Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Comput Tomogr ; 6(6): 422-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23217463

RESUMEN

BACKGROUND: In transcatheter aortic valve implantation (TAVI), optimal selection of fluoroscopic projections that permit orthogonal visualization of the aortic valve plane is important but may be difficult to achieve. OBJECTIVE: We developed and validated a simple method to predict suitable fluoroscopic projections on the basis of cardiac CT datasets. METHODS: In 75 consecutive patients that underwent TAVI, angulations in which a 35-mm thick maximum intensity projection would render all aortic valve calcium into 1 plane were determined by manual interaction with contrast-enhanced dual-source CT datasets. TAVI operators used the predicted angulation for the first aortic angiogram and performed additional aortic angiograms if no satisfactory view of the aortic valve plane was obtained. Predicted angulations were compared with the angulation used for valve implantation. Radiation exposure and contrast use was compared between patients with accurate prediction of fluoroscopic angulations by CT and patients in whom CT failed to predict a suitable view. RESULTS: The mean difference between the predicted angulation according to CT and the angulation used for implantation was 3 ± 6 degrees. CT predicted a suitable angulation (<5-degree deviation) in 63 of 75 cases (84%). The mean number of aortic angiograms acquired in patients with correct prediction (1.02 ± 0.1) was significantly lower than in patients with incorrect prediction of the implantation angle by CT (3.0 ± 1.7; P < 0.001). Contrast agent required for the entire TAVI procedure was lower in patients with correct prediction (72 ± 36 mL vs 106 ± 39 mL; P = 0.001). CONCLUSION: CT permits prediction of suitable angulations for TAVI in most cases.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Fluoroscopía/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Intensificación de Imagen Radiográfica/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Artículo en Alemán | MEDLINE | ID: mdl-22147612

RESUMEN

Understanding the principles of wave physics paves the way for appropriate utilization and interpretation of sonography. In module 1 of the course series "Anesthesia Focused Sonography", the course participants will learn by lectures and practical training, how ultrasonic waves emerge, how they travel in human tissue, and how a picture is generated from their echo signals. Furthermore, the technology of an ultrasound system and the development of artifacts will be demonstrated; moreover, the Doppler effect and its implementation into current sonographic procedures will be presented as a central theme.


Asunto(s)
Anestesia/métodos , Artefactos , Aumento de la Imagen/métodos , Monitoreo Intraoperatorio/métodos , Ultrasonografía Intervencional/métodos , Humanos
3.
JACC Cardiovasc Interv ; 3(11): 1126-32, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21087747

RESUMEN

OBJECTIVES: This study assessed the rate of periprocedural embolic ischemic brain injury during transapical aortic valve replacement in 25 consecutive patients. BACKGROUND: Transcatheter aortic valve implantation is rapidly being established as a new therapeutic approach for aortic valve stenosis. Although initial clinical results are promising, it is unknown whether mobilization and embolization of calcified particles may lead to cerebral ischemia. METHODS: Twenty-five consecutive patients (10 men, 15 women, mean age: 81 ± 5 years, mean log EuroSCORE [European System for Cardiac Operative Risk Evaluation]: 32 ± 10%) scheduled for transapical aortic valve implantation were included. All patients received a baseline cerebral magnetic resonance imaging scan. The scan was repeated approximately 6 days after valve implantation. The magnetic resonance imaging studies included axial diffusion-weighted, T(2)-weighted, fluid attenuated inversion recovery-weighted, and T(2) gradient echo sequences. Standardized assessment of the neurologic status was performed before aortic valve replacement and post-operatively. RESULTS: Transapical aortic valve implantation was successfully performed in all patients. In 17 patients (68%), new cerebral lesions could be detected, whereas 8 patients showed no new cerebral insults. The pattern of distribution and morphology were typical of embolic origin. Despite the high incidence of morphologically detectable lesions, only 5 patients showed clinical neurologic alterations. Out of these patients, only 1 suffered from a permanent stroke. CONCLUSIONS: New embolic ischemic cerebral insults are detected in 68% of patients after transapical valve implantation. Clinical symptoms are rare and usually transitory. Larger trials will need to establish the clinical significance of asymptomatic ischemic lesions as well as the rate of ischemic events in patients undergoing transfemoral valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Isquemia Encefálica/diagnóstico , Cateterismo Cardíaco/efectos adversos , Imagen de Difusión por Resonancia Magnética , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Embolia Intracraneal/diagnóstico , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/etiología , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Embolia Intracraneal/etiología , Masculino , Examen Neurológico , Valor Predictivo de las Pruebas , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Toracotomía , Factores de Tiempo , Resultado del Tratamiento
4.
Int J Fertil Womens Med ; 52(1): 11-26, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17987884

RESUMEN

Ovarian hyperstimulation syndrome (OHSS) is a rare and potentially life-threatening complication during controlled ovarian stimulation. It can be associated with severe morbidity and may even be fatal. The etiology of the condition and predisposing factors are still not fully understood. Data concerning pathophysiology in patients with OHSS were searched using PubMed and other medical data bases. The incidence of severe OHSS, as calculated by World Health Organization (WHO), is 0.2-1% of all stimulation cycles in assisted reproduction. Considerations on OHSS classifications and forms of manifestations are discussed in detail. New insights concerning genetics and altered FSH receptor are given. OHSS may involve, according to its grade of severity, elevated or decreased levels of growth factors, cytokines, mediators, changes in hormones, renin-angiotensin and kinin-kallikrein system. There are massive electrolytic imbalances and changes in hemodynamic and fluid metabolism. Furthermore, liver and pulmonary dysfunction is observed as well as increased coagulation with subsequent thromboembolism. The influence of OHSS on the pregnancy rate and outcome of pregnancy is a matter of controversy. Patients with OHSS have high pregnancy rates with a tendency to an increased incidence of abortion.


Asunto(s)
Síndrome de Hiperestimulación Ovárica , Salud de la Mujer , Citocinas/metabolismo , Selectina E/metabolismo , Factores de Crecimiento Endotelial/metabolismo , Femenino , Humanos , Molécula 1 de Adhesión Intercelular/metabolismo , Péptidos y Proteínas de Señalización Intercelular/metabolismo , Síndrome de Hiperestimulación Ovárica/clasificación , Síndrome de Hiperestimulación Ovárica/etiología , Síndrome de Hiperestimulación Ovárica/terapia , Inducción de la Ovulación/efectos adversos , Renina/metabolismo , Sistema Renina-Angiotensina , Molécula 1 de Adhesión Celular Vascular/metabolismo , Organización Mundial de la Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA