Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J AOAC Int ; 93(4): 1180-91, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20922950

RESUMEN

Three stability-indicating assay methods were developed for the determination of tropisetron in a pharmaceutical dosage form in the presence of its degradation products. The proposed techniques are HPLC, TLC, and first-derivative spectrophotometry (1D). Acid degradation was carried out, and the degradation products were separated by TLC and identified by IR, NMR, and MS techniques. The HPLC method was based on determination of tropisetron in the presence of its acid-induced degradation product on an RP Nucleosil C18 column using methanol-water-acetonitrile-trimethylamine (65 + 20 + 15 + 0.2, v/v/v/v) mobile phase and UV detection at 285 nm. The TLC method was based on the separation of tropisetron and its acid-induced degradation products, followed by densitometric measurement of the intact spot at 285 nm. The separation was carried out on silica gel 60 F254 aluminum sheets using methanol-glacial acetic acid (22 + 3, v/v) mobile phase. The 1D method was based on the measurement of first-derivative amplitudes of tropisetron in H2O at the zero-crossing point of its acid-induced degradation product at 271.9 nm. Linearity, accuracy, and precision were found to be acceptable over concentration ranges of 40-240 microg/mL, 1-10 microg/spot, and 6-36 micro/mL for the HPLC, TLC, and 1D methods, respectively. The suggested methods were successfully applied for the determination of the drug in bulk powder, laboratory-prepared mixtures, and a commercial sample.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos , Indoles/análisis , Densitometría , Estabilidad de Medicamentos , Límite de Detección , Espectrofotometría Ultravioleta , Tropisetrón
2.
J Pharm Biomed Anal ; 36(5): 975-81, 2005 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-15620522

RESUMEN

Two reproducible stability indicating methods were developed for the determination of risperidone (RISP) in presence of its degradation products in pure form and in tablets. The first method was based on reversed phase high performance liquid chromatography (HPLC), on Lichrosorb RP C 18 column (250 mm i.d., 4 mm, 10 microm), using methanol:0.05 M potassium dihydrogen phosphate pH 7 (65:35 (v/v)) as the mobile phase at a flow rate of 1 ml min(-1) at ambient temperature. Quantification was achieved with UV detection at 280 nm over a concentration range of 25-500 microg ml(-1) with mean percentage recovery of 99.87 +/- 1.049. The method retained its accuracy in the presence of up to 90% of RISP degradation products. The second method was based on TLC separation of RISP from its degradation products followed by densitometric measurement of the intact drug spot at 280 nm. The separation was carried out on aluminum sheet of silica gel 60F254 using acetonitrile:methanol:propanol:triethanolamine (8.5:1.2:0.6:0.2 (v/v/v/v)), as the mobile phase, over a concentration range of 2-10 microg per spot and mean percentage recovery of 100.1 +/- 1.18. The two methods were simple, precise, sensitive and could be successfully applied for the determination of pure, laboratory prepared mixtures and tablets. The results obtained were compared with the manufacturer's method.


Asunto(s)
Risperidona/análisis , Risperidona/metabolismo , Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos , Densitometría/métodos , Polvos , Risperidona/química , Comprimidos
3.
Biomed Chromatogr ; 18(3): 143-9, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15103698

RESUMEN

Two sensitive and reproducible methods were developed and validated for the determination of ziprasidone (ZIP) in the presence of its degradation products in pure form and in pharmaceutical formulations. The fi rst method was based on reversed-phase high-performance liquid chromatography (HPLC), on a Lichrosorb RP C(18) column using water:acetonitrile:phosphoric acid (76:24:0.5 v/v/v) as the mobile phase at a fl ow rate of 1.5 mL min(-1) at ambient temperature. Quantification was achieved with UV detection at 229 nm over a concentration range of 10-500 micro g mL(-1) with mean percentage recovery of 99.71 +/- 0.55. The method retained its accuracy in presence of up to 90% of ZIP degradation products. The second method was based on TLC separation of ZIP from its degradation products followed by densitometric measurement of the intact drug spot at 247 nm. The separation was carried out on aluminium sheet of silica gel 60 F(254) using choloroform:methanol:glacial acetic acid (75:5:4.5 v/v/v) as the mobile phase, over a concentration range of 1-10 micro g per spot and mean percentage recovery of 99.26 +/- 0.39. Both methods were applied successfully to laboratory prepared mixtures and pharmaceutical capsules.


Asunto(s)
Antipsicóticos/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos , Densitometría/métodos , Preparaciones Farmacéuticas/química , Piperazinas/análisis , Polvos/química , Tiazoles/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA