Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Biol Eng Comput ; 43(5): 686-92, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16411643

RESUMEN

The study presents the results of the development of an analyser to measure sulphur hexafluoride (SF6) gas in breathing circuits, for application is studies of lung function. The analyser consists of an in-line breathing circuit measurement transducer and a compact unit for signal treatment. The detector unit of the analyser consists of a near-infrared light source, a bandpass filter and a pyro-electrical detector. When incremental steps of SF6 gas between 0 and 2% were presented to the analyser, the maximum deviation from the theoretical calibration curve was calculated to be 0.01% SF6. The step response of the analyser (10-90%) was 250 ms. The sensitivity of the analyser to ambient temperature was 0.01% SF6 degrees C(-1) in the range between 0 and 2% SF6. It is concluded that the analyser presented is accurate, and has a sufficient response speed to be used in clinical measurement settings. Furthermore, the analyser is resistant to changes in temperature, gas flow, orientation and movement, which are likely to occur in clinical measurement settings.


Asunto(s)
Pruebas Respiratorias/métodos , Mediciones del Volumen Pulmonar/métodos , Hexafluoruro de Azufre , Pruebas Respiratorias/instrumentación , Electrónica Médica , Diseño de Equipo , Humanos , Espectroscopía Infrarroja Corta/métodos
2.
Biol Reprod ; 68(2): 536-42, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12533417

RESUMEN

The temporal relationship between changes in cervical dilatation, uterine electromyographic (EMG) activity, and maternal plasma concentrations of estradiol 17beta (E(2)), progesterone (P(4)), and 13,14-dihydro-15-keto-prostaglandin-F(2alpha) (PGFM), was investigated in six parturient cows. Calving was induced with a single injection of a synthetic analogue of prostaglandin F(2alpha) (PG) on Day 274 of gestation. Cervical dilatation was measured continuously by measuring the transit time between two implanted ultrasound crystals while at the same time uterine EMG activity was measured through two silver electrodes sutured on the myometrial surface until the expulsive stage of calving had been reached. In blood samples collected at 4-h intervals, starting at the moment of PG injection, the mean plasma E(2) concentration gradually increased and was significantly elevated at 28 h after PG injection. At 4 h after PG treatment, the mean P(4) concentration had dropped significantly and continued to decrease until a value of around 1 ng/ml was reached, where it stayed until the onset of expulsion. Mean plasma PGFM concentrations increased steadily after PG injection, reaching significantly elevated concentrations at 20 h after treatment. In the five cows that delivered calves in anterior positions, uterine EMG activity, expressed as root mean square (RMS in microV), started to increase at a mean interval (+/- SD) of 13.1 +/- 3.7 h following PG treatment. The increase in EMG activity was significantly correlated with changes in plasma PGFM concentrations. In these cows, dilatation of the caudal cervix started after a mean (+/- SD) interval of 28.5 +/- 1.5 h following PG treatment and dilatation progressed at a mean (+/- SD) rate of 2.25 +/- 0.24 cm/h. In one cow with a calf in the posterior position, uterine EMG activity and dilatation started at 15.8 h and 31.8 h, respectively, after induction of calving. We conclude that a predictable sequence of physiological changes occurs around induction of calving, which allows specific timing of future studies on cellular and biochemical changes within the cervix during parturition.


Asunto(s)
Dinoprost/análogos & derivados , Dinoprost/farmacología , Glándulas Endocrinas/fisiología , Primer Periodo del Trabajo de Parto , Oxitócicos/farmacología , Parto/fisiología , Útero/fisiología , Animales , Bovinos , Dinoprost/sangre , Electromiografía , Estradiol/sangre , Femenino , Concentración Osmolar , Embarazo , Resultado del Embarazo , Progesterona/sangre
3.
Theriogenology ; 57(8): 1989-2002, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12066860

RESUMEN

The objective of this study was to investigate the temporal changes in dilatation of the caudal cervix during induced calvings (n = 5). We used ultrasound cervimetry, allowing the continuous recording of the distance between a transmitting and receiving ultrasound crystal, which were implanted opposite to each other on the caudal rim of the cervix. We started recording between 19 and 21 h after injecting a prostaglandin analogue (PG) on day 272 of gestation. A fluid-filled catheter had been introduced transcervically between the fetal membranes and the uterine wall for measurements of intra-uterine pressure (IUP). While the characteristics of calving varied widely between the five animals, it appeared possible to divide the process of dilatation into four phases. During the latent phase, which lasted until 25-43 h after PG, no net gain in dilatation occurred. We found an acceleration phase (4.3-6.8 h), in which the dilatation rate speeds up (0.49-0.84 cm/h) in three of the cows. During the phase of maximum slope (lasting 0.5-4.8 h), we measured an even higher rate (1.47-8.48 cm/h), decreasing again during the deceleration phase (rate 0.24-2.28 cm/h) in four cows. The quality of the IUP measurements precluded us from continuously investigating the relationship between cervical dilatation and uterine contractions. However, short term simultaneous recordings revealed that the cervical opening changed momentarily in the absence of IUP during the latent phase, while during the phase of maximum slope, temporary changes of dilatation coincided with uterine contractions. We concluded that the method of ultrasound cervimetry used in this study provides a valuable way to study the process of cervical dilatation in parturient cows in vivo.


Asunto(s)
Bovinos/fisiología , Cuello del Útero/diagnóstico por imagen , Trabajo de Parto/fisiología , Animales , Cuello del Útero/fisiología , Femenino , Edad Gestacional , Embarazo , Factores de Tiempo , Ultrasonografía
4.
Scand J Urol Nephrol ; 30(4): 257-63, 1996 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8908644

RESUMEN

The aim of this research was to analyse variations in voided volumes and duration and time of voiding during daily activities on a physiological basis, and to explore the possible diagnostic value of the associated parameters. A small electronic device was developed to accurately measure voided urine volumes in healthy volunteers during consecutive periods of two to three weeks. In subsequent analysis, the voided volumes were related to the time interval between voidings and the duration of voiding. Three parameters could be identified that quantify different aspects of bladder capacity (modal volume, maximum volume and a threshold volume in the relation between average flow-rate and voided volume). By relating voided volumes to the time interval between voidings the circadian rhythm in urine production was detected.


Asunto(s)
Ritmo Circadiano/fisiología , Orina , Urodinámica/fisiología , Adulto , Anciano , Electrónica Médica/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Micción/fisiología , Urología/instrumentación
5.
Prosthet Orthot Int ; 19(1): 53-5, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7617459

RESUMEN

Long-term monitoring of walking in trans-tibial amputees (TTA) is considered important for prosthetic prescription and therapy evaluation. The purpose of this study was to develop a device with the following design criteria: lightweight, easy attachment to the prosthesis, energy and memory capacity for five days and practical in clinical use. The prototype (CAMP: Continuous Ambulatory Monitoring of Prosthetic walking) consists of a cylindrical unit containing an accelerometer, a miniature computer and six batteries. Specifications, data acquisition and processing, instructions for users and first results are presented and discussed. The CAMP prototype proved to be a useful device for measuring relevant aspects of prosthetic use for up to five days.


Asunto(s)
Amputados/rehabilitación , Monitoreo Ambulatorio/instrumentación , Prótesis e Implantes/rehabilitación , Diseño de Equipo , Humanos , Pierna , Monitoreo Ambulatorio/métodos , Tibia
6.
Physiol Behav ; 56(3): 597-601, 1994 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7972414

RESUMEN

A semiautomated three-compartment box (3CB) for studying partner preference behavior of rats is described. This apparatus automatically records the rat's time spent in each compartment, as well as the locomotor activity (i.e., the number of visits an animal pays to each compartment). Software was developed for calculating partner preference scores. Behavioral testing in the semiautomated 3CB, which is a modification of an earlier version, is less time consuming and less laborious. Three 3CBs can be observed simultaneously by two trained observers, and the behavioral interactions of three experimental animals with the stimulus animals can be observed and scored by hand. The use of the new apparatus was validated by studying adult partner preference behavior of neonatally ATD-treated male rats. The collected data fully corroborate previous results, obtained in the earlier version of the 3CB, again revealing the behavioral bisexual nature of these ATD males. A new finding was the much higher locomotor activity of the ATD males compared to controls.


Asunto(s)
Conducta de Elección , Actividad Motora , Psicofisiología/instrumentación , Conducta Sexual Animal , Procesamiento de Señales Asistido por Computador/instrumentación , Androstatrienos/farmacología , Animales , Conducta de Elección/efectos de los fármacos , Femenino , Masculino , Microcomputadores , Actividad Motora/efectos de los fármacos , Ratas , Ratas Wistar , Conducta Sexual Animal/efectos de los fármacos , Programas Informáticos
7.
Med Biol Eng Comput ; 28(4): 329-38, 1990 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2246932

RESUMEN

A new wheelchair ergometer has been designed in which a combination of realistic simulation of wheelchair propulsion--with adjustable parameters for rolling resistance, air drag, wind speed and slope--and force measurement has been realised. The static solution enables the measurement of physiological and kinesiological parameters. All data from force transducers in seat and backrest, torque transducers in the wheels and force transducers in the wheelframes as well as the acquired speed are sampled in a data-acquisition system. An offline curve processor allows the acquired data to be processed with standard or custom-programmed routines. Preliminary results have been added and are discussed.


Asunto(s)
Ingeniería , Silla de Ruedas , Matemática , Movimiento
8.
Ultrasonics ; 15(4): 183-5, 1977 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-878065

RESUMEN

This paper describes ultrasonic apparatus for continuous registration of cervical dilation during the first stage of labour. The techniques used ensure maximum safety for the patients and do not influence the normal birth process.


Asunto(s)
Cuello del Útero , Primer Periodo del Trabajo de Parto , Trabajo de Parto , Ultrasonido/instrumentación , Cuello del Útero/fisiología , Femenino , Humanos , Trabajo de Parto Inducido , Oxitocina/administración & dosificación , Embarazo , Contracción Uterina/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...