2.
Eur J Nutr ; 61(7): 3697-3706, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35689124

RESUMEN

PURPOSE: Serum magnesium is the most frequently used laboratory test for evaluating clinical magnesium status. Hypomagnesemia (low magnesium status), which is associated with many chronic diseases, is diagnosed using the serum magnesium reference range. Currently, no international consensus for a magnesemia normal range exists. Two independent groups designated 0.85 mmol/L (2.07 mg/dL; 1.7 mEq/L) as the low cut-off point defining hypomagnesemia. MaGNet discussions revealed differences in serum magnesium reference ranges used by members' hospitals and laboratories, presenting an urgent need for standardization. METHODS: We gathered and compared serum magnesium reference range values from our institutions, hospitals, and colleagues worldwide. RESULTS: Serum magnesium levels designating "hypomagnesemia" differ widely. Of 43 collected values, only 2 met 0.85 mmol/L as the low cut-off point to define hypomagnesemia. The remainder had lower cut-off values, which may underestimate hypomagnesemia diagnosis in hospital, clinical, and research assessments. Current serum magnesium reference ranges stem from "normal" populations, which unknowingly include persons with chronic latent magnesium deficit (CLMD). Serum magnesium levels of patients with CLMD fall within widely used "normal" ranges, but their magnesium status is too low for long-term health. The lower serum magnesium reference (0.85 mmol/L) proposed specifically prevents the inclusion of patients with CLMD. CONCLUSIONS: Widely varying serum magnesium reference ranges render our use of this important medical tool imprecise, minimizing impacts of low magnesium status or hypomagnesemia as a marker of disease risk. To appropriately diagnose, increase awareness of, and manage magnesium status, it is critical to standardize lower reference values for serum magnesium at 0.85 mmol/L (2.07 mg/dL; 1.7 mEq/L).


Asunto(s)
Magnesio , Humanos , Estándares de Referencia , Valores de Referencia
4.
J Appl Lab Med ; 4(3): 323-330, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31659070

RESUMEN

BACKGROUND: κ and λ free light chains (FLCs) are monitored to aid in the diagnosis of plasma cell disorders. Our goal was to validate the Diazyme Human κ and λ assays on Beckman Coulter UniCel DxC 800 Synchron and compare to Freelite κ and λ assays on Roche Cobas Integra. METHODS: Linearity verification, within- and between-run precision, method comparison, and reference range (RR) verification were conducted using CLSI guidelines. Statistical analysis was performed using EP Evaluator®. Mean, SD, CV, and bias were determined. RESULTS: Diazyme κ FLC assay was linear within 0.00-191.00 mg/L. Diazyme λ FLC assay was linear within 0.00-205.30 mg/L. Diazyme κ FLC QC1 had a mean of 16.70 mg/L, CV of 7.0%. QC2 had a mean of 33.37 mg/L, CV of 2.6%. Diazyme λ FLC QC1 had a mean of 21.73 mg/L, CV of 2.3%. QC2 had a mean of 42.05 mg/L, CV of 1.5%. Bias of DxC-Diazyme FLCs compared to Integra-Freelite FLCs was -2.55 mg/L (κ FLC), and 4.54 mg/L (λ FLC). Qualitative comparison of κ FLC assays indicated 100% agreement for both normal and abnormal values. For λ FLC assay, agreement was 95% for normal values and 75% for abnormal values. For κ/λ ratio there was 50% agreement for normal values, and 100% for abnormal values. For RR verification, 1 sample was outside the Diazyme κ RR. For λ, all samples were within the manufacturer's RR. CONCLUSIONS: Diazyme assays for FLCs have excellent precision and accuracy and are comparable to Freelite assays.


Asunto(s)
Aprobación de Pruebas de Diagnóstico , Cadenas kappa de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Pruebas Inmunológicas/métodos , Pruebas Inmunológicas/normas , Humanos , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Estados Unidos/epidemiología , United States Food and Drug Administration
5.
Adv Nutr ; 7(6): 977-993, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-28140318

RESUMEN

The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75-0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health.


Asunto(s)
Deficiencia de Magnesio/sangre , Magnesio/sangre , Evaluación Nutricional , Política Nutricional , Necesidades Nutricionales , Animales , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/etiología , Humanos , Inflamación/sangre , Inflamación/etiología , Magnesio/orina , Deficiencia de Magnesio/complicaciones , Enfermedades Metabólicas/sangre , Enfermedades Metabólicas/etiología , Enfermedades Musculoesqueléticas/sangre , Enfermedades Musculoesqueléticas/etiología , Enfermedades del Sistema Nervioso/sangre , Enfermedades del Sistema Nervioso/etiología , Valores de Referencia
6.
N Engl J Med ; 370(9): 881, 2014 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-24571768
8.
Magnes Res ; 25(2): 54-63, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22728448

RESUMEN

BACKGROUND: Gestational diabetes mellitus (GDM) and low magnesium (Mg) intake and status are associated with an increased risk of type 2 diabetes. However, Mg homeostasis may be modified by GDM. We sought to determine if a history of GDM prospectively modifies associations between Mg and glycemic variables in mothers and their offspring. METHODS: Plasma and dietary Mg, anthropometric, lifestyle and glycemic variables were assessed in mothers affected by GDM during 1989-1990, a comparative group of normoglycemic women, pregnant during the same time period, and the 15-year-old, nondiabetic daughters of affected and unaffected pregnancies (n = 332). Multivariate regression analyses evaluated the cross-sectional association between plasma and dietary Mg with glycemic variables in mothers and daughters. RESULTS: Plasma Mg was lower in mothers with a history of GDM in comparison to control mothers after adjustment for current type 2 diabetes, race and body mass index (0.90 ± 0.01 versus 0.96 ± 0.01 mmol/L; p = 0.002). Plasma Mg was significantly associated with insulin sensitivity and was inversely associated with fasting insulin in GDM mothers only (p<0.05). Plasma and dietary Mg were significantly inversely associated with glycated hemoglobin and fasting glucose, respectively, in nondiabetic teenage daughters. For fasting glucose, plasma Mg was inversely associated in GDM-born daughters only. CONCLUSIONS: Associations between plasma Mg and some glycemic variables may be stronger in mothers and offspring with a history of GDM.


Asunto(s)
Glucemia/metabolismo , Intolerancia a la Glucosa/sangre , Magnesio/sangre , Madres , Núcleo Familiar , Periodo Posparto/sangre , Adolescente , Adulto , Niño , Demografía , Dieta , Femenino , Humanos , Estilo de Vida , Modelos Lineales , Persona de Mediana Edad , Embarazo
10.
Cardiovasc Diabetol ; 11: 23, 2012 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-22405520

RESUMEN

BACKGROUND: Premature ventricular complexes (PVC) predict cardiovascular mortality among several adult populations. Increased arrhythmia prevalence has been reported during controlled magnesium (Mg) depletion studies in adults. We thus hypothesized that serum magnesium (sMg) concentrations are inversely associated with the prevalence of PVC in adults at high cardiovascular risk. METHODS: Anthropometric, demographic and lifestyle characteristics were assessed in 750 Cree adults, aged > 18 yrs, who participated in an age-stratified, cross-sectional health survey in Quebec, Canada. Holter electrocardiograms recorded heart rate variability and cardiac arrhythmias for two consecutive hours. Multivariate logistic regression was used to evaluate the associations between sMg and PVC. RESULTS: PVC prevalence in adults with hypomagnesemia (sMg ≤ 0.70 mmol/L) was more than twice that of adults without hypomagnesemia (50% vs. 21%, p = 0.015); results were similar when adults with cardiovascular disease history were excluded. All hypomagnesemic adults with PVC had type 2 diabetes (T2DM). Prevalence of PVC declined across the sMg concentration gradient in adults with T2DM only (p < 0.001 for linear trend). In multivariate logistic regressions adjusted for age, sex, community, body mass index, smoking, physical activity, alcohol consumption, kidney disease, antihypertensive and cholesterol lowering drug use, and blood docosahexaenoic acid concentrations, the odds ratio of PVC among T2DM subjects with sMg > 0.70 mmol/L was 0.24 (95% CI: 0.06-0.98) p = 0.046 compared to those with sMg ≤ 0.70 mmol/L. CONCLUSIONS: sMg concentrations were inversely associated with the prevalence of PVC in patients with T2DM in a dose response manner, indicating that suboptimal sMg may be a contributor to arrhythmias among patients with T2DM.


Asunto(s)
Diabetes Mellitus Tipo 2/epidemiología , Magnesio/sangre , Obesidad/epidemiología , Complejos Prematuros Ventriculares/epidemiología , Adulto , Comorbilidad , Estudios Transversales , Diabetes Mellitus Tipo 2/sangre , Femenino , Encuestas Epidemiológicas , Frecuencia Cardíaca , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Obesidad/sangre , Prevalencia , Quebec
12.
Magnes Res ; 23(4): S194-8, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20736141

RESUMEN

Magnesium is an essential element needed for health. Even though only 1% of the total body magnesium is present in blood, the serum magnesium concentration (SMC) is the predominant test used by medicine to assess magnesium status in patients. The traditional method to establish a reference interval for the SMC is flawed by the large number of "normal" individuals who have a subtle chronic negative magnesium balance due to a significant decrease in magnesium intake over the past century. Evidence-based medicine should be used to establish the appropriate lower limit of the reference interval for health and I recommend 0.85 mmol/L based on current literature. The decrease in magnesium in the diet has led to chronic latent magnesium deficiency in a large number of people since their SMC is still within the reference interval due to primarily the bone magnesium supplementing the SMC. These individuals need adjustment of their diet or magnesium supplementation to achieve a normal magnesium status for health.


Asunto(s)
Deficiencia de Magnesio/sangre , Deficiencia de Magnesio/diagnóstico , Magnesio/sangre , Suplementos Dietéticos , Medicina Basada en la Evidencia/métodos , Humanos , Deficiencia de Magnesio/dietoterapia
13.
Ann Clin Lab Sci ; 38(2): 132-7, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18469358

RESUMEN

Ischemia modified albumin (IMA) is a relatively new marker for evaluating patients with cardiac ischemia. Data are emerging on its potential role in non-cardiac ischemic events. In this pilot study we evaluated the utility of IMA in diagnosing acute coronary syndromes (ACS), assessed its role in the diagnosis of non-cardiac ischemia, and correlated its efficacy with troponin T (TnT). Serum levels of IMA were measured in 89 sequential patients who presented to the emergency room with chest pain for which serum TnT was ordered. The patients were classified into 4 groups based on their IMA and TnT results and discharge diagnoses. The data were analyzed with Fischer's exact test. Multivariate logistic regression analysis relating acute coronary syndrome (ACS) to the combination of TnT and IMA was also performed. The results showed that IMA was a useful marker for the diagnosis of ACS. There was a significant relationship between TnT and IMA (p = 0.032), suggesting that both these biomarkers added significant information about the presence of ACS (p = 0.028) and may be useful for triage of patients who present to the emergency room with chest pain. Serum IMA was also increased in a small proportion of patients with symptoms of stroke, suggesting that it should be considered a marker of acute ischemic events and not specific for cardiac ischemia.


Asunto(s)
Isquemia Miocárdica/sangre , Isquemia Miocárdica/diagnóstico , Albúmina Sérica/química , Albúmina Sérica/metabolismo , Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/diagnóstico , Enfermedad Aguda , Adulto , Anciano , Angina de Pecho/sangre , Angina de Pecho/diagnóstico , Biomarcadores/sangre , Dolor en el Pecho/sangre , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Retrospectivos , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/diagnóstico , Troponina T/sangre
15.
Biol Psychiatry ; 59(4): 327-33, 2006 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-16197921

RESUMEN

BACKGROUND: Conflicting data exist regarding the presence of magnesium (Mg) deficiency and the therapeutic efficacy of Mg in premenstrual syndrome or premenstrual dysphoric disorder (PMDD). METHODS: The % Mg retention was determined using 24-hour urinary Mg excretion and the total dose of Mg given intravenously. In women with (n = 17) and without (n = 14) prospectively diagnosed PMDD, several blood measures of Mg and mood were obtained before, immediately after, and the day following an intravenous Mg (.1 mmol/kg) loading dose. A positive mood response was seen under open conditions; as open Mg infusion improved mood, subsequent PMDD patients (n = 10) were randomized in a double-blind, placebo-controlled, crossover fashion. RESULTS: Patients (31.5%) and control subjects (27.5%) retained comparable mean percentages of Mg. Neither group differed in measures of mean Mg before, immediately after, or the day following Mg infusion. Although there was a time effect for all mood measures in the patient group (p < .01 for all), there was neither a treatment nor time-by-treatment effect. CONCLUSIONS: Contrary to prior reports, we found no evidence of Mg deficiency in women with PMDD compared with control subjects. Furthermore, Mg was not superior to placebo in the mitigation of mood symptoms in women with PMDD.


Asunto(s)
Afecto/efectos de los fármacos , Magnesio/metabolismo , Magnesio/uso terapéutico , Síndrome Premenstrual/tratamiento farmacológico , Síndrome Premenstrual/metabolismo , Adulto , Estudios Cruzados , Método Doble Ciego , Eritrocitos/metabolismo , Femenino , Humanos , Infusiones Intravenosas , Magnesio/administración & dosificación , Deficiencia de Magnesio/sangre , Deficiencia de Magnesio/psicología , Síndrome Premenstrual/psicología
16.
Clin Chim Acta ; 366(1-2): 341-3, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16337169

RESUMEN

BACKGROUND: Treatment of serum with ethanol at 100 ml/l eliminating fibrinogen from electrophoretic pattern produces an additional band at alpha2/beta junction. This study is to determine the source and the nature of this artifact. METHODS: The supernatant after ethanol precipitation was used for electrophoresis. Protein concentrations of each fraction in ethanol- and saline-treated samples were compared, and immunofixation electrophoresis (IFE) to identify transferrin, C3, and LDL was performed. C3 IFE was also conducted for fresh sera and sera stored for 2 weeks. RESULTS: The artificial band at alpha2/beta junction was identified in ethanol-treated sera but not in saline-treated sera. Protein concentration in the beta fraction was reduced after ethanol treatment as compared to saline-treated samples (n=10, p<0.01). The spurious band at alpha2/beta junction was recognized in C3 IFE. C3 IFE also showed a band at alpha2/beta junction in samples stored for 2 weeks. CONCLUSIONS: Ethanol treatment of serum creates an artificial band with C3 immunoreactivity at alpha2/beta junction. This could be due to the accelerated hydrolysis of C3 by ethanol treatment. Laboratories using ethanol to evaluate a possible fibrinogen band should be aware of this phenomenon, and the serum protein electrophoretic pattern after ethanol treatment should only be used to rule out fibrinogen.


Asunto(s)
Artefactos , Proteínas Sanguíneas/análisis , Etanol/farmacología , Electroforesis de las Proteínas Sanguíneas/métodos , Proteínas Sanguíneas/efectos de los fármacos , Reproducibilidad de los Resultados
17.
Am J Clin Pathol ; 124(1): 108-12, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15923168

RESUMEN

Positive pregnancy test results occurred in a nongravid, premenopausal woman while she was receiving chemotherapy for multiple myeloma. We tested 2 hypotheses to account for this finding: (1) Heterophil antibodies caused positive interference in the immunoassays. (2) Genuine human chorionic gonadotropin (hCG) originated from a nonsyncytiotrophoblastic source. Paraprotein was eliminated as a source of positive interference because 3 different instruments with unique capture and signal antibodies gave similar results (83, 90, and 97 mIU/mL [83, 90, and 97 IU/L]). Human antimouse antibodies (HAMAs) were unlikely to cause positive interference because immunoreactivity was maintained after serum was treated to neutralize heterophil antibodies. Immunoassays performed after gel filtration of serum indicated that immunoreactivity was due to genuine hCG. The high-molecular-weight fraction (heterophil antibody) had 6 mIU/mL (6 IU/L) of hCG. The low-molecular-weight fraction (hCG) had 86 mIU/mL (86 IU/L) of hCG. Immunohistochemical stains revealed that myeloma cells expressed immunoreactive hCG. Hence, multiple myeloma caused positive pregnancy test results in a nongravid woman.


Asunto(s)
Gonadotropina Coriónica Humana de Subunidad beta/biosíntesis , Mieloma Múltiple/metabolismo , Pruebas de Embarazo , Premenopausia , Adulto , Médula Ósea/metabolismo , Médula Ósea/patología , Gonadotropina Coriónica Humana de Subunidad beta/sangre , Reacciones Falso Positivas , Femenino , Humanos , Inmunohistoquímica , Células Plasmáticas/metabolismo , Células Plasmáticas/patología , Embarazo
19.
Arch Pathol Lab Med ; 129(3): 305-9, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15737022

RESUMEN

CONTEXT: The College of American Pathologists (CAP) provides proficiency testing (PT) surveys to laboratories around the world. OBJECTIVES: To compare diagnostic assay methods for serum/plasma cortisol and immunoglobulin (Ig) E in terms of their bias and precision, to determine how well CAP PT specimens simulate human serum, and to reassess proficiency test grading criteria in light of these findings. DESIGN: A participant-blinded, prospective trial. One vial of pooled fresh frozen serum (FFS) and 4 different admixtures of PT material (PTM) were sent to laboratories participating in PT surveys. PARTICIPANTS: Laboratories providing cortisol (>1000) or IgE (>230) results among the subscribers to the CAP surveys, Ligand (General) 2003, set K/KN-A and Chemistry 2003, set C-C. MAIN OUTCOME MEASURES: The main outcome measures were (1) bias among laboratories using the same method (peer groups), defined relative to the median of method means (MedMM); (2) imprecision as measured by the SD and coefficient of variation (CV) about each method mean; and (3) total error across laboratories for the FFS cortisol results, defined as |Bias Relative to Reference Method| + 2 SD. RESULTS: Cortisol method biases, relative to MedMM, ranged from -22% to 9% for the FFS challenge and from -24% to 36% for comparable PTM challenges. The method biases, relative to the reference method, ranged from -3% to 19% for the FFS challenge. The cortisol method CVs ranged from 4.2% to 13.6% for the FFS challenge and from 4.7% to 12.7% for comparable PTM challenges. Total error across laboratories ranged from 1.4 to 6.9 microg/dL (39 to 190 nmol/L) for the FFS challenge. Immunoglobulin E method biases, relative to MedMM, ranged from -8% to 9% for the FFS challenge and from -7% to 5% for comparable PTM challenges. The IgE method CVs ranged from 3.6% to 6.7% for the FFS challenge and from 3.4% to 9.8% for comparable PTM challenges. CONCLUSIONS: The bias for cortisol results was less with FFS than with PTM, but imprecision was comparable. The FFS MedMM was 8.5% higher than the reference value. Fresh frozen serum and PTM bias and imprecision for IgE methods were each less than 10%. Because some of the methods demonstrated greater bias when analyzing PTM than FFS, peer group grading of both these analytes is appropriate.


Asunto(s)
Hidrocortisona/sangre , Inmunoglobulina E/sangre , Patología Clínica/normas , Plasma/química , Técnicas de Laboratorio Clínico/normas , Recolección de Datos/métodos , Recolección de Datos/estadística & datos numéricos , Humanos , Variaciones Dependientes del Observador , Estudios Prospectivos , Método Simple Ciego , Estados Unidos
20.
Arch Pathol Lab Med ; 129(3): 310-7, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15737023

RESUMEN

CONTEXT: In proficiency testing surveys, there are differences in the values reported by users of various analytic methods. Two contributors to this variation are calibrator bias and matrix effects of proficiency testing materials. OBJECTIVES: (1) To quantify the biases of the analytic methods used to measure thyroid-stimulating hormone, thyroxine, triiodothyronine, free thyroxine, and free triiodothyronine levels; (2) to determine if these biases are within allowable limits; and (3) to ascertain if proficiency testing materials correctly identify these biases. DESIGN: A fresh frozen serum specimen was mailed as part of the 2003 College of American Pathologists Ligand and Chemistry surveys. The means and SDs for each analytic method were determined for this sample as well as for a proficiency testing sample from both surveys. In the fresh frozen serum sample, target values for thyroxine and triiodothyronine were determined by isotope dilution/liquid chromatography/tandem mass spectrometry. All other target values in the study were the median of the means obtained for the various analytic methods. MAIN OUTCOME MEASURES: Calibration biases were calculated by comparing the mean of each analytic method with the appropriate target values. These biases were evaluated against limits based on intra- and interindividual biological variation. Matrix effects of proficiency testing materials were assessed by comparing the rank of highest to lowest analytic method means (Spearman rank test) for each analyte. PARTICIPANTS: Approximately 3900 clinical laboratories were enrolled in the College of American Pathologists Chemistry and Ligand surveys. RESULTS: The number of methods in the Ligand Survey that failed to meet the goals for bias was 7 of 17 for thyroid-stimulating hormone and 11 of 13 for free thyroxine. The failure rates were 12 of 16 methods for thyroxine, 8 of 11 for triiodothyronine, and 9 of 11 for free triiodothyronine. The means of the analytic method for the proficiency testing material correlated significantly (P < .05) only with the fresh frozen serum means for thyroxine and thyroid-stimulating hormone in the Chemistry Survey and free triiodothyronine in the Ligand Survey. CONCLUSIONS: A majority of the methods used in thyroid function testing have biases that limit their clinical utility. Traditional proficiency testing materials do not adequately reflect these biases.


Asunto(s)
Patología Clínica/normas , Plasma/química , Pruebas de Función de la Tiroides/estadística & datos numéricos , Pruebas de Función de la Tiroides/normas , Calibración/normas , Técnicas de Laboratorio Clínico/normas , Recolección de Datos/normas , Recolección de Datos/estadística & datos numéricos , Humanos , Variaciones Dependientes del Observador , Tirotropina/sangre , Tiroxina/sangre , Triyodotironina/sangre , Estados Unidos