1.
Ann Noninvasive Electrocardiol ; 18(2): 140-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23530484

RESUMEN

BACKGROUND: There are limited data regarding racial differences in response to cardiac resynchronization therapy with defibrillator (CRT-D). METHODS: We assessed the effectiveness of CRT-D, as compared to implantable cardioverter defibrillator (ICD) therapy alone, in reducing the risk of heart failure (HF) or death and changes in cardiac volumes among 1638 (90%) white patients and 143 (8%) black patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT). RESULTS: Enrolled black patients displayed a higher frequency of diabetes mellitus, treated hypertension, higher creatinine levels, and a lower distance walked in the baseline 6-minute walk test. Kaplan-Meier survival analysis showed that at 3 years of follow-up the cumulative probability of HF or death was higher among blacks (29%) as compared with whites (22%; P = 0.05). Both black and white patients experienced similar and pronounced reductions in cardiac volumes with CRT-D therapy (all P values for comparison between the two groups >0.10). Risk reduction conferred by CRT-D therapy as not significantly different between blacks and whites (hazard ratio = 0.78 and 0.60, respectively; P for the difference = 0.44). However, possibly due to sample size limitations the CRT-D versus ICD only adjusted risk for HF/death in blacks was not statistically significant. CONCLUSIONS: Black patients in MADIT-CRT experienced increased risk of HF or death as compared with whites, but displayed a similar magnitude echocardiographic response to CRT-D. These findings suggest that cardiac resynchronization therapy may be an effective therapeutic modality in black patients. However, further studies are needed to assess the clinical response to CRT-D in this high-risk population.


Asunto(s)
Población Negra/estadística & datos numéricos , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Cardiopatías/terapia , Insuficiencia Cardíaca/prevención & control , Población Blanca/estadística & datos numéricos , Anciano , Volumen Cardíaco , Muerte Súbita Cardíaca/prevención & control , Diabetes Mellitus , Ecocardiografía/métodos , Prueba de Esfuerzo/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Cardiopatías/complicaciones , Cardiopatías/mortalidad , Insuficiencia Cardíaca/mortalidad , Humanos , Hipertensión/complicaciones , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...