1.
Resuscitation ; 197: 110156, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38417611

RESUMEN

OBJECTIVES: To evaluate the use of newborn resuscitation timelines to assess the incidence, sequence, timing, duration of and response to resuscitative interventions. METHODS: A population-based observational study conducted June 2019-November 2021 at Stavanger University Hospital, Norway. Parents consented to participation antenatally. Newborns ≥28 weeks' gestation receiving positive pressure ventilation (PPV) at birth were enrolled. Time of birth was registered. Dry-electrode electrocardiogram was applied as soon as possible after birth and used to measure heart rate continuously during resuscitation. Newborn resuscitation timelines were generated from analysis of video recordings. RESULTS: Of 7466 newborns ≥28 weeks' gestation, 289 (3.9%) received PPV. Of these, 182 had the resuscitation captured on video, and were included. Two-thirds were apnoeic, and one-third were breathing ineffectively at the commencement of PPV. PPV was started at median (quartiles) 72 (44, 141) seconds after birth and continued for 135 (68, 236) seconds. The ventilation fraction, defined as the proportion of time from first to last inflation during which PPV was provided, was 85%. Interruption in ventilation was most frequently caused by mask repositioning and auscultation. Suctioning was performed in 35% of newborns, in 95% of cases after the initiation of PPV. PPV was commenced within 60 s of birth in 49% of apnoeic and 12% of ineffectively breathing newborns, respectively. CONCLUSIONS: Newborn resuscitation timelines can graphically present accurate, time-sensitive and complex data from resuscitations synchronised in time. Timelines can be used to enhance understanding of resuscitation events in data-guided quality improvement initiatives.


Asunto(s)
Salas de Parto , Resucitación , Embarazo , Recién Nacido , Humanos , Femenino , Respiración con Presión Positiva , Ventilación con Presión Positiva Intermitente , Edad Gestacional
3.
Artículo en Inglés | MEDLINE | ID: mdl-37940377

RESUMEN

OBJECTIVE: To determine the prevalence of bradycardia in the first minute after birth and association with positive pressure ventilation (PPV). METHOD: A population-based cross-sectional study was conducted from June 2019 to December 2021 at Stavanger University Hospital, Norway. Parents consented to participation during pregnancy, and newborns ≥28 weeks' gestation were included at birth. Heart rate (HR) was captured immediately after birth and continuously for the first minute(s). Time of birth was registered on a tablet. Provision of PPV was captured using video. RESULTS: Of 4876 included newborns, 164 (3.4%) did not breathe (two-thirds) or breathed ineffectively (one-third) and received PPV at birth. HR in the first minute had a wide distribution. The prevalence of first measured HR <100 and <60 beats/minute at median 16 s was 16.3% and 0.6%, respectively. HR increased in most cases. At 60 s, 3.7% had HR <100 beats/minute, of which 82% did not require PPV. In total, 25% of newborns had some registered HR <100 beats/minute during the first minute, of which 95% did not require PPV. Among newborns who received PPV, 76% and 62% had HR ≥100 beats/minute at 60 s and at start PPV, respectively. CONCLUSION: Bradycardia with HR <100 bpm in the first minute of life was frequent, but mostly self-resolved. Among the 4% of newborns that remained bradycardic at 60 s, only 20% received PPV. Two-thirds of resuscitated newborns had HR ≥100 beats/minute at start PPV. None of the ventilated newborns were breathing adequately at start PPV. TRIAL REGISTRATION NUMBER: NCT03849781.

4.
Children (Basel) ; 10(9)2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37761501

RESUMEN

Suctioning of newborns immediately after birth, as part of delivery room resuscitation, is only recommended if the airway is obstructed. The aim of this study was to describe the use of suctioning during newborn resuscitation among survivors versus those who died within 3 days and potential suction-related heart rate responses and associations to newborn characteristics. This was a retrospective observational study from July 2013 to July 2016 in a referral hospital in rural Tanzania. Research assistants observed and documented all deliveries, newborn resuscitations were video-recorded, and newborn heart rates were captured with a dry-electrode electrocardiogram. Liveborn infants ≥34 weeks gestation who received ventilation and with complete datasets were eligible. All 30 newborns who died were included, and a total of 46 survivors were selected as controls. Videos were annotated and heart rate patterns were observed before and after the suction events. Suctioning was performed more frequently than recommended. No differences were found in suctioning characteristics between newborns who died versus those who survived. In 13% of suction events, a significant heart rate change (i.e., arrhythmia or brief/sustained >15% fall in heart rate) was observed in relation to suctioning. This represents a potential additional harm to already depressed newborns undergoing resuscitation.

5.
Children (Basel) ; 10(7)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37508615

RESUMEN

BACKGROUND: Newborn resuscitation guidelines recommend positive pressure ventilation (PPV) for newborns who do not establish effective spontaneous breathing after birth. T-piece resuscitator systems are commonly used in high-resource settings and can additionally provide positive end-expiratory pressure (PEEP). Short expiratory time, high resistance, rapid dynamic changes in lung compliance and large tidal volumes increase the possibility of incomplete exhalation. Previous publications indicate that this may occur during newborn resuscitation. Our aim was to study examples of incomplete exhalations in term newborn resuscitation and discuss these against the theoretical background. METHODS: Examples of flow and pressure data from respiratory function monitors (RFM) were selected from 129 term newborns who received PPV using a T-piece resuscitator. RFM data were not presented to the user during resuscitation. RESULTS: Examples of incomplete exhalation with higher-than-set PEEP-levels were present in the recordings with visual correlation to factors affecting time needed to complete exhalation. CONCLUSIONS: Incomplete exhalation and the relationship to expiratory time constants have been well described theoretically. We documented examples of incomplete exhalations with increased PEEP-levels during resuscitation of term newborns. We conclude that RFM data from resuscitations can be reviewed for this purpose and that incomplete exhalations should be further explored, as the clinical benefit or risk of harm are not known.

6.
Children (Basel) ; 10(7)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37508621

RESUMEN

BACKGROUND: European guidelines recommend the use of pulse oximetry (PO) during newborn resuscitation, especially when there is a need for positive pressure ventilation or supplemental oxygen. The objective was to evaluate (i) to what extent PO was used, (ii) the time and resources spent on the application of PO, and (iii) the proportion of time with a useful PO signal during newborn resuscitation. METHODS: A prospective observational study was conducted at Stavanger University Hospital, Norway, between 6 June 2019 and 16 November 2021. Newborn resuscitations were video recorded, and the use of PO during the first ten minutes of resuscitation was recorded and analysed. RESULTS: Of 7466 enrolled newborns, 289 (3.9%) received ventilation at birth. The resuscitation was captured on video in 230 cases, and these newborns were included in the analysis. PO was applied in 222 of 230 (97%) newborns, median (quartiles) 60 (24, 58) seconds after placement on the resuscitation table. The proportion of time used on application and adjustments of PO during ongoing ventilation and during the first ten minutes on the resuscitation table was 30% and 17%, respectively. Median two healthcare providers were involved in the PO application. Video of the PO monitor signal was available in 118 (53%) of the 222 newborns. The proportion of time with a useful PO signal during ventilation and during the first ten minutes on the resuscitation table was 5% and 35%, respectively. CONCLUSION: In total, 97% of resuscitated newborns had PO applied, in line with resuscitation guidelines. However, the application of PO was time-consuming, and a PO signal was only obtained 5% of the time during positive pressure ventilation.

7.
Children (Basel) ; 10(4)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37189901

RESUMEN

There is a substantial gap in our understanding of resuscitation practices following Helping Babies Breathe (HBB) training. We sought to address this gap through an analysis of observed resuscitations following HBB 2nd edition training in the Democratic Republic of the Congo. This is a secondary analysis of a clinical trial evaluating the effect of resuscitation training and electronic heart rate monitoring on stillbirths. We included in-born, liveborn neonates ≥28 weeks gestation whose resuscitation care was directly observed and documented. For the 2592 births observed, providers dried/stimulated before suctioning in 97% of cases and suctioned before ventilating in 100%. Only 19.7% of newborns not breathing well by 60 s (s) after birth ever received ventilation. Providers initiated ventilation at a median 347 s (>five minutes) after birth; no cases were initiated within the Golden Minute. During 81 resuscitations involving ventilation, stimulation and suction both delayed and interrupted ventilation with a median 132 s spent drying/stimulating and 98 s suctioning. This study demonstrates that HBB-trained providers followed the correct order of resuscitation steps. Providers frequently failed to initiate ventilation. When ventilation was initiated, it was delayed and interrupted by stimulation and suctioning. Innovative strategies targeting early and continuous ventilation are needed to maximize the impact of HBB.

8.
BMJ Paediatr Open ; 7(1)2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37028906

RESUMEN

BACKGROUND: Stimulating infants to elicit a cry at birth is common but could result in unnecessary handling. We evaluated heart rate in infants who were crying versus non-crying but breathing immediately after birth. METHODS: This was single-centre observational study of singleton, vaginally born infants at ≥33 weeks of gestation. Infants who were crying or non-crying but breathing within 30 s after birth were included. Background demographic data and delivery room events were recorded using tablet-based applications and synchronised with continuous heart rate data recorded by a dry-electrode electrocardiographic monitor. Heart rate centile curves for the first 3 min of life were generated with piecewise regression analysis. Odds of bradycardia and tachycardia were compared using multiple logistic regression. RESULTS: 1155 crying and 54 non-crying but breathing neonates were included in the final analyses. There were no significant differences in the demographic and obstetric factors between the cohorts. Non-crying but breathing infants had higher rates of early cord clamping <60 s after birth (75.9% vs 46.5%) and admission to the neonatal intensive care unit (13.0% vs 4.3%). There were no significant differences in median heart rates between the cohorts. Non-crying but breathing infants had higher odds of bradycardia (heart rate <100 beats/min, adjusted OR 2.64, 95% CI 1.34 to 5.17) and tachycardia (heart rate ≥200 beats/min, adjusted OR 2.86, 95% CI 1.50 to 5.47). CONCLUSION: Infants who are quietly breathing but do not cry after birth have an increased risk of both bradycardia and tachycardia, and admission to the neonatal intensive care unit. TRIAL REGISTRATION NUMBER: ISRCTN18148368.


Asunto(s)
Llanto , Frecuencia Cardíaca , Parto , Respiración , Humanos , Masculino , Femenino , Recién Nacido , Embarazo , Adulto , Llanto/fisiología , Frecuencia Cardíaca/fisiología , Bradicardia , Taquicardia , Unidades de Cuidado Intensivo Neonatal , Resucitación
9.
Acta Paediatr ; 112(4): 697-705, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36607256

RESUMEN

AIM: The aim was to study the prevalence of bradycardia at birth in newborns requiring positive pressure ventilation (PPV), distribution of first measured heart rate (HR), changes in HR before start of PPV and HR response to PPV. METHODS: A population-based study including newborns ≥30 weeks' gestation receiving PPV at birth. HR was captured immediately after birth and continuously throughout resuscitation using the dry-electrode ECG device NeoBeat. Time of birth was registered in the Liveborn app. Provision of PPV was captured by video. RESULTS: We included 98 newborns receiving PPV at birth. Among newborns with HR measured within 60 s after birth, median (quartiles) first HR was 112 (84, 149) bpm recorded 19 (14, 37) s after birth, of which 33% had first HR <100 and 10% had first HR <60 bpm respectively. First HR was widely distributed. Median HR at start PPV 69 s after birth was 129 bpm. In newborns with an initial low HR, HR typically remained low for 20 s of PPV before increasing rapidly over the next 20-30 s. CONCLUSIONS: First measured HR was ≥100 bpm in two thirds of newborns receiving PPV. In bradycardic infants, HR did not increase until after 20 s of PPV.


Asunto(s)
Respiración con Presión Positiva , Resucitación , Lactante , Femenino , Recién Nacido , Humanos , Frecuencia Cardíaca/fisiología , Ventilación con Presión Positiva Intermitente , Bradicardia
10.
J Perinatol ; 43(6): 709-715, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36587054

RESUMEN

OBJECTIVE: To compare HR pattern of vigorous newborns during the first 180 s with early (≤60 s, ECC) or delayed (>60 s, DCC) cord clamping. STUDY DESIGN: Observational study including dry-electrode ECG monitoring of 610 vaginally-born singleton term and late-preterm (≥34 weeks) who were vigorous after birth. RESULTS: 198 received ECC while 412 received DCC with median cord clamping at 37 s and 94 s. Median HR remained stable from 30 to 180 s with DCC (172 and 170 bpm respectively) but increased with ECC (169 and 184 bpm). The proportion with bradycardia was higher among ECC than DCC at 30 s and fell faster in the DCC through 60 s. After adjusting for factors affecting timing of cord clamping, ECC had significant risk of bradycardia compared to DCC (aRR 1.51; 95% CI; 1.01-2.26). CONCLUSION: Early heart instability and higher risk of bradycardia with ECC as compared to DCC supports the recommended clinical practice of DCC.


Asunto(s)
Bradicardia , Parto Obstétrico , Embarazo , Femenino , Recién Nacido , Humanos , Lactante , Parto Obstétrico/efectos adversos , Bradicardia/epidemiología , Bradicardia/etiología , Clampeo del Cordón Umbilical , Constricción , Cordón Umbilical
11.
Adv Simul (Lond) ; 7(1): 38, 2022 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-36335400

RESUMEN

BACKGROUND: Annually, 1.5 million intrapartum-related deaths occur; fresh stillbirths and early newborn deaths. Most of these deaths are preventable with skilled ventilation starting within the first minute of life. Helping Babies Breathe is an educational program shown to improve simulated skills in newborn resuscitation. However, translation into clinical practice remains a challenge. The aim was to describe changes in clinical resuscitation and perinatal outcomes (i.e., fresh stillbirths and 24-h newborn deaths) after introducing a novel simulator (phase 1) and then local champions (phase 2) to facilitate ongoing Helping Babies Breathe skill and scenario simulation training. METHODS: This is a 3-year prospective before/after (2 phases) clinical observational study in Tanzania. Research assistants observed all deliveries from September 2015 through August 2018 and recorded labor/newborn information and perinatal outcomes. A novel simulator with automatic feedback to stimulate self-guided skill training was introduced in September 2016. Local champions were introduced in October 2017 to motivate midwives for weekly training, also team simulations. RESULTS: The study included 10,481 births. Midwives had practiced self-guided skill training during the last week prior to a real newborn resuscitation in 34% of cases during baseline, 30% in phase 1, and 71% in phase 2. Most real resuscitations were provided by midwives, increasing from 66% in the baseline, to 77% in phase 1, and further to 83% in phase 2. The median time from birth to first ventilation decreased between baseline and phase 2 from 118 (85-165) to 101 (72-150) s, and time pauses during ventilation decreased from 28 to 16%. Ventilations initiated within the first minute did not change significantly (13-16%). The proportion of high-risk deliveries increased during the study period, while perinatal mortality remained unchanged. CONCLUSIONS: This study reports a gradual improvement in real newborn resuscitation skills after introducing a novel simulator and then local champions. The frequency of trainings increased first after the introduction of motivating champions. Time from birth to first ventilation decreased; still, merely 16% of newborns received ventilation within the first minute as recommended. This is a remaining challenge that may require more targeted team-scenario training and quality improvement efforts to improve.

12.
Front Pediatr ; 10: 943496, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36245737

RESUMEN

Background: 900,000 newborns die from respiratory depression each year; nearly all of these deaths occur in low- and middle-income countries. Deaths from respiratory depression are reduced by evidence-based resuscitation. Electronic heart rate monitoring provides a sensitive indicator of the neonate's status to inform resuscitation care, but is infrequently used in low-resource settings. In a recent trial in the Democratic Republic of the Congo, midwives used a low-cost, battery-operated heart rate meter (NeoBeat) to continuously monitor heart rate during resuscitations. We explored midwives' perceptions of NeoBeat including its utility and barriers and facilitators to use. Methods: After a 20-month intervention in which midwives from three facilities used NeoBeat during resuscitations, we surveyed midwives and conducted focus group discussions (FGDs) regarding the incorporation of NeoBeat into clinical care. FGDs were conducted in Lingala, the native language, then transcribed and translated from Lingala to French to English. We analyzed data by: (1) coding of transcripts using Nvivo, (2) comparison of codes to identify patterns in the data, and (3) grouping of codes into categories by two independent reviewers, with final categories determined by consensus. Results: Each midwife from Facility A used NeoBeat on an estimated 373 newborns, while each midwife at facilities B and C used NeoBeat an average 24 and 47 times, respectively. From FGDs with 30 midwives, we identified five main categories of perceptions and experiences regarding the use of NeoBeat: (1) Providers' initial skepticism evolved into pride and a belief that NeoBeat was essential to resuscitation care, (2) Providers viewed NeoBeat as enabling their resuscitation and increasing their capacity, (3) NeoBeat helped providers identify flaccid newborns as liveborn, leading to hope and the perception of saving of lives, (4) Challenges of use of NeoBeat included cleaning, charging, and insufficient quantity of devices, and (5) Providers desired to continue using the device and to expand its use beyond resuscitation and their own facilities. Conclusion: Midwives perceived that NeoBeat enabled their resuscitation practices, including assisting them in identifying non-breathing newborns as liveborn. Increasing the quantity of devices per facility and developing systems to facilitate cleaning and charging may be critical for scale-up.

13.
Children (Basel) ; 9(1)2022 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-35053679

RESUMEN

BACKGROUND: ST-segment changes to the fetal electrocardiogram (ECG) may indicate fetal acidosis. No large-scale characterization of ECG morphology immediately after birth has been performed, but ECG is used for heart rate (HR) assessment. We aimed to investigate ECG morphology immediately after birth in asphyxiated infants, using one-lead dry-electrode ECG developed for HR measurement. METHODS: Observational study in Tanzania, between 2013-2018. Near-term and term infants that received bag-mask ventilation (BMV), and healthy controls, were monitored with one-lead dry-electrode ECG with a non-diagnostic bandwidth. ECGs were classified as normal, with ST-elevations or other ST-segment abnormalities including a biphasic ST-segment. We analyzed ECG morphology in relation to perinatal variables or short-term outcomes. RESULTS: A total of 494 resuscitated and 25 healthy infants were included. ST-elevations were commonly seen both in healthy infants (7/25; 28%) and resuscitated (320/494; 65%) infants. The apparent ST-elevations were not associated with perinatal variables or short-term outcomes. Among the 32 (6.4%) resuscitated infants with "other ST-segment abnormalities", duration of BMV was longer, 1-min Apgar score lower and normal outcomes less frequent than in the resuscitated infants with normal ECG or ST-elevations. CONCLUSIONS: ST-segment elevation was commonly seen and not associated with negative outcomes when using one-lead dry-electrode ECG. Other ST-segment abnormalities were associated with prolonged BMV and worse outcome. ECG with appropriate bandwidth and automated analysis may potentially in the future aid in the identification of severely asphyxiated infants.

14.
Resuscitation ; 171: 57-63, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34965451

RESUMEN

AIM: To evaluate the effect of resuscitation training and continuous electronic heart rate (HR) monitoring of non-breathing newborns on identification of stillbirth. METHODS: We conducted a pre-post interventional trial in three health facilities in the Democratic Republic of the Congo. We collected data on a retrospective control group of newborns that reflected usual resuscitation practice (Epoch 1). In the prospective, interventional group, skilled birth attendants received resuscitation training in Helping Babies Breathe and implemented continuous electronic HR monitoring of non-breathing newborns (Epoch 2). Our primary outcome was the incidence of stillbirth with secondary outcomes of fresh or macerated stillbirth, neonatal death before discharge and perinatal death. Among a subset, we conducted expert review of electronic HR data to estimate misclassification of stillbirth in Epoch 2. We used a generalized estimating equation, adjusted for variation within-facility, to compare risks between EPOCHs. RESULTS: There was no change in total stillbirths following resuscitation training and continuous electronic HR monitoring of non-breathing newborns (aRR 1.15 [0.95, 1.39]). We observed an increased rate of macerated stillbirth (aRR 1.58 [1.24, 2.02]), death before discharge (aRR 3.31 [2.41, 4.54]), and perinatal death (aRR 1.61 [1.38, 1.89]) during the intervention period. In expert review, 20% of newborns with electronic HR data that were classified by SBAs as stillborn were liveborn. CONCLUSION: Resuscitation training and use of continuous electronic HR monitoring did not reduce stillbirths nor eliminate misclassification.


Asunto(s)
Resucitación , Mortinato , Electrónica , Femenino , Frecuencia Cardíaca , Humanos , Lactante , Recién Nacido , Embarazo , Estudios Prospectivos , Resucitación/educación , Estudios Retrospectivos , Mortinato/epidemiología
15.
BMJ Open ; 12(9): e061839, 2022 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-36691167

RESUMEN

INTRODUCTION: 3%-8% of newborns need positive pressure ventilation (PPV) after birth. Heart rate (HR) is considered the most sensitive indicator of the newborns' condition and response to resuscitative interventions. According to guidelines, HR should be assessed and PPV initiated within 60 s after birth in non-breathing newborns. Dry electrode ECG can provide accurate feedback on HR immediately after birth and continuously during resuscitation. The impact of early and continuous HR feedback is unknown. METHOD AND ANALYSIS: This single-centre randomised controlled trial seeks to determine if HR feedback by dry electrode ECG immediately after birth and continuously during newborn resuscitation results in more timely initiation of PPV, improved ventilation and short-term outcomes compared with standard HR assessment.In all newborns≥34 gestational weeks, the dry electrode ECG sensor is placed on the upper abdomen immediately after birth as an additional modality of HR assessment. The device records and stores HR signals. In intervention subjects, the HR display is visible to guide decision-making and further management, in control subjects the display is masked. Standard HR assessment is by stethoscope, gel-electrode ECG and/or pulse oximetry (PO).Time of birth is registered in the Liveborn app. Time of initiation and duration of PPV is calculated from video recordings. Ventilation parameters are retrieved from the ventilation monitor, oxygen saturation and HR from the PO and gel-electrode ECG monitors.The primary endpoint is proportion of resuscitated newborns who receive PPV within 60 s after birth. To detect a 50% increase with power of 90% using an overall significance level of 0.05 and 1 interim analysis, 169 newborns are needed in each group. ETHICS AND DISSEMINATION: Approval by the Norwegian National Research Ethics Committee West (2018/338). Parental consent is sought at routine screening early in pregnancy. The results will be published in peer-reviewed journal and presented at conferences. TRIAL REGISTRATION NUMBER: NCT03849781.


Asunto(s)
Electrocardiografía , Respiración , Embarazo , Femenino , Recién Nacido , Humanos , Frecuencia Cardíaca/fisiología , Retroalimentación , Electrodos , Ensayos Clínicos Controlados Aleatorios como Asunto
16.
Children (Basel) ; 8(12)2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34943288

RESUMEN

BACKGROUND: Assessment of heart rate (HR) is essential during newborn resuscitation, and comparison of dry-electrode ECG technology to standard monitoring by 3-lead ECG and Pulse Oximetry (PO) is lacking. METHODS: NeoBeat, ECG, and PO were applied to newborns resuscitated at birth. Resuscitations were video recorded, and HR was registered every second. RESULTS: Device placement time from birth was median (quartiles) 6 (4, 18) seconds for NeoBeat versus 138 (97, 181) seconds for ECG and 152 (103, 216) seconds for PO. Time to first HR presentation from birth was 22 (13, 45) seconds for NeoBeat versus 171 (129, 239) seconds for ECG and 270 (185, 357) seconds for PO. Proportion of time with HR feedback from NeoBeat during resuscitation from birth was 85 (69, 93)%, from arrival at the resuscitation table 98 (85, 100)%, and during positive pressure ventilation 100 (95, 100)%. For ECG, these proportions were, 25 (0, 43)%, 28 (0, 56)%, and 33 (0, 66)% and for PO, 0 (0, 16)%, 0 (0, 16)%, and 0 (0, 18)%. All p < 0.0001. CONCLUSIONS: NeoBeat was faster to place, presented HR more rapidly, and provided feedback on HR for a larger proportion of time during ongoing resuscitation compared to 3-lead ECG and PO.

17.
Resuscitation ; 166: 121-128, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34098031

RESUMEN

AIM: To explore and compare expired CO2 (ECO2) and heart rate (HR), during newborn resuscitation with bag-mask ventilation, as predictors of 24-h outcome. METHODS: Observational study from March 2013 to June 2017 in a rural Tanzanian hospital. Side-stream measures of ECO2, ventilation parameters, HR, clinical information, and 24-h outcome were recorded in live born bag-mask ventilated newborns with initial HR < 120 bpm. We analysed the data using logistic regression models and compared areas under the receiver operating curves (AUC) for ECO2 and HR within three selected time intervals after onset of ventilation (0-30 s, 30.1-60 s and 60.1-300 s). RESULTS: Among 434 included newborns (median birth weight 3100 g), 378 were alive at 24 h, 56 had died. Both ECO2 and HR were independently significant predictors of 24-h outcome, with no differences in AUCs. In the first 60 s of ventilation, ECO2 added extra predictive information compared to HR alone. After 60 s, ECO2 lost significance when adjusted for HR. In 70% of newborns with initial ECO2 <2% and HR < 100 bpm, ECO2 reached ≥2% before HR ≥ 100 bpm. Survival at 24 h was reduced by 17% per minute before ECO2 reached ≥2% and 44% per minute before HR reached ≥100 bpm. CONCLUSIONS: Higher levels and a faster rise in ECO2 and HR during newborn resuscitation were independently associated with improved survival compared to persisting low values. ECO2 increased before HR and may serve as an earlier predictor of survival.


Asunto(s)
Dióxido de Carbono , Resucitación , Peso al Nacer , Espiración , Humanos , Recién Nacido , Respiración con Presión Positiva
18.
BMC Res Notes ; 14(1): 166, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33933159

RESUMEN

OBJECTIVE: To compare the accuracy of heart rate detection properties of a novel, wireless, dry-electrode electrocardiogram (ECG) device, NeoBeat®, to that of a conventional 3-lead gel-electrode ECG monitor (PropaqM®) in newborns. RESULTS: The study population had a mean gestational age of 39 weeks and 2 days (1.5 weeks) and birth weight 3528 g (668 g). There were 950 heart rate notations from each device, but heart rate was absent from the reference monitor in 14 of these data points, leaving 936 data pairs to compare. The mean (SD) difference when comparing NeoBeat to the reference monitor was -0.25 (9.91) beats per minute (bpm) (p = 0.44). There was a deviation of more than 10 bpm in 7.4% of the data pairs, which primarily (78%) was attributed to ECG signal disturbance, and secondly (22%) due to algorithm differences between the devices. Excluding these outliers, the correlation was equally consistent (r2 = 0.96) in the full range of heart rate captured measurements with a mean difference of - 0.16 (3.09) bpm. The mean difference was less than 1 bpm regardless of whether outliers were included or not.


Asunto(s)
Electrocardiografía , Electrodos , Edad Gestacional , Frecuencia Cardíaca , Humanos , Lactante , Recién Nacido , Monitoreo Fisiológico
19.
Arch Dis Child Fetal Neonatal Ed ; 106(3): 311-315, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33172876

RESUMEN

OBJECTIVE: To determine heart rate centiles during the first 5 min after birth in healthy term newborns delivered vaginally with delayed cord clamping. DESIGN: Single-centre prospective observational study. SETTING: Stavanger University Hospital, Norway, March-August 2019. PATIENTS: Term newborns delivered vaginally were eligible for inclusion. Newborns delivered by vacuum or forceps or who received any medical intervention were excluded. INTERVENTIONS: A novel dry electrode electrocardiography monitor (NeoBeat) was applied to the newborn's chest immediately after birth. The newborns were placed on their mother's chest or abdomen, dried and stimulated, and cord clamping was delayed for at least 1 min. MAIN OUTCOME MEASURES: Heart rate was recorded at 1 s intervals, and the 3rd, 10th, 25th, 50th, 75th, 90th and 97th centiles were calculated from 5 s to 5 min after birth. RESULTS: 898 newborns with a mean (SD) birth weight 3594 (478) g and gestational age 40 (1) weeks were included. The heart rate increased rapidly from median (IQR) 122 (98-146) to 168 (146-185) beats per minute (bpm) during the first 30 s after birth, peaking at 175 (157-189) bpm at 61 s after birth, and thereafter slowly decreasing. The third centile reached 100 bpm at 34 s, suggesting that heart rates <100 bpm during the first minutes after birth are uncommon in healthy newborns after delayed cord clamping. CONCLUSION: This report presents normal heart rate centiles from 5 s to 5 min after birth in healthy term newborns delivered vaginally with delayed cord clamping.


Asunto(s)
Parto Obstétrico , Electrocardiografía , Frecuencia Cardíaca/fisiología , Parto/fisiología , Tiempo de Tratamiento/normas , Cordón Umbilical , Peso al Nacer , Constricción , Parto Obstétrico/métodos , Parto Obstétrico/estadística & datos numéricos , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Femenino , Edad Gestacional , Humanos , Recién Nacido , Masculino , Noruega/epidemiología , Evaluación de Procesos y Resultados en Atención de Salud , Valores de Referencia
20.
BMC Pregnancy Childbirth ; 20(1): 756, 2020 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-33272242

RESUMEN

BACKGROUND: Simulation-based training in neonatal resuscitation is more effective when reinforced by both practice and continuous improvement processes. We aim to evaluate the effectiveness of a quality improvement program combined with an innovative provider feedback device on neonatal resuscitation practice and outcomes in a public referral hospital of Nepal. METHODS: A pre- and post-intervention study will be implemented in Pokhara Academy of Health Sciences, a hospital with 8610 deliveries per year. The intervention package will include simulation-based training (Helping Babies Breathe) enhanced with a real-time feedback system (the NeoBeat newborn heart rate meter with the NeoNatalie Live manikin and upright newborn bag-mask with PEEP) accompanied by a quality improvement process. An independent research team will collect perinatal data and conduct stakeholder interviews. DISCUSSION: This study will provide further information on the efficiency of neonatal resuscitation training and implementation in the context of new technologies and quality improvement processes. TRIAL REGISTRATION: https://doi.org/10.1186/ISRCTN18148368 , date of registration-31 July 2018.


Asunto(s)
Asfixia Neonatal/terapia , Resucitación/educación , Entrenamiento Simulado/organización & administración , Retroalimentación , Femenino , Humanos , Recién Nacido , Maniquíes , Nepal , Embarazo , Mejoramiento de la Calidad , Centros de Atención Terciaria