1.
Magn Reson Med ; 47(5): 940-7, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-11979573

RESUMEN

MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal flip angle for the TrueFISP sequence was calculated for the best temperature sensitivity in the image signal from liver tissue, and verified from the images acquired during the thermocoagulation of excised pig liver. Factors influencing the accuracy of the measured temperatures are discussed. The TrueFISP results are compared to the calculated values of optimized SE and 3D GRE sequences. The accuracy of TrueFISP in the liver at 0.23 T, in imaging conditions used during thermocoagulation procedures, is estimated to be +/-3.3 degrees C for a voxel of 2.5 x 2.5 x 6 mm(3) and acquisition time of 18 s. For the SE and GRE sequences, with similar resolution and somewhat longer imaging time, the uncertainty in the temperature is estimated to be larger by a factor of 2 and 1.2, respectively.


Asunto(s)
Temperatura Corporal/fisiología , Hígado/fisiología , Imagen por Resonancia Magnética/métodos , Animales , Electrocoagulación , Sensibilidad y Especificidad , Porcinos
2.
J Magn Reson Imaging ; 10(2): 216-9, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10441028

RESUMEN

This article presents a miniaturized electron spin resonance (ESR) probe for deducing the position of a surgical instrument on an MR image. The ESR probe constructed was small enough to fit inside a 14-G biopsy needle sheath, and position information of the sheath could be acquired using a simple gradient sequence. The position accuracy was estimated from needle trajectories as inferred from the needle artifact, the actual physical trajectory, and measured coordinates. The probe was able to track the tip of a biopsy needle quickly (10 samples/sec) and precisely with accuracy better than +/-2 mm. J. Magn. Reson. Imaging 1999;10:216-219.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/instrumentación , Imagen por Resonancia Magnética/instrumentación , Artefactos , Biopsia con Aguja/instrumentación , Biopsia con Aguja/métodos , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
3.
Acta Radiol ; 39(1): 10-7, 1998 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9498861

RESUMEN

PURPOSE: To evaluate a new single-electron contrast agent for Overhauser-enhanced MR imaging. The contrast agents that are currently available give enhancement factors that are too low to make the technique a valid option for routine clinical use. MATERIAL AND METHODS: MR images were generated directly following the injection of the substance into rats. The MR scanner was operated at a main magnetic field of 0.01 T and equipped with a separate rf-transmitter tuned to the electron paramagnetic resonance frequency of the contrast agent. RESULTS: As expected, the images generated show a high level of enhancement in areas where the contrast agent was present, and a maximum enhancement of 60 times the normal proton signal was obtained in the vascular area. The signal-to-noise ratios in the images were superior to those previously attained. CONCLUSION: The new contrast agent makes it possible to generate MR images with both morphological and functional information at 0.01 T. The signal-to-noise ratios found in the generated images were of the same order as, or better than, those obtained with the standard clinical routine.


Asunto(s)
Medios de Contraste/administración & dosificación , Compuestos Férricos , Gadolinio DTPA , Aumento de la Imagen/métodos , Hierro , Imagen por Resonancia Magnética , Óxidos , Oxígeno/metabolismo , Animales , Barrera Hematoencefálica , Encéfalo/anatomía & histología , Encéfalo/metabolismo , Medios de Contraste/farmacocinética , Compuestos Férricos/administración & dosificación , Compuestos Férricos/farmacocinética , Gadolinio DTPA/administración & dosificación , Gadolinio DTPA/farmacocinética , Inyecciones Intravenosas , Hierro/administración & dosificación , Hierro/farmacocinética , Riñón/anatomía & histología , Riñón/metabolismo , Hígado/anatomía & histología , Hígado/metabolismo , Masculino , Óxidos/administración & dosificación , Óxidos/farmacocinética , Consumo de Oxígeno , Ratas , Ratas Wistar , Sensibilidad y Especificidad , Marcadores de Spin