Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Minerva Anestesiol ; 90(9): 748-758, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39279481

RESUMEN

BACKGROUND: We hypothesized that ultrasound-guided selective nerve root block could play a role in the prediction of clinical outcomes in patients with multilevel cervical disease following selective anterior cervical discectomy and fusion. METHODS: Patients were randomized to receive ultrasound-guided selected nerve root block as a diagnostic tool (study group) or not (control group), but both groups had surgery. Pain evaluation for arm and neck pain was recorded. The Visual Analog Scale (VAS) pain scores, Neck Disability Index, and MRI results were compared between groups. They were assessed every two weeks for three months, postoperatively. The percentage of patients who showed ≥ 50% reduction in their pain levels and a VAS rating of ≤2 was deemed an acceptable surgical outcome. RESULTS: Patients in the study group had significantly lower VAS scores for pain intensity than control patients at nearly all periods. This baseline pain improved significantly in the study group. A more significant proportion of patients in the study group showed a ≥50% reduction in their pain scores from baseline at weeks four, eight, and 12, and this difference was significantly lower than in the control group (P<0.05). The study group improved significantly over baseline in Neck Disability Index scores compared to control patients. Patients were highly satisfied with no significant adverse events in the study group. CONCLUSIONS: In patients with multilevel cervical disease, ultrasound-guided selective nerve root block is an excellent, safe, non-radiating, and reliable test to determine the appropriate level for operation.


Asunto(s)
Vértebras Cervicales , Discectomía , Bloqueo Nervioso , Ultrasonografía Intervencional , Humanos , Femenino , Masculino , Persona de Mediana Edad , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Adulto , Bloqueo Nervioso/métodos , Método Simple Ciego , Resultado del Tratamiento , Dimensión del Dolor , Desplazamiento del Disco Intervertebral/cirugía , Raíces Nerviosas Espinales/diagnóstico por imagen , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen
2.
J Contemp Dent Pract ; 24(9): 679-687, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38152942

RESUMEN

AIM: To evaluate the effect of low-intensity pulsed ultrasound (LIPU) application on dental implant accelerated osseointegration in the two-stage implant protocol. MATERIALS AND METHODS: A total of 20 implants were placed in 10 mature mongrel dogs, two implants for each dog replacing the lower 3rd premolars bilaterally. After 3 months of extraction, implants were placed. After 24 hours of implantation, the right sides received LIPU for 20 mins/day, continuously for 20 days. The left sides didn't receive LIPU (control). Standardized radiographs were taken before LIPU and after 10 and 20 days for both sides. After 20 days of LIPU application, second-stage surgery was performed and provisional crowns were placed on each implant. Implants were subjected to functional occlusal loading for 4 weeks. Standardized radiographs were taken after 2 and 4 weeks of loading and analyzed to assess the peri-implant bone density changes. All data were collected, tabulated, and statistically analyzed. RESULTS: All tissues appeared clinically normal, with the absence of inflammation and peri-implant radiolucency. The survival rate was 100%. The LIPU group showed a statistically significantly higher percentage increase in mean bone density after 10 LIPU sessions, 20 LIPU sessions, and 2 and 4 weeks of loading, than a control group. CONCLUSION: The LIPU stimulation radiographically increased the bone density around implant area and accelerated osseointegration in the two-stage implant protocol. CLINICAL SIGNIFICANCE: Low-intensity pulsed ultrasound stimulation could be beneficial in accelerating osseointegration and thus shortening the waiting period for final prosthetic delivery.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Animales , Perros , Implantación Dental Endoósea/métodos , Oseointegración/fisiología , Radiografía , Ondas Ultrasónicas , Prótesis Dental de Soporte Implantado , Coronas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA