver disease were recruited for an MRE test and blood draw from December 2018 to July 2019. Each participant underwent spleen MRE after at least 4 h of fasting and again 30 min after a 1000 kcal meal. Also, 14 randomly selected volunteers underwent additional MRE examinations at 1.5 and 2.5 h after food intake. The MRE data were acquired at 60 Hz using a 1.5-T MRI scanner. The spleen stiffness was assessed using a weighted mean of stiffness values from regions of interest manually drawn on three to five spleen slices. Spearman's rank correlation, Wilcoxon signed-rank, Friedman, and Mann-Whitney tests were used for statistical analysis. A total of 100 volunteers met the inclusion criteria and were eventually enrolled in this study (age 23 ± 2 years; 65 women). The mean spleen stiffness for the whole group increased by 7.9% (p < 0.001) from the mean ± SD value of 5.09 ± 0.63 (95% CI: 4.96-5.21) kPa in the fasting state to 5.47 ± 0.66 (95% CI 5.34-5.60) kPa 30 min after the meal and then gradually decreased. However, even 2 h 30 min after the meal, the spleen stiffness was higher than in the fasting state. This difference was statistically significant at p less than 0.001. It was concluded that meal intake results in a statistically significant elevation of spleen stiffness that persists for 2.5 h. This finding supports the recommendation for routine fasting for more than 2.5 h prior to assessing MRE-based spleen stiffness.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Bazo , Humanos , Femenino , Adulto Joven , Adulto , Bazo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos
11.
Magn Reson Med ; 91(5): 1923-1935, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38098427

RESUMEN

PURPOSE: To demonstrate a novel MR elastography (MRE) technique, termed here wavelet MRE. With this technique, broadband motion sensitivity is achievable. Moreover, the true tissue displacement can be reconstructed with a simple inverse transform. METHODS: A wavelet MRE sequence was developed with motion-encoding gradients based on Haar wavelets. From the phase images' displacement was estimated using an inverse transform. Simulations were performed using a frequency sweep and a transient as ground-truth motions. A PVC phantom was scanned using wavelet MRE and standard MRE with both transient (one and 10 cycles of 90-Hz motion) and steady-state dual-frequency motion (30 and 60 Hz) for comparison. The technique was tested in a human brain, and motion trajectories were estimated for each voxel. RESULTS: In simulation, the displacement information estimated from wavelet MRE closely matched the true motion. In the phantom test, the MRE phase data generated from the displacement information derived from wavelet MRE agreed well with standard MRE data. Testing of wavelet MRE to assess transient motion waveforms in the brain was successful, and the tissue motion observed was consistent with a previous study. CONCLUSION: The uniform and broadband frequency response of wavelet MRE makes it a promising method for imaging transient, multifrequency motion, or motion with unknown frequency content. One potential application is measuring the response of brain tissue undergoing low-amplitude, transient vibrations as a model for the study of traumatic brain injury.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Fantasmas de Imagen , Sonido
12.
Contemp Clin Trials ; 134: 107352, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37802221

RESUMEN

Non-alcoholic fatty liver disease (NAFLD) is the liver manifestation of the metabolic syndrome with global prevalence reaching epidemic levels. Despite the high disease burden in the population only a small proportion of those with NAFLD will develop progressive liver disease, for which there is currently no approved pharmacotherapy. Identifying those who are at risk of progressive NAFLD currently requires a liver biopsy which is problematic. Firstly, liver biopsy is invasive and therefore not appropriate for use in a condition like NAFLD that affects a large proportion of the population. Secondly, biopsy is limited by sampling and observer dependent variability which can lead to misclassification of disease severity. Non-invasive biomarkers are therefore needed to replace liver biopsy in the assessment of NAFLD. Our study addresses this unmet need. The LITMUS Imaging Study is a prospectively recruited multi-centre cohort study evaluating magnetic resonance imaging and elastography, and ultrasound elastography against liver histology as the reference standard. Imaging biomarkers and biopsy are acquired within a 100-day window. The study employs standardised processes for imaging data collection and analysis as well as a real time central monitoring and quality control process for all the data submitted for analysis. It is anticipated that the high-quality data generated from this study will underpin changes in clinical practice for the benefit of people with NAFLD. Study Registration: clinicaltrials.gov: NCT05479721.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios de Cohortes , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Imagen por Resonancia Magnética/métodos , Biomarcadores
13.
Diagnostics (Basel) ; 13(17)2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37685274

RESUMEN

PURPOSE: Magnetic resonance elastography (MRE) has been established as the most accurate noninvasive technique for diagnosing liver fibrosis. Recent publications have suggested that the measurement of splenic stiffness is useful in setting where portal hypertension may be present. The goal of the current study was to compile normative data for MRE-assessed stiffness measurements of the spleen in young adults. MATERIALS AND METHODS: A total of 100 healthy young Caucasian volunteers (65 females and 35 males) in the age range of 20 to 32 years were enrolled in this study. The participants reported no history of chronic spleen and liver disease, normal alcohol consumption, and a normal diet. The MRE data were acquired by using a 1.5 T whole-body scanner and a 2D GRE pulse sequence with 60 Hz excitation. Spleen stiffness was calculated as a weighted mean of stiffness values in the regions of interest manually drawn by the radiologist on three to five spleen slices. RESULTS: Mean spleen stiffness was 5.09 ± 0.65 kPa for the whole group. Male volunteers had slightly higher splenic stiffness compared to females: 5.28 ± 0.78 vs. 4.98 ± 0.51 kPa, however, this difference was not statistically significant (p = 0.12). Spleen stiffness did not correlate with spleen fat content and liver stiffness but a statistically significant correlation with spleen volume was found. CONCLUSIONS: The findings of this study provide normative values for 2D MRE-based measurement of spleen stiffness in young adults, a basis for assessing the value of this biomarker in young patients with portal system pathologies.

14.
J Neurotrauma ; 40(19-20): 2193-2204, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37233723

RESUMEN

Increasing concerns have been raised about the long-term negative effects of subconcussive repeated head impact (RHI). To elucidate RHI injury mechanisms, many efforts have studied how head impacts affect the skull-brain biomechanics and have found that mechanical interactions at the skull-brain interface dampen and isolate brain motions by decoupling the brain from the skull. Despite intense interest, in vivo quantification of the functional state of the skull-brain interface remains difficult. This study developed a magnetic resonance elastography (MRE) based technique to non-invasively assess skull-brain mechanical interactions (i.e., motion transmission and isolation function) under dynamic loading. The full MRE displacement data were separated into rigid body motion and wave motion. The rigid body motion was used to calculate the brain-to-skull rotational motion transmission ratio (Rtr) to quantify skull-brain motion transmissibility, and the wave motion was used to calculate the cortical normalized octahedral shear strain (NOSS) (calculated based on a partial derivative computing neural network) to evaluate the isolation capability of the skull-brain interface. Forty-seven healthy volunteers were recruited to investigate the effects of age/sex on Rtr and cortical NOSS, and 17 of 47 volunteers received multiple scans to test the repeatability of the proposed techniques under different strain conditions. The results showed that both Rtr and NOSS were robust to MRE driver variations and had good repeatability, with intraclass correlation coefficient (ICC) values between 0.68 and 0.97 (fair to excellent). No age or sex dependence were observed with Rtr, whereas a significant positive correlation between age and NOSS was found in the cerebrum, frontal, temporal, and parietal lobes (all p < 0.05), but not in the occipital lobe (p = 0.99). The greatest change in NOSS with age was found in the frontal lobe, one of the most frequent locations of traumatic brain injury (TBI). Except for the temporal lobe (p = 0.0087), there was no significant difference in NOSS between men and women. This work provides motivation for utilizing MRE as a non-invasive tool for quantifying the biomechanics of the skull-brain interface. It evaluated the age and sex dependence and may lead to a better understanding of the protective role and mechanisms of the skull-brain interface in RHI and TBI, as well as improve the accuracy of computational models in simulating the skull-brain interface.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Diagnóstico por Imagen de Elasticidad , Masculino , Humanos , Femenino , Diagnóstico por Imagen de Elasticidad/métodos , Fenómenos Biomecánicos , Caracteres Sexuales , Encéfalo/diagnóstico por imagen , Cráneo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen
15.
Hepatology ; 78(4): 1200-1208, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37080558

RESUMEN

BACKGROUND AND AIMS: The presence of at-risk NASH is associated with an increased risk of cirrhosis and complications. Therefore, noninvasive identification of at-risk NASH with an accurate biomarker is a critical need for pharmacologic therapy. We aim to explore the performance of several magnetic resonance (MR)-based imaging parameters in diagnosing at-risk NASH. APPROACH AND RESULTS: This prospective clinical trial (NCT02565446) includes 104 paired MR examinations and liver biopsies performed in patients with suspected or diagnosed NAFLD. Magnetic resonance elastography-assessed liver stiffness (LS), 6-point Dixon-derived proton density fat fraction (PDFF), and single-point saturation-recovery acquisition-calculated T1 relaxation time were explored. Among all predictors, LS showed the significantly highest accuracy in diagnosing at-risk NASH [AUC LS : 0.89 (0.82, 0.95), AUC PDFF : 0.70 (0.58, 0.81), AUC T1 : 0.72 (0.61, 0.82), z -score test z >1.96 for LS vs any of others]. The optimal cutoff value of LS to identify at-risk NASH patients was 3.3 kPa (sensitivity: 79%, specificity: 82%, negative predictive value: 91%), whereas the optimal cutoff value of T1 was 850 ms (sensitivity: 75%, specificity: 63%, and negative predictive value: 87%). PDFF had the highest performance in diagnosing NASH with any fibrosis stage [AUC PDFF : 0.82 (0.72, 0.91), AUC LS : 0.73 (0.63, 0.84), AUC T1 : 0.72 (0.61, 0.83), |z| <1.96 for all]. CONCLUSION: Magnetic resonance elastography-assessed LS alone outperformed PDFF, and T1 in identifying patients with at-risk NASH for therapeutic trials.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Imagen por Resonancia Magnética/métodos , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Protones , Estudios Prospectivos
16.
J Hepatol ; 79(3): 592-604, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37121437

RESUMEN

BACKGROUND & AIMS: We conducted an individual patient data meta-analysis to establish stiffness cut-off values for magnetic resonance elastography (MRE) in staging liver fibrosis and to assess potential confounding factors. METHODS: A systematic review of the literature identified studies reporting MRE data in patients with NAFLD. Data were obtained from the corresponding authors. The pooled diagnostic cut-off value for the various fibrosis stages was determined in a two-stage meta-analysis. Multilevel modelling methods were used to analyse potential confounding factors influencing the diagnostic accuracy of MRE in staging liver fibrosis. RESULTS: Eight independent cohorts comprising 798 patients were included in the meta-analysis. The area under the receiver operating characteristic curve (AUROC) for MRE in detecting significant fibrosis was 0.92 (sensitivity, 79%; specificity, 89%). For advanced fibrosis, the AUROC was 0.92 (sensitivity, 87%; specificity, 88%). For cirrhosis, the AUROC was 0.94 (sensitivity, 88%, specificity, 89%). Cut-offs were defined to explore concordance between MRE and histopathology: ≥F2, 3.14 kPa (pretest probability, 39.4%); ≥F3, 3.53 kPa (pretest probability, 24.1%); and F4, 4.45 kPa (pretest probability, 8.7%). In generalized linear mixed model analysis, histological steatohepatitis with higher inflammatory activity (odds ratio 2.448, 95% CI 1.180-5.079, p <0.05) and high gamma-glutamyl transferase (GGT) concentration (>120U/L) (odds ratio 3.388, 95% CI 1.577-7.278, p <0.01] were significantly associated with elevated liver stiffness, and thus affecting accuracy in staging early fibrosis (F0-F1). Steatosis, as measured by magnetic resonance imaging proton density fat fraction, and body mass index(BMI) were not confounders. CONCLUSIONS: MRE has excellent diagnostic performance for significant, advanced fibrosis and cirrhosis in patients with NAFLD. Elevated inflammatory activity and GGT level may lead to overestimation of early liver fibrosis, but anthropometric measures such as BMI or the degree of steatosis do not. IMPACT AND IMPLICATIONS: This individual patient data meta-analysis of eight international cohorts, including 798 patients, demonstrated that MRE achieves excellent diagnostic accuracy for significant, advanced fibrosis and cirrhosis in patients with NAFLD. Cut-off values (significant fibrosis, 3.14 kPa; advanced fibrosis, 3.53 kPa; and cirrhosis, 4.45 kPa) were established. Elevated inflammatory activity and gamma-glutamyltransferase level may affect the diagnostic accuracy of MRE, leading to overestimation of liver fibrosis in early stages. We observed no impact of diabetes, obesity, or any other metabolic disorder on the diagnostic accuracy of MRE.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/etiología , Fibrosis , Curva ROC , Imagen por Resonancia Magnética/métodos , Hígado/diagnóstico por imagen , Hígado/patología
17.
JHEP Rep ; 5(4): 100661, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36866389

RESUMEN

Background & Aims: FALCON 1 was a phase IIb study of pegbelfermin in patients with non-alcoholic steatohepatitis (NASH) and stage 3 fibrosis. This FALCON 1 post hoc analysis aimed to further assess the effect of pegbelfermin on NASH-related biomarkers, correlations between histological assessments and non-invasive biomarkers, and concordance between the week 24 histologically assessed primary endpoint response and biomarkers. Methods: Blood-based composite fibrosis scores, blood-based biomarkers, and imaging biomarkers were evaluated for patients with available data from FALCON 1 at baseline through week 24. SomaSignal tests assessed protein signatures of NASH steatosis, inflammation, ballooning, and fibrosis in blood. Linear mixed-effect models were fit for each biomarker. Correlations and concordance were assessed between blood-based biomarkers, imaging, and histological metrics. Results: At week 24, pegbelfermin significantly improved blood-based composite fibrosis scores (ELF, FIB-4, APRI), fibrogenesis biomarkers (PRO-C3 and PC3X), adiponectin, CK-18, hepatic fat fraction measured by MRI-proton density fat fraction, and all four SomaSignal NASH component tests. Correlation analyses between histological and non-invasive measures identified four main categories: steatosis/metabolism, tissue injury, fibrosis, and biopsy-based metrics. Concordant and discordant effects of pegbelfermin on the primary endpoint vs. biomarker responses were observed; the most clear and concordant effects were on measures of liver steatosis and metabolism. A significant association between hepatic fat measured histologically and by imaging was observed in pegbelfermin arms. Conclusions: Pegbelfermin improved NASH-related biomarkers most consistently through improvement of liver steatosis, though biomarkers of tissue injury/inflammation and fibrosis were also improved. Concordance analysis shows that non-invasive assessments of NASH support and exceed the improvements detected by liver biopsy, suggesting that greater consideration should be given to the totality of available data when evaluating the efficacy of NASH therapeutics. Clinical trial number: Post hoc analysis of NCT03486899. Impact and implications: FALCON 1 was a study of pegbelfermin vs. placebo in patients with non-alcoholic steatohepatitis (NASH) without cirrhosis; in this study, patients who responded to pegbelfermin treatment were identified through examination of liver fibrosis in tissue samples collected through biopsy. In the current analysis, non-invasive blood- and imaging-based measures of fibrosis, liver fat, and liver injury were used to determine pegbelfermin treatment response to see how they compared with the biopsy-based results. We found that many of the non-invasive tests, particularly those that measured liver fat, identified patients who responded to pegbelfermin treatment, consistent with the liver biopsy findings. These results suggest that there may be additional value in using data from non-invasive tests, along with liver biopsy, to evaluate how well patients with NASH respond to treatment.

18.
Abdom Radiol (NY) ; 48(6): 1945-1954, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36928333

RESUMEN

PURPOSE: To evaluate the performance and repeatability assessing liver, spleen, and kidney stiffness with magnetic resonance elastography (MRE), using arrays of pneumatic passive drivers. METHODS: An array of four flexible, pneumatically activated passive drivers for abdominal MRE were developed and tested in this study. Multiple MRE acquisitions were performed prospectively in a series of eleven volunteers, with activation of all combinations of the four drivers, individually and simultaneously. MRE exams were repeated three times to study within-day and between-day test-retest repeatability. Semi-quantitative evaluation of wave propagation and penetration, and quantitative assessment of tissue stiffness was conducted for liver, spleen, and kidneys. RESULTS: When driver location and amplitude were sufficient to achieve necessary shear wave illumination in any given region of interest, the results showed excellent test-retest repeatability in abdominal organ stiffness with both single and multiple driver configurations. The results confirmed that multiple driver arrays provided suitable shear wave illumination over a larger region of the abdomen, allowing more reliable stiffness measurements in multiple organs. MRE assessment of the spleen was found to be prone to effects of excessive shear wave amplitude, however. CONCLUSION: A multiple driver array provides shear wave illumination over a larger region of the abdomen than obtained with a single driver, for MRE assessment of multiple abdominal organs, providing excellent test-retest repeatability in stiffness measurements. However, careful tuning of the location and amplitude of each driver is essential to achieve consistent results.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Abdomen/diagnóstico por imagen , Bazo/diagnóstico por imagen , Riñón , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos
19.
Neuroimage Clin ; 37: 103328, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36696808

RESUMEN

BACKGROUND: Aging and dementia involve the disruption of brain molecular pathways leading to the alterations in tissue composition and gross morphology of the brain. Phenotypic and biomarker overlap between various etiologies of dementia supports a need for new modes of information to more accurately distinguish these disorders. Brain mechanical properties, which can be measured noninvasively by MR elastography, represent one understudied feature that are sensitive to neurodegenerative processes. In this study, we used two stiffness estimation schemes to test the hypothesis that different etiologies of dementia are associated with unique patterns of mechanical alterations across the cerebral cortex. METHODS: MR elastography data were acquired for six clinical groups including amyloid-negative cognitively unimpaired (CU), amyloid-positive cognitively unimpaired (A + CU), amyloid-positive participants with mild cognitive impairment (A + MCI), amyloid-positive participants with Alzheimer's clinical syndrome (A + ACS), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD). Stiffness maps were computed using two neural network inversions with the objective to at least partially separate the parenchyma-specific and morphological effects of neurodegeneration on mechanical property estimates. A tissue-confined inversion algorithm was designed to obtain the best estimate of stiffness in the brain parenchyma itself, while a regionally-aware inversion algorithm was used to measure the tissue stiffness along with the surroundings. Mean stiffness of 15 bilateral gray matter cortical regions were considered for statistical analysis. First, we tested the hypothesis that cortical stiffness changes in the aging brain. Next, we tested the overall study hypothesis by first comparing stiffness in each clinical group to the CU group, and then comparing the clinical groups against one another. Finally, we assessed the spatial and statistical overlap between atrophy and stiffness changes for both inversions. RESULTS: Cortical brain regions become softer with age for both inversions with larger effects observed using regionally-aware stiffness. Stiffness decreases in the range 0.010-0.027 kPa per year were observed. Pairwise comparisons of each clinical group with cognitively unimpaired participants demonstrated 5 statistically significant differences in stiffness for tissue-confined measurements and 19 statistically different stiffness changes for the regionally-aware stiffness measurements. Pairwise comparisons between clinical groups further demonstrated unique patterns of stiffness differences. Analysis of the atrophy-versus-stiffness relationship showed that regionally-aware stiffness measurements exhibit higher sensitivity to neurodegeneration with findings that are not fully explained by partial volume effects or atrophy. CONCLUSIONS: Both tissue-confined and regionally-aware stiffness estimates exhibited unique and complementary stiffness differences in various etiologies of dementia. Our results suggest that mechanical alterations measured by MRE reflect both tissue-specific differences as well as environmental effects. Multi-inversion schemes in MRE may provide new insights into the relationships between neuropathology and brain biomechanics.


Asunto(s)
Enfermedad de Alzheimer , Diagnóstico por Imagen de Elasticidad , Demencia Frontotemporal , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Demencia Frontotemporal/patología , Corteza Cerebral/patología , Atrofia/patología , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Imagen por Resonancia Magnética/métodos
20.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...